Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

[New PMMA bone cements for vacuum mixing systems].

In cemented total hip replacement, fractures and cracks in the cement mantle may facilitate mechanical loosening of the prosthesis. Especially large voids and flaws within the cement can cause fatigue fractures. Reduction of cement porosity is a logical step in the attempt to improve the quality and durability of bone cement. An effective reduction of pores during vacuum mixing requires prechilling of Palacos R at 4 degrees C. For easier handling, new bone cements have been developed with characteristics similar to Palacos R, but with no chilling necessary prior to mixing under vacuum. In our study two newly developed bone cements (Palamed G, VersaBond) and a bone cement used widely in clinics (Palacos R) were mixed in three different vacuum mixing systems (Optivac, MixOR, Palamix). Macro-, micro-, and total porosity and bending strength (ISO 5833) were determined. All three mixing systems proved effective in reducing porosity and showed constant mixing results. All cement specimens that we tested fulfilled the ISO requirements for bending strength. VersaBond yielded the lowest porosities, but showed lower viscosity compared to Palacos R and Palamed G. The new cements are equal in vitro to Palacos R with regard to bending strength, but further clinical studies are necessary before widespread use is advisable.

Arthroplasty, Replacement, Hip↗

A study on the effect of wet granulation on microcrystalline cellulose particle structure and performance.

PURPOSE: The aim of this study was to investigate the mechanism of the effect of wet granulation process on the compaction properties of microcrystalline cellulose (MCC). METHODS: MCC alone and with hydroxypropyl cellulose (HPC) as a binder were wet granulated by a high-shear process using different granulation parameters (over- and undergranulated). Overgranulated batches were also ball milled after drying and compared to the unmilled material. MCC starting material and granulation were characterized for particle size distribution, surface area, porosity, and isothermal moisture uptake. Compaction behavior of the MCC and granulations was also studied using a compaction simulator. RESULTS: In all cases, the wet granulation process decreased MCC primary particle porosity. Wet granulation also reduced compactibility of MCC to different degrees. Overgranulated batch with HPC showed the lowest compactibility and was less compactible than the batch without HPC granulated using the same parameters. Ball-milled material showed an increase in porosity and was significantly more compactible than the unmilled granulation from the same batch. CONCLUSIONS: The decrease in MCC compactibility after granulation is associated with the decrease in MCC primary particle porosity and in some cases with the formation of large dense granules as well. Under certain conditions, milling seems to counteract the effect of wet granulation on MCC compactibility.

Adsorption↗

The influence of dispersant concentration on the pore morphology of hydroxyapatite ceramics for bone tissue engineering.

There is a clinical need for synthetic scaffolds that will promote bone regeneration. Important factors include obtaining an optimal porosity and size of interconnecting windows whilst maintaining scaffold mechanical strength, enabling complete penetration of cells and nutrients throughout the scaffold, preventing the formation of necrotic tissue in the centre of the scaffold. To address this we investigated varying slip deflocculation in order to control the resulting porosity, pore size and interconnecting window size whilst maintaining mechanical strength. Hydroxyapatite (HA) porous ceramics were prepared using a modified slip casting process. Rheological measurements of the HA slips were used to identify deflocculation conditions which resulted in changes in the cell and window sizes of the resulting ceramics. Sintered ceramics were characterised by X-ray diffraction (XRD) and scanning electron microscopy (SEM). Pore and window size distribution was determined by SEM. XRD analysis confirmed that the crystal structure remained HA after the sintering process. SEM showed that HA porous ceramics presented a highly interconnected porous network with average pore sizes ranging from 391+/-39 to 495+/-25 microm. The average window size varied from 73+/-5 to 135+/-7 microm. Pore diameters obtained were controllable in the range 200-500 microm. Window sizes were in the range 30-250 microm. The use of dispersant concentration allows pore and window size to be modified whilst maintaining control over porosity demonstrated by a porosity of 85% for seven different dispersant concentrations. The advantage of this approach allows the correlation between the rheological conditions of the slip and the resultant sintered ceramic properties. In particular, optimising the ceramic strength by controlling the agglomeration during the casting process.

