Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Retention”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Retention of quartz-fibre endodontic posts with a self-adhesive dual cure resin cement.

This study examines retention of a quartz-fibre endodontic post cemented in extracted human teeth using two cement types. Fifty-four extracted buman central incisor teeth were prepared for a tapered quartz-fibre post. Posts were cemented in 28 teeth using conventional resin cement (RelyX ARC), and 26 teeth using self-adhesive resin cement (RelyX Unicem). Posts were cyclically-loaded. Bond strengths were tested and dependability assessment was carried out. Although there was no significant difference in Weibull modulus between groups (p < 0.05), greater dependability was displayed by RelyX Unicem group. Easy application and greater dependability of self-adhesive cement may improve bonding of fibre-based posts in root canals.

Bisphenol A-Glycidyl Methacrylate↗

Effect of cement types on the tensile strength of metallic crowns submitted to thermocycling.

The relationship between metallic cast crowns and tensile strength according to cement types submitted to thermocycling was studied. Seventy-two metallic crowns were cast with Verabond II Ni-Cr alloy and cemented in standardized preparations with 10 masculine tapering. Three types of finishing line (45-degree chamfered, 20-degree bevel shoulder and right shoulder) were made with diamond burs on bovine teeth. Twenty-four metallic crowns in each group were randomly subdivided into three subgroups of 8 samples each according to the cement used: SS White zinc phosphate cement, Vitremer resin-modified glass ionomer cement, and Rely X resin cement and were submitted to thermocycling. Retention was evaluated according to tensile load required to displace the metallic cast crowns from tooth preparations with an Instron testing machine. ANOVA and Tukey's test showed a statistically significant difference among luting materials, with greater results for Rely X resin cement (24.9 kgf) followed by SS White zinc phosphate cement (13.3 kgf) and Vitremer resin-modified glass ionomer cement (10.1 kgf). The finishing line types did not influence the tensile resistance of the crowns fixed with the three cements. Increased tensile resistance of metallic crowns fixed on bovine teeth was obtained with resin cement, independent of the finishing line types.

Animals↗

Comparison of conventional and resin-modified glass-ionomer luting cements in the retention of post-crowns by fatigue loading.

Fatigue testing may be used for in vitro evaluation of luting cements, allowing comparison of materials under controlled conditions. It is recognized that glass-ionomer cements are materials which are susceptible to microcracking, even during curing prior to load application, and their failure can be related to crack propagation. The aim of this study was to compare the retention of post-crowns cemented with conventional and resin-modified glass-ionomer cements, the latter having significantly greater fracture toughness, under cyclic loads which are representative of physiological service. A custom-designed fatigue machine was used for three tests each comprising 18 specimens in a modified randomized complete block programme. Correlation of load amplitude to endurance was low, as expected from static test experience, but cement comparison was made through Kaplan-Meier survival and cumulative hazard functions. Differences in the performance of the cements were indicated, but were not statistically significant in this study, although analysis by Cox's proportional hazards model indicated that significance may be gained by a larger study.

Acrylic Resins↗

Rigidity and retention of carbon fibre versus stainless steel root canal posts.

Two of the main requirements of a root canal post are that it is rigid so as to resist flexing under functional load, and that it is well retained in the root. This study compared these properties in two different 1-mm diameter root canal posts--smooth carbon fibre posts (Endopost) and serrated stainless steel posts (Parapost). Ten posts of each type were tested for rigidity in a three-point bend test. Ten posts of each type were cemented with resin cement into the roots of endodontically treated, extracted teeth. The tensile force required to remove the posts was recorded. The Paraposts proved to be significantly more rigid under load (P < 0.001) and significantly more strongly retained in the tooth roots (P < 0.005). The Parapost appears to be a mechanically superior post for the restoration of root-filled teeth with narrow diameter root canals.

Carbon↗

Immediate occlusal loading of freestanding implants using cortical satellite implants: preliminary report of a prospective study.

