Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Thermometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

[Comparison of noninvasive MRT procedures for temperature measuremnt for the application of medical heat therapies].

Novel methods for hyperthermia tumor therapy, such as high-intensity focused ultrasound (HIFU) or laser-induced thermotherapy (LITT), require accurate non-invasive temperature monitoring. Non-invasive temperature measurement using magnetic resonance imaging (MRI) is based on the analysis of changes in longitudinal relaxation time (T1), diffusion coefficient (D), or water proton resonance frequency (PRF). The purpose of this study was the development and comparative analysis of the three different approaches of MRI temperature monitoring (T1, D, and PRF). Measurements in phantoms (e.g., ultrasound gel) resulted in the following percent changes: T1-relaxation time: 1.98%/degree C; diffusion coefficient: 2.22%/degree C; and PRF: -0.0101 ppm/degree C. All measurements were in good agreement with the literature. Temperature resolutions could also be measured from the inverse correlation of the data over the whole calibration range: T1: 2.1 +/- 0.6 degrees C; D: 0.93 +/- 0.2 degree C; and PRF: 1.4 +/- 0.3 degrees C. The diffusion and PRF methods were not applicable in fatty tissue. The use of the diffusion method was restricted due to prolonged echo time and anisotropic diffusion in tissue. Initial tests with rabbit muscle tissue in vivo indicated that MR thermometry via T1 and PRF procedures is feasible to monitor the local heating process induced by HIFU. The ultrasound applicators in the MR scanner did not substantially interfere with image quality.

Body Temperature↗

Actions of BW540C in an equine model of acute inflammation: a preliminary study.

An equine model of acute non-immune inflammation has been developed to facilitate studies of the inflammatory process and the actions of novel anti-inflammatory drugs. Five polyester sponge strips soaked in sterile 2% carrageenin solution were placed in subcutaneous pouches prepared under local anaesthesia in the necks of conscious ponies. Serial removal of the strips and harvesting of the exudate enabled studies to be made of the cellular, biochemical and mediator aspects of the localised, acute inflammation, and the heat generated by the lesion was monitored by infra-red thermometry. Maximal concentrations of the eicosanoids 6-keto-prostaglandin F1 alpha, thromboxane B2 and leukotriene B4 occurred at 9 h, whereas leukocyte numbers, lactate dehydrogenase (LDH) and total protein concentrations were greatest at 24 h. Lesional skin temperature was increased by approximately 4 degrees C throughout the 24 h period. The novel anti-inflammatory agent BW540C, administered orally at a dose-rate of 20 mg/kg, did not affect leukocyte infiltration or the concentrations of protein, LDH and eicosanoids in exudate but serum thromboxane B2 levels were reduced. Skin temperature rises were greater in drug-treated animals. It is concluded that higher doses of BW540C will be required for a clinically useful anti-inflammatory action in horses.

6-Ketoprostaglandin F1 alpha↗

Control system for an MRI compatible intracavitary ultrasound array for thermal treatment of prostate disease.

A 16-channel ultrasound intracavitary array is currently being used in a clinical setting for localized hyperthermia treatment of prostate tumours. Currently, the individual power to each array element is adjusted based on the clinician's judgement of the temperature measured at the locations of invasive thermocouple probes. MRI-derived temperature measurements may be useful for a feedback control system that non-invasively regulates the temperature distribution by adjusting the power to the elements of the array. MRI has been shown to provide accurate, high resolution, non-invasive thermometry. A proportional-plus-integral, single-input, single-output controller was designed to evaluate the feasibility of MRI-derived temperature feedback with this applicator. Input parameters for the controller were determined by modelling the tissue response to the heating from the array. Ex vivo and in vivo experiments evaluated the ability of the MRI-based temperature feedback control system to achieve and maintain a target temperature for a sustained period similar to that of a clinical hyperthermia treatment. With the controller set to a reference temperature of 43 degrees C and a rise time of 6 min, the temperatures within the ex vivo tissue (n = 6) were 43.1 +/- 0.3 degrees C after reaching the reference temperature and had a rise time of 9.5 +/- 0.3 min. In vivo results using rabbit thigh muscle (n = 7) showed that the steady state temperatures were within +/- 1 degree C of their target temperatures. These results demonstrated the feasibility of a temperature feedback for controlling the heating from an intracavitary transrectal array based on temperature information from MR images.

