Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Isotopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Estimating the latitudinal origins of migratory birds using hydrogen and sulfur stable isotopes in feathers: influence of marine prey base.

Hydrogen stable isotope analysis of feathers is an important tool for estimating the natal or breeding latitudes of nearctic-neotropical migratory birds. This method is based on the latitudinal variation of hydrogen stable isotope ratios in precipitation in North America (deltaD(p)) and the inheritance of this variation in newly formed feathers (deltaD(f)). We hypothesized that the typically strong relationship between deltaD(p) and deltaD(f) would be decoupled in birds that forage in marine food webs because marine waters have relatively high deltaD values compared to deltaD values for local precipitation. Birds that forage on marine prey bases should also have feathers with high delta(34)S values, since delta(34)S values for marine sulfate are generally higher than delta(34)S values in terrestrial systems. To examine this potential marine effect on feather stable isotope ratios, we measured deltaD and delta(34)S in the feathers of nine different species of raptors from both inland and coastal locations across North America. Feathers from coastal bird-eating raptors had consistently higher deltaD and delta(34)S values than feathers from inland birds. Birds that had high delta(34)S values also deviated strongly from the typical relationship between deltaD(p) and deltaD(f). We recommend measuring both sulfur and hydrogen stable isotope ratios in feathers when some members of a migrant population could potentially forage in marine habitats. We suggest using a practical cutoff of delta(34)S >10 per thousand to remove marine-foraging birds from a migrant sample when using stable isotopes of hydrogen to estimate the latitudinal origins of migrants because high deltaD(f) values for marine-foraging birds could potentially distort estimates of origins.

Animals↗

Combining sources in stable isotope mixing models: alternative methods.

Stable isotope mixing models are often used to quantify source contributions to a mixture. Examples include pollution source identification; trophic web studies; analysis of water sources for soils, plants; or water bodies, and many others. A common problem is having too many sources to allow a unique solution. We discuss two alternative procedures for addressing this problem. One option is a priori to combine sources with similar signatures so the number of sources is small enough to provide a unique solution. Aggregation should be considered only when isotopic signatures of clustered sources are not significantly different, and sources are related so the combined source group has some functional significance. For example, in a food web analysis, lumping several species within a trophic guild allows more interpretable results than lumping disparate food sources, even if they have similar isotopic signatures. One result of combining mixing model sources is increased uncertainty of the combined end-member isotopic signatures and consequently the source contribution estimates; this effect can be quantified using the IsoError model (http://www.epa.gov/wed/pages/models/isotopes/isoerror1_04.htm). As an alternative to lumping sources before a mixing analysis, the IsoSource mixing model (http://www.epa.gov/wed/pages/models/isosource/isosource.htm) can be used to find all feasible solutions of source contributions consistent with isotopic mass balance. While ranges of feasible contributions for each individual source can often be quite broad, contributions from functionally related groups of sources can be summed a posteriori, producing a range of solutions for the aggregate source that may be considerably narrower. A paleo-human dietary analysis example illustrates this method, which involves a terrestrial meat food source, a combination of three terrestrial plant foods, and a combination of three marine foods. In this case, a posteriori aggregation of sources allowed strong conclusions about temporal shifts in marine versus terrestrial diets that would not have otherwise been discerned.

Algorithms↗

Extreme isotopic depletion of nitrogen in New Zealand lithophytes and epiphytes; the result of diffusive uptake of atmospheric ammonia?

