Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Analysis of nucleotide sugars from cell lysates by ion-pair solid-phase extraction and reversed-phase high-performance liquid chromatography.

Analysis of nucleotide sugar metabolism is essential in studying glycosylation in cells. Here we describe practical methods for both extraction of nucleotide sugars from cell lysates and for their analytical separation. Solid-phase extraction cartridges containing graphitized carbon can be used for the purification of nucleotide sugars by using triethylammonium acetate buffer as a ion-pairing reagent for decreasing retention. After that they are separated by high-performance liquid chromatography using a C18 reversed-phase column and the same ion-pairing reagent for increasing retention. These new sample preparation and analysis methods enable good separation of structurally similar sugar nucleotides, compatibility with rapid evaporative concentration, and possibility to automation. Monitoring the production of GDP-deoxyhexoses in genetically engineered yeast and native bacterial cells are described here as specific applications.

Adsorption↗

Development of multiclass methods for drug residues in eggs: hydrophilic solid-phase extraction cleanup and liquid chromatography/tandem mass spectrometry analysis of tetracycline, fluoroquinolone, sulfonamide, and beta-lactam residues.

A method was developed for detection of a variety of polar drug residues in eggs via liquid chromatography/tandem mass spectrometry (LC/MS/MS) with electrospray ionization (ESI). A total of twenty-nine target analytes from four drug classes-sulfonamides, tetracyclines, fluoroquinolones, and beta-lactams-were extracted from eggs using a hydrophilic-lipophilic balance polymer solid-phase extraction (SPE) cartridge. The extraction technique was developed for use at a target concentration of 100 ng/mL (ppb), and it was applied to eggs containing incurred residues from dosed laying hens. The ESI source was tuned using a single, generic set of tuning parameters, and analytes were separated with a phenyl-bonded silica cartridge column using an LC gradient. In a related study, residues of beta-lactam drugs were not found by LC/MS/MS in eggs from hens dosed orally with beta-lactam drugs. LC/MS/MS performance was evaluated on two generations of ion trap mass spectrometers, and key operational parameters were identified for each instrument. The ion trap acquisition methods could be set up for screening (a single product ion) or confirmation (multiple product ions). The lower limit of detection for screening purposes was 10-50 ppb (sulfonamides), 10-20 ppb (fluoroquinolones), and 10-50 ppb (tetracyclines), depending on the drug, instrument, and acquisition method. Development of this method demonstrates the feasibility of generic SPE, LC, and MS conditions for multiclass LC/MS residue screening.

Animals↗

Comprehensive screening of anabolic steroids, corticosteroids, and acidic drugs in horse urine by solid-phase extraction and liquid chromatography-mass spectrometry.

This paper reports two highly efficient liquid chromatography-mass spectrometry (LC-MS) methods for the screening of anabolic steroids, corticosteroids, and acidic drugs for the purpose of doping control in equine sports. Sample extraction was performed using a mixed-mode C8-SCX solid-phase extraction (SPE) cartridge. The first eluted fraction (acidic/neutral fraction) was base-washed and the resulting organic extract was used for the screening of anabolic steroids and corticosteroids by LC-MS using multiple reaction monitoring (MRM) in the positive electrospray ionisation (ESI) mode. The remaining aqueous extract was re-adjusted to pH 6 and acidic drugs were recovered by liquid/liquid extraction. Detection was again achieved using LC-MRM but in the negative ESI mode. A total of 40 anabolic steroids and corticosteroids, and over 50 acidic drugs, including some cyclooxygenase-2 (COX-2) inhibitors, oxicams, anti-diabetics, sedatives, diuretics and Delta(9)-tetrahydro-11-norcannabinol-9-carboxylic acid, could be covered by the two LC-MS methods. Both methods utilized a high efficiency reversed-phase column (3.3 cm L x 2.1 mm I.D. with 3 microm particles) coupled with a fast-scanning triple-quadrupole mass spectrometer to achieve fast turnaround times. The overall turnaround times for both methods were 10 min, inclusive of post-run and equilibration times.

