Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Enzymatic synthesis of heparin related polysaccharides on sensor chips: rapid screening of heparin-protein interactions.

The biological roles of heparin (HP) and heparan sulfate (HS) are mediated mainly through their interaction with proteins. In the present work, we provide a rapid method for screening HP/HS-protein interactions providing structural data on the key sulfo groups that participate in the binding. A library of polysaccharides structurally related to HP was prepared by immobilizing the biotinylated N-sulfated K5 polysaccharide (N-sulfoheparosan) on sensor chips followed by selective modification of this polysaccharide with enzymes that participate in HP/HS biosynthesis. The polysaccharides synthesized on the surface of the sensor chips differ in the number and position of sulfo groups present both on uronic acid and glucosamine residues. Surface plasmon resonance was used to measure the interaction of each member of this polysaccharide library with antithrombin III (ATIII), to afford structural information on sulfo groups required for this HP/HS-protein interaction. This method is viewed as widely applicable for the study of the structure-activity relationship (SAR) of HP/HS-protein interactions.

Antithrombin III↗

Using a micro electroporation chip to determine the optimal physical parameters in the uptake of biomolecules in HeLa cells.

In this study, a new micro electroporation (EP) cell chip with three-dimensional (3D) electrodes was fabricated by means of MEMS technology, and tested on cervical cancer (HeLa) cells. Extensive statistical data of the threshold electric field and pulse duration were determined to construct an EP "phase diagram", which delineates the boundaries for 1) effective EP of five different size molecules and 2) electric cell lysis at the single-cell level. In addition, these boundary curves (i.e., electric field versus pulse duration) were fitted successfully with an exponential function with three constants. We found that, when the molecular size increases, the corresponding electroporation boundary becomes closer to the electric cell lysis boundary. Based on more than 2000 single-cell measurements on five different size molecules, the critical size of molecule was found to be approximately 40 kDa. Comparing to the traditional instrument, MEMS-based micro electroporation chip can greatly shorten the experimental time.

Biopolymers↗

Multi-channel 3-D cell culture device integrated on a silicon chip for anticancer drug sensitivity test.

A novel three-dimensional cell culture system was constructed with an array of cell panels (4 x 5) in a silicon chip, together with multi-channel drug containers. Human breast cancer (MCF-7) cells were embedded in a collagen-gel matrix and entrapped in a pyramidal-shaped silicon hole. Each cell panel can be isolated by a channel composed of a microfluid part and a reservoir. A cell panel was exposed to 200 mm KCN for 2 days to demonstrate that each cell panel could be independently evaluated under various stimulation conditions. Based on the cellular respiration activity, the proliferation behavior was continuously monitored on the silicon-based cell array for 5 days using scanning electrochemical microscopy (SECM). The cells entrapped in the device (3-D culture) proliferated normally, and the proliferation rate was lower than that of cells grown in a monolayer cell culture (2-D culture). The effects of three anticancer drugs measured simultaneously on the cell chip were in good agreement with those obtained by a conventional colorimetric assay. Our results suggest that the silicon-based device for 3D culture is appropriate for a chemosensitivity assay involving multi-chemical stimulation.

Antineoplastic Agents↗

The use of multiple-strain algal sensor chips for the detection and identification of volatile organic compounds.

Although biosensors detecting a great variety of toxicants have been developed during the last decades, the simultaneous detection and identification of several targets by one biosensor is not possible in the majority of the biosensor systems. In our study we proved the concept of the detection and identification of two different volatile toxic compounds with a non-selective biochip-based algal biosensor. For that purpose we produced array plate biochips to utilise three membrane-immobilised algal strains of genus Klebsormidium and Chlorella in one biosensor system. A novel IMAGING-PAM chlorophyll fluorometer was applied to measure the impact of volatile organic compounds (VOC) on photosynthesis of chip-immobilized algae in terms of quantum efficiency of electron transport (DeltaF/F'm). Formaldehyde (FA) vapour was detectable with statistical significance in concentrations relevant to human health from 10 ppb to 10 ppm. The biosensor response recorded within minutes was concentration-dependent and reversible. Moreover, vapours of formaldehyde (0.05-1 ppm) and methanol (MeOH) (200-1000 ppm) were significantly identified by the compound-specific response rate as a quotient of the biosensor responses of the respective algal strains. Using the IMAGING-PAM chlorophyll fluorometer, data sampling proved to be highly efficient. Based on our results we conclude that the principle of the algal sensor chip (ASC) suggests further research on the detection and identification of VOCs and other toxic substances in gaseous environment with that biochip system.

