Detection and separation of the S-adenosylmethionine-decarboxylase inhibitor SAM486A in human plasma and urine by reversed-phase ion-pairing high-performance liquid chromatography.

A reversed-phase ion-pairing high-performance liquid chromatography method for the detection and separation of SAM486A in human plasma and urine is described. Precipitation of proteins was used for plasma sample preparation. Enrichment of SAM486A on a 5 micro C18 column using 0.05 M NaH(2)PO(4) and 0.005 M pentan-sulfonic acid (pH 3.0) as eluent was followed by isocratic elution onto a 5 micro C18 analytical column using 0.01 M NaH(2)PO(4) and 0.005 M pentan-sulfonic acid (pH 3.0) as eluent. Analysis time was 23.0 +/- 0.1 min. The separation parameters were: capacacity factor = 6.21; plates/m = 15,002; peak tailing = 2.076. The method is linear between 5 ng/ml (detection limit) and 1000 ng/ml.

Adenosylmethionine Decarboxylase↗

ISO 17025: practical benefits of implementing a quality system.

As a laboratory certified to ISO 9001:2000 and accredited to ISO 17025, rtech laboratories has incorporated an overall system for technical and quality management, which results in benefits observed in daily laboratory practices. Technical requirements were updated to include the addition of formal personnel training plans and detailed records, method development and validation procedures, measurement of method uncertainty, and a defined equipment calibration and maintenance program. In addition, a stronger definition of the sample preparation process was documented to maintain consistency in sampling, and a more rigorous quality control monitoring program was implemented for chemistry and microbiology. Management quality improvements focused on document control to maintain consistent analytical processes, improved monitoring of supplier performance, a contract review process for documenting customer requirements, and a system for handling customer comments and complaints, with continuous improvement through corrective and preventive action procedures and audits. Quarterly management review of corrective actions, nonconforming testing, and proficiency testing aid in determining long-term trending. The practical benefits of these technical and management quality improvements are seen on a daily basis in the laboratory. Faster identification and resolution of issues regarding methods, personnel or equipment, improved customer satisfaction, meeting quality requirements of specialized customers, and overall increased laboratory business are all the result of implementing an effective quality system.

Accreditation↗

Determination of lapatinib (GW572016) in human plasma by liquid chromatography electrospray tandem mass spectrometry (LC-ESI-MS/MS).

A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 microL) were prepared using solid phase extraction (SPE) columns, and 6.0 microL of the reconstituted eluate was injected onto a Phenomenex CuroSil-PFP 3 mu analytical column (50 mm x 2.0mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC-MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N=11.3, CV< or =14%). This method was validated over a linear range of 100-10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.

Child↗

Gradient high performance liquid chromatographic assay for degradation products of adinazolam mesylate in a sustained release tablet formulation.

A gradient high performance liquid chromatographic method was developed to determine degradation products of adinazolam mesylate in a sustained release tablet formulation. Sample preparations were chromatographed on a YMC-Basic column using a formate buffer/acetonitrile gradient with absorbance detection at 254 nm. Adinazolam mesylate was found to degrade at high relative humidity and temperature to form a major product, the 6-aminoquinoline analog, plus numerous other compounds. Five of these compounds were identified and their structures indicate that the solid-state degradation of adinazolam, in the presence of sufficient moisture, involves not only a hydrolytic mechanism, but also an oxidative mechanism. Potential process impurities were resolved from the drug and degradation products. Recovery was near 100% over the 0.5 to 10% range for the major degradate (6-aminoquinoline) and over the 0.5 to 1% range for the other analytes. The method was applied to tablet samples stressed at high relative humidity and temperature. The relative standard deviation of the assay for the 6-aminoquinoline was less than 2% and less than 13% for the minor components. Calculated mass balances (sum of adinazolam plus degradation products in the degraded tablet divided by the same sum in the undegraded tablet) were less than 100% and were dependent on the extent of degradation in the tablet. The average mass balance result obtained for samples that were an average of 9.5% degraded was 95.0 +/- 1.5%. It is possible that the decrease in mass balance with increase in percent degradation may be explained by the formation of many components at trace levels due to degradation by various permutations of hydrolytic and oxidative reaction pathways.

Antidepressive Agents↗

High-performance liquid chromatography-electrospray ionization mass spectrometry method for the measurement of moclobemide and two metabolites in plasma.