Animals↗

Using units of CEM 43 degrees C T90, local hyperthermia thermal dose can be delivered as prescribed.

A randomized study was designed in dogs with spontaneous soft tissue sarcomas to gain information about the relationship between hyperthermia dose and outcome. The study compared two levels of thermal dose applied to dogs with heatable tumours, so it was necessary to deliver either a low (2-5 CEM 43 degrees C T90) or high (20-50 CEM 43 degrees C T90) thermal dose as precisely as possible. It was also desirable to have similar numbers of hyperthermia treatments in each thermal dose group. Identification of heatable tumours and randomization to high or low heat dose group was done during the first hyperthermia treatment. This was readily accomplished using mapping of temperatures in thermometry catheters, manual recording of thermal data, and visual inspection of raw thermal data with subsequent adjustment of the duration of the hyperthermia treatment. An analysis of precision of thermal dose delivery was conducted after approximately 50% of projected accrual had been met in a randomized phase III assessment of thermal dose effect. Fifty-four dogs were eligible for randomization; in 48 dogs the tumour was deemed heatable according to predetermined temperature criteria applied during the first heat treatment. Twenty-four dogs were randomized to the high heat dose group, and 24 to the low heat dose group. Median (range) total thermal dose for dogs in the high dose group was 43.5 CEM 43 degrees C T90 (16.4-66.6) compared to 3.2 CEM 43 degrees C T90 (2.1-4.6) for dogs in the low dose group. There was no overlap of thermal doses between groups. Thus, thermal dose could be delivered accurately, being within the predetermined range in 47 of the 48 dogs. Thermal dose quantified as CEM 43 degrees C T50, however, did overlap between groups and the clinical significance of this finding will not be known until outcome data are analysed. Most dogs in both groups received five hyperthermia treatments. Median (range) treatment duration for dogs in the high dose group was 300 min (147-692) compared to III min (51-381) for dogs in the low dose group. Relatively simple but accurate methods of delivering prescribed thermal dose as described herein will aid the translation of clinical hyperthermia from the research setting into more general practice once the characteristics of the relationship between hyperthermia dose and outcome are understood.

Animals↗

A phase II trial testing the thermal dose parameter CEM43 degrees T90 as a predictor of response in soft tissue sarcomas treated with pre-operative thermoradiotherapy.

We prospectively evaluated whether delivering a thermal dose of > 10 cumulative equivalent minutes at 43 degrees C to >90% of the tumour sites monitored (CEM43 degrees T90) would produce a pathologic complete response (pCR) in > 75% of high-grade soft tissue sarcomas treated pre-operatively with thermoradiotherapy. The impact of thermal dose on local failure (LF), distant metastasis (DM), and toxicity was also assessed. Thirty-five patients > or = 18 years old with grade 2 or 3 soft tissue sarcomas accessible for invasive thermometry were enrolled on the protocol. All patients received megavoltage external beam radiotherapy (RT) in daily fractions of 1.8-2.0 Gy, five times a week, to a median total dose of 50 Gy and an initial hyperthermia treatment (HT) of I h duration utilizing the BSD 2000 with Sigma 60 or MAPA applicators at frequencies of 60-140 MHz. Further HT was given for patients with CEM43 degrees T90 > 0.5 after initial HT ('heatable' patients), twice a week to a maximum of 10 HT or CEM43 degrees T90 > 100. Of the 35 patients entered, 30 had heatable tumours, one of which was inevaluable for pCR or LF as the patient died of DM prior to surgery, leaving 29 evaluable patients. Of these 29 patients, 15 (52%) had a pCR (95% CI: 37-73%), significantly less than the projected rate of > or = 75% (p = 0.02). Of the 25 heatable tumours that achieved CEM43 degrees T90 > or = 10, 14 (56%) had a pCR (95% CI: 39-78%) significantly less than the projected rate (p = 0.06). Three of the 29 patients (10%) with heatable tumours had a LF, versus 1/5 unheatable tumours (p = 0.48). Fourteen of the 30 patients (47%) with heatable tumours developed DM, versus 2/5 unheatable tumours (p = 1.00). Ten of the 30 patients (33%) with heatable tumours developed treatment-induced toxicity. Thus, no correlation of thermal dose with histologic response was observed. Prospective control of CEM43 degrees T90 failed to achieve the projected pCR rate following pre-operative thermoradiotherapy for high-grade soft tissue sarcomas, despite excellent local control. Possible explanations for this outcome are discussed.