Bone Substitutes↗

In vivo behavior of acrylic bone cement in total hip arthroplasty.

Polymethylmethacrylate (PMMA) bone cement serves as the primary fixation material between bone and the prosthetic component in cemented total hip arthroplasty. In vivo degradation of bone cement may lead to a decrease in mechanical properties of PMMA and result in aseptic loosening. However, other factors such as porosity and location of the cement relative to the bone implant interface may also contribute to mechanical behavior in vivo. This study investigated the mechanical properties of Simplex cement retrieved from 43 patients undergoing revision total hip arthroplasty. The time in vivo was between 1 month and 27 years. The variables studied included fracture toughness (KIC), porosity, molecular weight, time in vivo of the cement, and relative in vivo location of the cement with respect to the implant and bone. KIC did not correlate with time in vivo of the samples or with molecular weight. This suggests that time in vivo may not be the limiting factor in the mechanical integrity of the bone cement, A significant and inverse relationship was found between porosity and KIC. This implies that porosity is the most important factor in the mechanical behavior of bone cement during in vivo use.

Arthroplasty, Replacement, Hip↗

Transmission scanning acoustic imaging of human cortical bone and relation with the microstructure.

OBJECTIVE: To investigate and compare the spatial distribution of velocity with that of the microstructural properties (dimension of the haversian canal, percentage of porosity) on cross section of cortical bone. DESIGN: Experimental investigations permitted to quantify variation of acoustic properties related with that of the microstructural properties. BACKGROUND: Transmission ultrasonic techniques have been used in vitro and in vivo to assess the elastic and acoustic properties of Human bone, but few investigated the relationship between their variation with that of the microstructure. METHODS: Two scanning techniques (in transmission with a focused transducer at 5 MHz and an environmental scanning electronic microscope at 20 KV) enabled to obtain the spatial distribution of relative acoustic velocities and the microstructural properties (pore size and porosity). RESULTS: Increase of the velocities is related with the decrease of pore size and porosity. Around the periphery of the sections, the velocities were found to be significantly lower in the posterior side with a significant increase along the length. Radial variations are correlated to the spatial distribution of the microstructure where the endocortical region is more porous compared to the periosteal region. CONCLUSION: Significant alterations of the microstructural properties of the cortical bone reflect small variation of velocity suggesting that the velocities are not so sensitive to microstructural changes. RELEVANCE: These results are of importance for the clinicians and researchers to get a better understanding (advantages and limitation) of the use of ultrasound technique to assess material and structural properties of cortical bone. Our study suggested that velocity could be an index of porosity. Then it would be of interest to improve the clinical assessment of bone quality by describing bone both by a mineralization index and a microstructural index.

Acoustics↗

A material-sparing method for simultaneous determination of true density and powder compaction properties--aspartame as an example.

True density results for a batch of commercial aspartame are highly variable when helium pycnometry is used. Alternatively, the true density of the problematic aspartame lot was obtained by fitting tablet density versus pressure data. The fitted true density was in excellent agreement with that predicted from single crystal structure. Tablet porosity was calculated from the true density and tablet apparent density. After making the necessary measurements for calculating tablet apparent density, the breaking force of each intact tablet was measured and tensile strength was calculated. With the knowledge of compaction pressure, tablet porosity and tensile strength, powder compaction properties were characterized using tabletability (tensile strength versus pressure), compactibility (tensile strength versus porosity), compressibility (porosity versus pressure) and Heckel analysis. Thus, a wealth of additional information on the compaction properties of the powder was obtained through little added work. A total of approximately 4 g of powder was used in this study. Depending on the size of tablet tooling, tablet thickness and true density, 2-10 g of powder would be sufficient for characterizing most pharmaceutical powders.

Aspartame↗

Impact of rainfall intensity on the transport of two herbicides in undisturbed grassed filter strip soil cores.