Adrenal Cortex Hormones↗

Development of a mass spectrometry method for the determination of a melanoma biomarker, 5-S-cysteinyldopa, in human plasma using solid phase extraction for sample clean-up.

5-S-cysteinyldopa is a well-known pigment intermediate and analysis of its plasma concentration is interesting for the early diagnosis, as well as for evaluation of treatment and follow-up of malignant melanoma. A determination method of 5-SCD in human plasma was developed using solid phase extraction (SPE) on disposable cartridges and liquid chromatography electrospray mass spectrometry (LC-ESI-MS-MS). Compound's sensitivity to light and oxidation requires the addition of anti-oxidative agents (AO), to work in acidic media at 4 degrees C and to avoid light exposure of samples since blood collection. Different solid phases involving covalent binding to phenylboronic groups or dual retention mechanisms were evaluated and extraction cartridges containing both hydrophobic and strong cation exchange functionalities were finally selected. The LC separation of 5-SCD from endogenous catecholamines was achieved by gradient elution on a C18 stationary phase. 5-SCD was detected by multiple reaction monitoring (MRM) performed on ES(+) generated ions. Finally, the method was prevalidated in the lower ng/ml range. Good results with respect to accuracy, trueness and precision were obtained.

Biomarkers, Tumor↗

Selective solid-phase extraction of tebuconazole in biological and environmental samples using molecularly imprinted polymers.

Molecularly imprinted polymers (MIPs) were prepared by precipitation polymerization using tebuconazole (TBZ) as a template. Frontal chromatography and selectivity experiments were used to determine the binding capabilities and binding specificities of different MIPs. The polymer that had the highest binding selectivity and capability was used as the solid-phase extraction (SPE) sorbent for the direct extraction of TBZ from different biological and environmental samples (cabbage, pannage, shrimp, orange juice and tap water). The extraction protocol was optimized and the optimum conditions were: conditioning with 5 mL methanol:acetic acid (9:1), 5 mL methanol and 5 mL water respectively, loading with 5 mL aqueous samples, washing with 1.2 mL acetonitrile (ACN):phosphate buffer (5:5, pH3), and eluting with 3 mL methanol. The MIPs were able to selectively recognize, effectively trap and preconcentrate TBZ over a concentration range of 0.5-15 micromol/L. The intraday and interday RSDs were less than 9.7% and 8.6%, respectively. The limit of quantification was 0.1 micromol/L. Under optimum conditions, the MISPE recoveries of spiked cabbage, pannage, shrimp, orange juice and tap water were 62.3%, 75.8%, 71.6%, 89% and 93.9%, respectively. MISPE gave better HPLC separation efficiencies and higher recoveries than C18 SPE and strong cation exchange (SCX) SPE.

Acetic Acid↗

Analysis of neutral and basic pharmaceuticals in sewage treatment plants and in recipient rivers using solid phase extraction and liquid chromatography-tandem mass spectrometry detection.

Analytical method was developed which allowed for the detection of four beta blockers (acebutolol, atenolol, metoprolol and sotalol), an antiepileptic drug (carbamazepine) and three fluoroquinolone antibiotics (ciprofloxacin, ofloxacin and norfloxacin) with a single pre-treatment and chromatographic method. The method included an isolation and concentration procedure using solid phase extraction, a separation step using high performance liquid chromatography and a detection procedure applying triple quadrupole mass spectrometry, which was working in the multiple reaction monitoring mode. The method was validated for ground, surface and sewage influent and effluent waters. Due to ion suppression in the electrospray source, the signals monitored for the analytes were less intense in sewage waters compared to ground and surface waters. The limits of quantification were as low as 1 ng L(-1) in ground water and 3.5 ng L(-1) in sewage influent. The method was successfully applied to the determination of the target compounds in raw and treated sewages of three treatment plants in Finland and in their recipient rivers. The results showed that many of the studied compounds pose a moderate to high persistency in sewage treatment as well as in the recipient rivers. The analytical protocol presented may be used for more in-depth studies on the occurrence and fate of these commonly used pharmaceuticals in the sewage treatment plants and in the aquatic environment.