Freestanding implants with mandibular overdentures are used frequently after 3 months' healing time. Immediate full loading may be applied to this approach if sufficient primary stability is provided. The present study evaluates the success rate of two single-standing interforaminal implants stabilized with cortical satellite implants and loaded immediately with overdentures. Twenty patients (five male and 15 female; age, 45-87 years) received two single-standing titanium screw implants (Semados, Bego, Bremen, Germany). All implants were stabilized during healing time with cortical satellite implants (2.0-mm bone screws; Medartis, Basel, Switzerland) via individual connectors attached to the implant abutment subgingivally. Mandibular overdentures were incorporated immediately after surgery using ball attachments as retentive elements. The patients were under no restrictions concerning diet and loading. The satellite implants were removed after 3 months. All implants were osseointegrated after 10 months' mean observation time. The mean Periotest value was -4.9, and the mean marginal bone loss was 0.7 mm. No dropouts were observed, and 19 of 20 patients would recommend the treatment to a close friend. Preliminary follow-up data indicate that cortical stabilization of two anterior mandibular implants with satellite implants leads to osseointegration of the implants under immediate load conditions with an overdenture. This concept contributes to reduction of prosthetic treatment costs and permits immediate enhancement of masticatory function.

Aged↗

Clinical evaluation of and parental satisfaction with resin-faced stainless steel crowns.

PURPOSE: This study evaluated the clinical success and parental acceptance of anterior primary dentition caries treatment with prefabricated resin-faced stainless steel crowns. METHODS: A retrospective analysis of maxillary anterior primary dentition caries treatment using Whiter Biter II Crowns was performed. Each crown was evaluated for retention, fracture, interface failure, color match, marginal integrity, and surface texture. Parental satisfaction regarding the esthetics of the crowns was evaluated by survey. RESULTS: Thirty-eight crowns were evaluated in 12 children. The average crown age at time of examination was 20.7 months. Three teeth were lost to trauma with all other crowns remaining intact. Twelve crowns (32%) showed loss of at least some facial resin. Nine crowns (24%) had complete loss of the resin facing. Overall parental satisfaction with the treatment was excellent, however, satisfaction with crown esthetics received the lowest rating. CONCLUSIONS: While parental satisfaction with treatment of anterior primary dentition caries with prefabricated resin-faced stainless steel crowns is excellent, the high failure rate of the resin facings is problematic.

Child↗

The use of resin cements in restorative dentistry to overcome retention problems.

The use of resin cements in combination with dentin bonding agents can result in superior attachment of prostheses to tooth structure. This paper describes four clinical cases in which dentin-bonded resin cements were used to overcome retention problems. In the first case, a detached fixed partial denture, which was in good condition when separated, was recemented to abutment teeth prepared with less-than-ideal angle of convergence. In the second case, a detached all-porcelain crown was recemented with a dentin-bonded resin cement after appropriate surface treatment. In the third case, a porcelain-fused-to-metal crown made for a molar tooth was cemented to a short clinical crown, avoiding crown-lengthening surgery. In the fourth case, a 3-unit fixed partial denture was recemented to abutments with less-than-ideal supporting features. Dentin-bonded resin cements can help to extend the life of detached prostheses until the patient is financially prepared for replacement or it can help to avoid crown-lengthening surgery.

Crowns↗

Abutment taper of full cast crown preparations by dental students in the UWI School of Dentistry.

Retention of crowns has been shown to be inversely proportional to taper. The objective of this study was to compare the abutment taper of teeth prepared for full veneer crowns by students at the UWI School of Dentistry with those of other dental schools. Twenty five dies were scanned by a Co-ordinate Measuring Machine (CMM) and the mean taper and standard deviations were found to be 20.3 +/- 11.3 degrees mesio-distally and 18.3 +/- 8.5 degrees bucco-lingually. This study shows that the taper achieved by dental students at the UWI School of Dentistry preparing teeth for full veneer crowns is comparable to those achieved by other dental students in the US, UK, Europe and Japan.

Clinical Competence↗

The effect of die spacer on retention and fitting of complete cast crowns.