Biosensing Techniques↗

Silicon chip-based patch-clamp electrodes integrated with PDMS microfluidics.

We report on a silicon wafer-based device that can be used for recording macroscopic ion channel protein activities across a diverse group of cell-types. Gigaohm seals were achieved for CHO-K1 and RIN m5F cells, and both cell-attached and whole-cell mode configurations were also demonstrated. Two distinct intrinsic potassium ion channels were recorded in whole-cell mode for HIT-T15 and RAW 264.7 cells. Polydimethylsiloxane (PDMS) microfluidics were also coupled with the micromachined silicon chips in order to demonstrate that a single cell could be selectively directed to a micropore, and membrane protein currents could subsequently be recorded. These silicon chip-based devices have significant advantages over traditional micropipette approaches, and may serve as combinatorial tools for investigating membrane biophysics, pharmaceutical screening, and other bio-sensing tasks.

Animals↗

Identification and characterization of Bacillus anthracis by multiplex PCR on DNA chip.

Bacillus anthracis can be identified by detecting virulence factor genes located on two plasmids, pXO1 and pXO2. Combining multiplex PCR with arrayed anchored primer PCR and biotin-avidin alkaline phosphatase indicator system, we developed a qualitative DNA chip method for characterization of B. anthracis, and simultaneous confirmation of the species identity independent of plasmid contents. The assay amplifies pag gene (in pXO1), cap gene (in pXO2) and Ba813 gene (a B. anthracis specific chromosomal marker), and the results were indicated by an easy-to-read profile based on the color reaction of alkaline phosphatase. About 1 pg of specific DNA fragments on the chip wells could be detected after PCR. With the proposed method, the avirulent (pXO1+/2-, pXO1-/2+ and pXO1-/2-) strains of B. anthracis and distinguished 'anthrax-like' strains from other B. cereus group bacteria were unambiguously identified, while the genera other than Bacillus gave no positive signal.

Alkaline Phosphatase↗

Characterization of a self-assembled monolayer of thiol on a gold surface and the fabrication of a biosensor chip based on surface plasmon resonance for detecting anti-GAD antibody.

A biosensor chip utilizing surface plasmon resonance (SPR) was fabricated for detecting anti-glutamic acid decarboxylase (GAD) antibody, which is an indicator of the presence of type I diabetes mellitus. The sensor surfaces were constructed from various thiol mixtures of different molar ratios of 3-mercaptopropionic acid (3-MPA) to 11-mercaptoundecanoic acid (11-MUA). To determine the surface characteristics of the different alkanethiol monolayers, several quantitative and kinetic measurements were carried out. The extent of immobilization of streptavidin (SA) and biotin-GAD (the anti-GAD receptor) and the immune response of anti-GAD antibody against GAD were measured using the SPR biosensor. The terminal functional group of a thiol has different effects on the adsorption and covalent binding of protein depending on the steric hindrance. The protein chip described herein permits simple, rapid detection of anti-GAD antibody.

Antibodies↗

On-chip micro-biosensor for the detection of human CD4(+) cells based on AC impedance and optical analysis.

