Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulse”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Subthreshold test pulses versus low energy shock delivery to estimate high energy lead impedance in implanted cardioverter defibrillator patients.

The high energy lead impedance is valuable for detecting lead failure in ICDs, but until recently shock delivery was necessary for high energy impedance measurement. This study compared the use of subthreshold test pulses and low energy test shocks to estimate the high energy impedance. Immediately after implantation of Ventak Prizm ICDs in 29 patients, the lead impedance was measured with five subthreshold (0.4 microJ) test pulses, 5 low energy (1.1 J) shocks, and two to three high energy (16 +/- 4.5 J) shocks. The mean impedances measured using high energy shocks, low energy shocks, and subthreshold pulses were 42.0 +/- 7.3 omega, 46.5 +/- 8.1 omega, and 42.4 +/- 7.1 omega, respectively. The impedances measured using high and low energy shocks differed significantly (P < 0.0001), while those obtained by high energy shocks and low energy pulses did not (P = 0.63). According to the Pearson correlation coefficient, the impedance measurements with subthreshold pulses and low energy shocks were both closely correlated (P < 0.0001) with impedance values determined with high energy shocks. However, while the impedance values tended to be higher when measured with low energy shocks, the concordance correlation coefficient (c) was higher for subthreshold test pulse versus high energy shock (c = 0.92) than for low versus high energy shock (c = 0.73). Furthermore, the intraindividual variability of impedance measurements was lower with subthreshold pulse measurements than with low energy shocks. Compared with low energy shocks, impedance measurement with subthreshold pulses has higher reproducibility and a higher correlation with the impedance obtained by high energy shock delivery. Safe and painless high energy impedance estimation with subthreshold pulses might, therefore, help to detect ICD lead failure during routine follow-up.

Aged↗

Laser hair removal: a review and report on the use of the long-pulsed alexandrite laser for hair reduction of the upper lip, leg, back, and bikini region.

BACKGROUND: The mechanism and permanence of laser-assisted hair removal remains a formidable task in the medical community. OBJECTIVE: The purpose of this study was to determine the safety and long-term efficacy of the long-pulsed or normal mode alexandrite infrared laser for hair depilation. METHODS: Beginning in October 1996, a total of 31 anatomic sites on 22 patients ranging in age from 25 to 59 years (mean 42 years) were evaluated to assess hair removal. Treatment sites included 17 upper lips, 9 legs, 2 backs, and 3 bikini regions. Eligible patients were of Fitzpatrick skin types I-III. Patients were treated using the long-pulsed alexandrite infrared laser at 755 nm, single-pulse technique, 10 mm spot size, 10% overlap, pulse durations of 5, 10, and 20 msec, and a fluence of 20 J/cm2. Subjective patient improvement and objective, blinded graded improvement was assessed at 1, 2, 3, and 6 months. RESULTS: Objective blinded grading at 6 months revealed that hair reduction varied both with the pulse duration and anatomic location. Maximum reductions observed were 40%, 56%, 50%, and 15% for the lip, leg, back, and bikini areas, respectively. Upper lip hair reduction increased from 40% to 54% at 6 months when a second treatment was performed 8 weeks after the initial treatment. CONCLUSION: The long-pulsed alexandrite laser is safe and effective in reducing hair growth. Treatment efficacy varies with the anatomic location, pulse duration, and number of treatments. A single-pulse technique utilizing a 10 msec pulse duration at 20 J/cm2 produced the greatest hair reduction. No permanent adverse effects occurred on skin types I-III at the parameters tested.

Adult↗

Terbinafine pulse therapy is effective in tinea capitis.