Adult↗

3D numerical reconstruction of the hyperthermia induced temperature distribution in human sarcomas using DE-MRI measured tissue perfusion: validation against non-invasive MR temperature measurements.

Essential to the success of optimized thermal treatment during hyperthermia is accurate modelling. Advection of energy due to blood perfusion significantly affects the temperature. Without accurate estimates of the magnitude of the local tissue blood perfusion, accurate estimates of the temperature distribution can not be made. It is shown here that the blood mass flow rate per unit volume of tissue in the Pennes' bio-heat equation can be modelled using a relative perfusion index (RPI) determined with dynamic-enhanced magnetic resonance imaging (DE-MRI). Temperature distributions in two patients treated with hyperthermia at Duke University Medical Center for high-grade leg tissue sarcomas are modelled, and the resultant temperatures are compared to measured temperatures using a non-invasive MR thermometry technique. Significant correlations are found between the DE-MRI perfusion images, the MR temperature images, and the numerical simulation of the temperature field. The correlation between DE-MRI measured values and advective heat loss in tissue is used to scale the perfusion distribution, thereby allowing the continuum model to account for the local thermal impact of vasculature in the tumour. Large vessels in tumour and neighbouring healthy tissue need to be taken into account in order to accurately describe the complete temperature distribution.

Chemotherapy, Cancer, Regional Perfusion↗

Non-invasive temperature profile estimation in a lossy medium based on multi-band radiometric signals sensed by a microwave dual-purpose body-contacting antenna.

Microwave radiometry has during the past two decades been investigated as a non-invasive scheme for measurement of subcutaneous tissue temperatures, basically for monitoring and control in hyperthermic treatment of cancer. In this effort, we test a contact-type, dual-purpose antenna with integral water bolus. To overcome conflicting optimization criteria in the integration of this thermometry technique with heat applicators exhibiting a large effective field size during superficial hyperthermia, a stacked configuration design is proposed, where the radiometer receive antenna (Archimedean spiral) is located on the front (skin) surface of the water bolus and the heating antenna (Dual-Concentric Conductor aperture) is placed on the bolus back surface. The motivation is to achieve homogeneous tissue heating simultaneously with non-invasive thermography of the target tissue under the applicator. This paper addresses the feasibility of predicting one-dimensional depth temperature profiles from multi-band brightness temperatures. The performance is investigated statistically by a Monte Carlo technique on both simulated and real heated-phantom data using up to six radiometric bands. Analysis of measured data shows that during the transient heating period in a solid lossy phantom, the inversion technique exhibits a precision (2sigmaT) and skewness (bias) of estimated compared to actual temperature profiles of better than +/-0.38 degrees C and +/-0.55 degrees C, respectively.

Algorithms↗

Feasibility and patient tolerance of a novel transrectal ultrasound hyperthermia system for treatment of prostate cancer.

