Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Galactose biosensors using composite polymers to prevent interferences.

A biosensor using a composite polymer to prevent interferences was used in a flow injection analysis system for the detection of galactose in human plasma. The biosensor consisted of galactose oxidase immobilized on a platinized carbon electrode that had been modified with a composite polymer. The composite polymer showed improved selectivity to hydrogen peroxide compared with either of its individual polymeric components, Nafion and a copolymer of diaminobenzene and resorcinol. The composite polymer minimized the effect of possible interference from urate, ascorbate, and acetaminophen. This analytical system had a minimum detection limit of 50 microM, linearity to 6 mM, a storage stability of greater than 30 days, and a high sample throughput (approx. 120 samples/h).

Biosensing Techniques↗

Fermentation monitoring.

Fermentation monitoring continues to be the focus of much research. Over the last year, important strides were made in improving bioprocess monitoring using NADH fluorescence, viscosity, affinity techniques, enzyme and microbial sensors, calorimetry, flow injection analysis and bioluminescence. Better fermentation monitoring is important for improving understanding, operation, development and control of the process. We expect progress in these areas of research to continue. In addition, we highlight some non-conventional approaches.

Biosensing Techniques↗

Biosensors for fermentation control.

Over the past year, biosensor development has been an active area of research. The actual application of biosensors in process monitoring and control is limited to a few cases, mainly as a result of difficulties relating to their long-range stability and their sensitivity to interfering compounds. Steam sterilization is no longer a problem though, as the great majority of sensors are part of flow-injection analysis systems.

Amino Acids↗

A design for automatic preparation of highly concentrated 188Re-perrhenate solutions.

Rhenium-188 is extremely suitable for the radiotherapy of balloon dilation for the coronary artery restenosis. To satisfy the need of highly concentrated (188)Re-perrhenate for the clinical applications, we designed an apparatus to achieve the purpose of concentrating (188)Re-perrhenate solution. This apparatus comprised of a concentrator, a control box and a computer with an automatic control program. A column of cation-exchange resin in Ag(+) form and an anion-exchange column in series were used in the concentration procedure. More than 90% of (188)Re isotope in the original solution could be collected with 1mL of 0.9% NaCl solution added to collect the (188)Re adsorbed in the column in this final process (90.7+/-2.2%, n=15). We also found that the radiochemical purity in the final solution remained unchanged (100%). The designed process could automatically increase the quality and efficiency of the production of highly concentrated rhenium-188 solution, and could also reduce the radiation dose absorbed by the operator.

Chromatography, Ion Exchange↗

Thermal chip fabrication with arrays of sensors and heaters for micro-scale impingement cooling heat transfer analysis and measurements.

The design and fabrication for a thermal chip with an array of temperature sensors and heaters for study of micro-jet impingement cooling heat transfer process are presented. This thermal chip can minimize the heat loss from the system to the ambient and provide a uniform heat flux along the wall, thus local heat transfer processes along the wall can be measured and obtained. The fabrication procedure presented can reach a chip yield of 100%, and every one of the sensors and heaters on the chip is in good condition. In addition, micro-jet impingement cooling experiments are performed to obtain the micro-scale local heat transfer Nusselt number along the wall. Flow visualization for the micro-impinging jet is also made. The experimental results indicate that both the micro-scale impinging jet flow structure and the heat transfer process along the wall is significantly different from the case of large-scale jet impingement cooling process.

Cold Temperature↗

Frequency bandwidth limitation of external pulse electric field in microchannels. Applications to analyte velocity modulation detections.