Terbinafine pulse therapy was found to be effective and safe in the treatment of tinea capitis in an open study of 13 children (age range 3-13 years, mean 6.4 years, 7 males, 6 females, Tricohphyton tonsurans 7 patients, T. violaceum 6 patients). Each pulse of active therapy lasted 1 week with a 2 weeks off period between the first two pulses and a 3 weeks off period between the second and third pulses of treatment. The dosage of terbinafine was determined by the weight of the child: >40 kg, 250 mg/day, 20 to 40 kg, 125 mg/day and <20 kg, 62.5 mg/day. Twelve (92.3%) of 13 children achieved complete clinical and mycological cure when evaluated 12 weeks after starting therapy with the number of pulses for complete (clinical and mycological) cure being one pulse (two patients with mild severity of tinea capitis), two pulses (four patients with mild disease) and three pulses (mild disease: two patients, moderate disease: two patients, and severe disease: three patients). One child with moderate severity disease failed to clear after three pulses of terbinafine. There were no adverse effects observed in any of the 13 patients during the course of therapy. All the parents found it easy to administer therapy and the compliance was high.

Adolescent↗

The accuracy of pulse oximetry in the emergency department.

The objective of this retrospective study was to identify factors affecting the accuracy of pulse oximetry in the ED. Over a 3-year period, 664 consecutive emergency department (ED) patients had simultaneous arterial blood gas (ABG) and pulse oximeter readings taken. Pulse oximeter saturations (SpO2) were compared with ABG CO-oximeter saturations (SaO2) for accuracy. Multiple variables including age, sex, hemoglobin, bicarbonate, pH, and carboxyhemoglobin (COHb) were analyzed to see if they affected SpO2 accuracy. ROC curves were used to determine the best pulse oximeter threshold for detecting hypoxia. Using multivariate analysis, COHb was the only statistically significant factor affecting the accuracy of pulse oximetry. In patients with COHb <2%, SpO2 overestimated SaO2 by more than 4% in 8.4% of cases. In patients with COHb > or = 2%, SpO2 overestimated SaO2 by more than 4% in 35% of cases. The best pulse oximetry threshold for detecting hypoxia is 92%. At this threshold, if COHb is <2%, pulse oximetry has a sensitivity of 0.92 and specificity of 0.90. If COHb is > or =2%, sensitivity is 0.74 and specificity is 0.84. For patients likely to have a COHb < 2, pulse oximetry is an effective screening tool for detecting hypoxia. However, more caution must be exercised when using pulse oximetry in patients likely to have a COHb > or = 2%.

Blood Gas Analysis↗

Activation of in vivo- and in vitro-derived porcine oocytes by using multiple electrical pulses.

The current protocols used to activate pig nuclear transfer embryos are less efficient than those used for other species. To address this problem, the effect of multiple sets of electrical pulses on the parthenogenetic development of in vivo- and in vitro-derived porcine oocytes was examined. Each set of pulses consisted of two 1.5 kV cm(-1) DC pulses of 60 micros duration each, administered 1 s apart. For in vivo-derived oocytes, application of a second set of pulses 30 min after the first set increased the proportion of oocytes that developed to the blastocyst stage compared with a single treatment (51 v. 34%). Application of a third set of pulses 30 min after the second set reduced the rate of blastocyst formation compared with two sets of pulses. In contrast, the rate of blastocyst formation was greater with one set of pulses compared with two sets for in vitro matured oocytes (31 v. 16%). Additional sets of electrical pulses did not affect the number of cells in blastocysts obtained from either group of oocytes compared with a single treatment. In summary, the study demonstrates that the application of a second set of activating pulses 30 min after the first set is beneficial to in vivo-derived oocytes, but detrimental to in vitro matured oocytes, in terms of their ability to develop parthenogenetically to the blastocyst stage.

Animals↗

Mitochondrial calcium uptake from physiological-type pulses of calcium. A description of the rapid uptake mode.

