Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamic range”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Simultaneous quantitation of multiple cytokine mRNAs by RT-PCR utilizing plate based EIA methodology.

Cytokines are small protein hormones produced during an immune response that are responsible for mediation and regulation of many aspects of immunity. Measurement of cytokines by several different methods has led to a broader understanding of the immune response. This paper describes a sensitive, reproducible, and quantitative RT-PCR assay for the simultaneous measurement of multiple cytokines. The main features of the methodology are: RNA competitors which control for all aspects of the process from RNA extraction, through reverse transcription (RT) and PCR amplification; a general cloning vector, pQPCR1, for building RNA competitors that does not require prior analyte cDNA cloning; and analysis by plate based EIA. This RT-PCR-EIA system is shown to be more sensitive than agarose gel electrophoresis followed by EtBr staining, measuring PCR product in the sub-nanogram range. It also extends the linear dynamic range of detection to a four log fold range of analyte concentration. The assay is reproducible, with coefficients of variation (CVs) in the 10-20% range. Moreover, the cloning vector is designed to accommodate multiple primer templates, thus allowing simultaneous quantitation of many different analytes from a single RT reaction. The described system is versatile and adapts to numerous analytes.

Animals↗

Solid-phase and bead-based cytokine immunoassay: a comparison.

Cytokines and chemoattractive cytokines (chemokines) are present in a wide variety of body fluids such as plasma, cerebrospinal fluid, bronchoaveolar fluid, amniotic fluid, synovial fluid, middle ear effusion fluid, and urine. Cytokines can be detected using classical solid-phase sandwich immunoassays such as enzyme-linked immunosorbent assay (ELISA) or with a bead based multiplex immunoassay (MIA). The physical chemical properties of the different body fluids (such as pH and total protein content) differ, which may have an impact on the outcome of the cytokine assay. Both ELISA as well as MIA cytokine detection systems are constructed by sandwiching the protein of interest between a capture and reporter antibody. When the biological sample contains heterophilic antibodies (such as in patients with auto-immune diseases), these non-specific antibodies can cause false positive results. During pathological conditions, cytokines may be found over a wide concentration range; likewise have to cover this dynamic range in a similar fashion. The correct (statistical) analysis of standard curves and (multiplexed) data are critical for proper interpretation. Classical ELISA based cytokine assays are robust, easy to use and very well suited for measurement of single cytokines. Due to an increased interest in the integral approach to understand biological processes (the omics era), multiplex immunoassays for detection of cytokines and the interpretation of these assays are gaining popularity.

Animals↗

Macaque thresholds for detecting increases in intensity: effects of formant structure.

Macaque monkeys, like humans, are more sensitive to differences in formant frequency than to differences in the frequency of pure tones (see Sinnott et al. (1987) J. Comp. Psychol. 94, 401-415; Pfingst (1993) J. Acoust. Soc. Am. 93, 2124-2129; Prosen et al. (1990) J. Acoust. Soc. Am. 88, 2152-2158; Sinnott et al. (1985) J. Acoust. Soc. Am. 78, 1977-1985; Sinnott and Kreiter (1991) J. Acoust. Soc. Am. 89, 2421-2429; for summary, see May et al. (1996) Aud. Neurosci. 3, 135-162). In the discrimination of formant frequency, it appears that the relevant cue for macaque monkeys is relative level differences of the component frequencies (Sommers et al. (1992) J. Acoust. Soc. Am. 91, 3499-3510). To further explore the result of Sommers et al., we trained macaque monkeys (Macaca fuscata) to report detection of a change in the spectral shape of multi-component harmonic complexes. Spectral shape changes were produced by the addition of intensity increments. When the amplitude spectrum of the comparison stimulus was modeled after the /ae/ vowel sound, thresholds for detecting a change from the comparison stimulus were lowest when intensity increments were added at spectral peaks. These results parallel previous data from human subjects, suggesting that both human and monkey subjects may process vowel spectra through simultaneous comparisons of component levels across the spectrum. When the subjects were asked to detect a change from a comparison stimulus with a flat amplitude spectrum, the subjects showed sensitivity that was relatively comparable to that of human subjects tested in other investigations (e.g. Zera et al. (1993) J. Acoust. Soc. Am. 93, 3431-3441). In additional experiments, neither increasing the dynamic range of the /ae/ spectrum nor dynamically varying the amplitude of the increment during the stimulus presentation reliably affected detection thresholds.

