Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “high throughput”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

High-throughput quantitation of metabolically labeled anionic glycoconjugates by scintillation proximity assay utilizing binding to cationic dyes.

Rapid, quantitative methods suited to a large number of samples are required for studies into the determination of disease etiology and in the evaluation of drugs and biological agents. This chapter describes an assay for anionic glycoconjugates (GCs), including glycosaminoglycans, which are major gene products of chondrocytes appearing in the extracellular matrix. The assay utilizes the electrostatic interaction between negatively charged sulfate and carboxyl groups of anionic GCs synthesized and secreted by chondrocytes with the cationic dye Alcian blue, immobilized to scintillant-coated 96-well plates. Metabolic labeling with D-[1, 6-3H (N)]-glucosamine allows all anionic GCs, including cartilage-specific and hyperglycosylated variants of fibronectin, to be quantitated. If Na235SO4 is used for the metabolic labeling instead, only glycosaminoglycans and proteoglycans will be quantitated. The samples are counted using a multi-detector instrument for scintillation proximity assays, such as the Wallac 1450 Microbeta Trilux, designed for detection of samples in 96-well plates and, as such, can be a high-throughput system. The bound anionic GCs can be visualized by sodium dodecyl sulfate-polyacrylamide gel electrophoresis after quantitation by elution with denaturing buffers. The method can be modified to include predigestion of the sample with a specific lyase, e.g., chondroitinase ABC or testicular hyaluronidase. To separate polyanions from other digested material after ethanol precipitation, the sample can be assayed as described in this chapter for a particular subtype of anionic GC. This assay addresses the need for high-throughput applications in arthritis and other medical and biological problems.

Alcian Blue↗

High-throughput detection of unknown mutations by using multiplexed capillary electrophoresis with poly(vinylpyrrolidone) solution.

Single-nucleotide polymorphism detection has been the focus of much attention recently. Although many methods have been reported, low-cost, high-throughput, and high-detection-rate methods are still in demand. We present a fast and reliable mutation detection scheme based on temperature-gradient capillary electrophoresis. A large temperature gradient (10 degrees C) was applied with a precision of 0.02 degrees C and a temperature ramp of 0.7 degrees C/min. Multiple unlabeled samples from PCR were injected and analyzed. Ethidium bromide was used as the intercalating dye for laser-induced fluorescence detection. Mutations can be recognized by comparing the electrophoretic patterns of the heteroduplex with that of a homoduplex reference without prior knowledge of the exact type of mutation present. Mutations in all five test samples were successfully detected with high confidence. This scheme is demonstrated in 96-capillary array electrophoresis for screening single-point polymorphism in large numbers of samples prior to full sequencing of only the positive samples to identify the nature of the mutation.

DNA↗

The investigation and the use of high flow column-switching LC/MS/MS as a high-throughput approach for direct plasma sample analysis of single and multiple components in pharmacokinetic studies.

Recently direct plasma injection LC/MS/MS technique has been increasingly used in pharmaceutical research and development due to the demand for higher throughput of sample analyses. In this work, two on-line extraction methods including high flow LC/MS/MS and high flow column switching LC/MS/MS were investigated. The evaluations were conducted and focused on their performances with respect to peak responses, separation efficiency, and signal to-noise ratio in a multiple-component LC/MS/MS assay. Two HPLC pumps were used-with one for high flow delivery and one for gradient elution. A CTC autosampler was used to inject plasma samples. High flow LC was achieved by the use of 4 ml/min flow rate on a 1 x 50 mm Waters Oasis column. A 2 x 100 mm YMC column was coupled via a column-switching valve. The extracted analytes were analyzed in multiple-reaction-monitoring (MRM) mode using a triple quadrupole MS/MS. As a rapid and simple procedure, vortex-mixing plasma and internal standard directly in sample vials completed sample preparation. The high flow column switching method (two-column system) provided sharper peak shape than the conventional high flow method. This effect increased analyte signal-to-noise ratio and sensitivity. Narrower peak width resulted in much better separation efficiency, which was required for multiple compound (N-in-1) analysis. A 2 mm I.D. column resulted in better peak shape and resolution than using a smaller I.D. column. The selected method achieved acceptable recoveries for most of the compounds tested, and it was successfully applied to a 10-in-1 pharmacokinetic (PK) study. The results showed that the dynamic range, lower limit of quantitation, assay accuracy and precision were acceptable for all compounds. Rapid sample preparation eliminated labor intensive and time consuming processes and improved productivity. This high throughput on-line extraction high flow column switching method has been proven particularly useful for multiple component analysis in PK studies.

