Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “FLUOROSCOPY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Transthoracic fine-needle aspiration guided by fluoroscopy: validity and complications with 19 operators.

During a 3-year period, 19 physicians performed 271 transthoracic fine-needle aspirations (FNA) in 199 patients, using a 23-guage aspiration needle with an 18-guage guiding needle. The diagnosis was confirmed by cytological examination of the needle aspirates in 90 out of 122 patients with malignant tumors, giving a sensitivity of 74%. The specificity of the cytological diagnosis was 100%. Both cytological and histological material was available in 49 patients. The tumor typing from the FNA specimens and the biopsies was in agreement in all but 3 cases. Pneumothorax occurred in 27% of the patients, but only 3.5% required tube drainage. Small variations (p greater than 0.05) in number of diagnostic punctures and rate of complications were evident among the participating physicians and between two fluoroscopic equipments.

Adolescent↗

Cardiac three-dimensional magnetic resonance imaging and fluoroscopy merging: a new approach for electroanatomic mapping to assist catheter ablation.

BACKGROUND: Modern nonfluoroscopic mapping systems construct 3D electroanatomic maps by tracking intracardiac catheters. They require specialized catheters and/or dedicated hardware. We developed a new method for electroanatomic mapping by merging detailed 3D models of the endocardial cavities with fluoroscopic images without the need for specialized hardware. This developmental work focused on the right atrium because of the difficulties in visualizing its anatomic landmarks in 3D with current approaches. METHODS AND RESULTS: Cardiac MRI images were acquired in 39 patients referred for radiofrequency catheter ablation using balanced steady state free-precession sequences. We optimized acquisition and developed software for construction of detailed 3D models, after contouring of endocardial cavities with cross-checking of different imaging planes. 3D models were then merged with biplane fluoroscopic images by methods for image calibration and registration implemented in a custom software application. The feasibility and accuracy of this merging process were determined in heart-cast experiments and electroanatomic mapping in patients. Right atrial dimensions and relevant anatomic landmarks could be identified and measured in all 3D models. Cephalocaudal, posteroanterior, and lateroseptal diameters were, respectively, 65+/-11, 54+/-11, and 57+/-9 mm; posterior isthmus length was 26+/-6 mm; Eustachian valve height was 5+/-5 mm; and coronary sinus ostium height and width were 16+/-3 and 12+/-3 mm, respectively (n=39). The average alignment error was 0.2+/-0.3 mm in heart casts (n=40) and 1.9 to 2.5 mm in patient experiments (n=9), ie, acceptable for clinical use. In 11 patients, reliable catheter positioning and projection of activation times resulted in 3D electroanatomic maps with an unprecedented level of anatomic detail, which assisted ablation. CONCLUSIONS: This new approach allows activation visualization in a highly detailed 3D anatomic environment without the need for a specialized nonfluoroscopic mapping system.

Arrhythmias, Cardiac↗

Volume imaging in fluoroscopy. A clinical prototype system based on a generalized digital tomosynthesis technique.

PURPOSE: This work involves the development of a new digital tomosynthesis technique into a clinical prototype imaging system for the three-dimensional visualization of patient anatomy. MATERIAL AND METHODS: The multiple projection algorithm (MPA) has been developed into a clinical prototype imaging system comprising a digital chain that is interfaced with an isocentric fluoroscopic unit to form an integrated DTS facility. Planes of varying orientations can be synthesized retrospectively on the basis of an acquired set of appropriate projection images extending over the whole volume of interest. RESULTS AND CONCLUSION: The system provides an image reconstruction and processing facility that can effectively augment fluoroscopic examinations. Reconstruction times of a few seconds per plane have been achieved. The region of interest can be approached by tracking through cross-sections with user-selected orientations. Anatomical planes of particular interest can be identified and their reconstructed images can be stored. The characteristics of the image presentation modality have the potential to extend the field of current digital tomosynthesis applications to new areas in radiology and other clinical domains.

Algorithms↗

In vivo articular cartilage contact kinematics of the knee: an investigation using dual-orthogonal fluoroscopy and magnetic resonance image-based computer models.

