Radio frequency identification systems technology in the surgical setting.

Radio frequency identification (RFID) is a technology that will have a profound impact on medicine and the operating room of the future. The purpose of this article is to provide an introduction to this exciting technology and a description of the problems in the perioperative environment that RFID might address to improve safety and increase productivity. Although RFID is still a nascent technology, applications are likely to become much more visible in patient care and treatment areas and will raise questions for practitioners. We also address both the current limitations and what appear to be reasonable near-future possibilities.

Diffusion of Innovation↗

Cellular radio telecommunication for health care: benefits and risks.

Cellular radio telecommunication has increased exponentially with many applications to health care reported. The authors attempt to summarize published applications with demonstrated effect on health care, review briefly the rapid evolution of hardware and software standards, explain current limitations and future potential of data quality and security, and discuss issues of safety.

Algorithms↗

A radio-based approach to promoting gun safety: process and outcome evaluation implications and insights.

Three radio public service announcements (PSA) were created to increase knowledge of 10 gun-safety practices in a mid-Michigan county. Concurrently, a direct-mail coupon highlighting the same gun-safety practices was disseminated to over 70,000 households in the same county. Results of a telephone survey indicate that, compared to unexposed individuals, those who were exposed to the PSA were able to name significantly more gun-safety practices. Specifically, significant differences between those exposed to the PSA versus those not exposed were found for 5 gun-safety practices, as well as for a 4-item index measuring gun locking and storage behaviors, and a 9-item index that included all gun-safety practices.

Firearms↗

Talk about receiving, giving, and taking in radio interviews: 'doing modesty' and 'making a virtue out of necessity'.

Acts of giving, receiving, and taking constitute much of our social lives, and talk about these acts is ubiquitous. However, such talk has not been studied in its own right. From radio interviews with persons who have accomplished or experienced something deemed remarkable, I identified two social actions that were accomplished by talk about receiving, giving, and taking: 'doing modesty' and 'making a virtue out of necessity'. Doing modesty was present in interviews with celebrities and was deftly managed through the joint use of contrasts by the participants. Making a virtue out of necessity was present in interviews in which the interviewee's experience of adversity was a prominent focus of talk, and was accomplished through the use of irony. I argue that both actions can serve the dual purposes of putting the interviewee in a good light and holding the attention of the listening audience. This research adds to existing work on social ties by providing another route for understanding how we make use of the exchange of social resources.

Humans↗

Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound.

Both radio-frequency (rf) and envelope-detected signal analyses have lead to successful tissue discrimination in medical ultrasound. The extrapolation from tissue discrimination to a description of the tissue structure requires an analysis of the statistics of complex signals. To that end, first- and second-order statistics of complex random signals are reviewed, and an example is taken from rf signal analysis of the backscattered echoes from diffuse scatterers. In this case the scattering form factor of small scatterers can be easily separated from long-range structure and corrected for the transducer characteristics, thereby yielding an instrument-independent tissue signature. The statistics of the more economical envelope- and square-law-detected signals are derived next and found to be almost identical when normalized autocorrelation functions are used. Of the two nonlinear methods of detection, the square-law or intensity scheme gives rise to statistics that are more transparent to physical insight. Moreover, an analysis of the intensity-correlation structure indicates that the contributions to the total echo signal from the diffuse scatter and from the steady and variable components of coherent scatter can still be separated and used for tissue characterization. However, this analysis is not system independent. Finally, the statistical methods of this paper may be applied directly to envelope signals in nuclear-magnetic-resonance imaging because of the approximate equivalence of second-order statistics for magnitude and intensity.

Humans↗

[In-house radio-assisted emergency call system in continuous monitoring of microcirculation using laser doppler flowmetry].

Instrumental monitoring is being increasingly employed in the postoperative phase after microsurgery. For this purpose, laser Doppler flowmetry has proven to be very useful. Monitoring of the perfusion of tissue with blood is mainly by clinical examination, which, however, requires the physical presence of the observer, and this is generally not possible on a continuous basis. By connecting up a laser Doppler unit with a computer and telephone modem and making use of the in-house radio system, it proved possible to produce an automatic emergency call system that responds to a worsening of perfusion and alerts the responsible doctor. For this purpose, the software program "call-doc" was developed, which provides the necessary monitoring and control functions. A general perfusion-independent emergency call can also be triggered at the touch of a button.

Emergency Medical Service Communication Systems↗

Health risks of electromagnetic fields. Part II: Evaluation and assessment of radio frequency radiation.

The increasing use of different radio frequency (RF)-emitting devices in residential and occupational settings has raised concerns about possible health effects of RF energy emitted by such devices. The debate about the potential risks associated with RF fields will persist with the prevalent network-connected wireless products and services targeting the marketplace for all kinds of consumer use. The aim of this article is to provide biomedical researchers with a review and critical evaluation of the current literature on acute and long-term health risks associated with RF radiation (RFR). Issues examined include safety standards for RFR; dosimetry and measurement surveys; and toxicological, epidemiological, and clinical studies of health outcomes that may be associated with RFR. Overall, the existing evidence for a causal relationship between RFR and adverse health effects is limited. Additional research is needed to clarify possible associations between RFR and biological effects noted in some studies. Particular attention should be directed toward long-term, low-level exposure to RFR.

Animals↗

Radio frequency heating: a new potential means of post-harvest pest control in nuts and dry products.