Two series of displacement experiments with isoproturon and metribuzin herbicides were performed on two undisturbed grassed filter strip soil cores, under unsaturated steady-state flow conditions. Several rainfall intensities (0.070, 0.147, 0.161, 0.308 and 0.326 cm h(-1)) were used. A water tracer (bromide) was simultaneously injected in each displacement experiment. A descriptive analysis of experimental breakthrough curves of bromide and herbicides combined with a modeling analysis showed an impact of rainfall intensity on the solute transport. Two contrasting physical non-equilibrium transport processes occurred. Multiple (three) porosity domains contributed to flow at the highest rainfall intensities, including preferential flow through macropore pathways. Macropores were not active any longer at intermediate and lowest velocities, and the observed preferential transport was described using dual-porosity-type models with a zero or low flow in the matrix domain. Chemical non-equilibrium transport of herbicides was found at all rainfall intensities. Significantly higher estimated values of degradation rate parameters as compared to batch data were correlated with the degree of non-equilibrium sorption. Experimental breakthrough curves were analyzed using different physical and chemical equilibrium and non-equilibrium transport models: convective-dispersive model (CDE), dual-porosity model (MIM), dual-permeability model (DP), triple-porosity, dual permeability model (DP-MIM); each combined with both chemical instantaneous and kinetic sorption.

Diffusion↗

Manufacture of porous biodegradable polymer conduits by an extrusion process for guided tissue regeneration.

We have fabricated porous, biodegradable tubular conduits for guided tissue regeneration using a combined solvent casting and extrusion technique. The biodegradable polymers used in this study were poly(DL-lactic-co-glycolic acid) (PLGA) and poly(L-lactic acid) (PLLA). A polymer/salt composite was first prepared by a solvent casting process. After drying, the composite was extruded to form a tubular construct. The salt particles in the construct were then leached out leaving a conduit with an open-pore structure. PLGA was studied as a model polymer to analyze the effects of salt weight fraction, salt particle size, and processing temperature on porosity and pore size of the extruded conduits. The porosity and pore size were found to increase with increasing salt weight fraction. Increasing the salt particle size increased the pore diameter but did not affect the porosity. High extrusion temperatures decreased the pore diameter without altering the porosity. Greater decrease in molecular weight was observed for conduits manufactured at higher temperatures. The mechanical properties of both PLGA and PLLA conduits were tested after degradation in vitro for up to 8 weeks. The modulus and failure strength of PLLA conduits were approximately 10 times higher than those of PLGA conduits. Failure strain was similar for both conduits. After degradation for 8 weeks, the molecular weights of the PLGA and PLLA conduits decreased to 38% and 43% of the initial values, respectively. However, both conduits maintained their shape and did not collapse. The PLGA also remained amorphous throughout the time course, while the crystallinity of PLLA increased from 5.2% to 11.5%. The potential of seeding the conduits with cells for transplantation or with biodegradable polymer microparticles for drug delivery was also tested with dyed microspheres. These porous tubular structures hold great promise for the regeneration of tissues which require tubular scaffolds such as peripheral nerve, long bone, intestine, or blood vessel.

Biocompatible Materials↗

Measurement of effective air diffusion coefficients for trichloroethene in undisturbed soil cores.

In this study, we measure effective diffusion coefficients for trichloroethene in undisturbed soil samples taken from Picatinny Arsenal, New Jersey. The measured effective diffusion coefficients ranged from 0.0053 to 0.0609 cm2/s over a range of air-filled porosity of 0.23-0.49. The experimental data were compared to several previously published relations that predict diffusion coefficients as a function of air-filled porosity and porosity. A multiple linear regression analysis was developed to determine if a modification of the exponents in Millington's [Science 130 (1959) 100] relation would better fit the experimental data. The literature relations appeared to generally underpredict the effective diffusion coefficient for the soil cores studied in this work. Inclusion of a particle-size distribution parameter, d10, did not significantly improve the fit of the linear regression equation. The effective diffusion coefficient and porosity data were used to recalculate estimates of diffusive flux through the subsurface made in a previous study performed at the field site. It was determined that the method of calculation used in the previous study resulted in an underprediction of diffusive flux from the subsurface. We conclude that although Millington's [Science 130 (1959) 100] relation works well to predict effective diffusion coefficients in homogeneous soils with relatively uniform particle-size distributions, it may be inaccurate for many natural soils with heterogeneous structure and/or non-uniform particle-size distributions.