A controversy in the field of bioenergetics has been whether mitochondria are capable of sequestering enough Ca2+ from cytosolic Ca2+ pulses to raise their intramitochondrial free Ca2+ level ([Ca2+]m). This is significant because an increase in [Ca2+]m has been linked to an increase in cellular metabolic rate through various mechanisms. To resolve this question, we exposed isolated liver mitochondria to physiological type pulses of Ca2+ produced using a pulse-generating system (Sparagna, G. C., Gunter, K. K., and Gunter, T. E. (1994) Anal. Biochem. 219, 96-103). We then measured the resulting mitochondrial Ca2+ uptake. The uniporter was previously thought to be the only specific Ca2+ uptake mechanism in mitochondria. Our studies have uncovered an additional uptake mechanism, the rapid mode of uptake or RaM, which functions at the beginning of each pulse and allows mitochondria to sequester a considerable amount of Ca2+ from short pulses. We have shown that the RaM is reset by decreasing the [Ca2+] between pulses for a very short time, making this uptake mode ideally suited for Ca2+ sequestration from Ca2+ pulse sequences. With rapid Ca2+ uptake occurring at the beginning of each pulse, liver mitochondria may be able to sequester sufficient Ca2+ from a short sequence of pulses to activate the cellular metabolic rate.

Animals↗

Therapy of murine tumors with tumor peptide-pulsed dendritic cells: dependence on T cells, B7 costimulation, and T helper cell 1-associated cytokines.

Antigen presentation by host dendritic cells (DC) is critical for the initiation of adaptive immune responses. We have previously demonstrated in immunogenic murine tumor models that bone marrow (BM)-derived DC pulsed ex vivo with synthetic tumor-associated peptides, naturally expressed by tumor cells, serve as effective antitumor vaccines, protecting animals against an otherwise lethal tumor challenge (Mayordomo, J.I., T. Zorina, W.J. Storkus, C. Celluzzi, L.D. Falo, C.J. Melief, T. Ildstad, W.M. Kast, A.B. DeLeo, and M.T. Lotze. 1995. Nature Med. 1:1297-1302). However, T cell-defined epitopes have not been identified for most human cancers. To explore the utility of this approach in the treatment of tumors expressing as yet uncharacterized epitopes, syngeneic granulocyte/macrophage colony-stimulating factor-stimulated and BM-derived DC, pulsed with unfractionated acid-eluted tumor peptides (Storkus, W.J., H.J. Zeh III, R.D. Salter, and M.T. Lotze. 1993. J. Immunother. 14:94-103) were used to treat mice bearing spontaneous, established tumors. The adoptive transfer of 5 x 10(5) tumor peptide-pulsed DC dramatically suppressed the growth of weakly immunogenic tumors in day 4 to day 8 established MCA205 (H-2b) and TS/A (H-2d) tumor models, when applied in three biweekly intravenous injections. Using the immunogenic C3 (H-2b) tumor model in B6 mice, tumor peptide-pulsed DC therapy resulted in the erradication of established d14 tumors and long-term survival in 100% of treated animals. The DC-driven antitumor immune response was primarily cell mediated since the transfer of spleen cells, but not sera, from immunized mice efficiently protected sublethally irradiated naive mice against a subsequent tumor challenge. Furthermore, depletion of either CD4+ or CD8+ T cells from tumor-bearing mice before therapy totally suppressed the therapeutic efficacy of DC pulsed with tumor-derived peptides. Costimulation of the host cell-mediated antitumor immunity was critical since inoculation of the chimeric fusion protein CTLA4-Ig virtually abrogated the therapeutic effects of peptide-pulsed DC in vivo. The analysis of the cytokine pattern in the draining lymph nodes and spleens of tumor-bearing mice immunized with DC pulsed with tumor-eluted peptides revealed a marked upregulation of interleukin (IL) 4 and interferon (IFN) gamma production, as compared with mice immunized with DC alone or DC pulsed with irrelevant peptides. DC-induced antitumor effects were completely blocked by coadministration of neutralizing monoclonal antibody directed against T helper cell 1-associated cytokines (such as IL-12, tumor necrosis factor alpha, IFN-gamma), and eventually, but not initially, blocked by anti-mIL-4 mAb. Based on these results, we believe that DC pulsed with acid-eluted peptides derived from autologous tumors represents a novel approach to the treatment of established, weakly immunogenic tumors, and serves as a basis for designing clinical trials in cancer patients.

Animals↗

The clinical application of non-invasive intracranial blood volume pulse wave monitoring.

