Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Microfluidic handling of PCR solution and DNA amplification on a reaction chamber array biochip.

A microfluidic biochip for conducting an array of polymerase chain reaction (PCR) simultaneously was fabricated to understand the microfluidic loading process of PCR solution into microfabricated glass reaction chambers. The geometrical factors of the microfluidic structure, including the shape and depth of the microchamber, shape and size of the microchannels were investigated on the formation of air bubbles trapped within the microchamber during the PCR solution loading process. Furthermore, the effects of surface properties of the microfluidic structure, including hydrophilicity of the microchamber and inlet channel, and hydrophobicity of the outlet channel, on the loading of PCR solution, especially on the formation of air bubbles were studied. As a result, the surface wetting property of the microchamber was found to be the main reason for the formation of the air bubbles inside the microchamber during the loading of PCR solution in the biochips. A solution to avoid the air trapping has been proposed and investigated.

DNA↗

Quantitative measurement and control of oxygen levels in microfluidic poly(dimethylsiloxane) bioreactors during cell culture.

Microfluidic bioreactors fabricated from highly gas-permeable poly(dimethylsiloxane) (PDMS) materials have been observed, somewhat unexpectedly, to give rise to heterogeneous long term responses along the length of a perfused mammalian cell culture channel, reminiscent of physiologic tissue zonation that arises at least in part due to oxygen gradients. To develop a more quantitative understanding and enable better control of the physical-chemical mechanisms underlying cell biological events in such PDMS reactors, dissolved oxygen concentrations in the channel system were quantified in real time using fluorescence intensity and lifetime imaging of an oxygen sensitive dye, ruthenium tris(2,2'-dipyridyl) dichloride hexahydrate (RTDP). The data indicate that despite oxygen diffusion through PDMS, uptake of oxygen by cells inside the perfused PDMS microchannels induces an axial oxygen concentration gradient, with lower levels recorded in downstream regions. The oxygen concentration gradient generated by a balance of cellular uptake, convective transport by media flow, and permeation through PDMS in our devices ranged from 0.0003 (mg/l)/mm to 0.7 (mg/l)/mm. The existence of such steep gradients induced by cellular uptake can have important biological consequences. Results are consistent with our mathematical model and give insight into the conditions under which flux of oxygen through PDMS into the microchannels will or will not contribute significantly to oxygen delivery to cells and also provide a design tool to manipulate and control oxygen for cell culture and device engineering. The combination of computerized microfluidics, in situ oxygen sensing, and mathematical models opens new windows for microphysiologic studies utilizing oxygen gradients and low oxygen tensions.

Animals↗

Three-dimensional modeling of transport of nutrients for multicellular tumor spheroid culture in a microchannel.

The growth dynamics of avascular tumors in a microchannel bioreactor is investigated. A three-dimensional flow and nutrient transport model, incorporating the multicellular tumor spheroid (MTS) growth model, has been developed to study the influence of nutrients (oxygen and glucose) supply and distribution on the MTS growth. Numerical simulations based on the EMT6/Ro tumor cells show that the continuous-flow perfusion is more efficient to deliver nutrients to the MTS than the diffusion-only static culture. It is further demonstrated that as long as there is bulk flow, the growth of a single tumor spheroid at the early stage is insensitive to the flow velocity and the channel size. For multiple tumor spheroids in the same microchannel, however, increasing the perfusion velocity can improve the nutrient environment for the disadvantageous downstream tumor spheroid. The flow shear stress exerting on the MTSs in the current microchannel bioreactor is estimated to be far below the critical value to affect the MTS growth, which means that there is still much room for increasing perfusion velocity to satisfy the higher nutrient requirement by the growing tumor spheroids.

Animals↗

A rapid DNA digestion system.