Several lichens and the terrestrial alga Trentepohlia were found to have extremely depleted 15N signatures at two sites near the Rotorua geothermal area, New Zealand. Values, typically -20 per thousand, with several extreme cases of -24 per thousand, are more isotopically depleted than any previously quoted delta15N signature for vegetation growing in natural environments. For Trentepohlia, distance from a geothermal source did not affect isotopic signature. A 100-km transect showed that the phenomenon is widespread and the discrimination is not related to substrate N, or to elevation. Rainfall NHx and atmospheric gaseous NH3 (NH3(g)) were shown to be isotopically depleted in the range -1 per thousand to -8 per thousand and could not, of themselves, be responsible for the plant values obtained. A simulation of Trentepohlia thallus was created using an acidified fiberglass mat and was allowed to absorb NH3(g) from the atmosphere. Mats exposed at the geothermal sites and on farm-land showed a significant further depletion of 15N to -17 per thousand. We hypothesize that the extreme isotopic depletion is due to dual fractionation: firstly by the volatilization of NH3(g) from aqueous sources into the atmosphere; secondly by the diffusive assimilation of that NH3(g) into vegetation. We further hypothesize that lithophytes, epiphytes, and higher plants, growing on strongly N-limited substrates, will show this phenomenon more or less, depending on the proportion of diffusively assimilated NH3(g) utilized as a N source. Many of the isotopically depleted delta15N signatures in vegetation, previously reported in the literature, especially epiphytes, may be due to this form of uptake depending on the concentration of atmospheric NH3(g), and the degree of reliance on that form of N.

Air Pollutants↗

Controlling for anthropogenically induced atmospheric variation in stable carbon isotope studies.

Increased use of stable isotope analysis to examine food-web dynamics, migration, transfer of nutrients, and behavior will likely result in expansion of stable isotope studies investigating human-induced global changes. Recent elevation of atmospheric CO2 concentration, related primarily to fossil fuel combustion, has reduced atmospheric CO2 delta13C (13C/12C), and this change in isotopic baseline has, in turn, reduced plant and animal tissue delta13C of terrestrial and aquatic organisms. Such depletion in CO2 delta13C and its effects on tissue delta13C may introduce bias into delta13C investigations, and if this variation is not controlled, may confound interpretation of results obtained from tissue samples collected over a temporal span. To control for this source of variation, we used a high-precision record of atmospheric CO2 delta13C from ice cores and direct atmospheric measurements to model modern change in CO2 delta13C. From this model, we estimated a correction factor that controls for atmospheric change; this correction reduces bias associated with changes in atmospheric isotopic baseline and facilitates comparison of tissue delta13C collected over multiple years. To exemplify the importance of accounting for atmospheric CO2 delta13C depletion, we applied the correction to a dataset of collagen delta13C obtained from mountain lion (Puma concolor) bone samples collected in California between 1893 and 1995. Before correction, in three of four ecoregions collagen delta13C decreased significantly concurrent with depletion of atmospheric CO2 delta13C (n > or = 32, P < or = 0.01). Application of the correction to collagen delta13C data removed trends from regions demonstrating significant declines, and measurement error associated with the correction did not add substantial variation to adjusted estimates. Controlling for long-term atmospheric variation and correcting tissue samples for changes in isotopic baseline facilitate analysis of samples that span a large temporal range.

Atmosphere↗

Erythrocyte differentiation of naturally occurring isotopic lithium abundances.

Lithium is effective in the treatment of mania. There are two naturally occurring stable lithium isotopes, Li-7 (92.6%) and Li-6 (7.4%). Usually there is little differentiation between isotopes of an element, but chemical and behavioural data suggest dissimilarities exist between lithium isotopes. Results are now reported indicating that a group of manic patients given lithium chloride were able to differentiate Li-6 from Li-7 at the membrane level. Blood samples were drawn, erythrocytes separated from plasma and the isotopic abundances of Li-6 and Li-7 determined by atomic absorption spectrophotometry. The ratio of abundances of Li-6 in the erythrocyte and plasma was 1.274 indicating the erythrocyte membrane had the in vivo capability of isotope fractionation.

Adult↗

Isotope effects associated with the anaerobic oxidation of sulfite and thiosulfate by the photosynthetic bacterium, Chromatium vinosum.