A rapid and sensitive liquid chromatography-electrospray ionisation mass spectrometry (HPLC-ESI-MS) assay has been developed for the measurement of moclobemide and metabolites, Ro12-5637 and Ro12-8095, in human plasma. Sample preparation (0.5 ml plasma) involves solid-phase extraction using C18 cartridges. A Nova-Pak phenyl column (Waters, 4 microm, 150x2 mm I.D.) was employed for analyte separation with a mixture of 0.2 M ammonium formate buffer, pH 3.57 and acetonitrile as the mobile phase. The within- and between-day precisions of the assay were <18% and the limit of quantification for all analytes was 0.01 microg/ml. The total run-time was 6 min. The method described was used to measure moclobemide, Ro12-5637 and Ro12-8095 in human plasma following an oral 300 mg dose.

Antidepressive Agents↗

Robust protein quantitation in chromatographic fractions using MALDI-MS of tryptic peptides.

A method is introduced to evaluate protein concentrations using the height sum of all MALDI-MS peaks that unambiguously match theoretic tryptic peptide masses of the protein sought after. The method uses native chromatographic protein fractionation prior to digestion but does not require any depletion, labeling, derivatization, or preparation of a compound similar to the analyte. All peak heights of tryptic peptides are normalized with the peak height of a unique standard peptide added to the MALDI-MS samples. The sum of normalized peak heights, S(n), or the normalized mean peak height, M(n), reflects the concentration of the respective protein. For fractions containing various proteins, S(n) and M(n) can be used to compare concentrations of a protein between different fractions. For fractions with one predominating protein, they can be used to estimate concentration ratios between fractions, or to quantify the fractional protein concentration after calibration with pure protein solutions. Initial native fractionation retains the possibility to apply all conventional analytic procedures. Moreover, it renders the method relatively robust to MS mass accuracy. The method was validated with albumin, transferrin, alpha1-antitrypsin, and immunoglobulin G within highly complex chromatographic fractions of pathological and normal sera, which contained the respective intact native protein in dominating as well as minor concentrations. The correlation found between S(n) and the protein concentration as determined with ELISA showed that the method can be applied to select markers for distinguishing between normal and pathological serum samples.

Blood Proteins↗

Suitability of tandem-in-time mass spectrometry for polybrominated diphenylether measurement in fish and shellfish samples: comparison with high resolution mass spectrometry.

The first part of the present study focused on the development of an alternative automated sample preparation method for the measurement of selected polybrominated diphenyl ethers (PBDEs) in fish and shellfish. A previously developed automated method has been further optimized and simplified to decrease blank levels and cost. Sorbent and solvent quantities have been significantly reduced without altering extract quality. The second part of the study consisted of comparing tandem-in-time quadrupole ion storage mass spectrometry (QISTMS/MS) to high resolution mass spectrometry (HRMS) for the isotope dilution (ID) measurement step after gas chromatography (GC) separation. Both mass spectrometric methods performed similarly in terms of accuracy but better precision was observed for HRMS. Although better sensitivity can be attained with the high resolution sector instrument, method limits of quantification (mLOQs) were very similar for both approaches as they were dependent on the procedural blanks levels. The mLOQ values ranged between 0.04 and 3.56 ng/g fat, depending on the congener. They allowed the unambiguous identification and quantification of all target analytes, except for BDE-183, in most considered fish extracts. An analytical procedure based on rapid automated sample preparation and QISTMS/MS appeared to be suitable for the measurement of PBDEs in fish and shellfish speciment under quality assurance/quality control (QA/QC) criteria.

Animals↗

Fluorescence detection combined with either HPLC or HPTLC for pharmaceutical quality control in a hospital chemotherapy production unit: application to camptothecin derivatives.

In order to achieve the analytical assessment of the manufactured batches of chemotherapy preparations, post-production quality control has been developed. The common use of camptothecin derivatives (i.e. irinotecan (CPT-11) and topotecan (TPT)) as part of protocols in Institut Gustave Roussy (IGR) has led to develop an efficient analytical method that could assess an increasing number of samples with high throughput, good specificity and practicality. Due to the difference of concentration between batches containing irinotecan or topotecan, HPLC and HPTLC both combined with fluorescence detection were investigated. Those two techniques made identity, purity and quantitation assays possible. The chromatographic conditions that were chosen allowed identification of each drug through their rate of flow (Rf), 0.10 and 0.35, or their retention time (tR), 2 and 7 min for topotecan and irinotecan, respectively. A calibration curve was plotted for each molecule and validated by three quality controls (high, medium and low). Coefficients of variation of repeatability (CVr) and intermediate precision (CVi) were determined for both methods. Considering their values and the concentration ranges (from 100 to 500 mg/L for HPTLC and from 0.1 to 1 mg/L for HPLC), it was decided to perform analysis using HPTLC for irinotecan preparations and HPLC for topotecan preparations. These inferences seemed appropriate regarding the number of preparations to be assayed.

