Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Angiography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47Linked to original sources

Clinical and experimental investigation of pseudoaneurysm in the anterior communicating artery area on 3-dimensional time-of-flight cerebral magnetic resonance angiography.

OBJECTIVE: To investigate the hemodynamic mechanism of pseudoaneurysm in the anterior communicating artery (AcoA) area in magnetic resonance (MR) angiography. METHODS: For the clinical study, a total of 62 patients who undertook digital subtraction angiography (DSA) because of the rupture of an aneurysm originating from a location other than the AcoA area were examined with MR angiography. The relation between signal defect at the AcoA in MR angiography and anatomic variation of the anterior cerebral artery (ACA) was evaluated. For the experimental study, MR angiography and DSA were performed on elastic silicon vascular phantoms with 2 different bifurcation angles (70 degrees and 140 degrees). Hemodynamic factors producing signal defects were evaluated, and the results were compared by computational fluid dynamics (CFD). RESULTS: In a clinical study, 21 of 62 patients had a hypogenetic A1 segment on either side of the ACA. Their MR angiography showed signal defects in the axilla area of the bifurcated AcoA complex in 14 patients, 7 of which could make the residual normal vessel seem to be an aneurysm. All the cases with an intact AcoA complex showed no signal defect. In an experimental study, MR angiography of vascular phantoms with broad-angle bifurcation (140 degrees) showed signal defects at the axilla areas of bifurcation, and these were shown as turbulent flow in DSA and CFD. Phantoms with narrow-angle bifurcation (70 degrees) did not show a significant signal defect, however. CONCLUSIONS: A hypoplastic A1 segment accompanying a broad bifurcation angle of the contralateral A1 segment may cause a pseudoaneurysm in MR angiography because of signal defect in the AcoA area.

Adolescent↗

Angiography for acute lower gastrointestinal hemorrhage: efficacy of cut film compared with digital subtraction techniques.

PURPOSE: To find out if digital subtraction angiography (DSA) has a different diagnostic power than conventional cut-film angiography in investigating acute lower gastrointestinal (GI) hemorrhage. MATERIALS AND METHODS: Retrospective analysis of two cohorts of patients investigated by angiography for acute lower GI hemorrhage was performed. One group of patients treated at one center ("hospital H") underwent conventional angiography. The other patients, treated at another center ("hospital G"), were investigated exclusively by DSA. The groups were compared for demographic characteristics, etiology, and bleeding parameters. The diagnostic power of both angiographic modalities was compared and statistically analyzed. RESULTS: Fifty-five lower GI hemorrhages investigated by conventional cut-film angiography and 53 cases studied by DSA were included. Both study groups had statistically similar demographic and bleeding characteristics. Overall sensitivity, specificity, and positive and negative predictive values of cut-film angiography for localizing the lower GI bleeding were 62%, 73%, 86%, and 42%, whereas, for DSA, the respective values were 60%, 100%, 100%, and 24% (Z-test P values were.78,.02,.03, and.16). CONCLUSIONS: DSA is as sensitive as conventional cut-film angiography for localizing acute lower GI bleeding. If a lesion is found, the chance that it will be the bleeding source is higher with DSA than with conventional angiography.

Acute Disease↗

Helical high-resolution volume-rendered 3-dimensional computer tomography angiography in the detection of intracranial aneurysms.

BACKGROUND AND PURPOSE: This study was carried out to determine whether high-resolution 3-dimensional prospective-volume-rendered computed tomographic (CT) angiography can replace conventional intra-arterial digital subtractional angiography in the diagnostic evaluation of patients with an acute subarachnoid hemorrhage (SAH) due to ruptured intracranial aneurysm. METHODS: Both techniques were performed in 30 consecutive patients within 2 to 12 hours after their admission to the hospital. RESULTS: In this group of 30 patients, CT angiography with 3-dimensional volume-rendered reconstruction detected 31 aneurysms in 25 patients. Two aneurysms were missed on CT angiography. Conventional angiography detected 33 aneurysms in 27 patients. The authors considered angiograms in 3 patients presenting with SAH as normal. In all cases where an aneurysm was detected on CT angiography, the finding was confirmed by conventional angiography. CONCLUSIONS: CT angiography with 3-dimensional post-processing is a sensitive, noninvasive method that provides a 3-dimensional view of intracranial vessels and the aneurysm. It is also very useful in planning either surgical or endovascular treatment.