This report describes patient tolerance and toxicity of a transrectal ultrasound hyperthermia system used with external beam radiation therapy in treatment of locally advanced prostate cancer. Nine patients with clinical T2B-T3B (4th edition AJCC criteria) disease received external beam radiation therapy, with two hyperthermia treatments scheduled at least 1 week apart during the first 4 weeks of radiation. Five patients also received hormonal therapy. Interstitial and anterior rectal wall thermometry were performed. Median temperature for each treatment (T50) was 40.8 degrees C and mean CEM T90 = 43 degrees C was 3.4 min. Rectal wall temperature was maintained at < or = 40 degrees C. Treatment duration was limited in three of 17 sessions due to positional discomfort which was alleviated with light IV sedation and use of a 'New Life' mattress (Comfortex, Inc. Winoba, MN, USA). Acute toxicity was limited to NCI common toxicity criteria grade 1 and no excess toxicity was noted with full course radiation therapy +/- hormonal therapy. These findings are consistent with those reported in a previous phase I trial assessing this device. Given the favourable toxicity profile demonstrated to date, modification of treatment parameters for this ongoing phase II study have been instituted that should further the efficacy of transrectal ultrasound hyperthermia for treatment of prostate cancer.

Aged↗

Temperature data and specific absorption rates in pelvic tumours: predictive factors and correlations.

The system BSD 2000 has been in clinical use for regional hyperthermia for more than 10 years. Several technical details of this hyperthermia system, as well as the results of clinical studies employing this system have been investigated. The intention of this paper is to investigate the correlation between technical efficiency or feasibility of hyperthermia with the BSD 2000, in terms of power densities and temperatures depending upon parameters such as tumour histology, tumour location, patient age, patient sex, and patient cross section. The possible conclusions of predictive factors derived from the above correlations were closely scrutinized. Data acquired from 772 treatment sessions of 190 patients with pelvic tumours, mainly sarcomas and carcinomas of the rectum, cervix, prostate and anus, have been evaluated. For every session, index temperatures T90 (temperature attained at 90% of tumour related measurement points), cumulative minutes for T90 > Tref, tumour related power density (SAR: specific absorption rate, in W/kg) and the effective perfusion Weff (in ml/100 g min) were calculated. Temperatures were measured either invasively or endoluminally. The statistics software SPSS was employed subsequently for univariate, as well as multivariate analyses. The results exhibit that index temperatures mainly depend on the power density SAR and the hyperthermia induced effective perfusion. The total power P (in 100 W) and, complementarily, the relative power density absolute value(SAR) (= SAR/P) seem to have lesser influence. Clear differences between the tumour entities were established regarding their index temperatures and temperature distributions. SAR, Weff and P were correlated with several anatomical, biological and clinical factors. Sessions rendering low index temperatures and SAR values also revealed decreased individual tolerance to the treatment. This clearly displays that power-induced side effects define the limits of the efficiency of regional hyperthermia. Equivalent relationships and correlations are derived from intratumoural and endoluminal thermometry. Individual limitations of regional hyperthermia caused by anatomical, biological and clinical factors are liable to be difficult to overcome with the rather restricted potentials of the BSD 2000 system to control the SAR distribution.

Analysis of Variance↗

Edge-element based finite element analysis of microwave hyperthermia treatments for superficial tumours on the chest wall.

Several three-dimensional hyperthermia treatment planning systems for deep regional hyperthermia have been successfully utilized for improving the performance of applicators such as the BSD Sigma 60. Treatment planning systems for superficial heating in contrast have been less utilized. This paper presents a study of the applicability of the finite element method that has been developed for modelling hyperthermia treatments of recurrent chest wall cancer using a patient geometry. The patient model was created by reconstructing the tissue geometry of a patient using a series of axial CT scans. Tetrahedral grids were generated from this geometry for use in finite element simulations of the SAR profile using edge-elements and in finite element simulations of the steady-state temperature profile using scalar elements. The predicted temperature profile was well correlated with thermometry readings taken after 30 min of heating during a hyperthermia treatment. The model predicted the presence of hot-spots in regions that were not monitored. Simulations also showed that the hot-spots can be manipulated by rotating the applicator by 90 degrees. This study demonstrates the ability of the model to provide detailed and accurate heating profiles in a patient specific model for superficial microwave hyperthermia of the chest wall.

