Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PALPATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Sacroiliac joint diagnostics in the Hamburg Construction Workers Study.

BACKGROUND: In the medical literature, test procedures for sacroiliac joint diagnostics are viewed as controversial. The provocation tests are based on provoked sacroiliac pain, whereas the palpation tests examine the motion of the sacroiliac joint or describe the condition indirectly if limitation of the sacroiliac function is present. It must be presumed that the use of different test results in the detection of varying functional phenomena of a sacroiliac dysfunction or, alternatively, that identical effects of a dysfunction are evaluated in differing ways. OBJECTIVE: This article presents results with regard to the consistency of tests for sacroiliac joint dysfunctions carried out on participants from the building trade. DESIGN AND PARTICIPANTS: The consistency of the tests (standing flexion test, spine test, iliac compression test, iliac springing test) used in a cross-section investigation of a cohort of 480 male construction workers is presented. To evaluate the degree of consistency of the test procedure the percentage agreement and the kappa value, including a confidence interval of 95%, are given. RESULTS: The consistency between the iliac compression test and the three sacroiliac palpation tests could not be shown to be statistically significant. The consistency between the three palpation tests was moderate to good and the percentage agreement was acceptable (87.4%, 88.6%, 80.9%). CONCLUSIONS: It may be assumed that the palpation tests characterize the same dysfunction of the sacroiliac joint. Standing flexion test, spine test, and iliac springing test seem to be valuable tools for sacroiliac joint diagnostics.

Adult↗

[Results of pretherapeutic lymph node diagnosis in head and neck tumors. Clinical value of 18-FDG positron emission tomography (PET)].

BACKGROUND: Histological studies demonstrate that there is a high percentage of occult nodal metastasis in head and neck malignomas. Patients with positive lymph nodes have a comparatively worse prognosis. A neck dissection is required in these cases. By demonstrating morphological abnormalities, imaging procedures like ultrasound, computer tomography (CT), and magnetic resonance imaging (MRI) can provide important initial informations about possible malignant alteration of the lymph nodes. Positron emission tomography (PET) allows functional metabolic imaging of a suspected tumor site. The aim of this study was a comparative evaluation of different diagnostic procedures with special emphasis on the value of PET in the pretherapeutic diagnosis of nodal spread in head and neck cancer. PATIENTS AND METHODS: Forty patients (28 male and 12 female) with a suspected malignoma in the head and neck region underwent clinical examination including palpation of the neck sides, ultrasound, CT, and PET to detect a nodal spread of the malignancy. Fifty neck dissections were performed in 28 patients. Lymph node biopsies were performed in the remaining patients. The results of the diagnostic procedures were compared to the histology and the clinical course of the patients. The mean follow-up period was 12.5 months. RESULTS: A nodal metastasis was verified in 35% of all cases. Sensitivity of all imaging procedures including PET was 82%. Palpation had a sensitivity of only 61%. Specificity was 85% for ultrasound, 94% for CT and palpation, and 87% for PET. PET produced false negative results in 13.4% of all cases. Inflammation was detected in these cases. The positive predictive value was marginally better for PET than for ultrasound (77% vs. 75%). It proved to be lower than the values for palpation (86%) and CT (88%). Negative predictive value was 90-91% for all imaging procedures. CONCLUSION: In the primary diagnosis of nodal alterations in the head and neck region, a PET scan has the same diagnostic value as ultrasound or CT. By imaging the metabolism of a suspected nodal metastasis, PET can help to improve the assessment of regions with uncertain anatomic features. To avoid false positive results, acute and chronic inflammatory alterations have to be ruled out before the PET imaging.

Aged↗

Percutaneous endoscopic gastrostomy placement using the pull-through or push-through techniques: is the second pass of the gastroscope necessary?