An ultrasonic method was used to non-invasively measure intracranial blood volume (IBV) pulse waveforms. This technology has previously shown a strong association between invasively recorded ICP pulse waves and non-invasively recorded IBV pulse waves. The objective of the present study was to investigate the diagnostic value of non-invasively measured IBV pulse waves in the cases of different pathologies. A total of 75 patients were examined and these included cases of acute, chronic and stabilized hydrocephalus, spinal cord injury and terminal blood flow. These were compared to a control group of 53 healthy volunteers. The object of comparison was normalized and averaged IBV pulse waves. Pathological IBV pulse waveforms were compared with IBV pulse waveforms of the normal group using sub-wave values, the area under waveform curve and the Euclidean distance calculation. The non-invasively measured IBV pulse waveform is not significantly dependent on acoustic path, gender or age. A detectable change in IBV pulse waveform shape was observed in situations when disturbance in intracranial hydrodynamics was present, e.g. during hypoventilation tests, in cases of terminal blood flow and hydrocephaly, depicting the level of hydrocephalus activity and the patient's compensatory capabilities as well as the effect of treatment.

Adolescent↗

Effect of holmium:YAG laser pulse width on lithotripsy retropulsion in vitro.

BACKGROUND AND PURPOSE: The effect of laser pulse width on calculus retropulsion during ureteroscopic lithotripsy is poorly defined because of the limited availability of variable pulse-width lasers. We used an adjustable pulse-width Ho:YAG laser to test the effect of pulse width on in vitro phantom-stone retropulsion and fragmentation efficiency. METHODS AND MATERIALS: An Odyssey 30 Ho:YAG laser (Convergent Laser Technologies, Oakland, CA) with adjustable pulse width (350 or 700 microsec) was used to treat spherical 10-mm plaster calculi in a model ureter (N = 40) and calix (N = 16) utilizing 200- and 400-microm fibers (10 Hz, 1.0 J). Calculi were placed in a waterfilled clear polymer tube, and laser energy was applied continuously in near contact until the stone had moved 8 cm. The time (seconds) and energy (joules) needed to cause the stone to traverse this distance was recorded. Stones were also placed in a stainless-steel mesh calix model in which retropulsion was limited. Laser energy was applied for 5 minutes at each pulse width. A laser-energy meter (Molectron Detector Inc, Portland OR) was used to quantify fiber transmission efficiency after 1 minute of continuous lithotripsy for each fiber at each pulse width. RESULTS: Retropulsion was greater for stones treated at 350 microsec, indicated by a shorter time to traverse the model ureter. For the 200-microrm fiber at 350 microrsec, the average time was 11.5 seconds v 20.3 seconds at 700 microsec (P < 0.001). The average total energy delivered was 114.9 J at 350 microsec v 199.8 J at 700 microsec (P < 0.001). For the 400-microm fiber at 350 microsec, the average time was 5.8 seconds v 11.9 seconds at 700 microsec (P < 0.001). The average total energy was 57.1 J at 350 microsec v 127.3 J at 700 microsec (P < 0.001). In the caliceal model, at 350 and 700 microsec with the 200- and 400-microm fibers, mass loss was 34.9% and 33.4% (P = 0.8) and 14.6% and 21.6% (P = 0.04), respectively. The reduction in energy transmission at 350 microsec and 700 microsec with the 200- microm fiber after 60 seconds of continuous lasing was 8.82% v 9%, respectively (P = 0.95). For the 400-microm fiber, the transmission loss was 18.4% at 350 microsec v 4.4% at 700 microsec (P = 0.0002). CONCLUSION: When treating ureteral calculi, retropulsion can be reduced by using a longer pulse width without compromising fragmentation efficiency. For caliceal calculi, the longer pulse width in combination with a 400-microm fiber provides more effective stone fragmentation.

Aluminum↗

Super pulse CO2 laser for bracket bonding and debonding.