Chromatography, Liquid↗

High-throughput screening with HyperCyt flow cytometry to detect small molecule formylpeptide receptor ligands.

High-throughput flow cytometry (HTFC), enabled by faster automated sample processing, represents a promising high- content approach for compound library screening. HyperCyt is a recently developed automated HTFC analysis system by which cell samples are rapidly aspirated from microplate wells and delivered to the flow cytometer. The formylpeptide receptor (FPR) family of G protein-coupled receptors contributes to the localization and activation of tissue-damaging leukocytes at sites of chronic inflammation. Here, the authors describe development and application of an HTFC screening approach to detect potential anti-inflammatory compounds that block ligand binding to FPR. Using a homogeneous no-wash assay, samples were routinely processed at 1.5 s/well (approximately 2500 cells analyzed/sample), allowing a 96-well plate to be processed in less than 2.5 min. Assay sensitivity and accuracy were validated by detection of a previously documented active compound with relatively low FPR affinity (sulfinpyrazone, inhibition constant [K(i)]=14 microM) from among a collection of 880 compounds in the Prestwick Chemical Library. The HyperCyt system was therefore demonstrated to be a robust, sensitive, and highly quantitative method with which to screen lead compound libraries in a 96-well format.

Flow Cytometry↗

Development of a high-throughput fluorescence polarization assay for Bcl-x(L).

Antiapoptotic protein Bcl-x(L) has been demonstrated to play a very important role in a variety of diseases such as cancer. Its biological function can be inhibited by proapoptotic proteins such Bak, Bad, and Bax by forming complexes mediated primarily by the Bcl-2 homology 3 (BH3) domain. To facilitate drug discovery for Bcl-x(L) inhibitors, we have developed and optimized a fluorescence polarization assay based on the interaction between Bcl-x(L) and BH3 domain peptides. We observed that the fluorescein-labeled Bad BH3 peptide [NLWAAQRYGRELRRMSDK(fluorescein)FVD or fluorescent Bad peptide] generates best overall results. Fluorescent Bad peptide interacts strongly with Bcl-x(L) with a K(d) of 21.48nM. The assay is stable over a 24-h period and can tolerate the presence of dimethyl sulfoxide up to 8%. By using a competition assay, several peptides derived from the BH3 region of Bak, Bad, Bax, and Bcl-2 were investigated. Bad and Bak BH3 peptides compete efficiently with IC(50) values of 0.048 and 1.14 microM, respectively, while the peptides from the BH3 region of Bcl-2 and Bax compete weakly. A mutated Bak peptide, which has been shown to be inactive for binding to Bcl-x(L), did not compete. The relative binding order of the peptides (Bad>Bak>Bcl-2>Bax>mutated Bak) correlates well with previously published results. When tested in high-throughput formats, the assay has a signal-to-noise ratio of 15.37 and a Z(') factor of at least 0.73. The plate-to-plate variability for free peptide control and bound peptide control is minimal. This validates the assay not only for investigating the nature of Bcl-x(L)-peptide interaction, but also for high-throughput screening of Bcl-x(L) inhibitors.

Binding, Competitive↗

Development of a facile method for high throughput screening with reporter gene assays.