Acute Disease↗

Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels.

PURPOSE: To compare the diagnostic accuracy of time-resolved three-dimensional contrast material-enhanced magnetic resonance (MR) angiography with that of conventional angiography for imaging the lower extremity vasculature. MATERIALS AND METHODS: Sixty-nine patients who were evaluated for possible surgical intervention underwent conventional angiography (ie, digital subtraction angiography [DSA]) and contrast-enhanced MR angiography (ie, time-resolved imaging of contrast kinetics [TRICKS]). Two independent, blinded readers evaluated vessel stenosis and occlusion at DSA and MR angiographic image readings. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve were analyzed with repeated-measures analysis of variance. The Cohen kappa test was performed to examine interreader variability. RESULTS: At pooled readings, contrast-enhanced MR angiography had a sensitivity of 78% and a specificity of 98% for detection of occlusion. For detection of significant stenosis (at least one > or = 50% stenosis), sensitivity and specificity were 77% and 91%, respectively. Interreader agreement was high for detection of both occlusion (kappa = 0.76) and significant stenosis (kappa = 0.68). Sensitivity increased as MR angiographic technical parameters were optimized. When improvements resulting from coil type and injection protocol were considered, the sensitivity and specificity of TRICKS MR angiography were 89% and 97%, respectively, for occlusion detection and 87% and 90%, respectively, for significant stenosis detection. CONCLUSION: Contrast-enhanced TRICKS MR angiography is a feasible and minimally invasive means of acquiring angiograms of the peripheral vasculature with high sensitivity and specificity.

Adult↗

MR angiography of aortoiliac occlusive disease: a phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325.

PURPOSE: To evaluate prospectively the safety and effectiveness of aortoiliac magnetic resonance (MR) angiography enhanced with MS-325 (gadofosveset trisodium) at a dose of 0.03 mmol/kg; effectiveness was defined as accuracy relative to the reference standard, conventional angiography. MATERIALS AND METHODS: Study was approved by institutional review boards of participating institutions, and required national approvals were obtained. Study protocol conformed to Good Clinical Practice guidelines, and informed patient consent was obtained. Patients with known or suspected peripheral vascular disease received 0.03 mmol/kg MS-325 for aortoiliac MR angiography. They were also examined with conventional angiography. MS-325-enhanced MR was evaluated for safety and effectiveness. Along with unenhanced two-dimensional time-of-flight MR angiography, it was compared with conventional angiography for presence of vascular stenosis. Student t tests were used to identify significant improvement in diagnostic sensitivity, specificity, and accuracy, as well as quantitative characterization of stenoses by three blinded readers. Correlations between readers of conventional angiograms were calculated and compared with MR results. RESULTS: In 174 patients, MS-325-enhanced MR angiography showed significant improvement (P < or = .001) in sensitivity, specificity, and accuracy for diagnosis of clinically significant (> or =50%) stenosis, compared with unenhanced MR. For all readers, areas under the receiver operating characteristic curve for both quantitative and qualitative measures of significant disease increased (P < .001) for MS-325-enhanced MR compared with time-of-flight MR. All readers also expressed higher confidence in diagnosis (P < .001) and found fewer images uninterpretable with MS-325 enhancement. All measures of interpretation accuracy approached corresponding measures of correlation between readers of conventional angiograms. Incidence of severe and serious adverse events with MS-325 was low. No patients were withdrawn from study due to adverse events or abnormalities in laboratory results. There were no clinically important trends in findings at hematology, blood chemistry, urinalysis, electrocardiography, or physical examination. CONCLUSION: MR angiography with MS-325 provides significant improvement in effectiveness over unenhanced MR (and minimal and transient side effects) at a dose of 0.03 mmol/kg and was safe and effective for MR evaluation of patients with aortoiliac occlusive disease.

Adult↗

Iliofemoral arterial occlusive disease: contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement.

