Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Krypton”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Three-dimensional graphic reconstruction of the insect exoskeleton through confocal imaging of endogenous fluorescence.

The exoskeleton of the cockroach leg was imaged via confocal microscopy to generate digital graphic reconstructions of its three-dimensional structure. The cuticle is autofluorescent and can be visualized without staining, but is maximally imaged in aldehyde-fixed preparations viewed under krypton-argon laser illumination (yellow green (568 nm) excitation, commonly used in confocal microscopes). Images of the entire trochanteral segment of the leg were constructed as montages from optical sections taken as overlapping series that were coincident in the z-axis. Reconstructions of the exoskeleton from these images showed that strain sensing mechanoreceptors are located in association with buttresses and thickenings that form a consistent internal architecture in both juvenile and adult animals. Accuracy of reconstructions was gauged by embedding specimens in Spurr's resin and histologically sectioning them perpendicular to the optical plane of section (z-axis). Comparison of plastic sections with two-dimensional images generated by "resectioning" the software model showed that reconstructed exoskeleton had a high level of accuracy. Imaging of older and larger animals was limited by the sclerotization and increased thickness of the cuticle. Surface extraction algorithms were used to generate vector graphic files in CAD format for export to software used in engineering and design. Among other potential uses, these models have been studied by Finite Element Analysis to examine the distribution of mechanical strains in the exoskeleton that occur during posture and locomotion. The advantages and limitations of the techniques are discussed. These methods may be used in studying the exoskeleton and the anatomy of cuticular mechanoreceptors of other arthropods to similar advantage.

Animals↗

Aequorea green fluorescent protein: simultaneous analysis of wild-type and blue-fluorescing mutant by flow cytometry.

Aequorea green fluorescent protein (GFP) has been expressed in a variety of cell lines and host organisms. A recent report (Heim et al.: Proc Natl Acad Sci USA 91:12501-12504, 1994) has documented that a GFP mutant with a single amino acid substitution (tyrosine 66 to histidine; Y66H-GFP) elicits altered spectral properties. Whereas wild-type GFP emits with a maximum at approximately 509 nm (green fluorescence), Y66H-GFP fluoresces with a maximum at approximately 448 nm (blue fluorescence). In this study we employed available argon and krypton ion laser lines to investigate the impact of laser excitation wavelength on the detection of Y66H-GEP by flow cytometry. Using transiently transfected 293 cells, a cellular subpopulation with elevated blue fluorescence was detectable with excitation at 407 nm, but not with ultraviolet (UV), 458 nm, or 488 nm excitation. The blue-fluorescing cells were further documented to express Y66H-GFP by immunoblot analysis of sorted cells. Finally, we demonstrated the simultaneous analysis of both wild-type and Y66H-GFP in cotransfected 293 cells using 407 nm excitation while collecting blue fluorescence at 460 +/- 20 nm (Y66H-GFP) and green fluorescence at 525 +/- 25 nm (wild-type GFP). These studies illustrate the potential for assessing differential gene expression by simultaneously analyzing multiple GFP species with multiparameter flow cytometry.

Cell Line↗

Pairs of violet-light-excited fluorochromes for flow cytometric analysis.

We describe pairs of fluorochromes for use with the 407-nm line of a violet-light-enhanced krypton ion laser. These fluorochromes and a previously described violet-light-excited reporter variant, GFP-Vex, fall into two emission classes: blue for Cascade Blue, and green/yellow for Cascade Yellow, Lucifer Yellow, and GFP-Vex. Cascade Yellow is a new fluorochrome that we have synthesized and is used for the first time in the present study. The two emission classes are sufficiently different that Cascade Blue can be paired with Cascade Yellow, Lucifer Yellow, or GFP-Vex in flow cytometric analysis. Furthermore, with proper detection filters, these fluorochromes can be combined with all of the currently used fluorochromes in a three-laser FACS system. With these data, the total number of fluorochromes that can be used as antibody labels for simultaneous detection in combined FACS analysis increases to nine. This study demonstrates the sensitivity and power of the combined use of these reagents in a single eight-color analysis by identifying murine T-lymphocyte subsets that could not otherwise be readily distinguished.