This report describes a facile methodology for high throughput screening with stable mammalian cell reporter gene assays. We have adapted a 96-well adherent cell method to an assay in which cells propagated in suspension are dispensed into 96- or 384-well plates containing test compounds in 100% DMSO. The validation of a stable CHO cell line that expresses 6xCRE-luciferase for use as a reporter gene host cell line is described. The reporter gene, when expressed in this particular CHO cell line, appears to respond specifically to modulation of cAMP levels, thus the cell line is appropriate for screening and pharmacological analysis of Galpha(s)- and Galpha(i)-coupled seven-transmembrane receptors. The development of the new suspension cell assay in both 96- and 384-well formats was performed using a derivative of the CHO host reporter cell line that was stably transfected with human melanocortin-1 receptor. The response of this cell line to NDP-alpha-melanocyte-stimulating hormone and forskolin was nearly identical between the adherent and suspension methods. The new method offers improvements in cost, throughput, cell culture effort, compound stability, accuracy of compound delivery, and hands-on time. The 384-well assay can be performed at high capacity in any laboratory without the use of expensive automation systems such that a single person can screen 100 plates per day with 3.5-4 h hands-on time. Although the system has been validated using Galpha(s)-coupled receptor-mediated activation of a cAMP response element, the method can be applied to other types of targets and/or transcriptional response elements.

Animals↗

Tube-gel digestion: a novel proteomic approach for high throughput analysis of membrane proteins.

This study describes a new protein digestion protocol in which a variety of detergents can be used to solubilize membrane proteins and facilitate trypsin digestion with higher efficiency. In this protocol, proteins are dissolved in solutions containing various detergents and directly incorporated into a polyacrylamide gel matrix without electrophoresis. Detergents are subsequently eliminated from the gel matrix while proteins are still immobilized in the gel matrix. After in-gel digestion of proteins, LC-MS/MS is used to analyze the extracted peptides for protein identification. The uniqueness of the protocol is that it allows usage of a variety of detergents in the starting solution without interfering with LC-MS/MS analysis. We hereby demonstrate that different detergents, including ionic SDS, non-ionic Triton X-100 and n-octyl beta-d-glucopyranoside, and zwitterionic CHAPS, can be used to achieve maximum solubilization of membrane proteins with minimal interference with LC-MS/MS analysis. Enhanced digestions, i.e. improved number and intensity of detected peptides, are also demonstrated for digestion-resistant proteins such as myoglobin, ubiquitin, and bacteriorhodopsin. An additional advantage of the Tube-Gel digestion protocol is that, even without electrophoresis separation, it allows high throughput analysis of complex protein mixtures when coupled with LC-MS/MS. The protocol was used to analyze a complex membrane protein mixture prepared from prostate cancer cells. The protocol involves only a single digestion and 2.5 h of LC-MS/MS analysis and identified 178 membrane proteins. In comparison, the same membrane fraction was resolved by SDS-PAGE, and 20 gel slices were excised and individually digested and analyzed by LC-MS/MS. The more elaborate effort demanded more than 50 h of LC-MS/MS analysis and identified 268 proteins. The new Tube-Gel digestion protocol is an alternative method for high throughput analysis of membrane proteins.

Amino Acid Sequence↗

Discovery of cercosporamide, a known antifungal natural product, as a selective Pkc1 kinase inhibitor through high-throughput screening.

The Pkc1-mediated cell wall integrity-signaling pathway is highly conserved in fungi and is essential for fungal growth. We thus explored the potential of targeting the Pkc1 protein kinase for developing broad-spectrum fungicidal antifungal drugs through a Candida albicans Pkc1-based high-throughput screening. We discovered that cercosporamide, a broad-spectrum natural antifungal compound, but previously with an unknown mode of action, is actually a selective and highly potent fungal Pkc1 kinase inhibitor. This finding provides a molecular explanation for previous observations in which Saccharomyces cerevisiae cell wall mutants were found to be highly sensitive to cercosporamide. Indeed, S. cerevisiae mutant cells with reduced Pkc1 kinase activity become hypersensitive to cercosporamide, and this sensitivity can be suppressed under high-osmotic growth conditions. Together, the results demonstrate that cercosporamide acts selectively on Pkc1 kinase and, thus, they provide a molecular mechanism for its antifungal activity. Furthermore, cercosporamide and a beta-1,3-glucan synthase inhibitor echinocandin analog, by targeting two different key components of the cell wall biosynthesis pathway, are highly synergistic in their antifungal activities. The synergistic antifungal activity between Pkc1 kinase and beta-1,3-glucan synthase inhibitors points to a potential highly effective combination therapy to treat fungal infections.