Animals↗

High-throughput lipophilicity measurement with immobilized artificial membranes.

We report on a new, high-throughput assay designed to measure octanol/water partition coefficients in early drug discovery. The assay is carried out in 96-well microtiterplates and measures the diffusion of compounds between two aqueous compartments separated by a thin octanol liquid layer. Octanol/water partition coefficients are derived from the apparent permeability (P(a)) values using a calibration curve. The assay can measure partition coefficients within the range -2 to + 8; thus, a dynamic range of 10 log units can be covered in one single run. Unlike chromatographic methods, the technology is not restricted to neutral and weakly basic compounds, and, as no stationary phase is involved, the data can be strictly compared with values obtained from traditional methods such as shake-flask/HPLC or dual-phase potentiometric titration.

1-Octanol↗

Identification and quantification of metabolites of arachidonic acid from cultures of endothelial cells by HPLC-MS2.

Epoxyeicosatrienoic acids (EETs) and hydroxyeicosatetraenoic acids (HETEs) are oxidative products of arachidonic acid, some of which participate in the regulation of vascular tone. Little is known about the production of EETs and HETEs in cultures of endothelial cells. This paper reports an assay for the simultaneous quantification of isomers of EETs and HETEs from endothelial cell culture supernatants by employing solid-phase extraction and liquid chromatography-mass spectrometry. The method enabled measurement of 5,6-EET, 8,9-EET, 11,12-EET, 14,15-EET, 5-HETE, 8-HETE, 11-HETE, 12-HETE and 15-HETE. The metabolites were chromatographically separated by reversed-phase HPLC and identified by negative ESI tandem mass spectrometry and this method was used to investigate the metabolism of arachidonic acid with an endothelial cell line. For quantification, the sum of signal intensities of characteristic fragment ions was used. The detection limits for 5,6-EET and of other EET and HETE isomers were 2.0, 0.64 and 8 ng ml(-1) culture medium, respectively. The precision of the method was determined with spiked culture medium (three concentrations, n = 5) and the average RSD ranged from 6.0 to 24.2%. The dynamic range was 0.6-23.5 ng ml(-1) culture medium for EETs and 8.0-200 ng ml(-1) for HETEs. Arachidonic acid was mainly metabolised to HETEs with product levels ranging from 59.3 to 460 ng 10(-6) cells. The median of 8,9-EET and 14,15-EET was 14.5 and 17.7 ng 10(-6) cells, respectively, whereas 5,6-EET and 11,12-EET were below 2 ng 10(-6) cells in a 5-min incubation assay at a 30 microM arachidonic acid substrate concentration.

Arachidonic Acid↗

A real-time flat-panel X-ray pixel imaging system for low-dose medical diagnostics and craniofacial applications.

The aim of this study was to evaluate on-line performance of a real-time digital imaging system based on amorphous silicon technology and to compare it with conventional film-screen equipment. The digital detecting imager consists of (1) a converter, which transforms the energy of the incident X rays into light; (2) a real-time digital detecting system, capable of producing as many as 10 pictures per second using a large-area pixel matrix (20 x 20 cm2) based on solid-state amorphous silicon sensor technology with a pitch of 400 microns; and (3) appropriate computer tools for control, real-time image treatment, data representation, and off-line analysis. Different phantoms were used for qualitative comparison with the conventional film-screen technique, with images obtained with both systems at the normal dose (used as a reference), as well as with dose reduction by a factor of 10 to 100. Basic image quality parameters evaluated showed that the response of the detector is linear in a wide range of entrance air kerma; the dynamic range is higher compared with the conventional film-screen combination; the spatial resolution is 1.25 lp per millimeter, as expected from the pixel size; and good image quality is ensured at doses substantially lower than for the film-screen technique. The flat-panel X-ray imager based on amorphous silicon technology implemented in standard radiographic equipment permits acquisition of real-time images in radiology (as many as 10 images per second) of diagnostic quality with a marked reduction of dose (as much as 100 times) and better contrast compared with the standard film technique. Preliminary results obtained with a 100-micron pitch imager based on the same technology show better quality but a less substantial dose reduction. Applications in craniofacial surgery look promising.