BACKGROUND AND STUDY AIMS: The pull-through and push-through techniques widely used for placing a percutaneous endoscopic gastrostomy (PEG) require two passes of the gastroscope. The second pass is considered necessary to assess the correct positioning of the internal bumper. The aim of the present study was to verify whether the second pass is in fact necessary, or whether it could be omitted in most cases. PATIENTS AND METHODS: Eighty patients undergoing pull-through or push-through PEG placement were included in this prospective study, and were randomly assigned to two groups. In the first group, two passes of the gastroscope were carried out, while in the second group the second pass was omitted and the position of the internal bumper was manually assessed by finger palpation of the abdominal wall after the feeding tube had been pulled out through the abdomen. If finger palpation was not considered satisfactory, a control gastroscopy was carried out. In the other cases, plain radiographs of the abdomen were carried out within six hours of the procedure. RESULTS: Thirty-nine patients underwent two-pass PEG placement, and 41 received one-pass PEG placement. In one patient who had a one-pass procedure, the finger palpation was not considered satisfactory; however, a control gastroscopy showed that the internal bumper was correctly placed. In all other one-pass PEG patients, plain radiography of the abdomen showed that the internal bumper was at an adequate distance from the abdominal wall. No major or minor complications associated with the procedure were observed in either group. Bowel sounds reappeared within 24 hours of the procedure in all patients except for one in the two-pass group, in whom they reappeared after 36 hours. One wound infection, treated with systemic antibiotics, occurred in each group within 30 days of the PEG placement. The procedure time saved in the one-pass PEG group averaged 1.5 minutes. CONCLUSIONS: One-pass PEG placement appears to be as safe as the classic pull-through and push-through PEG methods, and can be used routinely to make the procedure quicker and reduce the discomfort for the patient, as well as reducing the risks and costs associated with the second pass of the gastroscope. A control gastroscopy can be reserved for patients with morbid obesity, or for cases in which finger palpation is not considered satisfactory.

Adult↗

[High-resolution realtime sonography of varicoceles].

An attempt has been made to classify varicoceles by means of real time sonography in accordance with the findings on palpation. The maximal diameter of the pampiniform plexus and of individual veins was determined sonographically and compared with the results of palpation in 74 patients with varicoceles. The sonographic findings are more accurate than is palpation. Fifteen subclinical varicoceles were discovered by sonography which could not be detected by palpation. It has been found convenient to classify the lesions in four sonographic stages. Maximal transverse diameter of the pampiniform plexus up to one centimetre is regarded as normal. A diameter of one to two centimetres corresponds to grade I, two to three centimetres corresponds to grade II and greater than three centimetres to grade III.

Humans↗

Lymphoscintigraphy for interpretation of changes of cervical lymph node function in patients with oral malignant tumors: comparison of Tc-99m-Re and Tc-99m-HSA-D.

OBJECTIVE: The purpose of this study is to compare the usefulness of technetium-99m-rhenium colloid (Tc-99m-Re) and technetium-99m-human serum albumin diethylene-triamine-pentaacetic acid (Tc-99m-HSA-D) as lymphoscintigraphic agents and to discuss the significance of lymphoscintigraphy in comparison with computed tomography (CT), magnetic resonance imaging (MRI), and ultrasonography (US). STUDY DESIGN: Dynamic and static lymphoscintigraphies were performed with Tc-99m-Re and Tc-99m-HSA-D. The usefulness of the 2 agents was evaluated statistically in comparison with pathologic findings and palpation. The significance of lymphoscintigraphy is discussed in comparison with CT, MRI, and US (by the literature of CT, MRI, and US). RESULTS: Lymphoscintigraphy was superior to palpation, and Tc-99m-Re was superior to Tc-99m-HSA-D in accuracy, specificity, and the incidence of true-positive and false-positive. Statistical significance was shown between the static lymphoscintigraphy with Tc-99m-Re and palpation. The reliability of lymphoscintigraphy seemed to be slightly inferior to CT and MRI in specificity and accuracy. However, lymphoscintigraphy had some advantages that CT and MRI lacked; for example, it showed very high sensitivity (100%) and no false-negative (0%). It also showed changes of lymph node function, showed all levels of neck nodes at one time, and showed a possibility of detecting small lymph node metastases. CONCLUSION: Lymphoscintigraphy was more useful than palpation in detecting lymph node metastases, and Tc-99m-Re was superior to Tc-99m-HSA-D as an agent. Lymphoscintigraphy is significant when it is performed as a preliminary examination before CT or MRI.

Adult↗

Staging N0 oral cancer: lymphoscintigraphy and conventional imaging.