Chromatography, Liquid↗

A high performance liquid chromatographic method for the determination of albuterol enantiomers in human serum using solid phase extraction and chemical derivatization.

A high performance liquid chromatographic method was developed for the simultaneous assay of R(-)- and S(+)-albuterol in human serum. The assay involves solid phase extraction as a sample clean-up step and derivatization of racemic albuterol to its diastereomeric thioureas with 2,3,4,6-tetra-O-acetyl-alpha-D-glucopyranosyl isothiocyanate. Chromatographic separation was accomplished under isocratic conditions using an octadecylsilane column and a mobile phase consisting of 29:71 acetonitrile:distilled water containing 0.1% triethylamine, pH 4.0 (adjusted with concentrated phosphoric acid) at a flow rate of 0.8 mL/min. The diastereomers were detected using a fluorescence detector set at 223 nm excitation and no emission filter. Racemic bamethane was used as internal standard. Drug to internal standard peak-height ratios were linear over a 2-20 ng/mL range for each enantiomer. The limit of detection of each analyte was 1.0 ng/mL (S/N = 3).

Albuterol↗

On-line solid-phase extraction with automated cartridge exchange for liquid chromatographic determination of lipophilic antioxidants in plasma.

A fully automated liquid chromatographic method is described based on a Prospekt solid-phase extraction unit for the analysis of lipophilic indenoindolic antioxidants in plasma. Plasma samples, mixed with internal standard, were injected onto C8-cartridges. After washing, the samples were eluted and transferred to a C8-analytical column, where separation was performed. The eluent was monitored by electrochemical detection. Owing to the nature of the drugs investigated care had to be taken to avoid adsorption losses in vials and capillaries. The method, which was found to give excellent recoveries (100.9%, n = 8) and repeatability (R.S.D. +/- 1.7%), is time-saving compared to a previously used assay with sample work-up by liquid-liquid extraction.

Adsorption↗

Semi-automated solid-phase extraction procedure for drug screening in biological fluids using the ASPEC system in combination with Clean Screen DAU columns.

The use of a semi-automated solid-phase extraction system (ASPEC) for the screening of drugs in plasma and urine on a single mixed-mode column (Clean Screen DAU) is described. The processes of column preconditioning, sample application, column wash, pH adjustment and elution of the drugs were accomplished by the ASPEC. After off-line evaporation, the residues were injected into a wide-bore capillary gas chromatograph. The recoveries of the tested drugs were in the range of 73-96%, with relative standard deviations less than 5% at a concentration level of 2 micrograms/ml.

Animals↗

beta-Cyclodextrin-bonded silica particles as the solid-phase extraction medium for the determination of phenol compounds in water samples followed by gas chromatography with flame ionization and mass spectrometry detection.

A new absorbent for solid-phase extraction (SPE) was prepared by a beta-cyclodextrin bonded silica stationary phase (CDS) has been applied to determine the concentrations of phenol compounds in water samples. SPE of selected phenolic compounds from aqueous samples were performed using 250 mg CDS. The determination was subsequently carried out by gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). Compared with available SPE, the CDS showed high sensitivity and fast velocity of mass transfer for phenolic compound because of its porous structure of beta-cyclodextrin. The relative standard deviation (RSD) for river water sample spiked with phenolic compounds at sub-ppb level was lower than 10% and limit of detection (LOD) for these compounds were between 10 and 100 ng l(-1).

Gas Chromatography-Mass Spectrometry↗

Development and validation of an automated solid phase extraction and liquid chromatographic method for the determination of piperaquine in urine.