PURPOSE: This study evaluated the effect of die spacer on the fit and retention of complete cast crowns by using three different cements. MATERIALS AND METHODS: Standardized full crown restoration preparations were completed on 99 extracted molar teeth, impressions were made with poly(vinyl siloxane), and stone dies were made. Dies were covered with four layers of die spacer using three techniques: (1) covering the occlusal and 1/3 of the axial surfaces, (2) covering the occlusal and 2/3 of the axial surfaces, and (3) covering the entire preparation except the apical 0.5 mm of the preparation. Complete metal crowns were cast using Pors-on 4 alloy. Crowns were then assigned to one of three luting agent groups: resin modified glass ionomer cement, resin cement, or zinc phosphate cement. The castings were placed on their respective teeth and the marginal opening was recorded by two methods: 72 specimens were examined before and after cementation using optical microscopy with 0.001 mm resolution, and 27 specimens were examined after cementation with scanning electron microscopy. After cementation, the teeth were thermocycled for 700 cycles between 5 degrees C and 55 degrees C. The tensile retentive strength was measured on a universal testing machine with a crosshead speed of 0.5 mm/min. The data obtained for the fitting were recorded in millimeters and the data for the tensile retentive strength were recorded in KgF. The statistical analysis was performed by analysis of variance and post hoc Tukey's test (p< 0.05). RESULTS: Before cementation, better marginal fit was obtained when the die spacer covered all but the area 0.5 mm short of the margin of the preparation; however, after cementation, the resin modified glass ionomer cement group had the best fit with the same application of die spacer. Castings luted with resin cement required the greatest tensile force to produce cement failure. CONCLUSIONS: Increasing the area of the die surface covered with spacer improved the fit of the cast restoration. After cementation, the resin modified glass ionomer showed better adaptation; however, the optical microscopy and scanning microscopy correlate well. Resin cement had the highest resistance to tensile forces.

Analysis of Variance↗

Cast posts that fit at first try.

The following article describes a procedure that permits the retention of a cast post that will fit passively in the canal at first try. By means of an indirect method, an elastic cast was poured in the master impression and an exact duplicate of the future dowel was formed with self-curing acrylic resin. A stone cast made from a second pour of the impression was then used to adjust the pattern in the laboratory. Posts made with the use of this system routinely sit passively in the root canal without the need of adjustments at the chair. The interval employed in obtaining and adjusting an acrylic resin pattern mentioned in the above way represents less time and effort than trying to make a cast fit in the canal, especially in the case of patients who require multiple posts in the same arch.

Acrylic Resins↗

The effect of the use of 2% chlorhexidine gel in post-space preparation on carbon fiber post retention.

OBJECTIVE: Evaluate the bond strength of a resin cement used to lute carbon fiber posts, when drills and 4 different substances were used for the post-space preparation. STUDY DESIGN: Forty human canines were treated endodontically, and had a 10-mm length post space preparation. Four different substances were used with the drills: G1 -saline, G2 -2% chlorhexidine gel, G3 -EDTA/NaOCl, and G4 -xylene. Carbon fiber posts (C-Post) were cemented with Allbond2 and Hi-X. Then, the posts were dislodged by tensional forces. RESULTS: The groups of chlrohexidine (G2) and xylene (G4) obtained superior average values of bond strength at the 5% significance level (Parametric analyzes ANOVA/Tukey/Scheffe) differing statistically from the other groups. There was no statistical significant difference between groups 2 and 4. CONCLUSION: Xylene and chlorhexidine gel are good substances for the post-space preparation but the second has the advantage of antimicrobial activity and low toxicity.

Analysis of Variance↗

[Vertical alveolar ridge augmentation using distraction osteogenesis].

Alveolar ridge atrophy can be acquired or congenital. Alveolar ridge augmentation can be performed using bone grafting but a donor site morbidity is unavoidable and some resorption of the grafted bone occurs. Distraction osteogenesis offers an alternative method for bone reconstruction without donor site morbidity and sufficient stability of the final results. In order to place implants, vertical alveolar augmentation using Distraction Osteogenesis has been applied to 14 patients aged 17 to 55 years old with edentulous alveolar ridge, 8 in the mandible and 6 in the maxilla. Vertical alveolar bone distraction was started by performing a segmental alveolar osteotomy followed by insertion of a central distraction device--Lead System (Endosseous alveolar distraction system, Leibinger). After three days of latency period, the distraction was started in a rate of 0.8 mm per day for 9 to 16 days as needed. The retention period for the new bone maturation was twice as long as the active distraction period. After removal of the device, 23 cylindrical threaded implants were inserted. The results revealed increase of the alveolar bone height with new bone formation that was observed radiographically and clinically at the removal of the distraction device. The amount of elevation was 7-13 mm. In follow-up of 6-14 months, failure of only one implant was noted, due to inadequate transported bone stability. The advantages of alveolar bone distraction are: Increase of the alveolar bone height with new bone formation, minimal resorption of bone without the bone graft disadvantages. A long term follow up after the bone height achieved and implant anchorage should be performed in the future.