PURPOSE: To evaluate the efficacy of contrast material-enhanced magnetic resonance (MR) angiography for the diagnosis of peripheral arterial occlusion and follow-up after stent placement. MATERIALS AND METHODS: Sixty-seven patients (21 women, 46 men; mean age, 64.6 years) were examined. Digital subtraction angiography and contrast-enhanced MR angiography were performed in 28 patients for preinterventional evaluation of iliofemoral arterial occlusion and in 39 patients for follow-up after stent placement in the iliac or femoral arteries, which had been performed several months before. RESULTS: All 24 occlusions were correctly diagnosed with contrast-enhanced MR angiography. Of the 59 stenoses, 36 were greater than 50% and 23 were 50% or less. Sensitivity and specificity for the detection of stenoses greater than 50% were 100% and 83%, respectively. Patency of the different stents was determined correctly with contrast-enhanced MR angiography. Some stents caused signal intensity dropout, which made MR evaluation of stents difficult. Generally, these signal intensity artifacts were most severe in stainless steel stents and mild in some nitinol stents. CONCLUSION: Contrast-enhanced MR angiography is comparable to digital subtraction angiography for the detection of stenosis greater than 50% and occlusion in the iliofemoral arteries. Stent patency can be determined, but contrast-enhanced MR angiography is not suitable for stent evaluation owing to signal intensity dropout; however, it provides information about the vascular anatomic areas proximal and distal to the stent.

Angiography, Digital Subtraction↗

MR coronary angiography with breath-hold targeted volumes: preliminary clinical results.

PURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS: Thirty-eight patients referred for elective coronary angiography were included. The coronary arteries were localized during single-breath-hold, three-dimensional imaging of the entire heart. MR coronary angiography was then performed along the major coronary branches with a double-oblique, three-dimensional, gradient-echo sequence. Conventional coronary angiography was the reference-standard method. RESULTS: Adequate visualization was achieved with MR coronary angiography in 85%-91% of the proximal coronary arterial branches and in 38%-76% of the middle and distal branches. Overall, 187 (69%) of 272 segments were suitable for comparison between conventional and MR coronary angiography. The diagnostic accuracy of MR coronary angiography for the detection of hemodynamically significant stenoses was 92%; sensitivity, 68%; and specificity, 97%. The sensitivity in individual segments was 50%-77%, whereas the specificity was 94%-100%. CONCLUSION: Adequate visualization of the major coronary arterial branches was possible in the majority of patients. The observed accuracy of MR coronary angiography for detection of hemodynamically significant coronary arterial stenosis is promising, but it needs to be higher before this modality can be used reliably in a clinical setting.

Adult↗

Safety and effectiveness of single- versus triple-dose gadodiamide injection- enhanced MR angiography of the abdomen: a phase III double-blind multicenter study.

PURPOSE: To evaluate the safety and effectiveness of gadodiamide-enhanced magnetic resonance (MR) angiography with single and triple doses in the assessment of abdominal arterial stenoses. MATERIALS AND METHODS: One hundred five patients were included in the randomized, double-blind, phase III multicenter trial. Results of MR angiography with 0.1 mmol/kg and 0.3 mmol/kg doses of gadodiamide were compared with those of digital subtraction angiography (DSA) and according to dose. RESULTS: No serious adverse events were observed. The mean contrast index at the region proximal to the primary stenosis was significantly higher in the triple-dose group (P =.03). Mean 95% CI values for the difference in depicted degree of stenosis between DSA and postcontrast MR angiography improved from -3.4% +/- 4.7 (SD) in the single-dose group to -1.2% +/- 4.7 in the triple-dose group. Mean values for overall image quality on the visual analogue scale improved with the triple dose (P =.02). Confidence in diagnosis was high at postcontrast MR angiography in 88% and 96% of cases in the single- and triple-dose groups, respectively. CONCLUSION: Gadodiamide-enhanced MR angiography performed with single and triple doses is safe and effective for assessing major abdominal arterial stenoses. Although high agreement between MR angiography and DSA was achieved with both doses, triple-dose MR angiography was superior in the evaluations of image quality, degree of arterial stenoses, and confidence in diagnosis.

Abdomen↗

Hypofluorescent spots on indocyanine green angiography at the recovery stage in multiple evanescent white dot syndrome.