PURPOSE: To compare sentinel lymph node biopsy, magnetic resonance imaging (MRI), Doppler ultrasonography, and palpation as staging tools in patients with T1/T2 N0 cancer of the oral cavity. MATERIAL AND METHODS: Forty consecutive patients were enrolled (17 F and 23 M, aged 32-90 years), 24 T1 and 16 T2 cN0 squamous cell carcinoma of the oral cavity. Palpation was carried out by two observers prior to inclusion. MRI, gray-scale and Doppler ultrasonography were performed. Lymphoscintigraphies were done after peritumoral injections of 99mTc labelled rheniumsulphide nanocolloid, followed by sentinel lymph node biopsy guided by a gamma probe and Patent Blue. Palpation, Doppler ultrasonography, MRI, and sentinel lymph node biopsy were compared to a combination of histopathology and follow-up. Diagnostic testing was performed using the x2 test. RESULTS: Histopathological examination revealed metastatic spread to the neck in 14 of 40 patients. One patient had bilateral neck disease. Sentinel lymph node biopsy and ultrasonography were performed in 80 neck sides of 40 patients and MRI in 70 neck sides (5 patients were claustrophobic). SN revealed suspicious lymph nodes in 12 necks, ultrasonography in 23 necks, and MRI in 9 necks. The positive predictive value of sentinel lymph node biopsy was 100%, ultrasonography 57%, and MRI 56%. The respective negative predictive values were 96%, 96%, and 85%. The sensitivity of sentinel lymph node biopsy 80% was comparable to ultrasonography 87%, but the sensitivity of MRI 36% was low. The specificities were 100%, 85%, and 93%, respectively. By combined sentinel lymph node biopsy and ultrasonography the overall sensitivity could have been 100%. CONCLUSION: Sentinel lymph node biopsy improved staging of patients with small N0 oral cancers. Combined sentinel lymph node biopsy and Doppler ultrasonography may further improve staging. MRI and simple palpation results were poor.

Adult↗

Ultrasound guidance allows accurate needle placement and aspiration from small joints in patients with early inflammatory arthritis.

OBJECTIVES: To compare the accuracy of palpation-guided and high frequency ultrasound-guided needle placement in small joints and to develop a technique to obtain synovial fluid from these joints for diagnosis and research. METHODS: The accuracy of needle placement during palpation-guided proximal interphalangeal (PIP) or metacarpophalangeal (MCP) joint injection was assessed. This was compared with the accuracy of ultrasound-guided needle placement. A joint lavage technique was developed to obtain synovial fluid from these joints. RESULTS: Needle positioning was intra-articular in 59% of palpation-guided injections (6/12 PIP and 4/5 MCP joints). No fluid could be aspirated prior to injection. With ultrasound guidance, initial needle placement was intra-articular in 96% of cases (24/26 PIP and 27/27 MCP joints). Synovial fluid cells were lavaged from 63% of joints (19/25 PIP and 14/27 MCP joints). In only one case was a large effusion seen and this was aspirated directly. CONCLUSIONS: The use of high frequency ultrasound to guide needle placement within a small joint allows for significantly greater accuracy than a palpation-guided approach. When followed by lavage, synovial fluid cells and diluted synovial fluid can be obtained from the majority of small joints. This has important clinical and research implications.

Arthritis↗

Comparison of two techniques for detecting cardiac activity in infants.

In the 1980 Standards and Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiac Care, the recommended method for determining cardiac arrest in infants was changed from palpation of the apical impulse to palpation of the brachial pulse. The importance of adequately assessing the heart beat before initiating chest compressions due to the potential hazards is well established. This study was designed to ascertain which pulse parents could palpate most readily and accurately count within a given time. The results demonstrated the brachial pulse was much easier to palpate and more accurately counted by parents than the apical impulse. These findings formed the basis for the 1980 revised recommendation for determining cardiac arrest in infants.

Arm↗

Heartbeat assessment in infants: a comparison of four clinical methods.

OBJECTIVE: To compare the performance of four clinical methods (apex ear auscultation; brachial, carotid, and femoral pulse palpation) for detecting and counting heart beat in infants. DESIGN: Cross-sectional, repeated-measures study design. Prospective data collection. SETTING: A postanesthesia care unit of a pediatric teaching hospital in Italy. PATIENTS: Fifty-six normotensive sedated infants, aged 1-12 mos, were evaluated by 14 pediatric basic life support (PBLS)-qualified health professionals. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The proportion of successful heartbeat detections ranged from 60% with carotid pulse palpation to 98% with apex auscultation. Among successful detections, apex auscultation proved to be the most rapid way to detect heart rate (median, 4 secs) and the most accurate with a median discrepancy of 8 beats/min (vs. 12 with the other methods) from the electrocardiographic results. Differences between apex auscultation and pulse palpation were statistically significant (p < .0001). In contrast, no significant differences were found among the three methods of pulse checking. CONCLUSIONS: Apex listening is the most successful, rapid, and accurate method to detect and count the heartbeat by PBLS-certified professionals in normotensive infants without instruments. Pulse checking remains important for assessing the effectiveness of circulation. Palpating the brachial, carotid, or femoral pulse is equally effective.

