Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Knee Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Failure of the porous-coated anatomic prosthesis in total knee arthroplasty due to severe polyethylene wear.

Four hundred and eighty-seven total knee arthroplasties were performed by a single surgeon with use of a porous-coated anatomic prosthesis between 1982 and 1989. There were thirty-two clinical failures (7 per cent) due to severe wear of the surfaces of the tibial and patellar polyethylene components. Thirty patients had a revision. The average time to failure of the implant was four and one-half years. The initial clinical symptoms of failure by wear consisted of a painless effusion with a decreased range of motion. Subsequent pain was considered as the criterion for failure necessitating operative intervention. Increased weight and decreased age of the patient and a thinner tibial component were significant predictors of an increased risk of failure (p < 0.01). Examination of retrieved tibial components revealed extensive delamination caused by fracture of the polyethylene at a depth of about one millimeter below the surface. Cracks that had propagated in from the medial and lateral peripheries of the tibial component toward the center of the condyles were also a common finding. It appears that the design of the implant as well as clinical factors (the age and weight of the patient) contributed to the mechanical failure of the polyethylene of these implants.

Aged↗

Dissecting popliteal cyst resulting from a fragmented, dislodged metal part of the patellar component after total knee arthroplasty.

Dissecting popliteal cyst is an uncommon complication after total knee arthroplasty, occurring mainly as a result of either rheumatoid arthritis or a malfunctioning knee prosthesis. Its association with a failed metal-backed patellar component has not been reported since the introduction of the resurfacing of the patella with this kind of design in 1980. We present a case of a late fracture-dislocation of the metal part of the patellar component that migrated to the posterior popliteal fossa, resulting in a cystic mass formation caused by a foreign body granuloma. The patient was treated successfully with a 2-stage operation: first, revision of the total knee arthroplasty and, second, excision of the cyst. The patient had a pain-free functional knee 7 years after surgery, with no recurrence of the symptoms or the popliteal cyst.

Aged↗

Use of Van Nes rotationplasty to manage a burnt knee.

An 11 month old child sustained a deep burn injury to the left knee causing total destruction and sequestration of the knee epiphyses. The ensuing leg length discrepancy with growth was managed by a Van Nes rotationplasty at age four with a good immediate functional result using a below 'knee' prosthesis and the prospect of continuing ambulation as he grows. The surgical options for managing this problem are discussed.

Artificial Limbs↗

The selection of amputation level: an approach using decision analysis.

The choice of level for a major amputation of the leg depends upon the careful balancing of the advantages of preserving the knee joint against the risks of failure to heal and subsequent revision of the amputation stump. A study has been carried out to measure the values that health care professionals put upon different levels of disability resulting from amputation. The results show that the reduction of quality of life is thought to be 5-10% and 10-20%, respectively, for ambulation upon a below-knee and above-knee prosthesis and about 50% for failure to mobilise on an artificial limb. These utilities have been incorporated into a decision analysis to determine the optimum strategy for evaluation of amputation level, with other probabilities obtained from published data. The results demonstrate the advantage of attempting to preserve the knee joint, even if the chance of primary healing is as low as 20%. Tests of likely healing are most useful if the sensitivity is high, with specificity being less important, and the advantages may be outweighed by the costs of false negatives if sensitivity is below 90%. Sensitivity analysis shows that these findings remain valid over a wide range of possible values. Further research is required to gain more accurate information on which to base decisions, but on current evidence a policy of below-knee amputation in all cases of clinical doubt may be preferable to the use of currently available tests.

Amputation, Surgical↗

The orthotic management of the congenitally short lower limb--a new appliance.

AIM: To describe an appliance used for equalisation of severe congenital lower limb length discrepancy for patients who refuse to undergo any operative correction but wish to walk and look better. METHOD: The appliance which is a combination of an ischial bearing brace and a below knee prosthesis was fitted to four patients, aged between 12 and 31 years, with congenital shortening of the lower limb ranging between 17 to 27 centimetres. The diagnosis was proximal femoral focal deficiency in 2 patients, hypoplastic femur in 1 and tibial hemimelia in the fourth patient. The appliance could accommodate existing deformities of the knee, ankle and foot without any operative correction as well as equalise the lower limb length. It is modular in construction and could be easily assembled from off-the-shelf components. RESULT: The appliance improves the gait as well as the appearance, could be fitted to the patient without the prior need of operative correction and could be well disguised under any loose fitting garment. Four patients with severe congenital shortening of the leg have used it for over three years and are pleased with it. It requires little maintenance. CONCLUSION: The appliance is useful for patients with severe congenital shortening of the lower limb who refuse to undergo operative correction.