Pulse field driven electro-separations have been used for different analytical advantages, such as signal quality improvement and separation performance improvement. We have studied the temporal electro-osmosis in microchannels due to viscous diffusivity under the external pulse electric fields. Theoretical studies derived from Navier-Stokes equations conclude the dependence of the time to steady state electro-osmosis on the channel sizes. Pulse field frequency should be limited by the electro-osmosis setting-in time. We also observed the unstable electro-osmosis as the external field frequency increases. As channel geometry characterization results are employed in the mathematical models, the threshold frequencies obtained in experimental data are consistent with the computational predictions. In previous studies, effective signal quality improvement of electro-separations has been demonstrated, when external pulse fields modulate analyte velocities with synchronous lock-in detection. The results indicate signal-to-noise ratio improvement would be more significant at the high frequency regime where flicker noise is not dominant. Since bandwidth limitation due to fluid viscosity constrains the pulse frequency, optimum analyte velocity modulation is in need of further investigation. Under the bandwidth constrains, we have investigated the theoretical optimum modulation frequencies.

Computer Simulation↗

Simulation of two-dimensional fully developed laminar flow for a magneto-hydrodynamic (MHD) pump.

MHD micro-pumps circumvent the wear and fatigue caused by high pressure-drop across the check valves of mechanical micro-pumps in micro-fluidic systems. Early analyses of the fluid flow for MHD micro-pumps were mostly made possible by the Poiseuille flow theory; however, this conventional laminar approach cannot illustrate the effects of various channel sizes and shapes. This paper, therefore, presents a simplified MHD flow model based upon steady state, incompressible and fully developed laminar flow theory to investigate the characteristics of a MHD pump. Inside the pump, flowing along the channel is the electrically conducting fluid flowing driven by the Lorentz forces in the direction perpendicular to both dc magnetic field and applied electric currents. The Lorentz forces were converted into a hydrostatic pressure gradient in the momentum equations of the MHD channel flow model. The numerical simulations conducted with the explicit finite difference method show that the channel dimensions and the induced Lorentz forces have significant influences on the flow velocity profile. Furthermore, the simulation results agree well with the experimental results published by other researchers.

Computer Simulation↗

Design and fabrication development of a micro flow heated channel with measurements of the inside micro-scale flow and heat transfer process.

The current work provides a design and fabrication technique for a micro channel system that can provide a uniform heat flux boundary condition on the channel wall and a well insulation on the wall to prevent heat loss from the channel to the outside ambient. Therefore, detailed micro-scale flow and heat transfer process and information along the channel can be studied. Semiconductor sensor material was selected to fabricate both the heaters and the arrays of temperature sensors on a silicon substrate. These heaters and sensors were then moved to a low thermal conductivity epoxy-glass substrate for fabrication of the channel. Design consideration and fabrication techniques involved in this processes will be discussed. A final measurement for the validation of the heaters and the sensors fabricated and a study of the flow friction behavior and the heat transfer coefficient distributions inside the micro channel will be presented. The local Nusselt number distrubution inside the micro channel is reported the first time in the open literature.

Equipment Design↗

Organic plasma process for simple and substrate-independent surface modification of polymeric BioMEMS devices.

A polymeric bio micro electromechanical systems (BioMEMS) device was fabricated using organic plasma polymerization, by which the surface of a polymeric substrate could easily be modified through vapor-phase deposition of organic thin films. This technique, capable of polymeric deposition of any kind of monomer, can serve the purpose of anti-fouling coating, wettability control, or layer-to-layer interface creation, on the surface of any given chemically-inert polymeric substrate without involving cumbersome surface organic reactions. A prototype device was fabricated to have an array of electrochemical glucose biosensors with the three electrode configuration, each of which has a microfluidic channel (500 microm x 800 microm) for capillary-action-driven sample delivery and the concerned enzymatic reaction. Stressing the advantages of the plasma polymerization process using a polymeric substrate together with some additional features accomplished in our device fabrication, new possibilities in the field of polymeric BioMEMS are discussed.

Biosensing Techniques↗

Continuous flow immunosensor for highly selective and real-time detection of sub-ppb levels of 2-hydroxybiphenyl by using surface plasmon resonance imaging.