Antineoplastic Agents↗

Enzymatic mutation detection in the P53 gene.

BACKGROUND: The enzymatic mutation detection (EMD) assay uses the bacteriophage resolvase T4 endonuclease VII, which cleaves preformed heteroduplex molecules at mismatch sites, forming two shorter fragments that can be resolved by gel electrophoresis. The method can be used to detect single and multiple base changes, as well as insertions and deletions. METHODS: The sensitivity, specificity, and positional accuracy of mutation detection by EMD with the PASSPORT(TM) Mutation Scanning Kit were assessed in a blind fashion for three analytical platforms (radioactive detection and automated laser sequencers ALFexpress and ABI PRISM 377). PCR products of 703 bp covering codons 188-393 of the P53 gene were prepared from colorectal tumor samples and analyzed by EMD; the results were compared to data from cDNA sequencing. A 1362-bp PCR product prepared from IL4r gene was used to test detection of multiple base changes in long PCR products. RESULTS: The sensitivity for detection of mutations using EMD exceeded 90%, and the specificity exceeded 80% on all analysis platforms. The method localized 90% of mutations to within two codons and four codons for automated laser sequencers and detection by radioactivity, respectively. The method detected at least five mismatches in heteroduplexes >1 kb. CONCLUSIONS: The EMD system facilitates efficient detection of genetic variation in fragments exceeding 1 kb irrespective of location and type. The technology is particularly well suited to the detection of mutations in genes frequently mutated at unpredictable locations.

Colorectal Neoplasms↗

Traditional sampling with laboratory analysis and solid phase microextraction sampling with field gas chromatography/mass spectrometry by military industrial hygienists.

The opinions or assertions contained herein are the private ones of the authors and are not to be construed as official or reflecting the views of the United States Department of Defense or the Uniformed Services University of the Health Sciences. Rapid on-site detection and identification of environmental contaminants to which personnel may be exposed is often needed during military deployment situations. The availability of military industrial hygienists with capabilities for "complete" on-site exposure assessment of chemical species should allow detection and identification of a number of important stressors almost immediately following sample collection. Portable gas chromatography/mass spectrometry (GC/MS) provides a rapid and efficient separation of volatile and semivolatile organic analytes, accompanied by sensitive electron impact ionization-mass spectrometry (EI-MS) detection. The use of GC/MS in the field is limited, however, by equipment cost, complexity of the equipment, and the analytical process. Additionally, a skilled operator is needed to obtain useful separations and to interpret mass spectral data. To demonstrate benefits and limitations of "complete" exposure assessment capabilities, a previously unidentified complex mixture, produced by thermal dispersion of riot control agents, was examined. Established active sampling methods were used with laboratory analyses. Solid phase microextraction, a passive sampling method that simplifies preparation for GC/MS analysis, also was used with a field-portable GC/MS system. Both sampling/analysis methods were used to detect CS riot control agent-derived air contaminants dispersed from riot control type canisters through oxidizer-supported combustion of a chemical fuel.

Chemistry Techniques, Analytical↗

Direct background subtraction LC-MS/MS assay for human plasma progesterone: Full validation and comparative application.

OBJECTIVE: To develop and validate a liquid chromatography-tandem mass spectrometry method based on direct background subtraction for the quantification of endogenous progesterone in human plasma. METHODS: Protein precipitation was used for sample preparation with deuterated progesterone as the internal standard. Chromatographic separation was performed on an ACQUITY C18 column using gradient elution with 0.1% formic acid in water and acetonitrile at a flow rate of 0.3&#xa0;mL/min. Mass spectrometry was operated in positive electrospray ionization mode with multiple reaction monitoring. Instead of using analyte-stripped matrix or surrogate matrix, authentic plasma was directly used for all validation experiments. Quantitation was achieved by subtracting the background signal, and results were compared with those from the classical method using stripped matrix. RESULTS: Excellent linearity was achieved over 0.1-100&#xa0;ng/mL (R2&#xa0;&#x2265;&#xa0;0.99). Precision, accuracy, recovery, matrix effect, and stability all met FDA and ICH M10 acceptance criteria. Compared with the classical method, the bias in Cmax and AUC0-t was within &#xb1;15%, indicating no significant difference between the two methods. CONCLUSION: The direct background subtraction method avoids laborious preparation of blank matrix, eliminates matrix effect discrepancies, and is simple, efficient, and low-cost. It can serve as a general strategy for endogenous substance determination.

