Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Coupling between muscle activities and muscle torques during horizontal-planar arm movements with direction reversal.

In this study we investigated the hypothesis that the simple set of rules used to explain the modulation of muscle activities during single-joint movements could also be applied for reversal movements of the shoulder and elbow joints. The muscle torques of both joints were characterized by a triphasic impulse. The first impulse of each joint accelerated the limb to the target and was generated by an initial burst of the muscles activated first (primary mover). The second impulse decelerated the limb to the target, reversed movement direction and accelerated the limb back to the initial position, and was generated by an initial burst of the muscles activated second (secondary movers). A third impulse, in each joint, decelerated the limb to the initial position due to the generation of a second burst of the primary movers. The first burst of the primary mover decreased abruptly, and the latency between the activation of the primary and secondary movers varied in proportion with target distances for the elbow, but not for the shoulder muscles. All impulses and bursts increased with target distances and were well coupled. Therefore, as predicted, the bursts of muscle activities were modulated to generate the appropriate level of muscle torque.

Adaptation, Physiological↗

The effects of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis muscle.

The purposes of this investigation were to examine the effects of electrode placement and innervation zone (IZ) location on: (a) the torque-related patterns of responses for absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) and (b) the mean absolute and normalized EMG amplitude and MPF values. In addition, the present study examined the variability between subjects for the location of the IZ for the vastus lateralis (VL). Eight men (mean+/-SD age=23.0+/-4.3yr) performed submaximal to maximal isometric muscle actions of the dominant leg extensors. During each muscle action, fifteen channels of bipolar surface EMG signals were detected from the vastus lateralis using a linear electrode array aligned with the long axis of the muscle fibers. The results indicated that there were differences among channels 1-15 for the patterns of responses and mean values for absolute and normalized EMG amplitude and MPF versus isometric torque. Thus, normalized EMG amplitude and MPF values from different individuals cannot be compared if the EMG signals were detected from different locations over the muscle. In addition, absolute and relative (to femur length) estimates of IZ location for the VL resulted in similar inter-subject variability.

Adult↗

Comparison of the fast Fourier transform and continuous wavelet transform for examining mechanomyographic frequency versus eccentric torque relationships.

The purpose of this study was to compare the eccentric torque-related patterns for mechanomyographic (MMG) center frequencies (mean power frequency (MPF), median frequency (MDF), and average instantaneous mean power frequency (AIMPF)) determined by the fast Fourier transform (FFT) and continuous wavelet transform (CWT). Eight adults (mean+/-S.D. age=22.5+/-2.4 years) performed submaximal to maximal, eccentric isokinetic muscle actions of the biceps brachii on a Cybex 6,000 dynamometer. The mean MMG MPF, MDF, and AIMPF values for both the absolute and normalized data from 10 to 100% eccentric peak torque (PT) were highly intercorrelated at r=0.908-0.985. Linear models provided the best fit for the absolute MMG MPF (r=0.873), MDF (r=0.831), and AIMPF (r=0.924), as well as normalized MMG MPF (r=0.869), MDF (r=0.816), and AIMPF (r=0.920) versus percentage eccentric PT relationships. There were no significant differences (p>0.05) among the linear slope coefficients for the MMG MPF, MDF, and AIMPF versus percentage eccentric PT relationships for either the absolute or normalized data. These results suggested that Fourier or wavelet transform procedures can be used to examine the patterns of MMG responses during eccentric muscle actions of the biceps brachii.

Adult↗

The effect of duty cycle and frequency on muscle torque production using kilohertz frequency range alternating current.

We investigated the frequency and duty cycle dependence of maximal electrically induced torque (MEIT) of the wrist extensors. Fifty hertz burst modulated sinusoidal alternating current (AC) in the frequency range 0.5-20 kHz was used, with duty cycles ranging from a minimum (one cycle) to maximum (continuous AC). MEITs were similar at low frequencies but decreased markedly above 2.5 kHz. MEITs also decreased markedly above a 20% duty cycle. Subjective reports of discomfort were fewest at 4 kHz and at duty cycles in the range 20-25%. Our conclusion is that for maximum torque production, a frequency of 1 kHz and a duty cycle of 20% are indicated. When comfort is a major consideration, a frequency of 2.5 kHz provides an acceptable trade-off between MEIT and comfort. The findings also suggest that low duty cycle, burst modulated AC stimulation may be more effective than stimulation using conventional low-frequency pulsed current.

Electric Stimulation Therapy↗

Evaluating the effects of interface factors on the torque exertion capabilities of operating handwheels.