A sensitive and specific bioanalytical method for determination of piperaquine in urine by automated solid-phase extraction (SPE) and liquid chromatography (LC) has been developed and validated. Buffered urine samples (containing internal standard) were loaded onto mixed phase (cation-exchange and octylsilica) SPE columns using an ASPEC XL SPE robot. Chromatographic separation was achieved on a Chromolith Performance RP-18e (100 mm x 4.6 mm I.D.) LC column with phosphate buffer (pH 2.5; 0.1 mol/L)-acetonitrile (92:8, v/v). Piperaquine was analysed at a flow rate of 3 mL/min with UV detection at 347 nm. A linear regression model on log-log transformed data was used for quantification. Within-day precision for piperaquine was 1.3% at 5000 ng/mL and 6.6% at 50 ng/mL. Between-day precision for piperaquine was 3.7% at 5000 ng/mL and 7.2% at 50 ng/mL. Total-assay precision for piperaquine over 4 days using five replicates each day (n = 20) was 4.0%, 5.2% and 9.8% at 5000, 500 and 50 ng/mL, respectively. The lower limit of quantification (LLOQ) was set to 3 ng/mL using 1 mL of urine, which could be lowered to 0.33 ng/mL when using 9 mL of urine and an increased injection volume.

Animals↗

Analysis of aromatic sulfonates in water by solid-phase extraction and capillary electrophoresis.

The separation of 14 different aromatic sulfonates of environmental concern by capillary (zone) electrophoresis (CZE) is presented. A new off-line solid-phase extraction (SPE) enrichment procedure, that is compatible with CE analysis, was developed, using the styrene-divinylbenzene adsorbent LiChrolut EN. The combined method of SPE and CE allows the determination of aromatic sulfonates in water samples in the low microgram/l range. Separations are performed with a simple sodium borate buffer at pH 9.3. Analytes are detected by UV absorbance and fluorescence emission with a Xe-lamp excitation source, and both principles are compared. The recoveries for most of the sulfonates are > 70% for the extraction from spiked tap and river water. The average method precision is < 20% for replicate analyses. Very hydrophilic sulfonates cannot be extracted by this method. The detection limit of the combined method of SPE enrichment and CE analysis is approximately 0.1 microgram/l for 200-ml water samples. The performance of the method was checked with the analysis of river and contaminated seepage water.

Calibration↗

Semi-automated 96-well solid-phase extraction and gas chromatography-negative chemical ionization tandem mass spectrometry for the trace analysis of fluprostenol in rat plasma.

Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%.

Animals↗

Resolution and quantitation of pentazocine enantiomers in human serum by reversed-phase high-performance liquid chromatography using sulfated beta-cyclodextrin as chiral mobile phase additive and solid-phase extraction.

A sensitive and stereospecific HPLC method was developed for the analysis of (-)- and (+)-pentazocine in human serum. The assay involves the use of a phenyl solid-phase extraction column for serum sample clean-up prior to HPLC analysis. Chromatographic resolution of the pentazocine enantiomers was performed on a octadecylsilane column with sulfated-beta-cyclodextrin (S-beta-CD) as the chiral mobile phase additive. The composition of the mobile phase was aqueous 10 mM potassium dihydrogenphosphate buffer pH 5.8 (adjusted with phosphoric acid)-absolute ethanol (80:20, v/v) containing 10 mM S-beta-CD at a flow-rate of 0.7 ml/min. Recoveries of (-)- and (+)-pentazocine were in the range of 91-93%. Linear calibration curves were obtained in the 20-400 ng/ml range for each enantiomer in serum. The detection limit based on S/N=3 was 15 ng/ml for each pentazocine enantiomer in serum with UV detection at 220 nm. The limit of quantitation for each enantiomer was 20 ng/ml. Precision calculated as R.S.D. and accuracy calculated as error were in the range 0.9-7.0% and 1.2-6.2%, respectively, for the (-)-enantiomer and 0.8- 7.6% and 1.2-4.6%, respectively, for the (+)-enantiomer (n=3).