The current study was undertaken to fabricate a small micro-electrode on-chip to rapidly detect and quantify human CD4(+) cells in a minimal volume of blood through impedance measurements made with simple electronics that could be battery operated implemented in a hand held device. The micro-electrode surface was non-covalently modified sequentially by incubation with solutions of protein G', human albumin, monoclonal mouse anti-human CD4, and mouse IgG. The anti-human CD4 antibody served as the recognition and capture molecule for CD4(+) cells present in human blood. The binding of these biomolecules to the micro-electrodes was verified by impedance and cyclic voltammetry measurements. An increase in impedance was detected for each layer of protein adsorbed onto the micro-electrode surface. This process was shown to be highly repeatable. Increased impedance was measured when CD4(+) cells were captured on the micro-electrode, and the impedance also increased as the number of captured cells increased. Fluorescence microscopy of captured cells immunolabeled with anti-human CD4, CD8, and CD19 antibodies, and the nuclear label DAPI, confirmed that only CD4(+) cells were captured. The results were highly dependent on the specimen preparation method used. We conclude that the on-chip capture system can efficiently quantify the number of CD4(+) cells.

Biosensing Techniques↗

Manipulation and extraction of genomic DNA from cell lysate by functionalized magnetic particles for lab on a chip applications.

A novel approach for extracting living cells' genomic DNA materials utilizing functionalized magnetic particles (MPs) is reported in this investigation. This strategy is amenable to handle bio-samples in a miniaturized environment and it offers a possibility to separate and purify DNA from other cell lysate mixtures "on-chip", which is known to be a bottle-neck step in an integrated micro-total-analysis-system (muTAS). "Species-specific" genomic DNA of interest is captured by the MPs based on the hybridization interaction between the biotinylated probes modified MPs and a complementary region of the targeted genome. The genome DNA anchored on the particles can be separated from the rest of cellular mixtures by a simple buffer washing upon the exertion of external magnetic force. Surface modifications of MPs and hybridization conditions affecting the genome capturing efficiency are investigated. Extraction of genomic DNA from E. coli is demonstrated in a silicon/glass-based micro-reactor patterned with a platinum heater and sensors. On-chip extraction and manipulation of genomic DNAs illustrated in this study is a step forward toward a total integrated bioanalytical microsystem for crude cells/sample analysis.

Biosensing Techniques↗

Measurement of electrical activity of long-term mammalian neuronal networks on semiconductor neurosensor chips and comparison with conventional microelectrode arrays.

Based on complementary metal-oxide semiconductor (CMOS) technology a neurosensor chip with passive palladium electrodes was developed. The CMOS technology allows a high reproducibility of the sensors as well as miniaturization and the on-chip integration of electronics. Networks of primary neurones were taken from murine foetal spinal cord (day 14) and frontal cortex (day 15) tissues and cultured on the silicon surface in a chamber volume of 200 microl with 7 mm diameter. Measurements were performed between days 15 and 59 in vitro. Signals were recorded from both types of cultures. To test the capability of the system to detect pharmacologically induced activity changes two established neuromodulators were applied. The GABA(A)-receptor blocker bicuculline was applied to both tissue cultures, the glycine-receptor blocker strychnine to spinal cord cultures. Four network frequency parameters were analysed: spike rate (SR), burst rate (BR), frequency in bursts (FiB) and peak frequency in bursts (PFiB). Significant changes of spike rate and burst rate were measured with spinal cord cultures after bicuculline application. Significant changes of frequency in bursts and peak frequency in bursts were observed with frontal cortex cultures after bicuculline application. Significant changes of spike rate and frequency in bursts were recorded with spinal cord cultures after strychnine application. These results were compared with results achieved in the same laboratory by using glass-microelectrode arrays (MEAs). This comparison showed for spinal cord similar native spike and burst rate, but higher mean frequency and peak frequency in bursts, whereas frontal cortex activity had higher spike and burst rate and peak frequency in bursts. Application of bicuculline or strychnine to spinal cord networks showed stronger effects on MEAs, whereas with frontal cortex networks the modulation of activity was similar after application of bicuculline.

Action Potentials↗

Cytometry on a chip: cellular phenotypic and functional analysis using grating-coupled surface plasmon resonance.