This paper presents a novel microfluidic DNA digestion system incorporating a high performance micro-mixer. Through the appropriate control of fixed and periodic switching DC electric fields, electrokinetic forces are established to mix the DNA and restriction enzyme samples and to drive them through the reaction column of the device. The experimental and numerical results show that a mixing performance of 98% can be achieved within a mixing channel of length 1.6 mm when a 150 V/cm driving voltage and a 5 Hz switching frequency are applied. The relationship between the mixing performance, switching frequency, and main applied electric field is derived. It is found that the optimal switching frequency depends upon the magnitude of the main applied electric field. The successful digestion of lambda-DNA using Eco RI restriction enzyme is demonstrated. The DNA-enzyme reaction is completed within 15 min in the proposed microfluidic system, compared to 50 min in a conventional large-scale system. Hence, the current device provides a valuable tool for rapid lambda-DNA digestion, while its mixer system delivers a simple yet effective solution for mixing problems in the micro-total-analysis-systems field.

Bacteriophage lambda↗

Sequestration electrochemistry: the interaction of chlorpromazine and human orosomucoid.

A simple and rapid method is presented for determination of the association constants and stoichiometries describing ligand macromolecule interactions. Based on flow injection analysis and electrochemical detection by amperometry, the only requirements for direct measurements are that the ligand have redox properties and that these properties change upon binding to the macromolecule. Bound ligand may then be measured in the presence of free ligand. Detection limits are of the order of 2 pmol of ligand or less, a level that should provide access to previously unmeasurable systems. For the exemplary system, chlorpromazine and human orosomucoid, K0ass was determined as 0.39 X 10(6) M-1 with 0.76 chlorpromazine binding sites of this affinity per orosomucoid molecule.

Binding Sites↗

Flow-injection binding assays: a way to increase the speed in binding analyses.

A flow-injection analysis system was equipped with a small column containing immobilized concanavalin A. Pulses containing glucosides or glycoproteins were passed over the column, the lectin bound the carbohydrates. By using horseradish peroxidase as a labeled carbohydrate and letting it compete with other glucosides or mannosides a competitive binding assay for the latter was set up. When the enzyme activity had been evaluated, the column was rinsed and reconditioned, allowing a new assay to be run. To speed up the assay, substrates for the enzyme marker, peroxidase, were present in the perfusing buffer. A computerized evaluation of the absorbance peak allowed the time of the assay cycle to be reduced to 70 s. The sensitivity of this binding assay was fully comparable with those reported for other systems using the same reactants.

Antibodies↗

Aminoacylase I from hog kidney: anion effects and the pH dependence of kinetic parameters.

The hydrolysis of acetylamino acids by highly purified hog kidney aminoacylase I (N-acylamino acid amidohydrolase, EC 3.5.1.14) was investigated using flow injection analysis to determine reaction rates. We show that the distinctly bell-shaped pH versus activity profiles observed in previous studies do not reflect protonic equilibria in the enzyme, but were created by buffer effects. At low pH, anions such as phosphate, nitrate or chloride markedly increase Km. These effects are reversed at higher pH. In zwitterionic 'Good' buffers (Mes, Mops, and Bicine), maximal velocities are almost independent of pH between 6.5 and 9 for all substrates studied (Ac-LAla, Ac-LGlu, Ac-LMet, Ac-LPhe). Below pH 6.5, the catalytic constants decrease with pH, apparently due to the protonation of a carboxylate with a pKa of 5.5-6. The pH dependence of Km markedly varies among different substates. We conclude that the observed profiles all result from the dissociation of an active-site residue with a pKa of 8-8.5, which we tentatively identify as an active-site cysteine residue. A working model of aminoacylase catalysis is presented that accounts for most of the known facts.

Amidohydrolases↗

Pollutants in drinking water and waste water.

Extracts of drinking water and effluents from municipal and industrial sewage treatment plants were analysed by gas chromatography-mass spectrometry and by high-performance liquid chromatography combined with ultraviolet and/or mass spectrometric detection. After column chromatography or flow-injection analysis bypassing the analytical column, ionization was performed by a thermospray interface. Identification of the pollutants was carried out by tandem mass spectrometry, generating daughter-ion spectra by collision-induced dissociation. Most pollutants in drinking water and in the effluents of waste water treatment plants are surface-active compounds of anthropogenic origin or their biochemical degradation products. Difficulties encountered during separation, detection and identification are presented and discussed and techniques for solving these problems are proposed.

Chromatography, Gas↗

Uses of beta-galactosidase tag in on-line monitoring production of fusion proteins and gene expression in Escherichia coli.