PURPOSE: To evaluate the fundus lesions in a young woman. METHODS: Visual function, ophthalmoscopy, electrophysiology, fluorescein angiography, and indocyanine green angiography were performed. RESULTS: A 24-year-old woman had decreased visual acuity (0.2), granularity in the macula, and multiple yellow-white patches in the fundus, reduced a wave on electroretinography, hyperfluorescence on fluorescein angiography, and hypofluorescence on indocyanine green angiography in the left eye. When visual acuity improved to 1.0, the white dots disappeared ophthalmoscopically, and fluorescein angiography showed normal findings. Hypofluorescent spots were found, however, on indocyanine green angiography. CONCLUSION: It is possible that signs of multiple evanescent white dot syndrome may remain longer during examination by indocyanine green angiography than by visual function, ophthalmoscopy, or fluorescein angiography.

Adult↗

Clinical evaluation of indocyanine green video-angiography in the diagnosis of choroidal neovascular membrane associated with age-related macular degeneration.

The Authors compared ICG video-angiographic findings in 85 eyes of 78 cases of presumed choroidal neovascular membrane (CNM) associated with age-related macular degeneration with those diagnosed by fluorescein angiography. The detection rate of CNM was 68% with indocyanine green (ICG) video-angiography and 59% with fluorescein angiography. ICG video-angiography can be especially useful for identifying hemorrhagic or exudative detachments of the retinal pigment epithelium. In these cases, detection of CNM by ICG video-angiography was generally far superior to that by fluorescein angiography. However, some CNM in which leakage was identified with fluorescein angiography could not be visualized by ICG video-angiography.

Aged↗

Detection of main renal artery stenosis using phase-contrast cine MR angiography.

OBJECTIVE: The purpose of our study was to assess the ability of phase-contrast cine MR angiography to detect the presence of main renal artery stenosis. SUBJECTS AND METHODS: We prospectively evaluated 75 hypertensive patients form main renal artery stenosis using phase-contrast cine MR angiography. Each main renal artery was evaluated as normal or abnormal. Thirty-seven of the 75 patients underwent conventional arteriography or intraarterial digital subtraction arteriography; these results were compared with the MR angiographic interpretations. Only those patients who had confirmatory arteriography were included in the statistical analysis. RESULTS: Thirty-six main renal arteries interpreted as normal by MR angiography were found to be without a focal stenosis on invasive arteriography. MR angiography suggested 32 main renal artery stenoses; invasive arteriography showed 29 of these as stenoses. Three main renal arteries that were interpreted as having focal stenoses by MR angiography were shown to be not stenotic by invasive arteriography. Three other patients had diffusely narrowed main renal arteries bilaterally without a focal stenosis on MR angiography; bilateral proximal renal artery stenoses were seen at arteriography in two of these patients, and diffusely narrowed main renal arteries were seen in the third patient. Thus, the sensitivity of phase-contrast cine MR angiography for detecting a focal stenosis or abnormal main renal artery was 100% (95% confidence interval, 88-100%) and the specificity was 93% (95% confidence interval, 80-99%). The kappa coefficient was 0.85 with a standard error of 0.08. CONCLUSION: Phase-contrast cine MR angiography had a high degree of accuracy and a high negative predictive value in detecting the presence of main renal artery stenoses and may be a good screening technique for renovascular hypertension.

Adult↗

MR angiography of tibial runoff vessels: imaging with the head coil compared with conventional arteriography.

OBJECTIVE: We compared peripheral vascular MR angiography done with a standard transmit-receive head coil with conventional arteriography for identifying and evaluating runoff vessels below the knee. MATERIALS AND METHODS: We examined 55 legs in 31 symptomatic patients with both conventional contrast angiography and gradient-echo two-dimensional time-of-flight MR angiography. Both legs of patients were placed in a standard transmit-receive head coil for MR angiography and were imaged simultaneously. For evaluation of stenoses, images of vessels were divided into 10 segments, and each segment was graded on a four-point scale. RESULTS: In the 393 native vascular segments evaluated, the sensitivity of MR angiography in identifying normal vessels was 95% and the specificity was 98%. In detecting segmental occlusion, MR angiography was 98% sensitive and 97% specific. Sensitivity and specificity for stenoses greater than 75% were 98% and 96%, respectively, and for stenoses greater than 50%, they were 98% and 95%, respectively. Interpretative discrepancies were found in 35 vessel segments in 18 legs; none was of clinical relevance. Of all vessel segments shown as occluded by conventional angiography, 1% appeared patent on MR angiograms. No vessel segments shown as normal on MR angiograms were found to be occluded on conventional angiograms. CONCLUSION: When performed simultaneously on both legs of symptomatic patients, 2D time-of-flight MR angiography with a standard transmit-receive head coil provides a time-efficient and highly sensitive and specific means of evaluating below-knee runoff.