Adolescent↗

Evaluation of two dentin adhesives in cervical lesions.

The clinical effectiveness of two dentin adhesives, Clearfil New Bond and Scotchbond 2, was evaluated in two different cavity designs. Group A was without enamel bevel or acid etch and with a butt-joint cavity; and group B had enamel bevel, acid etch, and feather-edged cavities. The retentive rate and marginal adaptation were monitored for 2 years. In the Clearfil system, 21% of group A restorations failed after 2 years, whereas virtually all the group B restorations (99%) were retained. In addition, after 2 years, the total of debonded group A restorations in the Scotchbond 2 system expanded to 13%, whereas no restorations from group B were lost. There was clearly marginal deterioration in time irrespective of the bonding system. Nevertheless, the marginal adaptation of cervical lesions restored with Clearfil New Bond adhesive in combination with Clearfil Ray composite resin revealed fewer defects compared with the Scotchbond 2 adhesive with Silux Plus composite resin restorations. SEM evaluation disclosed composite resin remnants on the dentin surface in cavities with lost fillings, which indicates partial cohesive failure of the adhesive joint.

Composite Resins↗

Survival of ceramic computer-aided design/manufacturing crowns bonded to preparations with reduced macroretention geometry.

PURPOSE: Adhesive cementation reduces the need for macroretentive preparation for crowns. This study investigated the survival and clinical rating of monolithic computer-aided design/manufacturing (CAD/CAM) ceramic crowns bonded to preparations with reduced macroretention, hypothesizing that adhesion would compensate for reduced retention geometry. MATERIALS AND METHODS: Two-hundred eight posterior CAD/CAM-generated crowns from feldspar block ceramic were adhesively bonded in 136 patients in three preparation groups: classic (100% stump height, n = 70); reduced (reduced stump height or irregular stump, n = 52); and endo (absent stump but pulp chamber retention cavity, n = 86). Crowns were examined at baseline and after 55 +/- 15 months using modified USPHS criteria. Plaque and bleeding of gingiva around the crowns were assessed. RESULTS: Cumulative Kaplan-Meier survival of crowns on premolars/molars was: classic = 97.0%/94.6%; reduced = 92.9%/92.1%; and endo = 68.8%/87.1%, confirming the hypothesis for classic, reduced, and endo molars as well as for classic and reduced premolars. A significant difference was found between classic and endo premolar crowns, rejecting the hypothesis for endo preparation on premolars. Plaque and bleeding indices were significantly lower for crowned teeth than for controls. CONCLUSION: The survival of classic and reduced crowns was rated adequate for premolars and molars. Endo preparation appeared acceptable for molar crowns but inadequate for premolar crowns.

Aluminum Silicates↗

Influence of fatigue loading on four post-and-core systems in maxillary premolars.