Amphotericin B↗

Workflow improvement and impact of the new Beckman Coulter LH 1500 high throughput automated hematology workcell.

Our core laboratory at St. Joseph's Medical Center (SJMC) recently installed the new Beckman Coulter LH 1500 fully automated hematology workcell. Like many laboratories in North America and other parts of the world, we are under significant pressure to improve productivity, reduce costs, and improve service provision to our hospital and clinician bases. The difficulty of meeting this challenge is often further compounded by an increasing shortage of qualified technologist personnel. We recently reported on the significant productivity gains with the introduction of the LH 750 hematology system into the core laboratory, including a 23% reduction in slide review rate, automation of reticulocyte and nucleated red blood cell counts, and an 82% increase in the pass-through rate. Evolution to the next stage of automation has come much quicker than anticipated owing to a steep rise in workload and an ever increasing shortage of trained and experienced technologists to fill vacancies in the 24-hour core laboratory operation. We chose to upgrade our LH 750 analyzers to the newly introduced LH 1500 hematology workcell in order to cope with the increased workload and shortage of available experienced hematology technologists. The LH 1500 is a compact, high throughput, fully automated hematology workcell. It is designed to automate all manual process and handling steps associated with hematology analyses, including sample sorting, loading and unloading of cassettes, automatic rerun and reflex testing, sample storage, and tracking of samples. The LH 1500 is comprised of a minimum of 2, and up to 4, LH 750 instruments (with or without integrated slidemaker/stainers). The instruments are bidirectionally interfaced and linked to a fully automated conveyor track, specimen inlet and outlet stations, a sample stockyard, and a line controller. The configuration we chose at SJMC incorporates 1 LH 750 and 1 LH 755. We report that the upgrade to the LH 1500 was a relatively straightforward process and required no redesign of the core laboratory. Based on our evaluation, we estimate cost savings with the LH 1500 of between three quarters to 1 full-time equivalent, which eliminated or decreased many manual handling steps. In addition, this increase in efficiency has freed up our technologist resources to concentrate on the more difficult and clinically important samples. This is the first published report on the new LH 1500 hematology workcell. Our research indicates that the LH 1500 is the first hematology workcell to offer hematology laboratories the next level of automation and virtually eliminate preanalytical and postanalytical sample handling and sorting. For core laboratories and high-throughput hematology laboratories that face similar pressures to ours, the LH 1500 would appear as an attractive solution to maximize hematology productivity and improve service delivery.

Automation↗

High-throughput drug screening of the DPC4 tumor-suppressor pathway in human pancreatic cancer cells.