Arteries↗

Biologic aggressiveness of palpable and nonpalpable prostate cancer: assessment with endosonography.

The biologic aggressiveness of palpable versus nonpalpable prostate cancer was evaluated in 666 patients studied with endosonography over a 24-month period. Biologic aggressiveness was defined by a combined histologic and grade-stage category score. In 314 patients suspected of having prostate cancer 328 biopsies were performed. Carcinoma was detected in 99 patients, by means of both palpation and endosonography (n = 80), endosonography alone (n = 9), and palpation alone (n = 8); two cancers were not detected with either palpation or endosonography. All patients with normal results of digital examination had a combined grade-stage category score lower than 9. Fifty-five of 69 patients (80%) with abnormal results of digital examination and available histologic data had a histologic score of 6 or higher; 38 of these patients (69%) had a combined grade-stage category score of 9 or higher. Although the number of patients is small, these data suggest that nonpalpable cancers are biologically less aggressive than palpable ones and that the advantage of endosonography over palpation in detection of clinically significant cancers is limited.

Adenocarcinoma↗

Biofeedback and pelvic floor exercises for the rehabilitation of urinary stress incontinence.

We investigated the effectiveness of pelvic floor muscle (PFM) exercises or biofeedback for the treatment of urinary stress incontinence (USI). Fifty patients with USI were included in this randomized, controlled, prospective study. Twenty patients were taught PFM exercises via digital palpation and instructed to perform regularly as home program. The second group of 20 patients had PFM exercises via biofeedback three times a week for 2 months. The third group of 10 patients did not have any exercises. The patients were evaluated via pad test, perineometry, digital palpation based PFM strength, incontinence frequency, and visual analog scale based social activity index prior to and 8 weeks after the treatment. The first two groups had significant improvement in USI with respect to the control group (p < 0.001). The rise in PFM strength with perineometry of the biofeedback group was higher than in the digital palpation group after treatment (p < 0.001). PFM exercises are effective for the treatment of USI; the biofeedback method revealed better PFM strength results with respect to digital palpation.

Biofeedback, Psychology↗

A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters.

BACKGROUND: Arterial cannulation for continuous blood-pressure measurement and frequent arterial-blood sampling commonly are required in critically ill patients. OBJECTIVES: To compare ultrasound (US)-guided versus traditional palpation placement of arterial lines for time to placement, number of attempts, sites used, and complications. METHODS: This was a prospective, randomized interventional study at a Level 1 academic urban emergency department with an annual census of 78,000 patients. Patients were randomized to either palpation or US-guided groups. Inclusion criteria were any adult patient who required an arterial line according to the treating attending. Patients who had previous attempts at an arterial line during the visit, or who could not be randomized because of time constraints, were excluded. Enrollment was on a convenience basis, during hours worked by researchers over a six-month period. Patients in either group who had three failed attempts were rescued with the other technique for patient comfort. Statistical analysis included Fisher's exact, Mann-Whitney, and Student's t-tests. RESULTS: Sixty patients were enrolled, with 30 patients randomized to each group. Patients randomized to the US group had a shorter time required for arterial line placement (107 vs. 314 seconds; difference, 207 seconds; p = 0.0004), fewer placement attempts (1.2 vs. 2.2; difference, 1; p = 0.001), and fewer sites required for successful line placement (1.1 vs. 1.6; difference, 0.5; p = 0.001), as compared with the palpation group. CONCLUSIONS: In this study, US guidance for arterial cannulation was successful more frequently and it took less time to establish the arterial line as compared with the palpation method.

Blood Pressure↗

The relationship between clinical and MRI findings in patients with unilateral temporomandibular joint pain.