Adolescent↗

Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty.

UNLABELLED: Fractures of the femur after a knee or hip arthroplasty historically have been plagued with high complication rates. The Less Invasive Stabilization System (LISS) has theoretical advantages of improved biomechanics and limited insult to the bone's vascular supply. We theorized that the LISS would have a lower complication rate than historical controls for these fractures. Patients who were treated with a LISS at two Level I trauma centers from July 2001 to July 2003 were prospectively followed up. The inclusion criteria were an acute fracture of the femur treated with a LISS in a patient with a stable ipsilateral total knee prosthesis and/or hip pros- thesis. There were 24 patients in the study group. The injury mechanism was a low-energy fall for all patients. All patients were females with an average age of 79.5 years (range. 64-93 years). Ten patients had ipsilateral hip arthroplasties, nine patients had ipsilateral total knee arthroplasties, and five patients had knee and hip arthroplasties. Followup was at an average of 48 weeks (range, 17-101 weeks). Eighteen of the 19 fractures in the surviving patients with followup healed uneventfully for a complication rate of 5.2%. One fracture was complicated by hardware pullout and was revised to a longer LISS that healed uneventfully. We think our data show that our patients had a low complication rate compared with that of historical controls, and we suggest that the LISS may be an appropriate treatment alternative for femur fractures associated with stable hip or knee prostheses. LEVEL OF EVIDENCE: Therapeutic, Level IV.

Accidental Falls↗

Quantitative Assessment of Polyethylene Component Position in a Mobile-Bearing Prosthetic Knee, Using a Single Radiograph.

Rationale and Objectives. To reduce tibio-femoral misalignment, the polyethylene bearing-component of a new knee prosthesis was allowed limited motion on the underlying metallic component. The object of the work presented here was to develop a suitable radiographic technique for quantifying the in-vivo position of the bearing. By collecting these data at discrete flexion angles, the functional operation of the prosthesis could be determined. Methods. The known geometries between landmarks on the two components were used to produce algorithms for reconstructing their spatial positions from a single radiograph. A custom-designed computer program utilized these algorithms to determine the relative translation and rotation of the polyethylene component. Results. This technique produced typical errors of 0.54 mm translation and 0.56 degrees rotation between the polyethylene component and the underlying metallic component. Conclusions. A practical method has been developed for assessing mobile-bearing motion, in vivo. This method can be applied to other prosthetic devices, or combinations of components, once the requirement for identifiable landmarks has been addressed. Clinical Relevance. Skeletal and soft-tissue changes in the pathological knee may produce abnormal rotations and translations in the transverse tibial plane. This technique is intended both to validate the design philosophy of a mobile-bearing prosthesis and to provide additional data on any pathological motions, which will have implications for future prosthetic designs.

Journal Article↗

[Transfer of the posterior femoral condyle. First experience with a salvage operation].

In this study large osteochondral defects on the weight-bearing surface of the medial and lateral femoral condyle were treated by transplantation of the autologous posterior condyle in 20 patients. The cartilage defects, type Outerbridge IV, ranged in size from 2 x 1.5 cm to 5 x 3.5 cm. 8 condyle transfers were done from 1984-1996 at the orthopaedic clinic of the university of Balgrist, Zürich. 12 condyle transfers at the department of orthopedic sports medicine at the technical university of Munich from 1996-1998. Patients were operated before the condyle transfer, 2 times on average. In 9 patients a high tibial osteotomy was performed simultaneously. Clinical evaluation was done according to the Lysholm score. The Lysholm score improved in the patient serie from 1996 from preoperatively 62 (54-81) points to postoperatively 85 (74-95) points. The follow-up was on average 9.8 (2-26) months. 18 patients reported about pain relief, 2 patients didn't improve. We describe the operative technique. Despite the lack of long-term results the transfer of the autologous posterior condyle seems to be an effective alternative for the knee prosthesis, especially for young patients with a great cartilage damage in the weight bearing area.