Computer Simulation↗

Microwave thermal imaging: initial in vivo experience with a single heating zone.

The deployment of hyperthermia as a routine adjuvant to radiation or chemotherapy is limited largely by the inability to devise treatment plans which can be monitored through temperature distribution feedback during therapy. A non-invasive microwave tomographic thermal imaging system is currently being developed which has previously exhibited excellent correlation between the recovered electrical conductivity of a heated zone and its actual temperature change during phantom studies. To extend the validation of this approach in vivo, the imaging system has been re-configured for small animal experiments to operate within the bore of a CT scanner for anatomical and thermometry registration. A series of 5-7 day old pigs have been imaged during hyperthermia with a monopole antenna array submerged in a saline tank where a small plastic tube surgically inserted the length of the abdomen has been used to create a zone of heated saline at pre-selected temperatures. Tomographic microwave data over the frequency range of 300-1000 MHz of the pig abdomen in the plane perpendicular to the torso is collected at regular intervals after the tube saline temperatures have settled to the desired settings. Images are reconstructed over a range of operating frequencies. The tube location is clearly visible and the recovered saline conductivity varies linearly with the controlled temperature values. Difference images utilizing the baseline state prior to heating reinforces the linear relationship between temperature and imaged saline conductivity. Demonstration of in vivo temperature recovery and correlation with an independent monitoring device is an important milestone prior to clinical integration of this non-invasive imaging system with a thermal therapy device.

Abdomen↗

Feasibility of lung cancer hyperthermia using breathable perfluorochemical (PFC) liquids. Part I: Convective hyperthermia.

Clinical studies have shown that hyperthermia in combination with radiotherapy and/or chemotherapy may be effective in the treatment of advanced cancer. No method of lung hyperthermia, however, has been accepted as standard or superior. This investigation sought to demonstrate in animals the thermal and physiologic feasibility of lung hyperthermia induced using heated breathable perfluorochemical (PFC) liquids, a method termed liquid-filled lung convective hyperthermia (LCHT). The ability to use LCHT is rooted in the development of both PFC liquid ventilation, now in clinical development with the PFC perflubron (LiquiVent), and a PFC blood substitute also in late Phase III trials (Oxygent). As LCHT background, the PFC technologies and biology are first reviewed. The physical properties of a variety of PFCs were evaluated for LCHT and it was concluded that more than one liquid is suitable based on such properties. Using total liquid ventilation type devices, LCHT was shown to deliver successfully localized (lobar) lung heating in sheep, and bilateral whole lung heating and whole-body hyperthermia in rabbits, cats and lambs. During LCHT, lung parenchymal temperatures were uniform (<1 degree C) across heated regions. In addition, based on patterns relating lung tissue temperatures to inspiratory and expiratory PFC liquid temperatures in the endotracheal tube, LCHT may minimize invasive thermometry requirements in the lung. Based on acute experiments, it was concluded that LCHT appears feasible and may simplify lung hyperthermia. It was recommended that potentially synergistic combinations of LCHT with other whole-body hyperthermia or local heating modalities, and with chemotherapeutic lung drug delivery, also be explored in the future.

Animals↗

Effect of 8-MHz radiofrequency-capacitive regional hyperthermia with strong superficial cooling for unresectable or recurrent colorectal cancer.