BACKGROUND: With the advent of magnetic resonance imaging, or MRI, clinicians and researchers have sophisticated techniques by which to assess the anatomy of the temporomandibular joint, or TMJ. Imaging is indicated when the results will affect the patient's care beyond that which can be gained from a complete clinical assessment. One of the primary indications for treatment of patients with temporomandibular disorders, or TMDs, is jaw pain, including TMJ pain. Therefore, it is necessary to assess whether MRI-depicted TMJ findings are associated with TMJ pain. This study assessed the relationship between TMJ pain and clinical and MRI findings. METHODS: Subjects consisted of 85 patients with unilateral jaw pain in the area of the TMJ. The contralateral, nonpainful TMJ served as the matched control. All patients underwent a complete stomatognathic examination that included palpation of both TMJs. No care was given and no anti-inflammatory medications were prescribed until bilateral MRIs were obtained within one week. RESULTS: The authors found significant relationships between the side of reported jaw pain and the patient's report that palpation of the TMJ was painful and between the side of reported pain and the presence of MRI-detected effusions. The authors found no relationship between the side of reported pain and the presence of a disk displacement, or DD, or between the presence of effusions and DD on either side of the jaw. CONCLUSION: Although MRI-depicted effusions of the TMJ were associated with reports of TMJ pain, there was a high level of false-positive and false-negative findings. The results indicate that palpation of the TMJ is more accurate than MRI-depicted effusions in identifying the TMJ as the source of pain for patients with unilateral jaw pain. CLINICAL IMPLICATIONS: The results of this study suggest that palpation of the TMJ is superior to MRI in identifying the joint as the source of pain. Therefore, the most cost-effective and valid test to determine if the TMJ is a source of jaw pain is a complete clinical assessment.

Adolescent↗

Pressure algometry to quantify muscle pain in racehorses with suspected sacroiliac dysfunction.

REASONS FOR PERFORMING STUDY: Despite the prevalence of orthopaedic injuries to horses, there is no objective means of quantifying the intensity of musculoskeletal pain. HYPOTHESES: Mechanical nociceptive thresholds (MNT) can be measured repeatably by pressure algometry in horses and MNTs are correlated with both severity of clinical signs and subjective scores of muscle pain on palpation in horses with suspected sacroiliac dysfunction (SID). METHODS: The technique of pressure algometry and its repeatability was tested at 4 anatomical sites on either side of the thoracolumbar and pelvic region in 12 Thoroughbreds in training. In a second series of 15 racing Thoroughbreds, using a different set of landmarks, pain on palpation was assessed by pressure algometry. Horses were grouped based on clinical scores of SID as normal (n = 5), mild (n = 5), moderate (n = 4) and severe (n = 1) suspected SID and scored for muscle pain response by manual palpation. RESULTS: Pressure algometry was shown to be a repeatable measure of MNTs. Horses with suspected SID had significantly lower mean MNT when sites and horses were pooled and showed greater differences in mean algometer measurements between left and right sides, compared to control horses. A significant correlation was found between mean pressure algometry measurements and both suspected SID grade and muscle pain response on palpation. CONCLUSION AND POTENTIAL RELEVANCE: Horses with suspected SID displayed lower MNTs compared to control horses, especially in the pelvic region. This supports a potential role for pressure algometry in providing an objective means of quantifying musculoskeletal pain reflected as a reduced MNT associated with SID and its response to physiotherapy or other treatments.

Animals↗

Detection of estrus in dairy cows by electrical measurements of vaginal mucus and by milk progesterone.

Electrical resistance (ohms) of mucus were analyzed in 20 postpartum Holstein cows by use of a probe inserted into the anterior vagina every other day for 30 days. Composite milk samples were taken on the same day, and progesterone was determined by radioimmunoassay. Cows were observed twice daily for standing estrus and reproductive organs palpated weekly per rectum (rectal palpation). Fifteen cows which were cycling showed increasing progesterone 6 to 7 days after the onset of estrus with values of 8.1 to 10.0 ng progesterone/ml milk on days 10 to 17. Concentrations had declined rapidly 2 days before onset of the next estrus. Progesterone in milk was affected by cow and by day of the cycle. Electrical resistance followed a similar cyclical pattern, but variability was large and only cows differed. The correlation between milk progesterone and mucus resistance was .22. Progesterone concentrations for four cows with follicular cysts fluctuated randomly with a mean of 2.6 ng/ml. Mean resistance of vaginal mucus was 44 omega for both cycling and cystic cows, indicating that a single measurement of electrical resistance every 2nd day was unreliable in distinguishing physiological states. One cow had high progesterone in milk on days 19 to 25 and was diagnosed pregnant by rectal palpation 3 wk later. Cows were not seen in estrus 28% of the time when milk progesterone and rectal palpation indicated they were in the follicular phase of the estrous cycle and were cycling.

Animals↗

Use of prostaglandin F2 alpha as a postpartum reproductive management tool for lactating dairy cows.