The purple photosynthetic bacterium Chromatium vinosum, strain D, catalyzes several oxidations of reduced sulfur compounds under anaerobic conditions in the light: e.g., sulfide --> sulfur --> sulfate, sulfite --> sulfate, and thiosulfate --> sulfur + sulfate. Here it is shown that no sulfur isotope effect is associated with the last of these processes; isotopic compositions of the sulfur and sulfate produced can differ, however, if the sulfane and sulfonate positions within the thiosulfate have different isotopic compositions. In the second process, an observed change from an inverse to a normal isotope effect during oxidation of sulfite may indicate the operation of 2 enzymatic pathways. In contrast to heterotrophic anaerobic reduction of oxidized sulfur compounds, anaerobic oxidations of inorganic sulfur compounds by photosynthetic bacteria are characterized by relatively small isotope effects.

Anaerobiosis↗

Glucose isotope, carbon recycling, and gluconeogenesis using [U-13C]glucose and mass isotopomer analysis.

Experimental determinations of glucose carbon recycling using 14C or 13C glucose tracer often underestimate true Cori cycle activity because of dilution and exchange of isotope tracer through the tricarboxylic acid (TCA) cycle. The term glucose isotope recycling therefore is used to distinguish recycling of isotope from recycling of glucose carbon, the actual quantity of circulating glucose recycled. Recently, per-labeled glucose ([U-13C6]glucose) has been used to estimate glucose appearance rate and glucose isotope recycling. Chemical structural information determined by mass isotopomer analysis has been used to correct for dilution of isotope through the TCA cycle. In this report, we present experiments in the study of glucose turnover and recycling using [U-13C6]glucose. Methods of single injection and continuous infusion of [U-13C6]glucose are compared. A formula for the calculation of a dilution factor using TCA cycle parameters is derived. In this study of six rabbits, glucose turnover rate ranged from 3.4 to 8.8 mg/kg/min, and glucose m + 3 mass isotopomer recycling from 7 to 12%. The rate of pyruvate carboxylation (Y) was comparable to that of citrate synthetase, having an average relative flux of 0.89. Applying the correction factor for tracer dilution to the observed mass isotopomer recycling, we determined glucose carbon recycling (or Cori cycle activity) to be 22-35% of hepatic glucose output.

Animals↗

The use of cotton balls to collect infant urine samples for 2H/1H and 18O/16O isotope ratio measurements.

To test the validity of cotton balls as a urine collection medium for hydrogen and oxygen isotope ratio measurements, we moistened cotton balls with 1-, 5-, and 10-mL aliquots of urine that contained either natural abundances or one of two enriched levels of 2H and 18O. The liquids were then expressed from the cotton balls, either at once, or after 30 or 60 min of atmospheric exposure, and analyzed for their 2H/1H and 18O/16O isotope ratios. The 2H abundances of the fluids expressed from the cotton balls were significantly lower than the original values. This dilution of 2H, however, diminished in the samples that had a greater volume of urine. We observed no effects of volume or time on 18O. Our results indicate that at low urine volumes, ambient moisture dilutes 2H in the cotton balls, but isotope exchanges and evaporation have little or no effect on the hydrogen and oxygen isotopic abundances of the urine samples. Total body water and energy expenditure values calculated from the 2H and 18O enrichments of 5- and 10-mL urine samples were within 1% of the theoretical values. Therefore, cotton balls are suitable for collection of infant urine samples for hydrogen and oxygen isotope ratio measurements, if the volume of urine that can be expressed from a cotton ball is > or = 5 mL.

Adult↗

Solvent isotope effects on alpha-glucosidase.