A simple method for monitoring and quantifying automatically the production by fermentation of beta-galactosidase fusion proteins, making use of the remaining activity of the beta-galactosidase part, is considered. A hybrid protein carrying the major antigenic domain of foot-and-mouth disease virus C1 joined at the N-terminus of beta-galactosidase has been expressed in Escherichia coli. The yield of the chimeric protein has been monitored by flow injection analysis (FIA) during batch fermentations at laboratory scale, and a high correlation between values of product concentration from FIA and from immunological quantizations has been obtained. Because of the possibility of employing FIA in large-scale experiments, and the high sampling frequency, versatility, and reproducibility offered by this method, we propose FIA as a general, simple, quick, flexible, and reliable instrument for both monitoring the yield of recombinant proteins produced industrially, and performing basic research at laboratory scale.

Aphthovirus↗

On-line chemiluminescence assay using FIA and fiber optics for urinary and blood glucose.

A chemiluminescence fiber optic system coupled to flow injection analysis (FIA) and ion exchange chromatography has been developed for determining glucose in blood and urine. Immobilized glucose oxidase acted on beta-D-glucose to produce hydrogen peroxide, which was then reacted with luminol in the presence of ferricyanide to produce a light signal. Endogenous ascorbic acid and uric acid present in urine or blood samples were effectively retained by an upstream acetate anion exchanger. In addition, acetaminophen could also be adsorbed by this ion exchanger. The detection system exhibited a sensitivity of 1.315 +/- 0.044 RU microM-1 for glucose with a minimum detection level of 1 microM. When applied for the determination of urinary and blood glucose levels, the results obtained compared well with those of the reference hexokinase assay. Immobilized glucose oxidase was reused for over 500 analyses without losing its original activity. A conservative estimate for the reuse of the acetate ion exchange column was about 100 analyses.

Adult↗

Development of a gas diffusion FIA system for on-line monitoring of ethanol.

A flow injection analysis (FIA) system for on-line monitoring of ethanol in cultivation media was developed, which combines the selectivity of a gas diffusion membrane with the substrate specificity of immobilized alcohol oxidase (AOD). The optimization of membrane material and immobilized enzyme was performed using different FIA modes such as dual detection and dual injection. A simple modification of a polypropylene membrane with silicone enabled a very flexible adjustment of the linear range for alcohol detection between 0.0006 and 60% (v v-1). The ethanol content of cultivation media could be determined continuously with a frequency of 120-180 samples per hour with an excellent correlation to gas chromatographic analysis (r = 0.9996). The relative standard deviation for 10 successive injections was lower than 0.5%.

Alcohol Oxidoreductases↗

Enzyme sensor-FIA-system for on-line monitoring of glucose, lactate and glutamine in animal cell cultures.

Enzyme sensors for glucose, lactate and glutamine were connected via flow-injection analysis (FIA) devices to two different bioprocesses. They were used for on-line process control of perfused bioreactor systems containing mammalian cell lines producing a monoclonal antibody and recombinant interleukin-2. The biosensor system gives direct access to important process data which can be used as control parameters for long term cell cultivation systems.

Animals↗

Comparison of different biosensor systems suitable for bioprocess monitoring.

To achieve effective bioprocess monitoring, sensing systems are required which are suitable for an on-line determination of substrates, inhibitors, nutrients or products. Such devices may utilise biochemical principles, i.e. the specific interaction of biochemical receptors with their surroundings. They can be constructed either as in situ sensors or as flow-through sensors connected to the process via sampling devices. Hence, characteristic features of an in situ glucose electrode are described, e.g. analytical range, sensitivity and stability. The sensor was based on mediated electron transfer from the enzyme glucose oxidase to the graphite electrode, the mediators being tetrathiafulvalene (TTF) or dimethylferrocene (DMF). Additionally, various flow injection analysis (FIA) systems based on oxidases, which were immobilised either on controlled pore glass or in a membrane, were characterised with respect to analytical ranges and sensitivities and applied to glucose, lactate and glutamate determinations in off-line samples taken from an animal cell cultivation.

Biosensing Techniques↗

Derivatization of thiol-containing compounds.