The multi-billion dollar US tree nut industries rely heavily on methyl bromide fumigation for postharvest insect control and are facing a major challenge with the mandated cessation by 2005 of its use for most applications. There is an urgent need to develop effective and economically viable alternative treatments to replace current phytosanitary and quarantine practices in order to maintain the competitiveness of US agriculture in domestic and international markets. With the reliable heating block system, the thermal death kinetics for fifth-instar codling moth, Indianmeal moth, and navel orangeworm were determined at a heating rate of 18 degrees C/min. A practical process protocol was developed to control the most heat resistant insect pest, fifth-instar navel orangeworm, in in-shell walnuts using a 27 MHz pilot scale radio frequency (RF) system. RF heating to 55 degrees C and holding in hot air for at least 5 min resulted in 100% mortality of the fifth-instar navel orangeworm. Rancidity, sensory qualities and shell characteristics were not affected by the treatments. If this method can be economically integrated into the handling process, it should have excellent potential as a disinfestation method for in-shell walnuts.

Animals↗

Radio frequency clipping in hearing aids.

For those patients with reduced dynamic range of hearing, accomodation of normal dynamic range of speech has always presented a problem. This paper describes a method of overcoming the problem, a method which has the added benefit of offering improved speech discrimination as well as limiting the output from a hearing aid system. The principle employed is the presentation of taped speech material processed through clipping of a radio frequency single side side band suppressed carrier signal, which is filtered to remove the Fourier components and demodulated to obtain the modified speech material. Groups of normally hearing and hearing impaired subjects undergo speech audiometry testing to assess what improvement can be effected by this system. The majority of subjects tested both normal and hearing impaired achieve improved speech discrimination when using the system described. Further once the output was set no increase in the input signal could produce a level in excess of that set by the output control.

Adult↗

Radio pills: their use in monitoring back stress.

A system for the quantitative assessment of spinal stress during manual materials handling has been developed. This has been achieved using radio pressure pills and is applicable to both laboratroy and field use for establishing safe general handling procedures and defining safe maximum loads.

Abdomen↗

Controlling radio frequency interference from neurological prostheses.

The simplest kind of radio frequency (RF) coupled neurological prosthesis, in which a burst of RF, generated by the external equipment, provides the stimulus energy via a passive implanted receiver, is the most troublesome in respect of RF interference (RFI). Because the low ratio of pulse duration to interpulse interval is usually the case, the peak power transmitted is necessarily high, of the order of watts. This paper outlines a series of measurements by which the mode of RFI generation by a typical external equipment was precisely identified, enabling rational and appropriate countermeasures to be taken.

Electric Stimulation↗

Radio frequency identification applications in hospital environments.

Radio frequency identification (RFID) technology has recently begun to receive increased interest from practitioners and academicians. This interest is driven by mandates from major retailers such as Wal-Mart, Target and Metro Group, and the United States Department of Defense, in order to increase the efficiency and visibility of material and information flows in the supply chain. However, supply chain managers do not have a monopoly on the deployment of RFID. In this article, the authors discuss the potential benefits, the areas of applications, the implementation challenges, and the corresponding strategies of RFID in hospital environments.

Diffusion of Innovation↗

Inactivation of Saccharomyces cerevisiae with radio frequency electric fields.

The application of radio frequency (RF) electric fields as a nonthermal alternative to thermal inactivation of microorganisms in liquids was investigated. A novel RF system producing frequencies in the range of 20 to 60 kHz was developed. Electric field strengths of 20 and 30 kV/cm were applied to suspensions of Saccharomyces cerevisiae in water over a temperature range of 35 to 55 degrees C. The flow rate was 1.2 liters/min. The S. cerevisiae population was reduced by 2.1 +/- 0.1 log units following exposure to a 30-kV/cm field at 40 degrees C. The results of the present study provide the first evidence that strong RF electric fields inactivate microorganisms at moderately low temperatures. Increasing the field strength, the number of treatments, and the temperature enhanced inactivation. Frequency had no effect on inactivation over the range of frequencies studied.

Beverages↗

Treatment of verrucae via radio wave surgery.

Verrucae are common skin lesions seen mainly in younger patients. They often are seen on the plantar surface of the foot. Many different types of treatments have been used over the years, with varying levels of success. The authors present a thorough review of previous treatments and present a new and effective method of surgical excision using radio wave technique. The success of this treatment is high, and the postsurgical pain and complication level is minimal.

Adolescent↗

Radio station acceptance of AIDS-related advertising messages.

Survey responses were received from the managers of 630 radio stations, who reported which type of AIDS-related commercials or public service announcements they are willing to accept for broadcast. The authors examine whether the public interest can outweigh fear of offending audience segments and discuss ways health education planners can increase acceptance of AIDS-related commercials. For planning a public health campaign, both the number and types of stations that will accept various public health messages are important if the messages are to reach high risk demographic groups.

Acquired Immunodeficiency Syndrome↗

Cost cutting using radio frequency inventory control.

Bar coding should be a staple in every hospital by now--but it's not. The author tells how bar coding and the use of radio frequency transmission of inventory data direct to their mainframe computer has saved them time and money.

Computer Communication Networks↗

Multiple-address radio systems, allocation of forty-eight 25 kHz channels in the 900 MHz range; and establishment of a new standard for frequency tolerance in the 952-960 MHz band: Federal Communications Commission. Third notice of proposed rulemaking.

In response to a petition, the Commission proposes the reallocation of forty-eight 25 kHz channels in the 928-929 and 952-960 MHz band segments to the Private Operational-Fixed Microwave Service and the Domestic Public Land Mobile Radio Service for distribution automation and wide-area control and repeater operations, respectively. The spectrum from 928 to 929 MHz is presently reserved for Land Mobile. The 952-950 MHz band is currently allocated to the Private Operational-Fixed Microwave Service and the International Control Services.

Emergency Medical Service Communication Systems↗