Adolescent↗

[Pain-function indices for the follow-up of osteoarthritis of the hip and the knee].

Algo-functional or severity index for hip diseases (AFIH), proposed in 1980 and validated in 1981, and algo-functional or severity index for knee diseases (AFIK), validated in 1985-1987, were applied to osteo-arthritis of the hip and of the knee. With strictly standardized interviews and well-trained investigators (20 to 30 patients), these indices are reliable: the interobserver reproducibility is good (mean discrepancy: 1/2 point) and the score usually decreases 3 points (mean) under active drug treatment. Each index was individually validated. The severity index for hip is more discriminant than that for knee diseases. The place of each index among the other assessment tests was appraised according to their discriminant capacity. These indices are useful: 1) for drug trials (analgesics and NSAIDs); 2) for the long term follow-up and the so-called chondroprotective agents trials; 3) for a rational decision concerning hip or knee prosthesis (score reaching 8 to 12 points). These AFIH and AFIK are well suited to daily practice and are not time-consuming: 3 to 4 minutes for each.

Cross-Sectional Studies↗

Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis.

Femoral component malalignment is one of the main causes of persisting anterior knee pain after knee replacement. This study examined interindividual reproducibility in perioperative definition of the transepicondylar axis (TEA) as a reference for measuring the rotational alignment of the femoral component. Eight surgeons experienced in knee prosthetic surgery marked on Thiel-embalmed cadaver specimens the reference points that they would normally use to define the TEA during knee replacement. These were digitized by a video system, and all the spots defined by the surgeon were translated into a reference picture, allowing a digital analysis of the distances between all the spots marked. The maximal distance between the spots that the participants had marked as relevant for the TEA was 13.8 mm at the lateral and 22.3 mm at the medial epicondyle. Projecting all spots marked into one picture resulted in an area of 116 mm2 on the lateral and 102 mm2 on the medial epicondyle. The median range of the fault between two different participants was 6.4 mm on the lateral side (range 13.2 mm) and 9.7 mm on the medial (range 21.6 mm). Because the rotational alignment of the femoral component is extremely relevant for successful implantation of total knee prosthesis, the interindividual discrepancy in defining the TEA as reference is rather high. As this reference line is commonly used, the perioperative variance and the resulting rotational discrepancy of the femoral component must be considered.

Arthroplasty, Replacement, Knee↗

[Disarticulation of the knee. Surgical technic--prosthesis fitting].

The authors describe a modified technique for knee joint disarticulation surgery. Their approach provides two flaps, one medial and one lateral, which result in a posterior, longitudinal scar that remains outside the contact areas of the prosthesis. They abrade the lateral and posterior aspect of each condyle, peeling out the articular cartilage and re-covering the condyles with the joint capsule. This technique allows a satisfactory stability in prosthetic rotation, and improves the appearance of the artificial limb. For post-operative rehabilitation the authors use a tridimensional alignment jig and a prosthetic ankle with three degrees of freedom: flexion-extension, lateral-medial motion and rotation, making easier the swing phase while maintaining the obvious advantages of a pilon-type prosthesis.

Amputation, Surgical↗

Bone assessment after total knee arthroplasty by dual-energy X-ray absorptiometry: analysis protocol and reproducibility.

Bone quality is important for the success of joint prostheses implantation, and the assessment of bone density after total knee arthroplasty by means of dual-energy X-ray absorptiometry may be useful for monitoring implant stability. The aim of this study is to suggest a validated analysis protocol for the assessment of bone status after total knee arthroplasty. A dedicated densitometric analysis protocol of five regions of interest was designed, and 10 subjects who had received an uncemented knee prosthesis (8 females and 2 males, aged 55-74 years) underwent three consecutive scans in posteroanterior and lateral projections, with repositioning after each scan to test the suitability and reproducibility of the protocol. The reproducibility of the measurement of bone mineral content and density in the femoral and tibial regions ranged, respectively, from 2.1% to 4.1%, from 0.9% to 2.6% for the posteroanterior scans, and from 2.7% to 5.6% and from 2.3% to 4.7% for the lateral scans, depending on the considered region. Our results confirm that the suggested protocol allows precise assessment of bone mineral content and density, and that dual-energy X-ray absorptiometry is reliable for the evaluation of bone mass around prosthetic implants.

Absorptiometry, Photon↗