Analog-Digital Conversion↗

Plasticity of dorsal horn cell receptive fields after peripheral nerve regeneration.

1. The tibial and sural nerves were transected and repaired in nine adult cats. The receptive field (RF) properties of dorsal horn neurons were examined at three different intervals (5-6, 9, or 12 mo) after axotomy. The properties examined included RF location, area, and modality convergence. In some cases, discrete areas of the cell's RF were stimulated electrically while the evoked cord dorsum potentials (CDPs) and any intracellularly recorded responses were simultaneously recorded. 2. At the shortest interval following reinnervation, the somatotopic organization in the affected areas of the dorsal horn was lost. Dorsal horn cells that received input primarily from regenerated fibers had large, low-threshold excitatory RFs that contained much of the reinnervated skin. Those cells with RFs restricted to a fraction of the reinnervated skin had significant components of their RFs on the foot dorsum supplied by intact fibers (i.e., superficial peroneal nerve). 3. At longer intervals the somatotopic organization remained scrambled. Dorsal horn cell low-threshold RFs were significantly reduced in size. Many cells exhibited large areas of excitatory subliminal fringe and concise inhibitory RFs. In addition, those cells that responded to peripheral stimuli across a wide range of stimulus intensities (wide-dynamic-range cells) also exhibited plasticity in the relative sizes of their low- and high-threshold RFs. 4. At the shortest recovery time, focal electrical stimulation of the skin within the RF of an impaled cell and simultaneous recordings of the evoked CDPs and postsynaptic potentials revealed that at numerous locations within the initial large RFs, single fibers or small groups of fibers could be electrically activated that were not connected to the dorsal horn cell. At the longer recovery times there was a much higher incidence of connectivity. 5. These results suggest that mechanisms affecting both synaptic efficacy of afferent fiber connections and/or the establishment of afferent-driven inhibitory inputs may effect the reshaping of dorsal horn cell RFs after reinnervation. These results are discussed in relation to their potential contribution to previously observed cortical plasticity and functional recovery following similar lesions.

Animals↗

[Biophysical and pharmacological characterization of receptor-operated nonselective cation channels (ROCC) and their regulatory mechanisms in smooth muscle].

Stimulation of excitatory receptors in smooth muscle often leads to the opening of ROCC. These channels exhibit considerable permeability to Ca2+, and they have been regarded as the most probable candidate for the "receptor-operated Ca2+ entry" pathway. The muscarinic receptor ROCC in guinea pig ileum (mROCC) have a unitary conductance of -25pS and are activated through a pertussis toxin-sensitive G protein. mROCC permeate Ca2+ and Ba2+ several fold more preferably than monovalent cations, and they are inhibited by various types of K channel blockers, diphenylamine-2-carboxylate derivatives and even by nicardipine and D-600 at high concentrations. mROCC are efficiently regulated by various physiological factors including the membrane potential, intracellular Ca2+ concentration, external pH and osmolarity. The effective ranges of these factors span their dynamic ranges under physiological conditions. In addition to these properties, mROCC have several sites sensitive to external polyvalent cations. The alpha 1-adrenergic receptor ROCC in rabbit portal vein resemble mROCC in many respects, e.g., the unitary conductance, ionic selectivity, activation kinetics, sensitivity to polyvalent cations and voltage-dependence. These complex characteristics of ROCC suggest that they play other roles in addition to being just a passive cation permeable pore in agonist-mediated Ca2+ mobilization in smooth muscle.

Animals↗

Fiber interferometer for simultaneous multiwavelength phase measurement with a broadband femtosecond laser.

We present a fiber interferometer for the simultaneous measurement of phase at multiple wavelengths from a single broadband femtosecond laser. Narrow-bandwidth fiber Bragg gratings isolate a particular frequency from the broad-bandwidth laser pulse produced. The multiwavelength phase data permit the unambiguous measurement range to be significantly increased compared with the wavelengths used in the interferometer. Preliminary experimental results are presented for a two-frequency sensor with an absolute range of 0.13 mm and associated dynamic range of 43,000:1.

Journal Article↗

Feasibility study on the detection of ferritin using surface plasmon resonance.