OBJECTIVE: Clinical studies show a high failure incidence after years of service of endodontically treated premolars, when restored with post-core crowns, especially those with short posts or deficient ferrules. The reason for this can be a deterioration of the luting cement around the post by fatigue from functional loading. In particular, the anatomy of premolars may frequently be incompatible with the application of long endodontic posts. The aim of this study was to evaluate the influence of fatigue loading on the quality of the cement layer between posts with restricted lengths and the root canal wall in premolars. As the stiffness of posts may affect the outcome, post-and-core systems with varying post stiffness were selected. METHOD AND MATERIALS: Four types of post-and-core systems were selected for this study: three prefabricated post systems combined with a resin composite core material and one cast post and core. The three prefabricated posts were titanium posts (Tenax), quartz-fiber posts (Aestheti-Post), and quartz-coated-carbon-fiber posts (Aestheti-Plus). The post-and-core restorations were made on single-rooted, human, maxillary premolars from which the coronal sections were removed at the level of the proximal cementoenamel junction. Following endodontic treatment, a cast post and core (post length 6 mm) was prepared for each tooth individually (direct method) and cemented into the root canal with chemical cure Panavia 21 TC. The prefabricated posts were directly cemented in the root canal and then, after applying a dual-cure adhesive (Clearfil Photobond), built up with a core build-up composite (Clearfil Photocore). For each group (n = 8), half of the specimens were exposed to fatigue loading (10(6) load cycles) almost perpendicular to the axial axis (85 degrees), while the other half was used as the control. Three parallel, transverse root sections of 1.5-mm thickness, were cut from each specimen. These sections were examined by scanning electron microscopy (SEM) to evaluate the cement integrity, while the retention strength of the cemented post sections was determined with a push-out test. RESULTS: Fatigue loading did not cause separation of the buildups from the roots or affect the push-out strength. On a univariate level, only SEM evaluation showed significant differences between the types of post, fatigue loading, and between the levels of root sections. The cement integrity with the titanium post was significantly less than with the other three systems, which did not differ among themselves. The differences could not be explained by differences in stiffness between the posts. CONCLUSION: A composite core build-up material bonded to the dentin and supported by quartz-fiber posts or quartz-coated-carbon-fiber posts, cemented with adhesive cement like Panavia 21 TC, may be a viable alternative for the conventional cast core.

Bicuspid↗

The effect of immediate versus delayed cementation on the retention of different types of fiber post in canals obturated using a eugenol sealer.

Post can be placed immediately after the completion of the endodontic procedure or at a later stage after setting of the sealer. In this in vitro study, post space preparation and post cementation were performed immediately (group 1), 24 h (group 2), and 7 days (group 3) after root filling. A control group with no root canal obturation was included (group 4). Each group was further divided into three subgroups, according to the post type and to the materials used for luting the post. A push-out test was performed to evaluate post-root canal dentin interfacial strength. Differences among experimental groups were analyzed with two-way ANOVA and the Tukey test. Significant differences (p < 0.05) in interfacial strengths were observed for the factors post cementation interval and post type. Clinicians should be careful in performing immediate cementation of fiber posts, as delayed cementation shows higher post-dentin interfacial strengths irrespective of the post type.

Analysis of Variance↗

The elastic limit of nickel-containing and nickel-free cobalt-chromium circumferential clasp arms.

The purpose of this study was to compare the flexibility and rigidity of the retentive arms of cast circumferential clasps prepared from two nickel-containing alloys (Vitallium and Wironit) with a nickel-free alloy (Biosil). Standardised wax patterns were adapted to 30 specially prepared refractory casts. Ten of these waxed casts were sent to each of three commercial laboratories that specialize in making castings from each of the alloys to be tested. A tensile tester was used to test each one of the finished clasps for deflection at the elastic limit and for load at 0.5 mm deflection. An exploratory analysis of the data by means of a multivariate analysis of variance was followed by Fisher's least significant test that identified specific differences between test specimens. It was found that nickel-containing and nickel-free alloys were not significantly different in respect of flexibility and rigidity.

Chromium Alloys↗

Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years--preliminary results.

PURPOSE: Non-vital endodontically treated posterior teeth with complete loss of coronal hard tissues were prepared with a circular equigingival butt margin and central retention cavity of the entire pulp chamber ("endo-preparation"). Computer-generated ceramic corono-radicular restorations (Cerec endo-crowns) were bonded to these preparations. The purpose of this study was to evaluate the survival rate and the clinical quality of CAD/CIM endo-crowns after 2 years. MATERIALS AND METHODS: 19 Cerec endo-crowns (4 premolars and 15 molars) in 13 patients were examined using modified USPHS criteria at baseline and after an average time of 26 months. The ratings of the two examinations were compared. RESULTS: The service time of the 19 endo-crowns was 14 to 35.5 (mean +/- SD: 26 +/- 6) months. One molar endo-crown failed after 28 months because of recurrent caries. CONCLUSION: The overall clinical quality of the Cerec endo-crowns was very good, and so far, the clinical concept appears feasible.

Aluminum Oxide↗