This study intends to assess factors affecting human torque exertion capabilities of operating valve handwheels (maximum volitional torque exertion of wrist radial/ulnar deviation, R/U MVTE). Forty student subjects (20 males and 20 females) participated in this study. In addition to gender and subject factors, gloves (one layer of cotton, two layers of cotton and rubber gloves), operating height (elbow, shoulder and overhead), handwheel size and shape were selected. Barehanded condition was also involved. The results indicate that all the main effects and the first order interactions were significant. The gloved R/U MVTEs were found to be greater than the barehanded R/U MVTE. For operating height, shoulder height gave the greatest R/U MVTE, followed by elbow and overhead heights. The handwheel diameters ranging from 75 to 95 mm for males and 65 to 80 mm for females were found to have the greater R/U shear force. The average R/U MVTE of operating valve handwheel for females was about 63% (3.8/6.05) of that of males.

Accidents, Occupational↗

Torque resistance of the passive tissues of the trunk at axial rotation.

Sitting in a twisted working posture is common when driving an agricultural tractor in the field. To be able to twist backwards, the driver has to overcome the torque from the passive tissues (passive resistance). The purpose of this investigation was to determine the relationship between passive resistance at axial rotation and twisting angle of the trunk when a person is seated. Ten healthy tractor drivers and 10 healthy office workers were passively twisted about the cranio-sacral axis with simultaneous measurements of the torque needed to twist them and the twisting angle. Surface electromyogram was used to control the relaxation of the muscles of the subjects. An exponential function was fitted to the data, which shows that passive resistance increases progressively with twisting angle. No significant differences in trunk passive resistance due to the subject's occupation, direction of twist or their interactions could be found. The fitted function is useful when assessing the load in the trunk in tractor driving, but also for other occupational activities where the trunk is twisted.

Abdomen↗

Factors affecting the variability of the torque curves at isokinetic trunk strength testing.

OBJECTIVES: To evaluate the relation between variability of the torque curves and factors such as age, gender, measurement speeds, and period from low back pain (LBP) onset at isokinetic trunk strength testing. DESIGN: Observational. SETTING: Hospital. PATIENTS: One hundred forty-three consecutive LBP patients (acute, subacute, and chronic) who received physical therapy, and 200 healthy volunteer subjects. MAIN OUTCOME MEASURES: The variability of the torque curves is an indicator of consistency of effort, and was measured as the coefficient of variance (CV) at different measurement speeds in isokinetic trunk flexion/extension strength testing. RESULTS: The CV was lower in men than in women at the faster measurement speed. LBP patients had higher CV values than healthy subjects. The CV was different according to gender and measurement speed, but not different according to age and periods from LBP onset. CONCLUSION: The CV was affected by measurement speed and gender, but not by age or period from LBP onset. Because the CV was higher in LBP patients than in healthy subjects, this value may be usable as an adjunctive index of LBP.

Abdomen↗

The relative contribution to the plantar-flexor torque of the soleus motor units activated by the H reflex and M response in humans.

This study proposes a method of quantifying the relative contribution to the plantar-flexor torque of soleus H and M responses evoked by tibial nerve stimulation. For ten subjects, the amplitude of the twitch produced by the H wave was plotted against the corresponding potential, for stimuli producing H without M (i.e. in the ascending portion of the H-recruitment curve). It was then assumed that the contribution of H to twitches produced by M plus H was similar for similar H waves on the curve-descending portion. Hence, the contribution of M was estimated, for the range of M waves including those accompanying H(max). The estimated mechanical contributions of H and M wave increase linearly with their potentials, the slope of the relationship being greater for H than M. The interpretation of this finding is discussed. A simple formula for assessing the contribution of the H wave to the twitch torque is given.

Action Potentials↗

Deficits in phasic muscle force generation explain insufficient compensation for interaction torque in cerebellar patients.

A simple paradigm was used to investigate how patients with cerebellar lesions cope with the need to correct for joint interactions during a multi-joint movement. Normal subjects and patients with cerebellar degeneration performed fast unconstrained elbow flexions with the instruction to voluntarily fixate the shoulder joint. Angular kinematics and inverse dynamics analyses were performed. A susceptibility index quantified how strong-concomitant shoulder-motion depended on interactions from the elbow. Amplitudes of involuntary shoulder movements increased with elbow movement speed and were generally larger in patients. Susceptibility indices were smaller in patients, indicating a more variable compensatory response, however, increased with elbow movement speed. We conclude that patients were significantly less able to 'tune' their postural stabilizing response to match interaction torques. However, the velocity dependence of this effect points to a deficit in generating normal levels of phasic torque.

Adult↗

Rheological characterization of microcrystalline cellulose and silicified microcrystalline cellulose wet masses using a mixer torque rheometer.