Adult↗

Using gadolinium-enhanced three-dimensional MR angiography to assess arterial inflow stenosis after kidney transplantation.

OBJECTIVE: Our objective was to evaluate use of gadolinium-enhanced three-dimensional (3D) MR angiography in the assessment of suspected arterial inflow stenosis after kidney transplantation. SUBJECTS AND METHODS: Twenty-eight consecutive patients receiving kidney transplants (26 single-kidney transplants and two en block transplants) with suspected arterial inflow stenosis were examined with two MR angiography sequences: gadolinium-enhanced 3D fast spoiled gradient-recalled (SPGR) imaging and 3D phase-contrast imaging. Twenty-four of these patients then were examined using the gold standards: either digital subtraction angiography (DSA) (n = 23) or surgery (n = 1). MR angiography and DSA studies were independently and prospectively analyzed for the presence of arterial stenoses (mild [<50%], severe [50-90%], or critical [>90%]) in the iliac, anastomotic, and renal artery segments. Two independent observers retrospectively evaluated the MR angiography sequences for ability to detect or exclude significant (> or = 50%) arterial stenoses. RESULTS: In 22 single-kidney transplants, DSA showed eight significant stenoses in 66 arterial segments. MR angiograms adequately showed 66 of 66 segments (prospective observers) and 64 of 66 segments (each retrospective observer), which were subsequently evaluated. The sensitivity and specificity of MR angiography in revealing significant stenoses were 100% and 98% (prospective analysis), 88% and 98% (retrospective observer 1), and 86% and 100% (retrospective observer 2). Concordance between observers showed kappa values exceeding .85 for all comparisons except the analysis of phase-contrast series (kappa = .62). In one en block transplant, DSA showed that stenosis was greater than 90%, although it had been graded at less than 50% with MR angiography. CONCLUSION: Gadolinium-enhanced 3D MR angiography accurately evaluated arterial inflow in single-kidney transplants.

Angiography, Digital Subtraction↗

Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease.

OBJECTIVE: We assessed the diagnostic performance of whole-body 3D contrast-enhanced MR angiography in comparison with digital subtraction angiography (DSA) of the lower extremities in patients with peripheral arterial occlusive disease. SUBJECTS AND METHODS. Fifty-one patients with clinically documented peripheral arterial occlusive disease referred for DSA of the lower extremity arterial system underwent whole-body MR angiography on a 1.5-T MR scanner. Paramagnetic gadobutrol was administered and five contiguous stations were acquired with 3D T1-weighted gradient-echo sequences in a total scanning time of 72 sec. DSA was available as a reference standard for the peripheral vasculature in all patients. Separate blinded data analyses were performed by two radiologists. Additional vascular disease detected by whole-body MR angiography was subsequently assessed on sonography, dedicated MR angiography, or both. RESULTS: All whole-body MR angiography examinations were feasible and well tolerated. AngioSURF-based whole-body MR angiography had overall sensitivities of 92.3% and 93.1% (both 95% confidence intervals [CIs], 78-100%) with specificities of 89.2% and 87.6% (both CIs, 84-98%) and excellent interobserver agreement (kappa = 0.82) for the detection of high-grade stenoses. Additional vascular disease was detected in 12 patients (23%). CONCLUSION: Whole-body MR angiography permits a rapid, noninvasive, and accurate evaluation of the lower peripheral arterial system in patients with peripheral arterial occlusive disease, and it may allow identification of additional relevant vascular disease that was previously undetected.

Adult↗

Clinical significance of the flow gap in carotid magnetic resonance angiography.