This study compared three programs for reproductive management of the postpartum period for reproductive performance and net economic benefit within three dairy herds (n = 1624 cows). Cows on one program received PGF alpha injection at 25 to 32 d postpartum for reproductive therapy, and cows on a second program received additional PGF2 alpha at 39 to 46 d postpartum for synchronization of estrus. These programs were compared with a postpartum program of rectal palpation based on veterinary intervention. Survival analysis indicated that cows receiving PGF2 alpha for reproductive therapy and synchronization of estrus had an 11% higher rate of first AI and 10% higher rate of pregnancy than did cows receiving the rectal palpation. No differences existed between the cows receiving rectal palpation and those receiving the PGF2 alpha. Because overall conception rates and conception rates at first AI did not differ among programs, the improved reproductive performance of cows receiving PGF2 alpha for both therapy and synchronization may be attributed to greater synchronization of estrus, which resulted in improved estrus detection. A partial budget indicated that the PGF2 alpha programs were less expensive than the rectal palpation program. When PGF2 alpha was used for postpartum reproductive therapy and synchronization of estrus, reproductive performance and net economic benefit were increased compared with those of the other programs.

Animals↗

Evaluation of different protocols for prostaglandin synchronization to improve reproductive performance in dairy herds with low estrus detection efficiency.

The objective of this study was to evaluate different PGF2 alpha protocols against control protocols for herds with estrus detection efficiencies of 35, 55, and 75% using modeling and simulation: 1) PGF2 alpha treatments based on the presence of a corpus luteum diagnosed by rectal palpation, 2) PGF2 alpha treatments based on the presence of a corpus luteum diagnosed by an on-farm milk progesterone enzyme immunoassay, and 3) PGF2 alpha treatments based on a 14-d fixed treatment schedule without prior screening for ovarian status. After the start of each protocol, estrus detection efficiency was 75% for 7 d after treatment and 35 or 0% for the following week. For the third protocol, an additional modification at estrus detection efficiencies of 85 and 55%, respectively, in the 1st and 2nd wk after treatment was evaluated to establish a protocol for best case assumptions. All protocols improved reproductive performance relative to that of controls with estrus detection efficiencies of 35 and 55%. The mean number of days open was reduced from 124.3 d in the control herd to 95.9, 95.0, and 92.7 for the protocols based on rectal palpation, milk progesterone test, and the fixed treatment schedule, respectively. The protocols based on a fixed treatment schedule were superior to protocols based on rectal palpation and on-farm milk progesterone tests and resulted in better reproductive performance and a higher increase in net return per cow per year. Relative to a control herd with an estrus detection efficiency of 55%, it was cost effective to spend up to $10 per dose of PGF2 alpha, $9 per milk progesterone test, and $6 per rectal palpation.

Animals↗

Topographic diagnosis and surgical treatment of insulinoma.

AIM: Controversy continues to reign with regard to the need for preoperative localization of insulinomas and to which are the most sensitive and accurate diagnostic imaging modalities. Our aim was to determine the role of diagnostic procedures and suggest which of them are really useful. METHODS: Over a 12-year period 34 patients underwent several preoperative diagnostic procedures to localize the insulinoma: ultrasonography (US) in 20 cases, computed tomography (CT) in 26, magnetic resonance imaging (MRI) in 28, selective angiography in 8, arterial stimulation venous sampling (ASVS) in 23 and Octreoscan in 26. All patients underwent surgical palpation and in 32 cases intraoperative ultrasonography (IOUS) was performed. Twenty-six cases underwent enucleation, six had distal pancreatic resections and two patients had only exploratory laparotomy with liver biopsies. We compared the findings of the diagnostic procedures and analyzed the surgical treatment chosen according to the pancreatic site of the tumor. RESULTS: In 32 (94.1%) of the 34 patients with clinically suspected pancreatic insulinoma the tumor was found at surgery. Preoperative US achieved 5.2% sensitivity, CT 29.1%, selective angiography 28.5% and MRI 76.9%. ASVS achieved 91.3% sensitivity and diagnostic accuracy whereas Octreoscan achieved only 65.3% diagnostic accuracy. Surgical palpation performed before IOUS identified the tumors in 30/34 patients: in the other four cases, one was a false-positive result (a cyst in the pancreatic head), two were true negatives and one was a false negative. Surgical palpation therefore yielded 88.2% diagnostic accuracy. IOUS was performed in 32 cases and localized the tumors in 29/32 cases (sensitivity: 96.6%) with one false-negative result (diagnostic accuracy: 96.8%). The operative mortality was 2.9% and the morbidity 24.6% (30.7% in patients treated by tumor enucleation). CONCLUSIONS: No single diagnostic imaging modality is reliable for localizing insulinoma. We therefore suggest combined MRI, ASVS and IOUS. ASVS provides particularly useful information for planning manual palpation and intraoperative ultrasonography.

Adolescent↗