A biosensor based on surface plasmon resonance (SPR) is developed for the detection of 2-hydroxybiphenyl (HBP). A monoclonal antibody against HBP (abbreviated hereafter as HBP-mAb) is developed and used for the detection of HBP by competitive SPR-based immunoassay and enzyme linked immunosorbent assay (ELISA) methods. A novel HBP-hapten compound, HBP-bovine serum albumin conjugate (HBP-BSA), derived by binding several HBP units with BSA by an aliphatic chain spacer is used in the development of antibody and for the functionalization of immunoprobes. HBP-BSA linked to the Au surface of the SPR sensor chip undergoes inhibitive immunoreaction with HBP-mAb in the presence of free HBP. The SPR-based immunoassay provides a rapid determination (response time: approximately 20 min) of the concentration of HBP in the range of 0.1-1000 ppb (ng/ml). Regeneration of the sensor chip is gained by treating the antibody-anchored SPR sensor chip with a pepsin solution (100 ppm (microg/ml); pH 2.0) for few minutes. The SPR sensor chip is reusable for the detection of HBP for more than 20 cycles with average loss of 0.35% reactivity per regeneration step. HBP concentration is determined as low as 0.1 and 3 ppb using the SPR sensor and ELISA measurements, respectively. The developed SPR sensor for HBP is free from interference by coexisting benzo[a]pyrene (BaP), 2,4-dichlorophenoxyacetic acid (2,4-D) and benz[a]anthracene; SPR angle shift obtained to the flow of HBP is almost same irrespective to the presence or absence of a same concentration of these carcinogenic polycyclic aromatic hydrocarbons together. The SPR sensor for HBP is proved to be applicable in simultaneous detection of HBP and BaP in parallel with another SPR sensor for BaP.

Biosensing Techniques↗

Piezoelectric sensor functionalised by a self-assembled bipyridinium derivative: characterisation and preliminary applications in the detection of heavy metal ions.

The synthesis of a molecule, 1-(11-dodecylsulfanyl-undecyl)-[4,4']bipyridinium bromide (1), suitable at the same time to form a covalent bond with gold electrodes of a piezoelectric quartz crystal and to interact with heavy metal ions in aqueous solutions, has been successfully accomplished. A commercial quartz crystal microbalance instrument has been modified in order to perform a Flow-Injection Analysis. The behaviour of the system follows the Kanazawa-Gordon equation as demonstrated by measurements with glucose solutions. The self-assembled layer of 1 onto a gold electrode has been characterised by Atomic Force Microscopy before and after the sensing tests. The sensing performances of the modified gold electrode were investigated by monitoring the frequency variation induced by the presence of heavy metal ions, such as lead, cadmium and mercury, in aqueous media. The explored concentrations ranged between 10(-4) and 10(-2) M and the corresponding frequency variations ranged between 10 and 50 Hz. All responses observed were fast, reproducible and reversible. In particular, the response to mercury appears significantly higher in comparison with the other analytes. To the best of our knowledge, this contribution represents the first example of sensing layer based on bipyridinium receptor showing reversible and, at some extent, differentiated response towards heavy metal ions.

Coated Materials, Biocompatible↗

Cohort analysis of a single nucleotide polymorphism on DNA chips.

A method has been developed to determine SNPs on DNA chips by applying a flow-through bioscanner. As a practical application we demonstrated the fast and simple SNP analysis of 24 genotypes in an array of 96 spots with a single hybridisation and dissociation experiment. The main advantage of this methodical concept is the parallel and fast analysis without any need of enzymatic digestion. Additionally, the DNA chip format used is appropriate for parallel analysis up to 400 spots. The polymorphism in the gene of the human phenol sulfotransferase SULT1A1 was studied as a model SNP. Biotinylated PCR products containing the SNP (The SNP summary web site: ) (mutant) and those containing no mutation (wild-type) were brought onto the chips coated with NeutrAvidin using non-contact spotting. This was followed by an analysis which was carried out in a flow-through biochip scanner while constantly rinsing with buffer. After removing the non-biotinylated strand a fluorescent probe was hybridised, which is complementary to the wild-type sequence. If this probe binds to a mutant sequence, then one single base is not fully matching. Thereby, the mismatched hybrid (mutant) is less stable than the full-matched hybrid (wild-type). The final step after hybridisation on the chip involves rinsing with a buffer to start dissociation of the fluorescent probe from the immobilised DNA strand. The online measurement of the fluorescence intensity by the biochip scanner provides the possibility to follow the kinetics of the hybridisation and dissociation processes. According to the different stability of the full-match and the mismatch, either visual discrimination or kinetic analysis is possible to distinguish SNP-containing sequence from the wild-type sequence.