OBJECTIVE: To screen a library of small chemicals for compounds that activate the DPC4 signal transduction pathway in a human pancreatic cancer cell line. SUMMARY BACKGROUND DATA: Various tumor-suppressor genes are mutated in all human cancers. Specifically, DPC4 (deleted in pancreatic carcinoma, locus 4 or MADH4/SMAD4) is a tumor-suppressor gene mutated in approximately 50% of human pancreatic adenocarcinomas. DPC4 plays an important role in the well-studied transforming growth factor-beta (TGFbeta) signaling pathway. It would be useful to identify therapies that augment or restore the downstream functions of this critical signal transduction pathway, in hopes that such therapy would have a rational role in anticancer therapy. METHODS: Using a commercially available plasmid vector with a luciferase reporter gene already incorporated, a DPC4-specific reporter construct was genetically engineered. This was done by inserting six copies of the palindromic Smad binding element (6SBE), which is a DNA binding element specific for DPC4, in front of the minimal promoter in the plasmid. This construct was then stably integrated into the genome of a human pancreatic cancer cell line (PANC-1) that has wild-type DPC4. Several stably transfected clones were tested for basal luciferase expression and inducibility with TGFbeta, which is known to activate the DPC4 signal transduction pathway. A single transfected clone was chosen for the drug screen based on basal luciferase (reporter) expression and TGFbeta inducibility. A systematic screen of the chemical library was then performed, using luciferase activity to detect DPC4 activity and induction of the signaling pathway. RESULTS: A high-throughput system based on this stably integrated reporter system was used to screen a library of 16,320 random compounds to identify agents that conferred robust augmentation of the DPC4 signal transduction pathway. Of the 16,320 compounds screened, 11 were associated with a 2- to 5-fold induction of luciferase activity, and one with a 12-fold activation. The latter compound was shown to be a novel histone deacetylase inhibitor and was further characterized. CONCLUSIONS: These results confirm the feasibility of a specific high-throughput reporter system to screen a large compound library in human cells efficiently. The screening identified several compounds capable of augmenting DPC4-specific luciferase reporter activity, and a specific mechanism for one compound was identified. The discovery of such agents will aid our understanding of complex tumor-suppressive signaling pathways and may identify other potential therapeutic targets within this critical signaling pathway. In addition, random drug screening provides an unbiased method for identifying drugs or lead compounds for potential therapeutic use.

Adenocarcinoma↗

Combinatorial approaches as a component of high-throughput experimentation (HTE) in catalysis research.

We consider the application of high-throughput experimentation (HTE), including combinatorial methods, to catalyst discovery and early-phase optimization. While combinatorial- and parallel-testing methods have an already substantial history in catalysis, recent work by several groups promises significant efficiency gains. In molecular catalysis, progress is noted in library design, library synthesis by pooled, parallel, and discrete formats, catalyst testing and reaction optimization; the prime constraint for organometallic catalysts is the limited scope of synthesis procedures for non-peptide-based ligand libraries. Routes described for the synthesis of heterogeneous catalysts include hydrothermal synthesis, arraying of solution precursors, automated impregnation and precipitation, and arraying of solid precursors. The key challenge in applying HTE to heterogeneous catalysis is testing; we distinguish here between Stage 1, or "discovery" testing and Stage 2, optimization testing, and describe techniques with potential in each case. Recent examples from the literature and our own work are used to illustrate these principles and the prospects for HTE applied to catalysis.

Catalysis↗

High-throughput characterisation of materials by photoluminescence spectroscopy.

An automatic system for high-throughput (HT) characterisation of large libraries of solid materials by photoluminescence spectroscopy is described. The system provides time-resolved transient emission spectra in the microsecond scale and can be employed for characterisation of materials of interest in the fields of catalysis and electroluminescence, amongst others. Here, we present its application to the optimisation of the ship-in-a-bottle synthesis of a novel electroluminescent polymer (PPV) and a photocatalyst (TP+), both encapsulated in large-pore zeolites.

Catalysis↗

Assay of rotenone in river water by high-throughput tandem mass spectrometry and multiple-reaction monitoring methodology.

The high-throughput analytical approach proposed for the assay of rotenone in lake and river waters presented here is based on atmospheric pressure chemical ionization (APCI) multiple-reaction monitoring (MRM) methodology whereby the analyte and internal standard solutions are directly analyzed, without any previous chromatographic separation. The very good accuracy is obtained by the critical choice of a reference compound that shows gas-phase chemistry similar to that of the analyte, by producing the same product ions selected for the MRM-based assay.

Atmosphere↗

MicroTom--a high-throughput model transformation system for functional genomics.