A super pulse and a normal pulse CO2 laser were used to carry out enamel etching and bracket debonding in vitro and in vivo. The shear bond strength of the orthodontic brackets attached to laser-etched and conventional chemically-etched extracted premolars was measured. The pulp cavity temperature was also measured using the same laser irradiation conditions as the shear test. Both super pulse and normal pulse CO2 laser etching resulted in a lower shear bond strength (super pulse: 6.9 +/- 3.4 kg, normal pulse: 9.7 +/- 5.2 kg) than that of chemical etching (15.3 +/- 2.8 kg). Furthermore, the super pulse CO2 laser was able to create debonding at 2 watts within a period of less than 4 seconds (2.9 +/- 0.9 seconds). The super pulse, when irradiating the ceramic brackets from above, during debonding showed a 1.4 degrees C temperature increase in the dental pulp at 2 watts and an increase of 2.1 degrees C at 3 watts. While etching, directly irradiating the enamel surface at 3 watts, the dental pulp showed a temperature increase of 3.5 degrees C. These temperature increases were within the physiologically acceptable limits of the pulp. These results indicate that, in orthodontic treatments, super pulse CO2 laser debonding is more useful than laser etching.

Acid Etching, Dental↗

The effects of selected stimulus waveforms on pulse and phase characteristics at sensory and motor thresholds.

BACKGROUND AND PURPOSE: The purposes of this investigation were to determine the effect of five commonly used voltage waveforms (four pulsed and one sinusoidal) on excitation of sensory and motor nerves and to characterize variables associated with reaching threshold. SUBJECTS: Eighteen healthy subjects were stimulated during one session via surface electrodes placed over the forearm and leg. METHODS: Stimulation amplitude was increased at a constant rate, and the threshold of sensory and motor excitation was determined. Measured variables included peak voltage, peak current, phase charge, and total pulse charge. RESULTS: Three-factorial, repeated-measures analysis of variance and Newman-Keuls tests revealed that phase charge varied the least during excitation induced by the five waveforms. Total pulse charge markedly increased when bursts of 10 symmetrical pulses, 25 symmetrical pulses, or amplitude-modulated waveforms were used. Monophasic and symmetrical biphasic waveforms required the least amount of total pulse charge. All measurements were higher during motor threshold than during sensory threshold, and the measurements were higher in the leg than in the forearm. CONCLUSION AND DISCUSSION: The authors concluded that all five studied waveforms were effective at threshold excitation of peripheral sensory and motor nerves. Of the five waveforms, the symmetrical biphasic waveform, having a low total pulse charge, may be the preferred waveform, and the 25 symmetrical pulses and amplitude-modulated waveforms may be considered the least preferred due to high total pulse charge.

Adult↗

Response of Douglas-fir seedlings to a brief pulse of 15N-labeled nutrients.

The temporal distribution of soil nutrients is heterogeneous, and thus the uptake, storage and later remobilization of brief nutrient pulses may be critical for growth in nutrient-limited habitats. We investigated the response of 2-year-old Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco) seedlings receiving a low nutrient supply to a 15-day nutrient pulse (containing 250 ppm nitrogen (N) as 10 atom % 15NH4 15NO3). The nutrient pulse was imposed in late July, toward the end of the seedlings' third growing season, and subsequent changes in dry mass and N content over the following 3 months were determined from destructive harvests. We tested three hypotheses: (1) N from the nutrient pulse is rapidly assimilated and accumulated primarily in needles and roots; (2) this accumulated N is later remobilized to support new growth; and (3) the nutrient pulse leads to a larger second flush of shoot growth. Seedlings increased their N content by 175 mg (67%) in response to the nutrient pulse. Nitrogen was taken up preferentially into younger tissues, especially the secondary flush and current-year roots. Immediately after the nutrient pulse, tissue N concentrations were high and supported subsequent increases in dry mass. Over 3 months, seedlings receiving the nutrient pulse added twice as much dry mass as control seedlings, and even after 3 months of growth, N concentrations remained greater than in controls. Current-year and older needles were the only components whose dry mass did not increase over this period. The nutrient pulse increased the size of the second flush, but it was still a minor component of increments in dry mass (approximately 10% of the total dry mass increment) and N content (23%). The relatively modest increases in N content during autumn could be accounted for by soil uptake and there was no evidence that N was remobilized to support growth of new tissues. Short-term (15 days) elevated N uptake led to sustained growth in the long term (> 3 months), and thus growth rate was to a large extent decoupled from current nutrient supply.