A well-known disadvantage of a radiofrequency-capacitive device for deep-seated tumours is preferential heating of the subcutaneous fat tissue. The authors previously developed the hyperthermia with their own external cooling unit and achieved strong superficial cooling, and reported its usefulness for the reduction of the preferential heating. The purpose of the present study was to evaluate the effect of hyperthermia with strong superficial cooling on the treatment results for unresectable or recurrent colorectal cancers. From 1986 to 2002, 44 patients with primary unresectable or locally recurrent colorectal cancer treated with thermoradiotherapy were analysed retrospectively. The patients with obesity as a subcutaneous fat thickness more than 3 cm, a high age or other serious complications did not undergo therapy. The results were compared between 17 cases with strong superficial cooling treated after 1997 (Group A) and 27 cases without strong superficial cooling treated before 1996 (Group B). Significant differences in thermometry data of T(max), T(ave) and T(min) were noted between Groups A (45.3, 44.4 and 43.6 degrees C, respectively) and B (42.9, 42.0 and 41.1 degrees C, respectively) (p<0.01). Complete response plus partial response rates were better for Group A than for Group B (59 versus 26%, p = 0.05). Multivariate analysis by logistic regression to evaluate the effects of certain factors on complete response plus partial response was strongly correlated with strong superficial cooling (p<0.05). The median survival times for overall survival were 24.3 months for Group A and 17.1 months for Group B (p<0.05). Eight-megahertz radiofrequency-capacitive regional hyperthermia with strong superficial cooling is potentially useful for improving treatment results in unresectable or recurrent colorectal cancers.

Aged↗

MRI guided and monitored focused ultrasound thermal ablation methods: a review of progress.

This paper reviews the current status in using magnetic resonance imaging (MRI) to guide and monitor thermal coagulation of tumours using focused ultrasound. The patient treatment procedure with a second generation phased array system will be described. Several clinical trials have found that patient treatments are feasible and that MRI thermometry allows noninvasive monitoring of clinical treatments. Overall, this emerging modality holds significant potential for non-invasive tumour treatment of both benign and malignant tumours.

Humans↗

Development of a phantom compatible for MRI and hyperthermia using carrageenan gel-relationship between T1 and T2 values and NaCl concentration.

The authors developed a phantom, designated as the CAGN phantom, compatible for MRI and hyperthermia that is useful in the fundamental studies of non-invasive MR thermometry. The ingredients of this phantom are carrageenan, GdCl3 as a T1 modifier, agarose as a T2 modifier, NaCl as a conductivity modifier, NaN3 as an antiseptic and distilled water. Another phantom that was developed, the CAG phantom, has relaxation times that are adjustable to those of any human tissue. To use this phantom for electromagnetic heating, NaCl was added to change the conductivity of the phantom and clarified the relationship between the conductivity and NaCl concentration. This study examined the relationship between relaxation times and NaCl concentration of the CAGN phantom. The results showed that both T1 and T2 values were affected by NaCl and the experimental results led to the empirical formulae expressing the relationship between the relaxation rates (1/T1, 1/T2) and the concentrations of GdCl3, agarose and NaCl. The appropriate concentrations of T1 and T2 modifiers were calculated from these empirical formulae when making a specified phantom that has the required relaxation times and NaCl concentration.

Algorithms↗

Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid system.