The rheological properties of silicified microcrystalline cellulose (Prosolv 50) were compared with those of standard grades of microcrystalline cellulose (Emcocel 50 and Avicel PH 101). Cellulose samples were analyzed using nitrogen adsorption together with particle size, flowability, density and swelling volume studies. The rheological behaviour of the wet powder masses was studied as a function of mixing time using a mixer torque rheometer (MTR). Silicified microcrystalline cellulose exhibited improved flow characteristics and increased specific surface area compared to standard microcrystalline cellulose grades. Although the silicification process affected the swelling properties and, furthermore, the mixing kinetics of microcrystalline cellulose, the source of the microcrystalline cellulose had a stronger influence than silicification on the liquid requirement at peak torque.

Cellulose↗

Changes in isokinetic torque and muscular activity of elbow flexors muscles with age.

This study examined the influence of aging on torque-angular velocity relationships for elbow flexion and the corresponding muscular activity levels in order to target the mechanisms involved in the eccentric muscle action in older adults. Maximal constant angular torque (CAT) at 90 degrees was measured at different angular velocities for concentric (CON; 60, 120, 180, 240 degrees s(-1)), isometric (ISO) and eccentric (ECC; -60, -120 degrees s(-1)) elbow flexor muscle actions in older (OG; 6 females and 4 males, 64-82 years) and young adult subjects (YG; 6 females, 6 males, 19-24 years) on an isokinetic dynamometer. Myoelectrical activity was quantified on biceps and triceps muscles, using the root mean square (RMS) procedure over a range of 30 degrees motion (75-105 degrees ). Absolute CAT was significantly greater (p<0.04) for YG in comparison with OG for all types of actions (CON, ECC, ISO). The only effect of gender concerned absolute strength values (p=0.00007). However, the OG showed higher (p<0.001) relative CAT values (expressed as percentage of CON 60 degrees s(-1) value) during ECC muscle action than the YG. Nevertheless, RMS values for elbow flexors were significantly (p<0.03) lower in the OG than in the YG. The antagonist (triceps) co-activation was similar for both groups. The relative ECC force preservation with aging seems to be independent of a muscular activation phenomenon.

Adult↗

Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws.

When screws are inserted in thick cortical bone, a small pilot hole size, corresponding to the core diameter of the screw, can result in high torsional stress, leading to screw fracture. The aim of this study was to enlarge the drill size up to a critical pilot hole size (CPHS) which, if exceeded, means a rapid decrease in the screw holding power. 1.5 and 2 mm titanium screws were inserted in discs of polyvinylchloride (PVC), wood and porcine mandibular bone with thicknesses differing between 2 to 4 mm, using an increasing pilot hole size between 66% and 95% of the screw external diameter. Torque measurements and pullout tests were performed and the CPHS was calculated. In torque measurements, the CPHS of microscrews ranged between 83% and 85% of the screw external diameter (SED). The CPHS of miniscrews lay between 80% and 90% of SED. In pullout analysis, the CPHS of microscrews ranged between 83% and 89% of SED; the CPHS of miniscrews lay between 79% and 91% of SED. The mean of the CPHS was calculated to be approximately 85% of the SED. Up to this critical point, the pilot hole size may be increased without affecting the holding power of the screws.

Animals↗

Two-couple orthodontic appliance systems: torquing arches.

Twists placed in an arch wire between incisor brackets are often used in an attempt to obtain root torque. This is only partially effective because of the equal and opposite reciprocals acting on the adjacent teeth. Alternatively, a V-bend in a torquing arch, inserted at only the molar and incisor brackets, may use the bending properties of the arch wire to create dissimilar moments in a two-bracket system. If the greater moment is present at the incisors, all of the incisors are rotated en masse in the same direction, with the associated equal and opposite vertical equilibrium forces directed at the incisors and molars. The lesser moment at the molar also usually has equilibrium forces that may reduce or supplement vertical forces at the molar and incisor depending on the magnitude and direction of the moment present. If the arch wire is unrestrained the resulting tooth movement shows rotation of the incisors around the CRes and movement of the CRes in the direction of the vertical equilibrium force present. The alternative use of a single force to rotate incisor crowns facially results in a reciprocal distal force at the posterior teeth and rotation of the incisors with a center of rotation apical to the CRes.

Dental Stress Analysis↗

Histomorphometric and removal torque analysis for TiO2-blasted titanium implants. An experimental study on dogs.