Arylsulfotransferase↗

A multi-biosensor based on immobilized Photosystem II on screen-printed electrodes for the detection of herbicides in river water.

A multi-biosensor for detection of herbicides and pollutants was constructed using various photosynthetic preparations as biosensing elements. The photosynthetic thylakoid from Spinacia oleracea L., Senecio vulgaris and its mutant resistant to atrazine were immobilized with (BSA-GA) on the surface of screen-printed sensors composed of a graphite-working electrode and Ag/AgCl reference electrode deposited on a polymeric substrate. The biosensor was composed of four flow cells with independent illumination of 650 nm to activate electron transfer in Photosystem II. The principle of the detection was based on the fact that herbicides selectively block electron transport activity in a concentration-dependent manner and that the four PSII biomediators show differential recognition activity toward herbicides. Changes of the activity were registered amperometrically as rate of photoreduction of the artificial electron acceptor DQ. The setup resulted in a reusable herbicide multibiosensor with a good stability (half-life of 16.7 h for spinach thylakoids) and limit of detection of about 10(-8) M for herbicides recovered in spring in river.

Adsorption↗

Continuous-flow/stopped-flow system for enzyme immunoassay using a rotating bioreactor: determination of Chagas disease.

The high sensitivity that can be attained using an immunoassays coupled to a rotating bioreactor with electrochemical detection mediated by [Os(bpy)2Cl(pyCOOH)]Cl, has been verified for the detection of Trypanozoma cruzi (T. cruzi), This protozoan parasite causes Chagas disease, affecting more than 18 million people in central and south America. Antibodies in the serum sample are allowed to react immunologically with whole homogenates of the parasite as antigen that are immobilized on a rotating disk. The bound antibodies are quantified by a horseradish peroxidase (HRP) enzyme labeled second antibodies specific to human IgG in presence of hydrogen peroxide using an osmium complex [Os(bpy)2Cl(pyCOOH)]Cl as enzymatic mediators. The amperometric measurement performed at 0.00 V versus Ag/AgCl can be done within 2 min and the analysis time does not exceed 23 min. The calculated detection limits was 0.01 mIU ml(-1). Reproducibility assays were made using repetitive serum of 0.182 mIU ml(-1) T. cruzi specific antibody (measured as the activity of the correspondent anti-serum's enzyme conjugated); the percentage standard error was less than 5%. The amperometric immunoreactors showed significantly higher sensitivity and lower time consumed than the standard spectrophotometric detection ELISA method.

Animals↗

Detection of pathogenic bacteria in food samples using highly-dispersed carbon particles.

There is an unmet need for detection methods that can rapidly and sensitively detect food borne pathogens. A flow through immunoassay system utilizing highly dispersed carbon particles and an amperometric technique has been developed and optimized. A sandwich immunoassay format was utilized in which pathogenic cells were captured by antibodies immobilized onto activated carbon particles, and labeled with horseradish peroxidase (HRP) conjugated antibodies. Flow of the peroxidase substrates resulted in an amperometric signal that is proportional to the number of captured cells. Factors influencing the analytical performance of the system, such as the quantity of carbon particles and concentrations of capture antibody, enzyme labeled antibody, and enzyme substrates, were investigated and optimized. Detection and quantification of Escherichia coli, Listeria monocytogenes and Campylobacter jejuni were demonstrated with low detection limits of 50, 10, and 50 cells/ml, respectively, and an overall assay time of 30 min. Milk and chicken extract samples were spiked with various concentrations of these pathogens and were used to challenge the system. The system design is flexible enough to allow its application to the detection of viruses and proteins.

Bacteria↗

A multianalyte flow electrochemical cell: application to the simultaneous determination of carbohydrates based on bioelectrocatalytic detection.