Animals↗

Nine color eleven parameter immunophenotyping using three laser flow cytometry.

BACKGROUND: This study describes a three laser flow cytometer, reagents, and software used to simultaneously evaluate nine distinct fluorescent parameters on one cell sample. We compare the quality of data obtained with (1) full software compensation and (2) the use of partial spectral compensation of selected pairs of parameters in analog hardware, in combination with final software compensation. An application characterizing low frequency murine B cell subpopulations is given. METHODS: The fluorochromes used are: fluorescein (FITC), phycoerythrin (PE), Cy5PE and Cy7PE, excited at 488 nm by an argon laser; Texas Red (TR), allophycocyanin (APC), and Cy7APC excited at 595 nm by a pumped dye laser; and cascade blue (CB) and cascade yellow (CY) excited at 407 nm by a violet-enhanced krypton laser. Custom additions to commercial electronics and an extended optical bench allow the measurement of these nine parameters plus forward and side scatter light signals. RESULTS: We find the use of partial analog compensation reduces the variation in the background staining levels introduced by the compensation process. Novel B cell populations with frequencies below 1% are characterized. CONCLUSIONS: Nine color flow cytometry is capable of providing measurements with high information content. The choice of reagent-dye combinations and the ability to compensate in multi-parameter measurement space are crucial to obtaining satisfactory results.

Animals↗

Fiberoptic bronchoscopic photoradiation in experimentally induced canine lung cancer.

The potential of diagnostic and therapeutic applications of a system using hematoporphyrin derivative (HpD) and laser photoradiation for the localization and treatment of canine lung cancer experimentally induced in the bronchi was studied. Seven cases of canine invasive squamous cell carcinoma were used in this experiment. A dose of 2.5-3.0 mg/kg body weight HpD was administered intravenously in each dog forty-eight hours prior to examination for fluorescence. The violet light source was a krypton ion laser beam. The beam was transmitted via a quartz fiber inserted through the fiberoptic bronchoscope, and an image intensifier was used to detect the fluorescence from the bronchial foci. An argon dye laser was used for treatment of the foci with red light. Six of seven dogs with squamous cell carcinoma revealed fluorescence at the foci. Conversely, the bronchi of controls, consisting of normal dogs, showed no fluorescence. Three dogs with squamous cell carcinoma received treatment. The therapeutic system consisted of photoradiation with an argon dye laser beam also transmitted via a quartz fiber inserted through the fiberoptic bronchoscope and a dose of 2.5-3.0 mg/kg body weight HpD was administered intravenously 72 hours before the procedure. All carcinoma cases showed complete responses.

Animals↗

Statistical evaluation of confocal microscopy images.

BACKGROUND: The coefficient of variation (CV) is defined as the standard deviation (sigma) of the fluorescent intensity of a population of beads or pixels expressed as a proportion or percentage of the mean (mu) intensity (CV = sigma/mu). The field of flow cytometry has used the CV of a population of bead intensities to determine if the flow cytometer is aligned correctly and performing properly. In a similar manner, the analysis of CV has been applied to the confocal laser scanning microscope (CLSM) to determine machine performance and sensitivity. METHODS: Instead of measuring 10,000 beads using a flow cytometer and determining the CV of this distribution of intensities, thousands of pixels are measured from within one homogeneous Spherotech 10-microm bead. Similar to a typical flow cytometry population that consists of 10,000 beads, a CLSM scanned image consists of a distribution of pixel intensities representing a population of approximately 100,000 pixels. In order to perform this test properly, it is important to have a population of homogeneous particles. A biological particle usually has heterogeneous pixel intensities that correspond to the details in the biological image and thus shows more variability as a test particle. RESULTS: The bead CV consisting of a population of pixel intensities is dependent on a number of machine variables that include frame averaging, photomultiplier tube (PMT) voltage, PMT noise, and laser power. The relationship among these variables suggests that the machine should be operated with lower PMT values in order to generate superior image quality. If this cannot be achieved, frame averaging will be necessary to reduce the CV and improve image quality. There is more image noise at higher PMT settings, making it is necessary to average more frames to reduce the CV values and improve image quality. The sensitivity of a system is related to system noise, laser light efficiency, and proper system alignment. It is possible to compare different systems for system performance and sensitivity if the laser power is maintained at a constant value. Using this bead CV test, 1 mW of 488 nm laser light measured on the scan head yielded a CV value of 4% with a Leica TCS-SP1 (75-mW argon-krypton laser) and a CV value of 1.3% with a Zeiss 510 (25-mW argon laser). A biological particle shows the same relationship between laser power, averaging, PMT voltage, and CV as do the beads. However, because the biological particle has heterogeneous pixel intensities, there is more particle variability, which does not make as useful as a test particle. CONCLUSIONS: This CV analysis of a 10-microm Spherotech fluorescent bead can help determine the sensitivity in a confocal microscope and the system performance. The relationship among the factors that influence image quality is explained from a statistical endpoint. The data obtained from this test provides a systematic method of reducing noise and increasing image clarity. Many components of a CLSM, including laser power, laser stability, PMT functionality, and alignment, influence the CV and determine if the equipment is performing properly. Preliminary results have shown that the bead CV can be used to compare different confocal microscopy systems with regard to performance and sensitivity. The test appears to be analogous to CV tests made on the flow cytometer to assess instrument performance and sensitivity. Published 2001 Wiley-Liss, Inc.

