Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MONITORING SYSTEMS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

The glycemic response to meals with six different fruits in insulin-dependent diabetics using a home blood-glucose monitoring system.

Glycemic effect of adding 10-g carbohydrate portions of apple, banana, grapes, honeydew, orange, or strawberries to a standard meal on separate occasions was measured in 10 insulin-dependent diabetics monitored at home. The meal comprised 29% of total daily caloric intake and contained green beans, rice, turkey, and margarine (50% carbohydrate, 20% protein, and 30% fat). Blood-glucose response to meals containing grapes, honeydew, orange, or strawberries was slightly higher than meals containing apple, banana, or no fruit and the small amount of starch in apple and banana may have contributed to their lower blood-glucose response compared to the other fruits tested. Age, duration of diabetes, or insulin regimen did not correlate with subjects' responses to fruit.

Adolescent↗

Surveillance systems monitoring HIV/AIDS and HIV risk behaviors among American Indians and Alaska Natives.

Few published reports describe patterns of occurrence of HIV/AIDS among American Indian/Alaska Native (AI/AN) people nationally. Data from national surveillance systems were examined to describe the spread of HIV/AIDS and the prevalence of HIV-related risk behaviors among AI/AN people. These data indicate that HIV/AIDS is a growing problem among AI/AN people and that AI/AN youth and women are particularly vulnerable to the continued spread of HIV infection.

Adolescent↗

[Monitoring system of cerebral blood flow and cerebral metabolism. Part II. Relationship between internal jugular O2 tention and cerebral blood flow (author's transl)].

Changes of PjO2 values of internal jugular vein were monitored in patients with various types of cerebrovascular disease. The significance of PjO2 monitoring was evaluated. 1) Control value of PjO2 in thirteen normal control cases was 36.7 +/- 1.9 mmHg (mean +/- SD). 2) Limit of brain hypoxia showing no neurological sign and symptom in patients with occlusive cerebrovascular disease was studied by the stepwise reduction of arterial blood pressure, using drip infusion of trymetaphan camsylate, under the careful monitoring of signs and symptoms and monitoring of PjO2 and EEG. Appearance of signs and symptoms of brain hypoxia were checked by yawning and EEG slowing. At the time of the appearance of brain hypoxia PjO2 was 28.6 +/- 3.2 mmHg. 3) CO2 reactivity of CBF was studied in patients with occlusive cerebrovascular disease. Relation between PaCO2 and PjO2 was as follows; PjO2 = 0.68 . PaCO2 + 7.55 4) Within 24 hours after the onset of stroke, ipsilateral PjO2 of the cases with disturbance of consciousness was lower than that of the cases without disturbance of consciousness, which might indicate the significant decrease of CBF in the former cases. During 3rd to 7th day after the onset the cases with disturbance of consciousness showed the significant elevation of PjO2, which might indicate the reduction of cerebral metabolism. 5) The elevation of ipsilateral PjO2 were well correlated to the degree of hemispheric brain swelling. 6) During general convulsion, high level of PjO2 values were observed. 7) PjO2 values were inversely correlated to the hemoglobin values after blood transfusion, which was mainly due to the decrease of CBF by high content of hemoglobin.

Adult↗

In-vitro and in-vivo comparative analysis of four tissue pH monitoring systems.

The purpose of this investigation was to identify the type of pH-reference electrode combination that is the most suitable and reliable in clinical applications involving long-term postoperative monitoring of microvascular reconstructive transplants and diagnosis of compartment syndrome. Four types of pH-sensing devices were chosen for the study: a standard glass pH electrode, a polymer-based pH electrode, an ISFET pH sensor, and a fiberoptic pH sensor. Various combinations of electrodes were tested in vitro for typically four days. The glass and polymer electrodes maintained stable pH readings, averaging drifts of 0.14 +/- 0.07 and 0.14 +/- 0.08 pH units per 96 hours, respectively. The fiberoptic sensors displayed an average drift of 0.20 +/- 0.15 pH units per 96 hours. ISFET sensors displayed nearly linear drifts, averaging 1.36 +/- 0.54 pH units per 96 hours. When placed in healthy animal tissue, glass and polymer electrode pH readings followed the arterial blood pH values, measured by a blood gas analyzer. In compromised tissue, both glass and polymer electrodes recorded falling pH levels correctly, indicating ischemic conditions. Generally, ISFET sensors in healthy tissue produced pH readings that did not correlate well with arterial blood pH values. Fiberoptic sensors monitored healthy-tissue pH correctly; however, mechanical disturbances of the fiberoptic sensor and occasional discontinuation of computer operation would shift the pH output significantly (at times by 0.2 pH units), resulting in subsequent inaccurate pH readings. The glass electrode was the only sensor evaluated clinically. It correctly indicated tissue viability in all clinical cases, involving both healthy and ischemic tissue. The authors conclude that the glass pH electrode has the best combination of characteristics for clinical tissue pH measurements.

Animals↗

Galactomannan enzyme immunoassay for monitoring systemic infection with Aspergillus fumigatus in mice.

Intravenous (i.v.) infection of immunocompetent mice with Aspergillus fumigatus was used to investigate the ability of a commercial galactomannan enzyme-linked immunosorbent assay (ELISA) to monitor the course of organ infection after dissemination. The test detected 100% of the fungemias which occurred for up to 5 days after infection. When blood-cultures became negative but there was a high load of fungi in the parenchymal organs and a positive culture from the brain, the ELISA was again positive in all animals. However, when blood cultures as well as brain cultures were negative and lower amounts of fungi demarcated by immune cells were present in the liver and kidneys which was the case between day 5 and 30 of infection, the test was negative in most of the animals. Therefore, the test was excellent for detection of early i.v. infection with Aspergillus fumigatus but not suited for detection of limited organ infection in immunocompetent mice.

Animals↗

Smart X-ray beam position monitor system using artificial-intelligence methods for the Advanced Photon Source insertion-device beamlines.

At the Advanced Photon Source (APS), each insertion-device (ID) beamline front end has two X-ray beam position monitors (XBPMs) to monitor the X-ray beam position for both vertical and horizontal directions. Performance challenges for a conventional photoemission-type XBPM during operations are contamination of the signal from the neighbouring bending-magnet sources and the sensitivity of the XBPM to the insertion-device gap variations. Problems are exacerbated because users change the ID gap during their operations, and hence the percentage level of the contamination in the front-end XBPM signals varies. A smart XBPM system with a high-speed digital signal processor has been built at the Advanced Photon Source for the ID beamline front ends. The new version of the software, which uses an artificial-intelligence method, provides a self-learning and self-calibration capability to the smart XBPM system. The structure of and recent test results with the system are presented in this paper.

Journal Article↗