Determination of ferritin concentration was performed using surface plasmon resonance technique. An anti-human ferritin antiserum from rabbits was immobilized on the protein-A coated sensor chip. The resonance change due to the binding of ferritin to the antibody was measured. It was found that the antigen-antibody binding of the ferritin could be monitored in real time. The detection of ferritin could be obtained in the range of 25-800 ng/ml. This dynamic range could be applied in various medical applications. Moreover, it was observed that the sensor chips could be regenerated. This offers an opportunity for multiple uses, which will reduce the unit operating cost.

Antigen-Antibody Reactions↗

[Progress in charge-coupled device and its applications].

Charge-coupled device (CCD) is a photosensitive element based on the metal-oxidesemiconductor technology. Currently, it has a number of benefits; broad spectral range response, low detection limit, wide dynamic range, minimal dark current and readout noise as well as abilities of signal integration, simultaneous multichannel detection and real-time detection. In this paper, the operational principle, features and performance characterization of CCD are introduced and its applicaton in spectral detection and spectral imaging are veiwed. The development of CCD technique has brought a revolutionary progress in the spectroscopic areas. Its future developments are also outlooked.

Electrochemistry↗

The psychoacoustics of profound hearing impairment.

A group of profoundly hearing-impaired adults is being studied in order to determine their residual auditory capabilities. Most tests use acoustic contrasts that have relevance for the perception of speech, so that the results obtained may be used to guide the development of appropriate hearing aids. All the listeners are postlingually deafened, with losses greater than 95 dB HL at and above 500 Hz, and least loss at low frequencies. Trends in detection thresholds, discomfort levels, dynamic ranges, intensity discrimination (both static and dynamic), frequency selectivity, spectral shape discrimination, gap detection, tone/noise discrimination, frequency discrimination and phase sensitivity are reported and discussed. Generally speaking, temporal resolving power seems to be more resistant to degradation than mechanisms of frequency selectivity. Furthermore, at least some of the differences in performance between normal and profoundly-impaired listeners may be attributable to the loss of frequency selectivity. Implications are drawn for hearing aid fitting and design, and comparisons made to the electro-auditory abilities of users of single-channel cochlear implants.

Adult↗

Quantitative evaluation of proteins in one- and two-dimensional polyacrylamide gels using a fluorescent stain.

The characteristics of protein detection and quantitation with SYPRO Ruby protein gel stain in one- and two-dimensional polyacrylamide gels were evaluated. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analyses of three different purified recombinant proteins showed that the limits of detection were comparable to the limits of detection with ammoniacal silver staining and were protein-specific, ranging from 0.5 to 5 ng. The linearity of the relationship between protein level and SYPRO Ruby staining intensity also depended on the individual protein, with observed linear dynamic ranges of 200-, 500-, and, 1000-fold for proteins analyzed by SDS-PAGE. SYPRO Ruby protein gel stain was also evaluated in two-dimensional electrophoretic (2-DE) analysis of Escherichia coli proteins. The experiment involved analysis of replicates of the same sample as well as dilution of the sample from 0.5 to 50 nug total protein across gels. In addition to validating the 2-DE system itself, the experiment was used to evaluate three different image analysis programs: Z3 (Compugen), Progenesis (Nonlinear Dynamics), and PDQuest (Bio-Rad). In each program, we analyzed the 2-DE images with respect to sensitivity and reproducibility of overall protein spot detection, as well as linearity of response for 20 representative proteins of different molecular weights and pI. Across all three programs, coefficients of variation (CV) in total number of spots detected among replicate gels ranged from 4 to 11%. For the 20 representative proteins, spot quantitation was also comparable with CVs for gel-to-gel reproducibility ranging from 3 to 33%. Using Progenesis and PDQuest, a 1000-fold linear dynamic range of SYPRO Ruby was demonstrated with a single known protein. These two programs were more suitable than Z3 for examining individual protein spot quantity across a series of gels and gave comparable results.

Bacterial Proteins↗

Acoustic analysis of the voice in pediatric cochlear implant recipients: a longitudinal study.