A multianalyte flow electrochemical cell (MAFEC) for bioanalysis is constructed, characterised and used for simultaneous carbohydrate analysis incorporating mediated amperometric enzyme electrodes. Although multidetection schemes can be addressed with microfabricated systems, it is demonstrated that a "meso" analytical device of low cost can give answers to traditional simultaneous multianalysis problems, being robust, and easy to construct and operate. The cell operates as a radial flow thin-layer device and can achieve mass transport controlled response for fast electrochemical reactions. When appropriate enzymatic electrodes are used the response becomes kinetically limited, but still shows a better than 5% R.S.D. for response to different sugars analysed. All the enzymatic sensors are mediated with different osmium compounds appropriate for each enzyme's mechanism (NAD or PQQ dehydrogenases) in some cases combining multienzyme sensors. All sensors were optimised so that different sugars do not produce interferences to other sensors. Matrix interferences were kept low by operating all sensors at or below 150 mV versus Ag/AgCl. The integrated system was used for the simultaneous detection of fructose, sucrose, glucose, galactose, and lactose, fully characterising the system for these analytes (sensitivity, dynamic range). Cross referenced calibration curves were used for signal treatment and interpretation and it was possible to analyse real juice and milk samples with results agreeing with the standard enzymatic methods for the same analyses with a sampling frequency of more than 100 h(-1).

Biosensing Techniques↗

Sub-micron particle behaviour and capture at an immuno-sensor surface in an ultrasonic standing wave.

The capture of 200 nm biotinylated latex beads from suspensions of concentration 10(7) to 2.5 x 10(8) particle/ml on an immuno-coated surface of the acoustic reflector in an ultrasound standing wave (USW) resonator has been studied while the acoustic pathlength was less than one half wavelength (lambda/2). The particles were delivered to the reflector's surface by acoustically induced flow. The capture dependencies on suspension concentration, duration of experiments and acoustic pressure have been established at 1.09, 1.46 and 1.75 MHz. Five-fold capture increase has been obtained at 1.75 MHz in comparison to the control (no ultrasound) situation. The contrasting behaviours of 1, 0.5 and 0.2 mum fluorescent latex beads in a lambda/4 USW resonator at 1.46 MHz have been characterized. The particle movements were observed with an epi-fluorescent microscope and the velocities of the particles were measured by particle image velocimetry (PIV). The experiments showed that whereas the trajectories of 1 mum particles were mainly affected by the direct radiation force, 0.5 mum particles were influenced both by the radiation force and acoustic streaming. The 0.2 mum latex beads followed acoustic streaming in the chamber and were not detectably affected by the radiation force. The streaming-associated behaviour of the 200 nm particles has implications for enhanced immunocapture of viruses and macromolecules (both of which are also too small to experience significant acoustic radiation force).

Biosensing Techniques↗

A micro-immuno supported liquid membrane assay (mu-ISLMA).

A chemiluminescent (CL) based micro-immuno supported liquid membrane assay (mu-ISLMA) has been developed that enables clean up, enrichment and detection of simazine in a single miniaturised cartridge system. The mu-ISLM cartridge contains a supported liquid membrane (SLM) sandwiched between a donor and an acceptor plate (channel volumes 1.65 microL), the latter being covered by a thin layer of gold on to which anti-simazine antibodies were covalently immobilised via a self assembled monolayer (SAM) of either dithiobis(11-aminoundecane, hydrochloride) (DTAU) or beta-mercaptoethylamine (beta-MEA). The mu-ISLMA based on DTAU was characterised by both a high apparent extraction efficiency (E(app) = 136%) and high apparent enrichment factor (E(e)(app) = 544), which resulted in a very high sensitivity for simazine (LOD = 0.1 ng L(-1)). The paper discusses the influence of the different SAMs and three different anti-simazine-antibody preparations (polyclonal, affinity purified polyclonal and monoclonal) on the extraction parameters and assay sensitivity. The influence of the sample matrix (e.g. mineral water, orange juice and milk) on the simazine mu-ISLMA was also investigated.

Biosensing Techniques↗