The solvent kinetic isotope effects (SKIE) on the yeast alpha-glucosidase-catalyzed hydrolysis of p-nitrophenyl and methyl-d-glucopyranoside were measured at 25 degrees C. With p-nitrophenyl-D-glucopyranoside (pNPG), the dependence of k(cat)/K(m) on pH (pD) revealed an unusually large (for glycohydrolases) solvent isotope effect on the pL-independent second-order rate constant, (DOD)(k(cat)/K(m)), of 1.9 (+/-0.3). The two pK(a)s characterizing the pH profile were increased in D(2)O. The shift in pK(a2) of 0.6 units is typical of acids of comparable acidity (pK(a)=6.5), but the increase in pK(a1) (=5.7) of 0.1 unit in going from H(2)O to D(2)O is unusually small. The initial velocities show substrate inhibition (K(is)/K(m) approximately 200) with a small solvent isotope effect on the inhibition constant [(DOD)K(is)=1.1 (+/-0.2)]. The solvent equilibrium isotope effects on the K(is) for the competitive inhibitors D-glucose and alpha-methyl D-glucoside are somewhat higher [(DOD)K(i)=1.5 (+/-0.1)]. Methyl glucoside is much less reactive than pNPG, with k(cat) 230 times lower and k(cat)/K(m) 5 x 10(4) times lower. The solvent isotope effect on k(cat) for this substrate [=1.11 (+/-0. 02)] is lower than that for pNPG [=1.67 (+/-0.07)], consistent with more extensive proton transfer in the transition state for the deglucosylation step than for the glucosylation step.

Buffers↗

Carbon and nitrogen composition and stable isotope as potential indicators of source and fate of organic matter in the salt marsh of the Changjiang Estuary, China.

Elemental (TOC, TN, C/N) and stable carbon and nitrogen isotopic (delta(13)C, delta(15)N) compositions were measured for surface sediments, three sediment vibrocores, plants, and suspended particulate matter (SPM) collected from salt marsh of the Changjiang Estuary. The purpose of this study is to characterize the sources of organic matter in sediments and to further elucidate the factors influencing the isotope signature in the salt marsh. Our results indicate that organic matter preserved in the sediments is predominantly controlled by the particulate organic matter in the Changjiang Estuary. The in situ contribution of marsh plants carbon to sediment organic matter is clearest in the high marsh, where the low delta(13)C of the plants (-28.1 per thousand) is reflected by a sediment delta(13)C (-24.7 per thousand) lower than values found for the low marsh and bare flat sediments (-23.4 per thousand and -23.0 per thousand, respectively). The effect of grain size on the spatial difference of isotope composition in the marsh sediments is insignificant, based on the observation that similar isotope values are found in different size particles, both for delta(13)C and delta(15)N. Nutrient utilization by plant assimilation, however, shows great impact on the surface sediment delta(15)N composition, due to the isotope fractionation. With extensive plant coverage and the consequent low surface water nitrate concentration, delta(15)N values of the high marsh surface sediments show (15)N enrichment.

Carbon↗

Observation of cerium isotope fractionation in ion-exchange chromatography of Ce(III)-malate complex.

The cerium isotope fractionation between Ce(III)-malate complex in aqueous solution and cerium ions in a cation-exchange resin was conducted by displacement chromatography. The pH and the chemical composition of the eluent were optimized for maintaining the self-sharpening band boundaries and the 21 m chromatographic migration of the Ce band underwent. Graphite slurry was coated on the tantalum filament prior to sample loading for reducing the isobaric interferences in cerium isotopic ratio determination by mass spectrometry. From the experimental results, it was found that the heavier isotope was enriched in the front boundary part of the cerium adsorption band, which meant that the heavier isotope was preferentially fractionated into the Ce3+ malate complex rather than simply hydrated Ce3+ ions. The isotope separation coefficient for the 136Ce/140Ce and 142Ce/140Ce was 5.2 x 10(-5) and -1.9 x 10(-5), respectively, at 298 K.

Cerium Isotopes↗

Chlorine isotope fractionation of a semi-volatile organochlorine compound during preparative megabore-column capillary gas chromatography.