Magnetic resonance (MR) angiography offers a safe, noninvasive alternative to conventional angiography in patients with suspected carotid stenosis; however, it tends to overestimate the severity of stenosis. Loss of the MR signal with a resulting flow gap is a frequent finding in cases of high-grade stenosis. The authors undertook this study to define the range of carotid stenosis associated with a flow gap on two-dimensional time-of-flight (2DTF)-MR angiography. Blinded evaluations were made of 102 common carotid bifurcations in 51 patients who had undergone both conventional angiography and 2DTF-MR angiography. The percent of diameter stenosis was calculated from the conventional angiogram using the method adopted by the Asymptomatic Carotid Atherosclerosis Study (ACAS) trial. An MR flow gap was noted if there was a segment of the vessel that was completely free of signal with a reappearance of the signal distally. According to conventional angiography, the minimum percentage of stenosis associated with a flow gap is 56%. Flow gaps were present in 20 of 22 arteries (sensitivity 91%) with stenosis of 60% or more and in two of the 66 arteries (specificity 97%) with less than 60% stenosis. Flow gaps were present in all arteries with stenosis of 70% or more. Complete occlusion was correctly identified in 10 of 10 cases. These results demonstrate that the presence of a flow gap on 2DTF-MR angiography is a reliable marker of clinically significant carotid stenosis (measuring 60% or more), with sensitivity and specificity comparable to duplex carotid ultrasound. In addition, MR angiography can be used to screen the intracranial circulation for significant vascular pathology in patients being considered for carotid endarterectomy.

Adult↗

Multislice computed tomography angiography screening for new aneurysms in patients with previously clip-treated intracranial aneurysms: Feasibility, positive predictive value, and interobserver agreement.

OBJECT: Multislice computed tomography (CT) angiography may be useful for screening patients with intracranial aneurysms that are treated with clip occlusion. However, cobalt clips produce much more artifact on CT scans than titanium clips, which may hamper the evaluation of the image obtained at the clip site. METHODS: The authors screened 415 patients with previously ruptured aneurysms that had been treated using cobalt clips. Screening was performed using multislice CT angiography. The feasibility of this modality for screening these patients (based on the complication risk, CT angiography quality, and artifact avoidance) and interobserver agreement were evaluated. Patients in whom the presence of an aneurysm was suspected based on results of CT angiography studies underwent digital subtraction (DS) angiography. False-negative and false-positive findings were recorded, and the positive predictive value (PPV) was calculated. Eight patients (1.9%) had allergies to the contrast material. The quality of the CT angiography image was suboptimal in 14%. In 52%, clip artifacts hampered evaluation of the clip site. In 65 patients who underwent DS angiography, there were nine false-positive and eight false-negative reports related to aneurysms that were either small, located at the clip site, or were infundibula. The PPV on a per-patient basis was 86% (95% confidence interval [CI] 75-94%); for aneurysms at the clip site it was 83% (95% CI 61-95%); and for aneurysms at different locations it was 91% (95% CI 81-97%). The interobserver agreement was good (kappa = 0.69; 95% CI 0.60-0.78). CONCLUSIONS: Except for the evaluation of images from the clip site, CT angiography has good feasibility with good PPV and interobserver agreement. Drawbacks are that very small aneurysms can be missed and that visualization is poor at the clip site in patients in whom cobalt clips have been placed for occlusion. This second problem can be expected to resolve with the increasing use of titanium clips.

Adult↗

[Evaluation of hemodynamic significance of arteriovenous coronary fistulas: diagnostic integration of coronary angiography and stress/rest myocardial scintigraphy].