OBJECTIVE: To characterize inherent acoustic abnormalities of the deaf pediatric voice and the effect of artificially restoring auditory feedback with cochlear implantation. DESIGN: Inception cohort. SETTING: Academic referral center. PATIENTS: Twenty-one children with severe to profound hearing loss (15 prelingually deaf, 6 postlingually deaf) accepted into the cochlear implant program were followed for up to 6 months. Patients unable to perform the vocal exercises were excluded. INTERVENTIONS: Objective voice analysis was performed using the Computerized Speech Laboratory (Kay Elemetrics) prior to cochlear implantation, at the time of implant activation and at 2 and 6 months postactivation. Assessments were based on sustained phonations and dynamic ranges. MAIN OUTCOME MEASURE: Fundamental frequency, long-term control of fundamental frequency (vF0) and long-term control of amplitude (vAM) were derived from sustained phonations. The dynamic frequency range was derived from scale exercises. Formant frequencies (F1, F2, F3) were determined using linear predictive coding. RESULTS: Fundamental frequency was not altered by implant activation or experience (P = 0.342). With profoundly deaf subject, the most prevalent acoustic abnormality was a poor long-term control of frequency (vF0, 2.81%) and long-term control of amplitude (vAm, 23.58%). Implant activation and experience had no effect on the long-term control of frequency (P = 0.106) but normalized the long-term control of amplitude (P = 0.007). The mean frequency range increased from 311.9 Hz preimplantation to 483.5 Hz postimplantation (P = 0.08). The F1/F2 ratio remained stable (P = 0.476). CONCLUSION: In children, severe to profound deafness results in poor long-term control of frequency and amplitude. Cochlear implantation restores control of amplitude only and implies the need for additional rehabilitative strategies for restoration of control of frequency.

Acoustics↗

Dynamic exchange coupling in magnetic bilayers.

A long-range dynamic interaction between ferromagnetic films separated by normal-metal spacers is reported, which is communicated by nonequilibrium spin currents. It is measured by ferromagnetic resonance and explained by an adiabatic spin-pump theory. In such a resonance the spin-pump mechanism of spatially separated magnetic moments leads to an appreciable increase in the resonant linewidth when the resonance fields are well apart, and results in a dramatic linewidth narrowing when the resonant fields approach each other.

Journal Article↗

Analysis of complex protein mixtures with improved sequence coverage using (CE-MS/MS)n.

Identification of proteins, in a complex protein mixture, using one-dimensional high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis of its digest, usually suffers from low sequence coverage. There are several reasons for the low coverage including undersampling, wide concentration dynamic range of the proteins in a complex protein mixture, and wide range of electrospray ionization efficiency of peptides under each mobile-phase composition. To address this low sequence coverage, we introduce a novel technique, (CE-MS/MS)n, which utilizes the most significant advantages of CE-MS/MS, including economy of sample size, fast analysis time, and high separation efficiency, to increase the sequence coverage of a complex protein mixture. Based on these characteristics, (CE-MS/MS)n can be performed in which multiple CE-MS/MS subanalyses (injections followed by analyses) are analyzed and experimental variables are manipulated during each CE-MS/MS subanalysis in order to maximize sequence coverage. (CE-MS/MS)n is a practical technique since each CE-MS/MS subanalysis consumes <10 nL, and each CE-MS/MS subanalysis takes approximately 10 min; therefore, several subanalyses can be performed in approximately 1 h consuming only nanoliters of the sample. Two techniques have been introduced to address the undersampling: (1) (CE-MS/MS)n using dynamic exclusion. In this technique, several CE-MS/MS analyses (injection followed by separation) were performed in one run using the dynamic exclusion capability of the mass spectrometer until all peptide peaks were analyzed by MS/MS. (2) Gas-phase fractionation. In this technique, (CE-MS/MS)n is performed by scanning a narrow mass range (every approximately 100 m/z) during each CE-MS/MS subanalysis without using dynamic exclusion. Under this condition, in each subanalysis, the number of peptides available for MS/MS analysis is significantly reduced, and peptides with the same nominal masses are analyzed, thereby increasing sequence coverage. Additionally, to address the lack of detection of low-level peptides in a mixture containing a wide concentration dynamic range, the concentration of the sample was systematically increased in each subanalysis (while utilizing dynamic exclusion) so that low-intensity peptides would rise above the mass spectrometer threshold and, consequently, undergo MS/MS analysis. Moreover, to alter the ionization efficiency of peptides with low electrospray ionization efficiency, and to change the migration behavior of comigrating peptides under a specific liquid composition, the CE background electrolyte was modified in several subanalyses to further improve sequence coverage. The combination of the above-mentioned techniques was applied to the analysis of the tryptic digests of three well-characterized protein mixtures: a six-protein mixture with average MW of approximately 26,000 (standard I), a six-protein mixture with an average MW approximately 49,000 (standard II), and a more complex protein mixture containing 55 proteins (E. coli ribosomal proteins). In approximately 1 h, when the MS/MS of the peptides were manually checked, all peptides that produced peaks under electrospray ionization in the scanned range of the analysis (500-2000 m/z) and within the practical fragmentation capability of the MS (peptides with MW <3500) were identified for standard I by consuming only 200 fmol of each protein. When searched against a Swissprot database, the average sequence coverage for the standard I, II, and E. coli's ribosomal proteins were 57, 34, and 15%, respectively.