Humans↗

Analytical method for the determination of the aminoglycoside gentamicin in hospital wastewater via liquid chromatography-electrospray-tandem mass spectrometry.

A method for the determination of gentamicin residues in hospital wastewater has been developed using kanamycin as a surrogate standard. The method consists of solid-phase extraction (SPE) and detection by ion-pair chromatography with electrospray tandem mass spectrometry (LC-ES-tandem MS). The SPE was performed on a weak cation exchanger. Filtration should be avoided in the sample preparation, otherwise a significant loss of gentamicin occurs. Chromatographic separation on a C18-column was achieved using a ternary eluent containing methanol, water and 1(-1) heptafluorobutyric acid solution. Mean relative recoveries of the analytes in hospital wastewater varied between 107 and 111%. The limit of quantification (LOQ) was 0.20 microg l(-1) in hospital wastewater. Gentamicin was found in native hospital wastewater in a concentration range between 0.4 and 7.6 microg l(-1).

Anti-Bacterial Agents↗

High speed development work by preparation of an "in-hand" library of NMR-quantified degradation products.

Standard materials of impurities are needed in pharmaceutical development such as for validating impurity analytical methods. Most often the impurities possess structures, which are difficult and very time consuming to synthesize. In the present work, we demonstrate that a library of degradation products of ragaglitazar--a novel tricyclic-gamma-alkyloxyphenylpropionic acid with hypolipidemic and antidiabetic activity--observed in stability indicating samples of a solid dosage formulation by LC-MS can be produced in a one pot oxidation reaction. The library entities were isolated in small quantities (microg-mg) by preparative HPLC and structurally characterized by NMR spectroscopy and mass spectrometry. The concentrations of the library entities were determined in solution by NMR using an internal standard method. The library was successfully used in the validation work of a newly developed purity method for the drug product providing useful response factors and relative retention times (RRTs) of the degradation products.

Chromatography, High Pressure Liquid↗

Spectrofluorimetric determination of acetaminophen with N-bromosuccinimide.

A simple, sensitive, and selective method for determination of acetaminophen based on its oxidation using N-bromosuccinimide (NBS) to produce a highly fluorescent product. Optimization of reaction variables was carried out concerning NBS concentration, pH, temperature, reaction time, and stability time. Under optimal analytical conditions, the fluorescent intensity was measured at lambda emission. 442 nm (excitation at lambda 330 nm). The linearity range is 120-800 ng/mL with lower detection limit of 33.6 ng/mL acetaminophen. The method was applied successfully to the determination of the compound in pharmaceutical preparations, with average recovery of 100.3 +/- 2%. The method was also applied successfully to the determination of the drug in spiked plasma samples, with an average recovery of 101.2 +/- 1%. Interference effects of some compounds, present in combination with acetaminophen, were studied and the tolerance limits of these compounds were determined.

Acetaminophen↗

Analysis of the Fusarium mycotoxins fusaproliferin and trichothecenes in grains using gas chromatography-mass spectrometry.

A method is described using gas chromatography-mass spectrometry (GC-MS) for the simultaneous detection of the Fusarium mycotoxins fusaproliferin and seven trichothecenes from grains. Sample purification of the raw extract was carried out with commercial solid phase extraction columns, and the recovery of the more polar analytes was increased by rinsing the column with acetonitrile. A significant matrix effect was found for the analysis of fusaproliferin and trichothecenes; thus, the calibrants should be prepared in a blank matrix. The response was linear in the range used. The mean recovery for fusaproliferin was 60.4 or 62.9%, depending on the spiking level. With respect to the trichothecenes, the recovery was generally higher (70.2-125.3%). The method proved to be repeatable for the analysis of fusaproliferin and trichothecenes. The limit of detection for fusaproliferin in the blank matrix mixture was 50 microg/kg, and that for trichothecenes was 5-15 microg/kg. Thirty-eight Finnish grain samples were analyzed for fusaproliferin and trichothecenes with the method developed. Fusaproliferin was not detected in any of the samples. The mean levels of deoxynivalenol, 3-acetyldeoxynivalenol, nivalenol, HT-2 toxin, and T-2 toxin in Finnish grain samples were 272, 17, 150, 40, and <20 microg/kg, respectively.