Chlorine isotope fractionation during preparative capillary gas chromatography (pcGC) was investigated using 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT) as a model compound for semi-volatile organochlorine (OCl) molecules. Chlorine isotope analysis by thermal ionization mass spectrometry revealed no significant alteration of the chlorine isotope composition when the whole peaks were collected in pcGC (delta37Cl -3.2 per thousand versus -3.6 per thousand for the unprocessed DDT, +/-0.5 per thousand SD). However, distinct isotope fractionations were measured for the front (delta37Cl -5.1 per thousand) and tail (delta37Cl -1.8 per thousand) segments of partially collected samples. Isolation of individual OCls by pcGC enables accurate off-line chlorine isotope analysis, and thus facilitates the investigation of naturally occurring OCls.

Chlorine↗

An automated method for the analysis of stable isotope labeling data in proteomics.

An algorithm is presented for the generation of a reliable peptide component peak table from liquid chromatography-mass spectrometry (LC-MS) and subsequent quantitative analysis of stable isotope coded peptide samples. The method uses chemical noise filtering, charge state fitting, and deisotoping toward improved analysis of complex peptide samples. Overlapping peptide signals in mass spectra were deconvoluted by correlation with modeled peptide isotopic peak profiles. Isotopic peak profiles for peptides were generated in silico from a protein database producing reference model distributions. Doublets of heavy and light labeled peak clusters were identified and compared to provide differential quantification of pairs of stable isotope coded peptides. Algorithms were evaluated using peptides from digests of a single protein and a seven-protein mixture that had been differentially coded with stable isotope labeling agents and mixed in known ratios. The experimental results correlated well with known mixing ratios.

Algorithms↗

Studies on zinc bioavailability from a representative diet in Chinese urban women of childbearing age using a double label stable isotope technique.

The objectives of the study were to determine dietary zinc bioavailability by using a double label stable isotope technique, and to identify the zinc content and levels of some possible factors which may affect zinc utilization in a typical representative Chinese urban diet. Twenty urban women of childbearing age were fed a diet extrinsically labeled with 67Zn and received intravenous (i.v.) injections of 70Zn. Fecal monitoring, urine monitoring and chemical balance technique were used simultaneously for comparisons. Isotopic enrichment in feces and urine after oral and i.v. administration of stable zinc isotopes was measured to determine the ways of zinc absorption. The mean (+/-SD) zinc intake from the representative Chinese diet was 10.22+/-0.80 mg/day, which is lower than the reference nutrient intake (RNI) level (11.5 mg/day), and mainly came from the subsidiary foods (63%). The mean dietary Fe/Zn weight was 1.1+/-0.1. The phytate/zinc molar ratio in the diet was about 3:1. The phytic acidxCa/zinc molar ratio in the diet was about 45:1. The apparent and true absorption rates of 67Zn were 36.2+/-9.7% and 38.2+/-10.1%, respectively, which were higher than the apparent absorption determined by balance technique (29.7+/-10.6%). The mean fractional absorption (FA) determined in urine was 35.7+/-13.3. In conclusion, the subsidiary food is the main source of dietary zinc in this typical diet. The extrinsic labeling technique by use of stable isotopes was more reliable and accurate to determine zinc absorption. Moreover, the double isotopic tracer ratio (DITR) technique applied to urine samples was a more practical and valuable way to evaluate zinc absorption than other methods. It can be speculated that iron and phytic acid might not be the main inhibitors in the representative Chinese diet.

Absorption↗

Basic principles of metabolic modeling of NMR (13)C isotopic turnover to determine rates of brain metabolism in vivo.

Metabolic modeling is a necessary part of the analysis of isotopic labeling data that is being obtained in the brain and other organs. Here are explained the basic principles of metabolic modeling of isotopic labeling studies, particularly with regard to (13)C isotopic measurements performed in vivo. The basic elements needed to simulate isotopic flows are described, and how to combine them to perform modeling analyses is explained. Procedures to introduce and evaluate model constraints and simplifications are discussed. The basic principle of isotopomer analysis is explained, as are mechanics of least-squares fitting of simulations to data. Closely related to the fitting is the effect of data scatter, which is discussed in the context of the non-normal distributions of uncertainty that are often seen with (13)C labeling measurements in vivo. This article is meant to provide a general background for investigators to begin to apply metabolic modeling analysis to (13)C isotopic labeling studies performed in vivo.