Calibration↗

Relative frequency of malaria pigment-carrying monocytes of nonimmune and semi-immune patients from flow cytometric depolarized side scatter.

BACKGROUND: Recently, it was observed that malaria can be detected by performing automated complete blood count analysis including depolarization measurement of scattered laser light. To explain large discrepancies in sensitivity and specificity observed in semi-immune and nonimmune malaria patients, we determined the relative frequencies of malaria pigment-carrying monocytes (PCM) by flow cytometric measurements combined with rare event analysis. METHODS: An experimental cell-sorting unit utilizing argon, krypton, and helium-neon lasers measured the relative frequencies of leukocytes of malaria patients. Single white blood cells showing high intensity in their depolarized side scatter were sorted for subsequent microscopic analysis. RESULTS: From microscopic inspection of sorted cells, we identified malaria PCM as a distinct cluster in scatter diagrams that is well separated from normal leukocytes. For nonimmune patients, the average relative frequency of PCM is 1.5 x 10(-4) (median), for semi-immune patients 8.8 x 10(-4), and for malaria-negative persons 4.4 x 10(-6). Results derived from depolarized side scatter at 488, 633, or 647 nm agree well. Furthermore, malaria pigment-carrying neutrophilic granulocytes were identified microscopically after sorting. We discuss briefly how pigment-carrying neutrophils might be differentiated from normal leukocytes and PCM by using flow cytometry and measuring depolarized side scatter at two wavelengths. CONCLUSION: Our results confirm the feasibility of malaria detection by flow cytometry for semi-immune patients and extend malaria detection to nonimmune patients with low frequencies of PCM. High sensitivity and specificity for malaria detection were obtained.

Cell Separation↗

Postoperative pulmonary perfusion defects: their natural history, origin and significance.

Unmatched perfusion defects occur during the early postoperative period. These defects can persist until the tenth postoperative day and their presence is not related to the transfusion of blood or to peripheral thrombosis detected by the 125I-labelled fibrinogen uptake test. It is suggested that prophylactic agents against deep venous thrombosis should be evaluated by using a combination of krypton ventilation-perfusion lung scans and 125I-labelled fibrinogen leg scans.

Adult↗

Three-color fluorescence measurements on single cells excited at three laser wavelengths.

A three-laser flow cytometer for quantitative analysis and sorting of cells and microscopic particles has been developed and evaluated using argon- and krypton-ion lasers as excitation sources. Cells stained with three fluorescent dyes having different excitation spectra enter a flow chamber where they first pass through an electronic volume sensor and then intersect three spatially separated laser beams for fluorescence excitation of bound dyes and light scatter measurements. Separate pairs of beam-shaping optics independently position and focus each beam onto the cell stream thus permitting cells to be sequentially illuminated. Fluorescence is measured by a detector that employs a single collecting lens for single or multilaser excitation experiments. Fluorescence signals are processed and displayed as frequency distribution histograms using an LSI-11 computer. This instrument is described in detail with illustrative examples using cells stained for DNA content, protein, and cell surface antigens and cells that have phagocytized fluorescent microspheres.