PURPOSE: We report on the importance of the integration of data obtained from digital coronary angiography and stress/rest 99mTc sestamibi myocardial perfusion single photon emission tomography in evaluating the hemodynamic significance of coronary arteriovenous fistulae. MATERIAL AND METHODS: Coronary fistulae were detected with coronary angiography in 9 patients. All patients underwent clinical examination, transthoracic echocardiography, stress electrocardiogram and stress/rest 99mTc sestamibi myocardial perfusion single photon emission tomography. RESULTS: Stress/rest 99mTc sestamibi myocardial perfusion single photon emission tomography and stress electrocardiogram showed stress-induced myocardial ischemia in 2 patients. The first patient with familial predisposition and risk factors for ischemic heart disease presented a mesocardic heart murmur on clinical examination. At stress ECG (125 Watt, 153 b/m' max frequency 93%, arterial pressure 230 mmHg, max frequency pressure product 35,200) ischemic alterations were recorded at the first minute of the second stage of the Bruce protocol. Coronary angiography detected a circumflex artery fistula in the coronary sinus. Stress/rest 99mTc sestamibi myocardial perfusion single photon emission tomography for the evaluation of stress/rest perfusion detected a reversible perfusion defect of the proximal portion of the posterolateral and lateral walls, thus confirming the hemodynamic importance of the flow through the fistula during stress cycloergometric testing. In the second patient familial predisposition to ischemic heart disease and previous inferior wall myocardial infarction and non-significant stress ECG, coronary angiography identified a subocclusive stenosis of the right coronary artery and an anomaly between the anterior interventricular artery and the left pulmonary artery. The presence of the contrast medium in the left pulmonary artery identified a flow from the left ventricle to the left pulmonary artery. Good angiographic results were obtained after percutaneous coronary angiography of the right coronary artery stenosis. Due to the onset of angina stress/rest 99mTc sestamibi myocardial perfusion single photon emission tomography was performed to evaluate stress/rest perfusion (75 Watt, 125 b/m', 88% max frequency, arterial pressure 200 mmHg, double max product 25,000 with ST depression of 1.5 mm in V1-V4) and identified an irreversible perfusion defect due to infarction and a reversible perfusion defect of the anterior wall and apex due to ischemia caused by the anomalous flow through the coronary fistula. The correspondence between the site of the coronary artery where the fistula originates, identified by coronary angiography, and the reversible perfusion defects, identified by stress/rest 99mTc sestamibi myocardial perfusion single photon emission tomography, indicates that the anomalous flow through the fistula may cause myocardial ischemia. The irreversible perfusion defects of the inferior wall are the result of right coronary artery subocclusive stenosis. CONCLUSIONS: Coronary fistulae cause myocardial ischemia only in a small number of patients. Data obtained from single photon emission tomography in evaluating stress/rest myocardial perfusion, correlated with data from coronary angiography, have shown that changes in patients with terminal coronary anomalies may be due to different coronary diseases: ischemia to anomalous flow through the fistula and myocardial infarction to subocclusive right coronary artery stenosis. Stress/rest 99mTc sestamibi single photon emission tomography for the evaluation of myocardial perfusion is a reliable means of assessing the functional importance of the terminal coronary anomalies detected by coronary angiography. Evaluation of the hemodynamic importance of the coronary fistulae is indispensable in programming corrective surgery.

Adult↗

Three-dimensional rotational spinal angiography in the evaluation and treatment of vascular malformations.

BACKGROUND AND PURPOSE: Conventional spinal angiography, although useful in providing angioarchitectural details of spinal vascular disease, has limitations. The advent of 3D angiography has provided a better comprehension of angioarchitectural detail when evaluating the intracranial circulation. The purpose of this study was to evaluate the usefulness of 3D angiography in the diagnosis and treatment of vascular malformations of the spine. METHODS: This retrospective analysis included 17 3D spinal angiograms acquired in 14 consecutive patients examined at our institution for a spinal vascular lesion, which included nine spinal cord arteriovenous malformations (AVMs), one perimedullary arteriovenous fistula (AVF), three spinal dural AVFs, and one nerve root AVM. 3D angiography was obtained with apnea under general anesthesia by using a 14-second acquisition and 200 degrees rotation of the gantry during injection of 300 mg I/mL nonionic contrast material at a rate of 0.5-3.5 mL/s. Multiple reconstructed images were obtained with or without opacification of the surrounding structures. These images were then evaluated by the interventionalists at the time of the procedure and compared with findings obtained by conventional subtraction angiography. RESULTS: 3D angiography was useful in differentiating intramedullary lesions from perimedullary surface lesions; detecting arterial, nidal, or venous aneurysms; and evaluating the 3D structure of the lesion as well as the relationship between the malformation and its draining veins or surrounding bony structures. In specific situations, it obviated the need for contrast-enhanced conventional or 3D CT, as well as for lateral or oblique angiographic views, which are sometimes difficult to obtain with good quality. No 3D angiography-related complications were experienced. Some limitations in the definition of small vessel anatomy in the reconstructed images were noted. CONCLUSION: In this small series of patients, 3D angiography was safe and useful for evaluation of the 3D vascular anatomy of spinal vascular malformations.

Adolescent↗