Grating-coupled surface plasmon resonance imaging (GCSPRI) is a method for the accurate assessment of both cell phenotype and function. In GCSPRI, cells and/or proteins of interest are flowed across antibodies immobilized on a gold-coated sensor chip. The surface of the chip is illuminated with monochromatic light that couples with surface plasmons in the gold. At a specific angle of incidence, the GCSPR angle, the maximum amount of coupling occurs. Shifts in the GCSPR angle can be correlated with refractive index changes following cell or analyte capture by the immobilized antibodies. In addition, GCSPRI can image the cells as they are being captured. GCSPRI's multiplexed format allows for the parallel assessment of up to 400 individual antibody regions. In this paper, we demonstrate GCSPRI's ability to identify cells and proteins of interest and compare results to a traditional flow cytometry system. This technology represents a fast and powerful method for the simultaneous assessment of cell phenotype and function.

Animals↗

Poly(dimethyl siloxane)-based protein chip for simultaneous detection of multiple samples: use of glycidyl methacrylate photopolymer for site-specific protein immobilization.

This paper describes fabrication of a poly(dimethyl siloxane) (PDMS)-based chip to analyze multiple protein interactions utilizing glycidyl methacrylate (GMA) photopolymer for a site-specific immobilization of capture proteins in a closed system. First, using one direction channels of a PDMS mold having cross-channels, GMA micropads were prepared by photopolymerizing GMA solution by 365 nm light irradiation at predetermined positions. After the first mold was replaced with a second mold having higher height or directly without mold changing, capture proteins were allowed to be covalently immobilized onto the surface of the epoxide-activated GMA pads. Following immobilization, poly(ethylene glycol) diacrylate (PEG-DA) precursor was photopolymerized at specific regions to generate plugs for prevention of mixing between different sample injection channels, diminishing the need of a mold changing for sample injections. Final chip was assembled by connecting separated sample injection channels using a connector mold. The viability of this strategy was successfully demonstrated by simultaneous detection of two different antigen-antibody interactions.

Biocompatible Materials↗

Electrophysiological recordings of single ion channels in planar lipid bilayers using a polymethyl methacrylate microfluidic chip.

Planar lipid bilayers are used for functional studies of ion channel proteins using electrophysiological techniques. We have been developing a plastic micro-fluidic device for the reconstitution of planar lipid bilayers and electrophysiological recordings toward a "membrane protein chip" for high-throughput screening. In the previous report [Suzuki, H., Tabata, K.V., Noji, H., Takeuchi, S., 2006. Highly reproducible method of planar lipid bilayer reconstitution in polymethyl methacrylate microfluidic chip. Langmuir 22 (4), 1937-1942], we presented the method and device in which the reproducibility of planar lipid bilayers reached 90%, and multiple bilayers were formed simultaneously. In this communication, we show that our device has excellent electric properties suitable for ion channel analysis down to single molecular level. Additional aspects on the optical accessibility and controllability on lipid bilayer formation are also presented.

Electrochemistry↗

Automated 10-channel capillary chip immunodetector for biological agents detection.

The automated 10-channel capillary chip immunodetector (10K-IDWG) is a prototype, which has been developed for automatically operated biological agents (BA) point detection. The current technology uses a chemiluminescence capillary immunoassay (EIA) technique in combination with integrated microfluidics and allows the highly sensitive and rapid detection and preliminary identification of multiple BA in aqueous solutions in the laboratory. The chemiluminescence capillary EIA are performed within a disposable capillary chip containing 10 fused-silica capillaries arranged in parallel coated with selected capture antibodies. A multianode-photomultiplier array is used to detect chemiluminescence intensity in each capillary. Reservoirs for reagents and buffers and a waste disposal reservoir are integrated. This paper describes the technology of the 10K-IDWG and its evaluation with three different BA, the toxin staphylococcal enterotoxin B (SEB), the bacterial analyte Escherichia coli (E. coli) O157:H7 as a model for bacterial pathogens, and the bacteriophage M13 as a model for virus pathogens. The 10K-IDWG is able to detect the above mentioned three BA in an aqueous sample within 29 min (single analyte-detection and multiplexing). Limits of detection (LOD) are 0.1 ng/ml for SEB, 10(4)cfu/ml for E. coli O157:H7, and 5x10(5) pfu/ml for M13. Cross reactivities between the three assays were not observed.