Animals↗

A dual laser analysis of the migration of XRITC-labeled, FITC-labeled, and double-labeled lymphocytes in sheep.

Substituted rhodamine isothiocyanate (XRITC) has been used to study lymphocyte migration in sheep. After being labeled in vitro with XRITC, lymphocytes appeared in the efferent lymph of single lymph nodes with the same kinetics as cells labeled with fluorescein isothiocyanate (FITC). The recovery of intravenously injected XRITC-labeled cells was followed in lymph for several days. The kinetics and recoveries were compared with data obtained using FITC, chromium-51, and indium-111. XRITC was found to be a suitable label and, using dual laser (argon and krypton) flow cytometry, it could be analyzed simultaneously with FITC. In addition, it was possible to relabel FITC-stained cells with XRITC after they were recovered in lymph. The migratory characteristics of such double-labeled cells were not different from single-labeled cells.

Animals↗

Purification and analysis of rat hematopoietic stem cells by flow cytometry.

The monoclonal antibody OX7 recognizes an epitope expressed on the Thy-1 glycoprotein, OX22 recognizes the high molecular weight form(s) on leukocyte common antigen, and W3/13 recognized determinants found on certain sialoglycoproteins. Recently, the rat colony-forming unit spleen (CFU-S) was characterized as being OX7 upper 20% positive (OX7u20%), OX22 negative (OX22-), and W3/13 weakly positive (W3/13+). In the present study these observations have been extended to include the hematopoietic stem cell (HSC). Rat marrow cells were incubated with allophycocyanine-OX7 Fab' (APC-OX7 Fab') and phycoerythrin B-OX22 Fab' (Phy B-OX22 Fab'). The cells were sorted with a FACS-II instrument by using a Krypton laser tuned to the 530 nm spectral line for phycobiliprotein excitation. It was found that marrow cells capable of protecting lethally irradiated Lewis rats (9.5 Gy total body radiation, 0.4 Gy/min Co60) had the phenotype OXu20%, OX22-. The percentage of cells in the marrow with this phenotype was found to be 0.34 +/- 0.01 (mean +/- S.E.). Three thousand of these cells were required to rescue 50% of lethally irradiated recipients (30-d survival), while the number of unsorted bone marrow cells required was 1.05 X 10(6). Thus, a 350-fold purification of the HSC was realized. Although CFU-S copurified with HSC, purification of only 105-fold was obtained. This might indicate that purified HSC have a reduced capacity to generate splenic hematopoietic colonies. The OX7u20%, OX22- -enriched HSC population could be further divided into W3/13 dim and W3/13+ subpopulations by three-parameter immunofluorescence analysis with the use of a new optical bench arrangement.

Animals↗

Aequorea green fluorescent protein analysis by flow cytometry.

The isolation and expression of the cDNA for the green fluorescent protein (GFP) from the bioluminescent jellyfish Aequorea victoria has highlighted its potential use as a marker for gene expression in a variety of cell types (Chalfie et al.: Science 263: 802-805, 1994). The longer wavelength peak (470 nm) of GFP's bimodal absorption spectrum better matches standard fluorescein filter sets; however, it has a considerably lower amplitude than the major absorption peak at 395. In an effort to increase the sensitivity of GFP with routinely available instrumentation, Heim et al. (Nature 373:663-664, 1995) have generated a GFP mutant (serine-65 to threonine; S65T-GFP) which possesses a single absorption peak centered at 490 nm. We have constructed this mutant in order to determine whether it or wild-type GFP (wt-GFP) afforded greater sensitivity when excited near their respective absorption maxima. Using the conventionally available 488 nm and ultraviolet (UV) laser lines from the argon ion laser as well as the 407 nm line from a krypton ion laser with enhanced violet emission, we were able to closely match the absorption maxima of both the S65T and wild-type forms of Aequorea GFP and analyze differences in fluorescence intensity of transiently transfected 293 cells with flow cytometry. The highest fluorescence signal was observed with 488 nm excitation of S65T-GFP relative to all other laser line/GFP pairs. The wt-GFP fluorescence intensity, in contrast, was significantly higher at 407 nm relative to either 488 nm or UV. These results were consistent with parallel spectrofluorometric analysis of the emission spectrum for wt-GFP and S65T-GFP. The relative contribution of cellular autofluorescence at each wavelength was also investigated and shown to be significantly reduced at 407 nm relative to either UV or 488 nm.