BACKGROUND: Quantifying the in vivo cartilage contact mechanics of the knee may improve our understanding of the mechanisms of joint degeneration and may therefore improve the surgical repair of the joint after injury. OBJECTIVE: To measure tibiofemoral articular cartilage contact kinematics during in vivo knee flexion. STUDY DESIGN: Descriptive laboratory study. METHODS: Orthogonal fluoroscopic images and magnetic resonance image-based computer models were used to measure the motion of the cartilage contact points during a quasi-static lunge in 5 human subjects. RESULTS: On the tibial plateau, the contact point moved in both the anteroposterior and the mediolateral directions during knee flexion. On the medial tibial plateau, flexion angle did not have a statistically significant effect on the location of the contact points. The total translation of the contact point from full extension to 90 degrees of flexion was less than 1.5 mm in the anteroposterior direction, whereas the translation in the mediolateral direction was more than 5.0 mm. In the anteroposterior direction, the contact points were centered on the medial tibial plateau. On the lateral tibial plateau, there was a statistically significant difference between the location of the contact point at full extension and the locations of the contact points at other flexion angles in the anteroposterior direction. No significant difference was detected between the location of the contact points at other flexion angles. The overall range of contact point motion was about 9.0 mm in the anteroposterior direction and about 4.0 mm in the mediolateral direction. The contact points were primarily on the inner half of the medial and lateral tibial plateaus (the half closest to the tibial spine). The contact points on both femoral condyles were also on the inner half of the condyles (near the condylar notch). CONCLUSIONS: The tibiofemoral contact points move in 3 dimensions during weightbearing knee flexion. The medial tibiofemoral contact points remained within the central portion of the tibial plateau in the anteroposterior direction. Both the medial and lateral tibiofemoral contact points were located on the inner portions of the tibial plateau and femoral condyles (close to the tibial spine), indicating that the tibial spine may play an important role in knee stability. CLINICAL RELEVANCE: The results of this study may provide important insight as to the mechanisms contributing to the development of osteoarthritis after ligament injuries.

Adult↗

A comparison of fluoroscopy and computed tomography-derived volumetric multiple exposure transmission holography for the guidance of lumbar pedicle screw insertion.

Holographic technology has recently been modified in such a manner that it may now provide clinical use. It allows the visualization of complex structures in three dimensions and permits clinician interaction with the image, which, in turn, provides significant additional geometric and anatomic information. To objectively assess the potential clinical applicability of holography in pedicle screw placement, we studied 11 elderly human cadavers. All of the cadavers, each of which showed significant degenerative disease of the lumbar spine, underwent thin-section computed tomographic scans of the lumbar spine. The acquired digital information was processed, and volumetric multiple exposure transmission holographic images were rendered. Pedicle screws were passed into anatomically acceptable and radiographically visualized L3-L5 pedicles in each cadaver, half using fluoroscopic guidance and half using holographic guidance alone. The accuracy of screw placement was objectively assessed by a three-point grading scale. The total score for the placement of each pedicle screw was determined by both trajectory (location within the pedicle) and accuracy (containment within the vertebral body) of screw tip placement parameters. Three points were possible for each screw placed. Screw placement in the last six cadavers was individually timed for each technique, and fluoroscopic time was also recorded. Each technique was used on 27 pedicles. The total score for fluoroscopic screw placement was 71 (71 of a possible 81; 88%) and for holographic screw placement was 74 (74 of a possible 81; 91%). In the last six cadavers, the screw placement time (per cadaver) was 8 minutes for fluoroscopic placement and 3.6 minutes for holographic placement. Fluoroscopic time averaged 1.9 minutes per cadaver.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Robotic-assisted internal fixation of hip fractures: a fluoroscopy-based intraoperative registration technique.

The internal fixation of proximal femoral (hip) fractures is the most frequently performed orthopaedic surgery procedure. When using a sliding compression hip screw, a commonly used fixation device, accurate positioning of the device within the femoral neck-head is achieved by initially drilling a pilot hole. A cannulated component of the hip screw is then inserted over the guide wire (surgical drill bit), which is used to drill the pilot hole. However, in practice, this fluoroscopically controlled drilling process is severely complicated by a depth perception problem and, as such, a surgeon can require several attempts to achieve a satisfactory guide wire placement. A prototype robotic-assisted orthopaedic surgery system has therefore been developed, with a view to achieving accurate right-first-time guide wire insertions. This paper describes the non-invasive digital X-ray photogrammetry-based registration technique which supports the proposed robotic-assisted drilling scenario. Results from preliminary laboratory (in vitro) trials employing this registration technique indicate that the cumulative error associated with the entire X-ray guided robotic system is within acceptable limits for the guide wire insertion process.

Fluoroscopy↗