Air Pollutants↗

Modeling of non-reactive solute transport in fractured clayey till during variable flow rate and time.

Fractures and biopores can act as preferential flow paths in clay aquitards and may rapidly transmit contaminants into underlying aquifers. Reliable numerical models for assessment of groundwater contamination from such aquitards are needed for planning, regulatory and remediation purposes. In this investigation, high resolution preferential water-saturated flow and bromide transport data were used to evaluate the suitability of equivalent porous medium (EPM), dual porosity (DP) and discrete fracture/matrix diffusion (DFMD) numerical modeling approaches for assessment of flow and non-reactive solute transport in clayey till. The experimental data were obtained from four large undisturbed soil columns (taken from 1.5 to 3.5 m depth) in which biopores and channels along fractures controlled 96-99% of water-saturated flow. Simulating the transport data with the EPM effective porosity model (FRACTRAN in EPM mode) was not successful because calibrated effective porosity for the same column had to be varied up to 1 order of magnitude in order to simulate solute breakthrough for the applied flow rates between 11 and 49 mm/day. Attempts to simulate the same data with the DP models CXTFIT and MODFLOW/MT3D were also unsuccessful because fitted values for dispersion, mobile zone porosity, and mass transfer coefficient between mobile and immobile zones varied several orders of magnitude for the different flow rates, and because dispersion values were furthermore not physically realistic. Only the DFMD modeling approach (FRACTRAN in DFMD mode) was capable to simulate the observed changes in solute transport behavior during alternating flow rate without changing values of calibrated fracture spacing and fracture aperture to represent the macropores.

Aluminum Silicates↗

Effect of mixing methods on the compressive strength of glass ionomer cements.

OBJECTIVE: The purpose of the study was to evaluate the effect of the mixing method on the compressive strength and porosity of dental glass ionomer cements. METHOD: Five glass ionomer cements were chosen for use in the study. Two were hand mixed and three were encapsulated. The latter were mixed either by shaking or rotating. Following mixing by rotation some samples were centrifuged before use. The 24h compressive strength was determined for each cement/mixing regime combination and fracture surfaces were examined using SEM. RESULTS: The mixing method had a significant effect on compressive strength (P<0.05). For the luting/lining cement, hand mixing produced a significantly greater compressive strength (P<0.05). For the restorative cement, there were only small differences between specimens mixed by different methods and hand mixing gave a significantly lower compressive strength than mixing by rotation followed by centrifuging (P<0.05). Porosity was incorporated in all samples and low values of compressive strength were associated with larger pores. SIGNIFICANCE: The strength of glass ionomer cements is affected by incorporated porosity and this is dependent on the method of mixing. For some cements hand mixing is favoured in order to reduce porosity and increase strength but this is not generally applicable to all cements.

Capsules↗

Suppression of agglomeration in fluidized bed coating. IV. Effects of sodium citrate concentration on the suppression of particle agglomeration and the physical properties of HPMC film.

We previously reported that sodium citrate (Na citrate), which is a high order salt in the Hofmeister's series, greatly suppressed particle agglomeration in fluidized bed coating (Pharm. Res., 16 (1999), 1616-1620). In this paper, we studied the effects of Na citrate concentration on the particle agglomeration in fluidized bed coating and on the structure of coated film on the particles. Spherical granules made of crystalline cellulose (Celphere) containing phenacetin were coated in a fluidized bed with the aqueous coating solution of hydroxypropylmethyl cellulose (HPMC) containing Na citrate at various concentrations. The particle diameter and drug release profile of coated particles, and the physical properties, i.e. tensile strength, elongation percentage at break, porosity and pore size distribution, of the HPMC cast film were investigated. The particle agglomeration was suppressed with the increasing Na citrate concentration. It is considered that the increase in the suppression effect was caused by the salting-out effect of the increased Na citrate. In the HPMC cast film system, the tensile strength and elongation percentage decreased and the porosity and cumulative pore volume increased with an increase in Na citrate concentration. It is considered that the increase in the porosity by adding Na citrate resulted from a phase separation due to the salting-out during the film forming process. The drug release rate from coated particles also increased with the increasing Na citrate concentration. It can be concluded that the increase in the release rate was due to the increase in porosity of the HPMC coated film caused by the increased Na citrate concentration.