Base Sequence↗

Discrimination of the Hoechst side population in mouse bone marrow with violet and near-ultraviolet laser diodes.

BACKGROUND: Discrimination of stem cells with flow cytometric analysis of Hoechst 33342 efflux by the ABCG2 transporter (termed the Hoechst side population, or SP technique) is a valuable methodology for identifying bone marrow progenitors enriched with stem cells. Unfortunately, it requires a ultraviolet (UV) laser source, usually necessitating an expensive and maintenance-intensive argon- or krypton-ion gas laser on a large-scale cell sorter. In this study, we evaluated the ability of recently available violet and near-UV laser diodes to discriminate Hoechst SP on smaller cuvette-based flow cytometers. METHODS: Violet laser diodes (emitting at 408 and 401 nm) and a near-UV laser diode (emitting at 370 nm) were mounted on a BD Biosciences LSR II and evaluated for their ability to discriminate Hoechst SP in murine bone marrow. RESULTS: The violet laser diodes discriminated the Hoechst SP, but with poorer resolution than with the standard UV gas laser on a large-scale cell sorter. The near-UV laser diode, in contrast, gave excellent Hoechst SP resolution. CONCLUSIONS: These evaluations indicated that near-UV laser diodes give excellent Hoechst SP resolution on cuvette-based instruments. As the next generation of cell sorters integrate cuvette-based cell interrogation into conventional jet-in-air cell separation, these laser sources should become applicable for analysis and physical separation of Hoechst SP cells.

Animals↗

Violet laser diodes in flow cytometry: an update.

INTRODUCTION: In previous studies we and others have demonstrated the usefulness of violet laser diodes (VLDs) as replacement laser sources for krypton-ion lasers on stream-in-air cytometers. Previously available VLDs had a maximum available power of less than 25 mW; this was sufficient for excitation of densely labeled cell surface antigens using fluorochromes such as Cascade Blue or Pacific Blue, but may have been insufficient for applications requiring higher levels of photon saturation, such as low-level expression of Cyan Fluorescent Protein (ECFP) in CFP-YFP FRET applications. In this follow-up study, we have tested more powerful VLDs emitting at 55 mW, and a beam-merged dual module VLD with 100 mW combined output, for their ability to excite a variety of violet-excited fluorochromes, including CFP. METHODS: A dual module VLD (two linear polarized VLDs with their beams merged by a polarized beam combiner) emitting at 404 nm was mounted on a BD FACSVantage DiVa stream-in-air cytometer. The individual polarized 55 mW beams or the 100 mW combined beams were used to analyze PBMCs labeled with the violet-excited probes Cascade Blue, Alexa Fluor 405, Cascade Yellow and Pacific Orange dyes. Violet-excited fluorescent microsphere mixtures with decreasing fluorescence levels were also used to detect the minimum sensitivity threshold and precision of these lasers. VLD excitation on a gel-coupled cuvette flow cytometer was used as a sensitivity baseline. RESULTS: The dual module 100 mW VLD gave both sensitivity and precision levels approaching that observed for lower-power sources on a cuvette cytometer. Single polarized VLD modules at 55 mW gave slightly decreased sensitivity for the microspheres standards and all the tested fluorochromes compared to the 100 mW source. CONCLUSIONS: While 55 mW laser sources performed adequately in the stream-in-air format, increasing the power to 100 mW did give a small but detectable increase in instrument sensitivity. This sensitivity level approached that of cuvette systems.

Animals↗

In vivo use of oligonucleotides to inhibit choroidal neovascularisation in the eye.