The determination of thiol-containing compounds in biological fluids is important in biochemistry and clinical chemistry. In this paper, derivatization reagents for thiols are reviewed with respect to their reactivity, selectivity, spectroscopic characteristics and their applicability especially to high-performance liquid chromatography. Derivatization used in ultraviolet and electrochemical detection. The derivatization reagents contain a functional group, e.g. an N-substituted maleimide, active halogen or aziridine, which react with the thiol group. Derivatization for use in flow injection analysis, thin-layer chromatography or gas chromatography-mass spectrometry is also described.

Chromatography, High Pressure Liquid↗

Sensitive flow-injection method with peroxyoxalate chemiluminescence detection combined with preparative high-performance liquid chromatography for determination of choline-containing phospholipids in human serum.

A sensitive and rapid flow-injection analysis (FIA) of total choline-containing phospholipids (PLs) and a selective FIA method for the class assay of choline-containing PLs combined with preparative HPLC were described. The FIA method is based on peroxyoxalate chemiluminescence (PO-CL) detection of hydrogen peroxide enzymatically formed from choline-containing PL. The linear standard curves were obtained up to 1 nmol/20-microliters injection (r > 0.999) with the detection limits of 1.3-1.6 pmol at a signal-to-noise ratio of 2. The total amounts of choline-containing PLs in human serum were ranged from 1.63 to 3.19 mg/ml. The HPLC separation of choline-containing PLs was achieved with an aminopropyl-modified silica gel column using a mixture of acetonitrile-methanol-10 mM ammonium phosphate buffer pH 5.8 as eluent. The eluate corresponding to each choline-containing PL was collected, evaporated, dissolved in 0.1% Triton X-100 aqueous solution, and then injected into FIA system. The FIA method combined with preparative HPLC was applied to the assay of human serum.

Choline↗

Flow injection extraction applied to dissolution rate studies of felodipine tablets.

A flow injection analysis (FIA) extraction method has been developed for the analysis of felodipine tablets in connection with dissolution rate testing. The water-soluble oxidation product of felodipine, a pyridine derivative, was extracted into chloroform and measured at 275 nm spectrophotometrically. The FIA-extraction method has been compared with the present liquid chromatographic (LC) method. The sampling rate for the FIA-extraction (60 samples h-1) is 5 times higher than for the LC method. The FIA-extraction method has a standard deviation of 1% for both standards and samples which is the same as for the LC method.

Chloroform↗

FIA determination of chlorhexidine by means of the precipitation with Cu(II).

The determination of chlorhexidine in pharmaceutical formulations is carried out using flow injection analysis (FIA) with measurement by atomic absorption spectrometry (AAS). The method is based on the formation of a copper-biguanide complex precipitate when the sample is injected into an ammoniacal copper solution. The precipitate is retained on a plastic or paper filtering device. A nitric acid stream dissolves the precipitate and carried the Cu(II) to the AAS detector. The chlorhexidine is determined over the range 5-20 ppm. The influence of interfering substances is investigated.

Biguanides↗

A chemiluminescence fiber-optic biosensor system for the determination of glutamine in mammalian cell cultures.

A chemiluminescence fiber-optic biosensor system has been developed for determining glutamine in hybridoma cell cultures producing monoclonal antibodies against viral surface antigens. Glutaminase and glutamate oxidase (GLO) were immobilized onto aminopropyl glass beads via glutaraldehyde activation separately and packed in a column. Two separate columns containing immobilized GLO and catalase were placed upstream to eliminate endogenous glutamate. In the presence of ferricyanide, luminol reacted with hydrogen peroxide released from the enzymatic reactions to produce a chemiluminescence (CL) light signal which was detected and quantitated with a fiber-optic system. In combination with flow injection analysis it was possible to process samples virtually identically, thus avoiding difficulties in reproducing the CL signal. There was an excellent linear relationship between the CL response and standard glutamine concentration in the range 10(-6) to 10(-3) M. A complete analysis could be performed in 2 min including sampling and washing. Each immobilized enzyme column was stable for at least 300 repeated analyses without any loss of activity. When the biosensor system was used for the determination of glutamine in spent mammalian cell cultures, the values obtained compared well with those of high-performance liquid chromatography, thus validating the applicability of the CL fiber-optic system.

Animals↗