Nitrogen↗

Influence of estradiol and progesterone withdrawal on the secretion of and the temporal correlation between pulses of oxytocin and prostaglandin F2(alpha) in ewes.

The primary objective was to examine the effects of estradiol and the progesterone receptor antagonist onapristone on the pulsatile secretion of prostaglandin F(2alpha) (PGF(2alpha)) and ovarian and pituitary oxytocin. A 2 x 2 factorial arrangement of estradiol and onapristone treatments was administered to groups of 5 ewes after destruction of ovarian follicles on Day 8 of the cycle. Estradiol treatments consisted of the administration of a silicone elastomer implant, either containing or not containing estradiol, on Day 8 plus 50 microg of estradiol or corn oil on Days 11 and 12. Onapristone (2 mg/kg) or its vehicle were administered on Day 13, immediately preceding the simultaneous collection of blood samples from the carotid artery, jugular vein, and vena cava at 7.5-min intervals for 7 h. Ewes were immediately killed for measurements of uterine oxytocin receptor concentrations and phosphatidylinositide turnover. More oxytocin pulses were detected in the jugular vein than in the carotid artery (p < 0.01), suggesting that the pituitary is a source of oxytocin. A similar number (p > 0.1) of PGF(2alpha) pulses were correlated with oxytocin pulses as were not. The linked PGF(2alpha) pulses were longer in duration (p = 0.01) with a tendency toward a higher amplitude (p = 0.08). The corresponding vena caval oxytocin pulses had a longer duration (p = 0.02) than those not linked to PGF(2alpha). Estradiol increased oxytocin receptor concentrations and the turnover of phosphatidylinositides (p = 0.02) without affecting PGF(2alpha) pulse characteristics. Onapristone increased (p = 0.03) PGF(2alpha) pulse amplitude. Although a lower than expected temporal correlation between oxytocin and PGF(2alpha) pulses was observed, the distinguishing characteristics of linked pulses may be indicative of their physiological significance.

Animals↗

Dendritic cells pulsed with hepatitis C virus NS3 protein induce immune responses and protection from infection with recombinant vaccinia virus expressing NS3.

Infections with Hepatitis C virus (HCV) pose a serious health problem worldwide. In this study, the hypothesis that adoptive transfer of dendritic cells (DCs) pulsed with HCV NS3 protein and matured with an oligodeoxynucleotide (ODN) containing CpG motifs (CpG) ex vivo would initiate potent HCV-specific protective immune responses in vivo was tested. NS3 protein was efficiently transduced into DCs and treatment of DCs with CpG ODN induced phenotypic maturation and specifically increased the expression of CD40. DCs matured with CpG ODN produced higher interleukin 12 levels and a stronger allogeneic T-cell response compared with untreated DCs. Notably, there were no differences between NS3-pulsed DCs and DCs pulsed with a control protein with respect to phenotype, cytokine production or mixed lymphocyte reaction, indicating that transduction with NS3 protein did not impair DC functions. Compared with the untreated NS3-pulsed DCs, the NS3-pulsed DCs matured with CpG ODN induced stronger cellular immune responses including enhanced cytotoxicity, higher interferon-gamma production and stronger lymphocyte proliferation. Upon challenge with a recombinant vaccinia virus expressing NS3, all mice immunized with NS3-pulsed DCs showed a significant reduction in vaccinia virus titres when compared with mock-immunized mice. However, the NS3-pulsed DCs matured with CpG ODN induced higher levels of protection compared with the untreated NS3-pulsed DCs. These data are the first to show that NS3-pulsed DCs induce specific immune responses and provide protection from viral challenge, and also demonstrate that CpG ODNs, which have a proven safety profile, would be useful in the development of DC vaccines.