Algorithms↗

Effects of initial particle size on the tableting properties of L-lysine monohydrochloride dihydrate powder.

L-lysine monohydrochloride (LMH) dihydrate was crystallized and the resulting powder was sieved to obtain various size fractions. The influence of other factors, such as crystallinity and crystal shape, was minimized by using the same batch of crystals. Compression of smaller particles at low compaction pressures resulted in tablets of greater porosity. The differences in porosity decreased with increasing compaction pressure. At the same compaction pressure, smaller particles formed tablets of greater tensile strength. However, fragmentation of the larger particles tended to equalize the particle size and reduce its influence. The differences were reduced for particles larger than 710 microm. For crystals of all size fractions, tensile strength increased with increasing compaction pressure. The tensile strength increased more rapidly for smaller crystals. Tensile strength decreased exponentially with increasing porosity for all fractions. The dependence of tensile strength on porosity is explained in term of tablet structure. Yield strength, calculated from 'out-of-die' Heckel analysis, increased with increasing particle size.

Lysine↗

Microstructure of Portland cement pastes containing metal nitrate salts.

In recent years, Backscattered Scanning Electron microscopy techniques (BSE), coupled with an image analysis system have been recognised as a powerful tool for quantitative analysis. This paper investigates the effect of metal additions (Ba, Cu, Ni, Zn, Cr(III), Pb and Cd) to Portland cement to produce a solidified product which meets the durability criteria quantified by the ratio of hydrated products and porosity. In addition, other indicators of the progress of cement hydration such as the bulk density and evaporable water of the solidified products were also measured. Metal concentrations of 0.1 and 1% per weight of cement at a constant water/cement ratio of 0.4 were examined. The same measurements were conducted on control samples of different water/ cement ratio. The results have shown that the control samples at different W/C ratio showed consistent trend in residual cement porosity, density and evaporable water content. It also showed that low dosage of metal nitrate additions can reduce cement hydration by up to 50% and at the same time reduce the observable porosity. Overall, this work has shown that Scanning Electron Microscopy (SEM) and image analysis are powerful tools and could be used to quantify the observable porosity and cement hydration in solidified systems.

Manufactured Materials↗

Evaluation of the in vitro degradation of macroporous hydrogels using gravimetry, confined compression testing, and microcomputed tomography.

This study investigated the in vitro degradation characteristics of macroporous hydrogels based on poly(propylene fumarate-co-ethylene glycol) (P(PF-co-EG)). Four formulations were fabricated to test the effect of porosity and cross-linking density on the degradation of the resulting macroporous hydrogels. Macroporosity was introduced by the addition of sodium bicarbonate and ascorbic acid, the precursors of the carbon dioxide porogen, in the initiation system for the hydrogel cross-linking. Macroporous hydrogels with porosities of 0.80 +/- 0.03 and 0.89 +/- 0.03 were synthesized by the addition of sodium bicarbonate of concentrations 40 and 80 mg/mL and ascorbic acid of concentrations 0.05 and 0.1 mol/L, respectively. Poly(ethylene glycol) diacrylate (PEG-DA) was utilized as a cross-linker. The molecular weight between cross-links had a significant effect on weight loss after 12 weeks, where samples with M(C) of 1,880 +/- 320 synthesized with a P(PF-co-EG):PEG-DA ratio of 3:1 had a significantly greater mass loss due to degradation than those with M(C) of 1,000 +/- 100 synthesized with a P(PF-co-EG):PEG-DA ratio of 1:1. In contrast, porosity played a minimal role in determining the weight loss. Mechanical testing of the hydrogels under confined compression showed a decrease in compressive modulus over the degradation time for all formulations. In addition, an increase in hydrogel equilibrium water content and pore wall thickness was observed with degradation time, whereas the hydrogel porosity and surface area density remained invariant. The results from microcomputed tomography corroborated with the rest of the measurements and indicated a bulk degradation mechanism of the macroporous hydrogels.