Brain↗

Origin of magnetite in oxidized CV chondrites: in situ measurement of oxygen isotope compositions of Allende magnetite and olivine.

Magnetite in the oxidized CV chondrite Allende mainly occurs as spherical nodules in porphyritic-olivine (PO) chondrules, where it is associated with Ni-rich metal and/or sulfides. To help constrain the origin of the magnetite, we measured oxygen isotopic compositions of magnetite and coexisting olivine grains in PO chondrules of Allende by an in situ ion microprobe technique. Five magnetite nodules form a relatively tight cluster in oxygen isotopic composition with delta 18O values from -4.8 to -7.1% and delta 17O values from -2.9 to -6.3%. Seven coexisting olivine grains have oxygen isotopic compositions from -0.9 to -6.3% in delta 18O and from -4.6 to -7.9% in delta 17O. The delta 17O values of the magnetite and coexisting olivine do not overlap; they range from -0.4 to -2.6%, and from -4.0 to -5.7%, respectively. Thus, the magnetite is not in isotopic equilibrium with the olivine in PO chondrules, implying that it formed after the chondrule formation. The delta 17O of the magnetite is somewhat more negative than estimates for the ambient solar nebula gas. We infer that the magnetite formed on the parent asteroid by oxidation of metal by H2O which had previously experienced minor O isotope exchange with fine-grained silicates.

Ferrosoferric Oxide↗

Stable isotope labeling of lead compartments in rats with ultralow lead concentrations.

The role of the mammalian skeleton as an endogenous lead source is unclear. This is due in part to difficulties in distinguishing mobilized skeletal lead from other endogenous and exogenous lead sources. Therefore, we have applied ultraclean stable lead isotope techniques to label skeletal and soft tissue lead compartments within the rat with distinguishable lead isotopic signatures. Female Wistar (defined flora) rats were fed 206Pb-enriched drinking water ([Pb] = 110 ng/ml) and sacrificed after durations of 2, 4, 7, and 14 days. Blood, kidney, vertebra, and tibia tissues were analyzed for lead concentrations and stable isotopic compositions. The resulting isotopic ratios in soft (blood and kidney) and skeletal (vertebrae and tibia) tissues differed by approximately 40% after 2 days exposure to the 206Pb tracer. More than 90% of the tracer isotopic signature was contained in the soft tissues after 10 days exposure, while skeletal tissues acquired only approximately 50% of the tracer by the end of the study. Because these animals were maintained under trace metal-clean conditions, they contained lead concentrations in whole blood (0.3-3 ng/g), kidney (11-27 ng/g dry wt), and bone (35-70 ng/g dry wt) tissues that are the lowest known reported for contemporary terrestrial mammals, and they (in bone) are comparable to levels in preindustrial mammals. The elevated concentrations of lead in kidney (fresh weight) relative to levels in blood are consistent with the presence of specific lead-binding sites in the kidney at very low levels of exposure.

Animals↗

Adsorption and isotope effects by ion exchange with 1-aza-12-crown-4 bonded Merrifield peptide resin.

Magnesium isotope effects were investigated by chemical ion exchange with synthesized 1-aza-12-crown-4 bonded Merrifield peptide resin using elution chromatography. The capacity of azacrown ion exchanger was 0.89 meq/g dry resin. The heavier isotopes of magnesium were enriched in the resin phase, while the lighter isotopes were enriched in the solution phase. The hydration effect is less than the complexation and isotope mass effects. The single stage separation factor was determined according to the method of Glueckauf from the elution curve and isotopic assays. The separation factors of 24Mg(2+)-25Mg(2+), 24Mg(2+)-26Mg(2+), and 25Mg(2+)-26Mg(2+) were 1.012, 1.023, and 1.011, respectively.

Chromatography, Ion Exchange↗