Amino Acid Sequence↗

Receptor potentials of isolated frog muscle spindle evoked by sinusoidal stimulation.

Receptor potentials in response to sinusoidal stimulation have been recorded from isolated muscle spindles of the frog. Sinusoidal displacements of different amplitudes (20-120 micron) and frequencies (0.1-100 Hz) were used. The mean static stretch level was adjusted between resting length (L0) and L0 + 400 micron, so that the amplitude and phase-response characteristics were measured at different operating points. Depending on the amount of static prestretch, there is a well-defined dynamic range, which limits the receptor potential by nonlinear compression of either its positive or negative half-cycle. For each point on the static operating curve there exists a dynamic operating curve with a sigmoidal shape. The range of each dynamic curve is approximately 80 micron, independent of the static displacement, and the maxima of all dynamic curves are the same. Therefore the dynamic curves are not symmetrical about their static operating point. The slope of the steepest portion is 10% of the maximum elicitable receptor potential per 10-micron dynamic displacement. For stimulus frequencies greater than 2 Hz the receptor potential deviates from a sinusoidal waveform, exhibiting a fast depolarization transient during stretch and a prolonged repolarization transient during release of stretch. The steepness of the depolarization transient increases with increasing stimulus frequency, amplitude, and prestretch level. As a result, the interval from trough to peak of the receptor potential shortens to less than 90 degrees instead of half a cycle. The repolarization transient has an exponential decay with a time constant of approximately 40 ms that remains constant during the various stimulus conditions. As a result of this slow decay time, individual receptor potentials summate, so that the response divides into a modulated receptor potential (AC component) and a maintained depolarization (DC component). The amplitude response characteristic of the stationary AC component increases with increasing stimulus frequencies up to a peak at 2 Hz, after which it declines with a slope of -3 dB/octave. Provided large sinusoidal stretches and/or extended prestretch levels are used, this high-frequency decline of the AC component is compensated for by the proportional increase of the DC component, so that the peak depolarization values remain constant from 2 to 100 Hz. Stimulus and response are in phase for stimulus frequencies less than 2 Hz and reverse to phase lag at higher stimulus frequencies.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

The potential of inductively coupled plasma mass spectrometry detection for high-performance liquid chromatography combined with accurate mass measurement of organic pharmaceutical compounds.

Quantification of unknown components in pharmaceutical, metabolic and environmental samples is an important but difficult task. Most commonly used detectors (like UV, RI or MS) require standards of each analyte for accurate quantification. Even if the chemical structure or elemental composition is known, the response from these detectors is difficult to predict with any accuracy. In inductively coupled plasma mass spectrometry (ICP-MS) compounds are atomised and ionised irrespective of the chemical structure(s) incorporating the element of interest. Liquid chromatography coupled with inductively coupled plasma mass spectrometry (LC/ICP-MS) has been shown to provide a generic detection for structurally non-correlated compounds with common elements like phosphorus and iodine. Detection of selected elements gives a better quantification of tested 'unknowns' than UV and organic mass spectrometric detection. It was shown that the ultrasonic nebuliser did not introduce any measurable dead volume and preserves the separation efficiency of the system. ICP-MS can be used in combination with many different mobile phases ranging from 0-100% organic modifier. The dynamic range was found to exceed 2.5 orders of magnitude. The application of LC/ICP-MS to pharmaceutical drugs and formulations has shown that impurities can be quantified below the 0.1 mol-% level.

Chromatography, High Pressure Liquid↗