Compressive Strength↗

Photoinitiated cross-linking of the biodegradable polyester poly(propylene fumarate). Part II. In vitro degradation.

This study investigated the in vitro degradation of both solid PPF networks and porous PPF scaffolds formed by photoinitiated cross-linking of PPF polymer chains. Three formulations of scaffolds of differing porosity and pore size were constructed by varying porogen size and content. The effects of pore size and pore volume on scaffold mass, geometry, porosity, mechanical properties, and water absorption were then examined. Throughout the study, the solid networks and porous scaffolds exhibited continual mass loss and slight change in length. Porogen content appeared to have the greatest effect upon physical degradation. For example, scaffolds initially fabricated with 80 wt % porogen content lost approximately 30% of their initial PPF content after 32 weeks of degradation, whereas scaffolds fabricated with 70 wt % porogen content lost approximately 18% after 32 weeks of degradation. For all scaffold formulations, water absorption capacity, porosity, and compressive modulus were maintained at constant values following porogen leaching. These results indicate the potential of photo-cross-linked PPF scaffolds in tissue engineering applications which require maintenance of scaffold structure, strength, and porosity during the initial stages of degradation.

Biocompatible Materials↗

Identification and quantification of mineral precipitation in Fe0 filings from a column study.

Thermogravimetric analysis (TGA) combined with X-ray diffraction (XRD) was used to identify mineral phases and determine corrosion rates of granular iron samples from a 2-yr field column study. Similar to other studies, goethite, magnetite, aragonite, and calcite were found to be the major precipitated minerals, with Fe2(OH)2CO3 and green rust as minor phases. Based on TGA-mass spectrometry (MS) analysis, Fe0 corrodes at rates of 0.5-6.1 mmol kg(-1) d(-1) in the high NO3- (up to 13.5 mM) groundwater; this rate is significantly higher than previously reported. Porosity reduction was 40.6%-45.1% for the inlet sand/Fe0 interface and 7.4%-25.6% for effluent samples of two test columns. Normalized for treatment volumes, porosity loss values are consistent with studies that use high levels of SO4(2-) but are higher than those using low levels of corrosive species. Aqueous mass balance calculations yield corrosion rates similar to the TGA-MS method, providing an alternative to coring and mineralogical analysis. A severely corroded iron sample from the column simulating a 17-yr treatment throughput showed >75% porosity loss. Extensive porosity loss due to high levels of corrosive species in groundwater will have significant impact on long-term performance of permeable reactive barriers.

Calcium Carbonate↗

Drug transport across nylon 610 films: influence of synthesis variables.

Nylon 610 is a hydrophilic polymer with considerable potential as a membrane for drug microencapsulation. To better understand drug transport through such membrane, the influence of the solvents and monomers used in the synthesis of nylon films were examined using a full factorial study. Nylon 610 films were synthesized by an interfacial polycondensation reaction using hexamethylenediamine (HD) in the water phase and sebacoyl chloride (SC) in the organic phase, which was a solvent blend of chloroform and trichlorotrifluoroethane at ratios of 1:1, 1:4, and 4:1. Monomer concentrations studied were 0.2, 0.4, and 0.6 M with respect to their appropriate phase, while the monomer ratios were 1:1, 3:1, and 1:3. The molecular weight, porosity, thickness, and crystallinity of the films were characterized. The transport of potassium chloride, hydrocortisone, and m-cresol was studied at 25 degrees C as a function of the synthesis variables. Potassium chloride was selected to measure the porosity of the membrane. Hydrocortisone and m-cresol, a known solvent for nylon 610, were used to study pore and solution-diffusion transport, respectively. The molecular weight of the films was proportional to the chloroform concentration. As the molecular weight increased, film thickness, porosity, and hydrocortisone permeability increased. As the molecular weight decreased, film thickness and porosity decreased, while m-cresol permeability increased. These results can be explained on the basis of HD ability to readily partition into a good solvent such as chloroform permitting high molecular weight polymer to form before precipitation.

Cresols↗