The aim of the present study was to compare the anchorage of TiO2-blasted screw and cylindrical implants with conventionally used machine-produced screw and cylindrical implants inserted immediately in extraction sockets on dogs. 6 adult mongrel dogs had 3rd and 4th mandibular premolars extracted bilaterally and 24 commercial pure titanium implants were placed immediately in extraction sockets and covered with mucoperiosteum. Each dog had inserted 4 implants: 1 screw implant and 1 cylindrical implant blasted with titanium-dioxide-particles; 1 screw implant and 1 cylindrical implant with machine-produced (m.p.) surface (controls). After a healing period of 12 weeks, 16 implants from 4 animals were used for removal torque test, which demonstrated that significantly higher removal torque force was needed to unscrew the implants blasted with titanium-dioxide-particles, than the normal m.p. implants. The medians for the TiO2-blasted screw and cylindrical implants were > 150 Ncm and 105 Ncm, respectively, while the values for the m.p. implants were 60 Ncm and 35 Ncm, respectively. The SEM investigation demonstrated a high irregularity of the TiO2-blasted surface compared to the machined surface. The Ra and Rz values for surface roughness were higher for the TiO2-blasted implants than for the normal m.p. implants. Histomorphometrically, the arithmetic mean of the direct bone-implant contact fraction was 69%. There was no significant difference in direct bone-implant contact length fraction between TiO2-blasted implants and the control implants. The implants blasted with titanium-dioxide-particles in this study showed a better anchorage than implants with a machine-produced surface. The screw implants showed a better anchorage than the cylindrical implants.

Animals↗

Anticipating load torques produced by voluntary movements.

The stability of an object held between the finger and thumb depends on friction developed by grip force, normal to the contact surfaces, to overcome tangential load force. Previous research has shown that in lifting an object, grip force rises with the increase in gravitational load force as the hand takes the weight and that in moving an object, grip force is adjusted to meet movement-induced inertial load force. Those results demonstrated the anticipatory nature of coordination of grip force with load force. Whether grip force anticipates load torque was studied in this research. When participants were constrained to use grasp points where the grasp axis was manifestly distant from object center of mass, it was found that they made grip force adjustments in anticipation of load torques that tended to destabilize an object as a result of lifting or moving it. These adjustments imply use of information about object center of mass in movement planning.

Adolescent↗

Torque-generating units of the flagellar motor of Escherichia coli have a high duty ratio.

Rotation of the bacterial flagellar motor is driven by an ensemble of torque-generating units containing the proteins MotA and MotB. Here, by inducing expression of MotA in motA- cells under conditions of low viscous load, we show that the limiting speed of the motor is independent of the number of units: at vanishing load, one unit turns the motor as rapidly as many. This result indicates that each unit may remain attached to the rotor for most of its mechanochemical cycle, that is, that it has a high duty ratio. Thus, torque generators behave more like kinesin, the protein that moves vesicles along microtubules, than myosin, the protein that powers muscle. However, their translation rates, stepping frequencies and power outputs are much higher, being greater than 30 microm s(-1), 12 kHz and 1.5 x 10(5) pN nm s(-1), respectively.

Bacterial Proteins↗

Excitations of incoherent spin-waves due to spin-transfer torque.

The possibility of exciting microwave oscillations in a nanomagnet by a spin-polarized current, as predicted by Slonczewski and Berger, has recently been demonstrated. This observation opens important prospects of applications in radiofrequency components. However, some unresolved inconsistencies are found when interpreting the magnetization dynamics within the coherent spin-torque model. In some cases, the telegraph noise caused by spin-currents could not be quantitatively described by that model. This has led to controversy about the need for an effective magnetic temperature model. Here we interpret the experimental results of Kiselev et al. using micromagnetic simulations. We point out the key role played by incoherent spin-wave excitation due to spin-transfer torque. The incoherence is caused by spatial inhomogeneities in local fields generating distributions of local precession frequencies. We observe telegraph noise with gigahertz frequencies at zero temperature. This is a consequence of the chaotic dynamics and is associated with transitions between attraction wells in phase space.

Computer Simulation↗

Lever-arm and mini-implant system for anterior torque control during retraction in lingual orthodontic treatment.

Anterior torque control during retraction is difficult to achieve with lingual orthodontic treatment. This article describes the use of a lever-arm and mini-implant system as absolute anchorage for controlled retraction of the anterior teeth during lingual orthodontic treatment and evaluates 2 protrusion cases treated with this system. Various clinical situations are discussed and analyzed from a biomechanical standpoint. Mini-implants are needed to control the point of force application in the posterior area and produce en masse retraction with no anchorage loss. When the length of the lever-arm is adjusted to the position of the mini-implant, the desired line of action of the retraction force with respect to the center of resistance of the anterior segment is selected. Controlled retraction of the anterior teeth was achieved with no loss of anchorage. The mini-implant, in conjunction with the lever-arm, is useful not only for absolute anchorage but also for anterior torque control during retraction in lingual orthodontic treatment.

Adult↗