Animals↗

Spatiotemporal structure of isodiffracting ultrashort electromagnetic pulses

We present a model of isodiffracting single-cycle and few-cycle ultrashort electromagnetic pulses. The model is based on exact solutions of the time-dependent paraxial wave equation with space-time coupling effects included. The spatiotemporal structure of these pulses is characterized by a scaling parameter which relates off-axis pulse shapes to the axial temporal waveforms. Depending on the spectrum a pulse may transform itself from a single-cycle pulse to a multicycle pulse along the radial coordinate. This model is also used to describe recirculating pulses in a curved mirror cavity resonator. The Gouy phase shift contributes an absolute phase that results in a pulse-to-pulse temporal instability.

Journal Article↗

Stabilization of stationary excitation pulses in an open flow without long-range inhibition.

We study numerically and experimentally the stabilization of stationary excitation pulses in an open flow system. Since all the species have equal flow and diffusion coefficients, stabilization of stationary pulses by long-range inhibition is excluded. Upstream propagating pulses slow down as they approach the inflow boundary, where a constant forcing establishes a downstream extending subexcitable boundary layer. When the flow velocity is low, successive pulses vanish as they reach the subexcitable region. When the flow velocity is increased, the incoming pulses pile up near the inflow one after the other to form a stationary and space-periodic structure. This occurs in such a manner that the system remembers and stores the number of incoming pulses. We show that flow-induced stabilization of stationary pulses involves a mechanism by which the upstream subexcitable region and the flow cause the arrest of the pulse front and the pulse back, respectively. We discuss how the flow-stabilized structures compare to, and are different from those stabilized by a long-ranged, diffusive inhibition and from those observed in boundary-forced open flows of media showing relaxation-type oscillations.

Journal Article↗

Acceleration element for femtosecond electron pulse compression.

An acceleration element is proposed for compressing the electron pulse duration in a femtosecond photoelectron gun. The element is a compact metal cavity with curved-shaped walls. An external voltage is applied to the cavity where a special electric field forms in such a way that the slow electrons in the electron pulse front are accelerated more than the fast electrons, and consequently the electron pulse duration will be compressed. The distribution of the electric field inside the acceleration cavity is analyzed for the geometry of the cavity. The electron dynamics in this acceleration cavity is also investigated numerically. Numerical results show that the electron pulse front and pulse duration can be improved by compensating for the effects of space charge and the initial energy spread of photoelectrons with a Lambertian angular distribution. Depending on the design parameters and the shape of the electron pulse, for a femtosecond electron gun with an electron energy of 30 keV, 10(3) electrons per pulse, and an electron drift length of 40 cm, the electron pulse duration can be reduced from 550 to 200 fs when using a compensating cavity with an average radius of 1.7 and 5.6 cm in length. Electron pulses shorter than 200 fs can be achieved if the length of the drift region is reduced.

Journal Article↗

Pulse delay and propagation through subwavelength metallic slits.

The transmission properties of a 2D metallic grating are investigated at optical wavelengths for an incident Gaussian pulse having pulse widths from 100 fs to 10 ps. The slits in the grating are subwavelength which can nevertheless allow significant transmission in the narrow wavelength regions where the so-called surface plasmon polariton (SPP) and waveguide mode resonances occur. The solution is obtained for each spectral component of the pulse by using the rigorous coupled wave approach and then the temporally varying output pulse is reconstructed by the standard method of taking an inverse Fourier transform. The delay of the pulse and the output pulse widths are determined by taking the first and second order moments of the Poynting vector with respect to time. It is shown that the time delay may be significant, as much as 256 fs for a pulse width of 200 fs for the SPP resonance but quite small (32 fs) for the waveguide mode resonance. The focus of the work is on demonstrating how the pulse delay evolves as the pulse propagates in the half-space beyond the grating. It is shown that the distance over which the time delay develops is much larger than the actual longitudinal dimension of the grating structure and it is approximately the same distance over which the stored energy and the vortices of the Poynting vector extend.

Journal Article↗