Biosensing Techniques↗

Electrochemical detection of 17beta-estradiol using DNA aptamer immobilized gold electrode chip.

An electrochemical detection method for chemical sensing has been developed using a DNA aptamer immobilized gold electrode chip. DNA aptamers specifically binding to 17beta-estradiol were selected by the SELEX (Systematic Evolution of Ligands by EXponential enrichment) process from a random ssDNA library, composed of approximately 7.2 x 10(14) DNA molecules. Gold electrode chips were employed to evaluate the electrochemical signals generated from interactions between the aptamers and the target molecules. The DNA aptamer immobilization on the gold electrode was based on the avidin-biotin interaction. The cyclic voltametry (CV) and square wave voltametry (SWV) values were measured to evaluate the chemical binding to aptamer. When 17beta-estradiol interacted with the DNA aptamer, the current decreased due to the interference of bound 17beta-estradiol with the electron flow produced by a redox reaction between ferrocyanide and ferricyanide. In the negative control experiments, the current decreased only mildly due to the presence of other chemicals.

Aptamers, Nucleotide↗

A PNA-DNA hybridization chip approach for the detection of beta-secretase activity.

Developed was the addressable chip technology based on the PNA-DNA complementary hybridization equipped with short seven-mer PNA-encoded peptides that can be a versatile scaffold to monitor on-chip immunoassays. We also developed and validated a methodology to perform beta-secretase enzyme assay with a highly sensitive fashion, resulting that a peptide substrate tethering dual fluorescent probes allowed us to detect beta-secretase activity 10 times more sensitively than assays in solution.

Amyloid Precursor Protein Secretases↗

Modeling of electrodialytic and dialytic removal of Cr, Cu and As from CCA-treated wood chips.

A one-dimensional model is developed for simulating the electrodialytic and dialytic treatment of a saturated bed of wood chips containing chromium, copper and arsenic. The movement of Cr, Cu and As is mathematically modeled taking into account the diffusion transport resulting from the concentration gradients of their compounds and the electromigration of their ionic, simple and complex species during the operation. The model also includes the electromigration of the non-contaminant principal ionic species in the system, H(+) and OH(-), proceeding from the electrolysis at the electrodes, Na(+) and NO(3)(-) used as electrolyte solutions in the electrode compartments, and oxalate ions and protons incorporated with the oxalic acid solution during wood chips incubation. The model simulation also takes into account that OH(-) generated on the cathode, during electrodialytic remediation, is periodically neutralized by addition of nitric acid in the cathode compartment. The anion and cation-exchange membranes are simply represented as ionic filters that preclude the transport of co-ions (the cations and anions respectively) with the exception of H(+), which is retarded but considered to pass through the anion-exchange membrane.

Arsenates↗

On-chip electrochromatography using sol-gel immobilized stationary phase with UV absorbance detection.

A chromatography column on a chip was fabricated by immobilizing reversed-phase stationary phase particles (5 microm, C4) using sol-gel technology. Channels were fabricated in quartz using photolithography and wet etching. Localization of the stationary phase was achieved by immobilizing the stationary phase at the desired location in the separation channel prior to bonding of the cover plate. Cross channel design was employed for gated injection. An optical fiber setup was developed for carrying out on-chip UV absorbance detection. The effective optical path length was theoretically determined for the trapezoidal shaped channel and the result was shown to match closely with the experimentally determined value. The effect of applied voltage on velocity was evaluated using thiourea as an unretained marker. Separation performance of the stationary phase was demonstrated by separation of three peptides (Trp-Ala, Leu-Trp and Trp-Trp) under isocratic chromatographic conditions.

Chromatography, Micellar Electrokinetic Capillary↗