We have developed a high-throughput Agrobacterium-mediated transformation model system using both nptII and the 5-enolpyruvylshikimate-3-phosphate synthase gene from Agrobacterium tumefaciens strain CP4 (cp4) based selections in MicroTom, a miniature rapid-cycling cherry tomato variety. With the NPTII selection system, transformation frequency calculated as independent transgenic events per inoculated explant ranged from 24 to 80% with an average of 56%, in industrial production scale transformation experiments. For CP4, with glyphosate selection, the average transformation frequency was 57%. Stable transformation frequency was positively correlated with transient expression (R=0.85), and variable with the genes of interest. DNA integration and germline transformation were confirmed by biological assay, Southern Blot analysis, and R(1) phenotype segregation. Transgene expression was observed in leaf, root, stem, flower, and fruit tissues of the transgenic plants. Ninety-five percent of transgenic events coexpressed two introduced genes based on beta-glucuronidase (GUS) and neonmycin phosphotransferase II (NPTII) expression. Seventy-five percent of transgenic events contained one to two copies of the introduced uidA (GUS) gene based on Southern analysis. Transgenic plants from the cotyledon explants to the transgenic plants transferred to soil were produced within about 2-3 months depending on the genes of interest. The utility of this MicroTom model transformation system for functional genomic studies, such as identification of genes related to important agricultural traits and gene function, is discussed.

3-Phosphoshikimate 1-Carboxyvinyltransferase↗

Development and evaluation of real competitive PCR for high-throughput quantitative applications.

Real competitive PCR (rcPCR) has been shown to have high sensitivity, reproducibility, and high-throughput potential. We describe further development and evaluation of this methodology as a tool for measuring nucleic acid abundance within a cell. Modifications to the original protocol allow analysis of gene expression levels using standard conditions regardless of mRNA abundance and assay type, thereby increasing throughput and ease of reaction setup while decreasing optimization time. In addition, we have developed a software package, TITAN, to automatically analyze the results. The details are relevant to researchers performing competitive PCR using any detection technique. The effectiveness of the described developments is demonstrated using 12 genes known to have differential expression in cell lines grown under normal and hypoxic conditions. Quantitative and qualitative comparisons to real-time PCR are presented. It is also demonstrated that the technique is capable of detecting submicroscopic chromosomal DNA deletions.

Breast Neoplasms↗

Metalloproteomics: high-throughput structural and functional annotation of proteins in structural genomics.

A high-throughput method for measuring transition metal content based on quantitation of X-ray fluorescence signals was used to analyze 654 proteins selected as targets by the New York Structural GenomiX Research Consortium. Over 10% showed the presence of transition metal atoms in stoichiometric amounts; these totals as well as the abundance distribution are similar to those of the Protein Data Bank. Bioinformatics analysis of the identified metalloproteins in most cases supported the metalloprotein annotation; identification of the conserved metal binding motif was also shown to be useful in verifying structural models of the proteins. Metalloproteomics provides a rapid structural and functional annotation for these sequences and is shown to be approximately 95% accurate in predicting the presence or absence of stoichiometric metal content. The project's goal is to assay at least 1 member from each Pfam family; approximately 500 Pfam families have been characterized with respect to transition metal content so far.

Binding Sites↗

Advanced transfection with Lipofectamine 2000 reagent: primary neurons, siRNA, and high-throughput applications.

Lipofectamine 2000 is a cationic liposome based reagent that provides high transfection efficiency and high levels of transgene expression in a range of mammalian cell types in vitro using a simple protocol. Optimum transfection efficiency and subsequent cell viability depend on a number of experimental variables such as cell density, liposome and DNA concentrations, liposome-DNA complexing time, and the presence or absence of media components such as antibiotics and serum. The importance of these factors in Lipofectamine 2000 mediated transfection will be discussed together with some specific applications: transfection of primary neurons, high throughput transfection, and delivery of small interfering RNAs.

Animals↗

High-throughput screening of structural proteomics targets using NMR.

We applied a high-throughput strategy for the screening of targets for structural proteomics of Xanthomonas axonopodis pv citri. This strategy is based on the rapid (1)H-(15)N HSQC NMR analysis of bacterial lysates containing selectively (15)N-labelled heterologous proteins. Our analysis permitted us to classify the 19 soluble candidates in terms of 'foldedness', that is, the extent to which they present a well-folded solution structure, as reflected by the quality of their NMR spectra. This classification allowed us to define a priority list to be used as a guide to select protein candidates for further structural studies.

Bacterial Proteins↗