Analgesics, Opioid↗

Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol.

The adsorptive potential of multiwalled carbon nanotubes (MWNTs) for solid-phase extraction of bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol was investigated for the first time. The three analytes are quantitatively adsorbed on a MWNTs-packed cartridge, then the analytes retained on the cartridge are quantitatively desorbed with suitable amounts of methanol. Finally, the analytes in the methanol eluate are determined by high performance liquid chromatography-fluorometric detection. Parameters influencing the extraction efficiency, such as volume of the sample solutions, pH of the sample, and the eluent volume, were examined. Comparative studies showed that MWNTs were superior to C18 for the extraction of the more polar analyte bisphenol A and at least as effective as C18 for the extraction of 4-n-nonylphenol and 4-tert-octylphenol. Compared to XAD-2 copolymer, MWNTs exhibited a better property for the extraction of all three analytes. The developed method has been applied to determine bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol in several environmental water samples. The accuracy of the proposed method was tested by recovery measurements on spiked samples, and good recovery results (89.8-104.2%) were obtained. Detection limits of 0.083, 0.024, and 0.018 ng mL(-1) for bisphenol A, 4-n-nonylphenol, and 4-tert-octylphenol, respectively, were achieved under the optimized conditions.

Adsorption↗

Liquid chromatographic determination of natural and synthetic colorants in lyophilized foods using an automatic solid-phase extraction system.

Five synthetic and five natural colorants were determined in lyophilized dairy products and fatty foods using an automatic method based on lixiviation and a solid-phase extraction process that includes cotton and RP-C(18) columns for the sequential retention of synthetic colorants and natural colorants, respectively. The lyophilization of the sample coupled with the separation procedure provides clean extracts despite the complexity of the matrices studied. In addition, the lyophilization process preserves the sample for at least 2 months without changes in the concentrations of the colorants. Identification and determination of synthetic and natural colorants were carried out using a liquid chromatograph equipped with a diode array detector. The detection limits achieved for all of the colorants (0.03-75 microg/g of lyophilized sample) allowed their determination within the limits established by the European Union, with good precision (approximately 4.5%). In addition, colorants spiked to different foods provided average recoveries (spiked at three concentration levels in four types of dairy samples and in three types of fatty foods) near 94 +/- 4%.

Autoanalysis↗

Separation and identification of phenolic compounds in olive oil by coupling high-performance liquid chromatography with postcolumn solid-phase extraction to nuclear magnetic resonance spectroscopy (LC-SPE-NMR).

This study reports the first application of the hyphenated LC-SPE-NMR technique using postcolumn solid-phase extraction to the direct analysis of phenolic compounds in the polar part of olive oil. Apart from the identification and structure elucidation of simple phenols (hydroxytyrosol, tyrosol, vanillic acid, vanillin, p-coumaric acid, hydroxytyrosol, and tyrosol acetates), lignans (pinoresinol and 1-acetoxypinoresinol), flavonoids (apigenin and luteolin), and a large number of secoiridoid derivatives, this technique enables the identification of several new phenolic components, which had not been reported previously as constituents in the polar part of olive oil.

Chromatography, High Pressure Liquid↗

Determination of ivermectin residues in swine tissues--an improved clean-up procedure using solid-phase extraction.

A rapid and sensitive HPLC method has been developed for the determination of ivermectin in swine tissues. The clean-up procedure is based on solid-phase extraction on a Bond-Elut C8 cartridge. The average recovery from spiked swine muscle tissue was 87% in the concentration range 2-20 micrograms/kg. The method has a limit of detection of 0.5-1 microgram/kg. A survey of the levels in muscle tissues from 35 sanitary slaughtered sows was made. Five samples were found to contain ivermectin at concentrations between 3.4 and 27.6 micrograms/kg. A good correlation (r = 0.9696) was found between these results and those obtained using another established method.

Animals↗