BACKGROUND: We have previously demonstrated the in vivo uptake of oligonucleotides in the rat eye and have continued with experiments to look at the effectiveness of targeted oligonucleotide sequences. Vascular endothelial growth factor (VEGF) is correlated with new blood vessel formation and has been implicated in numerous eye diseases characterised by abnormal blood vessel proliferation. An oligonucleotide targeted to the VEGF sequence was examined for its effect on VEGF production in vitro and the development of choroidal neovascularisation in vivo in the eye. METHODS: A series of sequences were assessed in an in vitro screening system using retinal pigment epithelial (RPE) cells to demonstrate a reduction in VEGF. A targeted sequence was further investigated using an animal model of choroidal neovascularisation where a krypton laser was used to produce a wound healing response in the choroid and retina. The oligonucleotide was injected into the vitreous and the development of choroidal neovascularisation assessed using fluorescein angiography. RESULTS: The targeted sequence was shown in vitro to downregulate the VEGF produced by RPE cells grown under hypoxic conditions and when injected into laser treated eyes was shown to be preferentially taken up in the laser lesion. Fluorescein angiography demonstrated that the test oligonucleotide was successful in reducing laser-mediated choroidal neovascularisation. CONCLUSIONS: A sequence corresponding to the 5'UTR of the VEGF gene has provided encouraging results for the treatment of neovascularisation.

Animals↗

Ultraviolet laser ablation of skin: healing studies and a thermal model.

We have followed the course of healing of incisions made with the krypton-fluoride excimer laser. Incisions were made in guinea pig skin, in vivo, under identical conditions of irradiation. The progressive healing of these incisions was followed over the course of 3 weeks. We noted excellent healing with re-epithelialization, and the re-formation of collagen fibers with minimal fibrosis. We present a simple thermal model for ablation of tissue by a short pulse of strongly absorbed laser radiation.

Animals↗

Photodynamic activity of liposome-delivered Cd-texaphyrin using tumor-bearing nude mice.

Photodynamic effects in bladder-tumor bearing nude mice induced by a krypton ion laser (752.5 nm) after i.v. application of liposome-delivered cadmium texaphyrin were investigated. Cd-texaphyrin possesses strong absorption transitions in the far red spectral region (around 760 nm) and a high quantum efficiency of singlet oxygen production. No therapeutic effects were obtained using irradiation 24 hours after administration of the sensitizer, whereas phototreatment 2 hours after application led to significant tumor reduction. This corresponds well with studies on fluorophore-labeled liposomes indicating highest tumor accumulation 1-2 hours after administration. However, the induced cytotoxic effects were lower than those of HpD.

Animals↗

Fluorescence energy-transfer cyanine heterodimers with high affinity for double-stranded DNA. II. Applications to multiplex restriction fragment sizing.

Energy-transfer cyanine dyes, a thiazsole orange-thiazole-indolenine (butylTOTIN) and a thiazole orange-thiazole blue heterodimer (pentylTOTAB), form high-affinity complexes with double-stranded (ds)DNA with donor fluorescence (lambdaF(max)527 nm) quenched >90% and with acceptor fluorescence emission above 650 nm (S. C. Benson, Z. Zeng, and A. N. Glaser (1995) Anal. Biochem. 231, 247-255). After separation by agarose gel electrophoresis, bands of precomplexed dsDNA-dye restriction fragments containing 10 pg of dsDNA are readily detected with a laser-excited confocal-fluorescence gel scanner (R. A. Mathies et al. (1994) Rev. Sci. Instrum. 65, 807-812) following donor excitation at 488 nm (argon ion laser) or direct acceptor excitation at 647 nm (krypton ion laser). Accurate two-color multiplex sizing of restriction fragments is obtained with 488-nm excitation with dsDNA fragments precomplexed with thiazole orange dimer (TOTO) as unknowns (detected at 500-565 nm, green channel) and dsDNA fragments stained with the energy-transfer cyanine dyes (detected at 645-750 nm, red channel) as internal standards. There is negligible cross talk of fluorescence between the red and green channels and no significant dye migration in mixtures of prelabeled standard and unknown fragments.

DNA↗