INTRODUCTION: Non-invasive thermometry (NIT) is a valuable and probably indispensable tool for further development of radiofrequency (RF) hyperthermia. A hybridization of an MRI scanner with a hyperthermia system is necessary for a real-time NIT. The selection of the best thermographic method is difficult, because many parameters and attributes have to be considered. METHODS: In the hybrid system (Siemens Symphony/BSD-2000-3D) the standard methods for NIT were tested such as T1, diffusion (ADC: apparent diffusion coefficient) and proton-resonance-frequency shift (PFS) method. A series of three-dimensional datasets was acquired with different gradient-echo sequences, diffusion-weighted EPI spin-echo sequences and calculated MR-temperatures in the software platform AMIRA-HyperPlan. In particular for the PFS-method, corrective methods were developed and tested with respect to drift and other disturbances. Experiments were performed in phantoms and the results compared with direct temperature measurements. Then the procedures were transferred to clinical applications in patients with larger tumours of the lower extremity or the pelvis. RESULTS: Heating experiments and MR-thermography in a homogeneous cylindrical phantom give an excellent survey over the potentials of the methods. Under clinical conditions all these methods have difficulties due to motion, physiological changes, inhomogeneous composition and susceptibility variations in human tissues. The PFS-method is most stable in patients yielding reasonable MR temperature distributions and time curves for pelvic and lower extremity tumours over realistic treatment times of 60-90 min. Pooled data exist for rectal tumour recurrencies and soft tissue sarcomas. The fat tissue can be used for drift correction in these patients. T1 and diffusion-dependent methods appear less suitable for these patients. The standard methods have different sensitivities with respect to the various error sources. The advantages and pitfalls of every method are discussed with respect to the literature and illustrated by the phantom and patient measurements. CONCLUSIONS: MR-controlled RF hyperthermia in a hybrid system is well established in phantoms and already feasible for patients in the pelvic and lower extremity region. Under optimal conditions the temperature accuracy might be in the range of 0.5 degrees C. However a variety of developments, especially sequences and post-processing modules, are still required for the clinical routine.

Humans↗

Localized versus regional hyperthermia: comparison of xenotransplants treated with a small animal ultrasound system and waterbath limb immersion.

The response of xenotransplants were compared with waterbath immersion vs focal ultrasound (US) hyperthermia using tumour growth delay, immunhistochemistry and histopathology assays. Waterbath hyperthermia was performed by limb immersion. Precautions were taken to minimize total body heating by surrounding the mouse with plastic insulators. Thermometry was performed with clinical-grade, 20-gauge needle thermocouples and monitored with a Labthermics unit. Significant differences in cytotoxicity between ultrasound and waterbath treatment of tumors at 43 degrees C were observed as determined by TUNNEL assay. Conversely, contralateral (non-treated) tumours in animals treated with similar temperature demonstrated no significant differences between modalities. Western blot analysis revealed increased hsp70 induction at 43 degrees C in waterbath vs focal ultrasound hyperthermia. Comparison of tumour growth delay between tumours heated with waterbath vs ultrasound at 43 degrees C but not at 41 degrees C revealed significant differences. This is the first study comparing localized vs regional hyperthermia using the small animal ultrasound system (SAHUS) delivery system. Consistent ultrasound hyperthermia can be achieved throughout a xenotransplant. At equivalent temperature of 43 degrees C for 60?min, waterbath hyperthermia demonstrated greater local response vs ultrasound hyperthermia.

Animals↗

On estimation of the temperature maximum in intraluminal or intracavitary hyperthermia.

During intraluminal or intracavitary hyperthermia treatments, limited non-invasive temperature information is available, which may result in sub-optimal treatment control. This article describes a method for estimating temperature maximums and their corresponding locations in tissue heated by a cylindrical applicator with an incorporated cooling system, assuming a hollow cylinder of homogeneous tissue. The main purpose of this study is intraluminal heating of tumours at the oesophagus, but the principle described is generally applicable for cylindrical applicators. When assuming no perfusion and only radial heat flow in the heated tissue, an analytical expression for the temperature profile can be derived such that the complete profile can be reconstructed from the inner wall temperature only. For situations with perfusion, finite difference simulations have been performed and the resulting simulated inner wall temperature was put into the analytical expression to obtain an estimation for the maximum temperature and the corresponding location. This way, an estimation method was developed which does not require a priori knowledge of the perfusion rate or invasive thermometry. For volumetric perfusion rates in the clinically relevant range of 0-10 kg m-3 s-1, the deviations between simulated and estimated temperature maximums were less than 10% and the difference in location was typically a few tenths of a millimetre. These deviations are small enough for treatment control purposes.

Humans↗