Edible Grain↗

Isotachophoresis of CSF proteins in gel tubes especially gammaglobulins. An analytical and preparative technique for high-separation of CSF proteins.

An isotachophoretic method using polyacrylamide gel (PAG-ITP) in a simple disc electrophoretic equipment with plastic tubes containing the gels, was elaborated and especially designed for studying the gammaglobulins in CSF and serum from control subjects and patients with neurological disorders, especially known or probable MS. The device and the ITP system used, including leading and terminating electrolytes and spacer substances, dividing the gammaglobulins in a reproducible way, are described. No cooling of the gel tubes was needed. The sample volumes varied between 5--500 microliters, and the separation time was 1.5--3.0 h. CSF from patients with verified or probable MS revealed characteristic, increased low-mobility gammaglobulin fractions. Using other ITP systems, such as other spacer compositions, the anodic proteins can also be studied in more detail. PAG-ITP in gel tubes is a simple and inexpensive technique which can be used for both analytical and preparative procedures for biological material such as CSF, serum and extractions from nervous tissues.

Cerebrospinal Fluid Proteins↗

Simultaneous determination of coumarin, 7-hydroxycoumarin and 7-hydroxycoumarin glucuronide in human serum and plasma by high-performance liquid chromatography.

A HPLC method was developed for the determination of the metabolites of coumarin and 7-hydroxycoumarin in plasma and serum. Separation was based on gradient elution of 7-hydroxycoumarin glucuronide, 7-hydroxycoumarin, coumarin and finally 4-hydroxycoumarin (which is used as an internal standard). Standards, prepared in plasma or serum, and samples were treated with trichloroacetic acid, mixed and centrifuged. The supernatant was removed and analyzed by reversed-phase high-performance liquid chromatography on a C18 column. The limit of detection was 50 ng/ml for 7-hydroxycoumarin and 200 ng/ml for coumarin and 7-hydroxycoumarin glucuronide. The linear range was 0.5-100 micrograms/ml for each of the analytes. The percentage relative standard deviation about the mean measured concentrations were all below 10%. There was no statistical difference between the standard curves prepared in plasma or serum. The method developed was applied to the determination of each of the three compounds in serum, after the administration of 7-hydroxycoumarin, and in plasma after the administration of coumarin. The concentrations of total 7-hydroxycoumarin in the serum samples were also determined by another HPLC method and the results were compared. There was no statistical difference between the results determined.

Chromatography, High Pressure Liquid↗

An isotope-dilution gas chromatography-mass spectrometry method for trace analysis of xylene metabolites in tissues.

A gas chromatography-mass spectrometry (GC-MS) method using isotope dilution was developed to measure trace levels of xylene metabolites in brain tissues. The primary metabolites of xylene are dimethylphenol (DMP), methylbenzyl alcohol (MBA), toluic acid (TA), and methylhippuric acid (MHA). The internal standard was a mixture of deuterated DMP-d3, TA-d7, and MHA-d7. DMP-d3 was commercially available and was used as the internal standard for both DMP and MBA. TA-d7 and MHA-d7 were biosynthesized by administering xylene-d10 to rats and collecting their urine. Based on the noise peaks in 10 blank samples, the on-column limits of quantitation (mean +10 SD of noise peaks) were approximately 305, 1220, 545, and 386 pg for DMP, MBA, TA, and MHA, respectively. Analyte detection and recovery tests from brain tissues of control rats were conducted by spiking the tissues with 32 nmol/g of each analyte, together with the deuterated metabolites. The tissues were homogenized, extracted with ethyl acetate, and derivatized by trimethylsilylation. One microliter of the sample was injected into the GC-MS. The recoveries of the analytes were 104 +/- 8%, 80 +/- 9%, 93 +/- 10%, and 92 +/- 11% (mean +/- SD, n = 7) for DMP, MBA, TA, and MHA, respectively. The tissue preparation efficiency, which was indicated by absolute recoveries of internal standards, was approximately 33% for DMP, MBA, and TA and approximately 80% for MHA. No metabolites were detected in untreated control tissues. This simple and sensitive method to simultaneously detect major xylene metabolites in brain tissues could also be used for the analysis of blood and urine samples from workers to monitor p-xylene exposure.

Animals↗