Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DEXTERITY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46Linked to original sources

Early motor development from partially ordered neural-body dynamics: experiments with a cortico-spinal-musculo-skeletal model.

Early human motor development has the nature of spontaneous exploration and boot-strap learning, leading to open-ended acquisition of versatile flexible motor skills. Since dexterous motor skills often exploit body-environment dynamics, we formulate the developmental principle as the spontaneous exploration of consistent dynamical patterns of the neural-body-environment system. We propose that partially ordered dynamical patterns emergent from chaotic oscillators coupled through embodiment serve as the core driving mechanism of such exploration. A model of neuro-musculo-skeletal system is constructed capturing essential features of biological systems. It consists of a skeleton, muscles, spindles, tendon organs, spinal circuits, medullar circuits (CPGs), and a basic cortical model. Through a series of experiments with a minimally simple body model, it is shown that the model has the capability of generating partially ordered behavior, a mixture of chaotic exploration and ordered entrained patterns. Models of self-organizing cortical areas for primary somatosensory and motor areas are introduced. They participate in the explorative learning by simultaneously learning and controlling the movement patterns. A scaled up version of the model, a human infant model, is constructed and put through preliminary experiments. Some meaningful motor behavior emerged including rolling over and crawling-like motion. The results show the possibility that a rich variety of meaningful behavior can be discovered and acquired by the neural-body dynamics without pre-defined coordinated control circuits.

Behavior↗

Inert gas and raised pressure: evidence that motor decrements are due to pressure per se and cognitive decrements due to narcotic action.

The psychomotor and cognitive abilities of experienced professional divers participating in training and experimental dives in a hyperbaric chamber were investigated during experiments at high ambient pressure of either air or hydrogen-helium-nitrogen-oxygen mixtures. Decrements in psychomotor ability were not as large as decrements in cognitive ability: manual dexterity was 2-16%, number ordination 4-46% below control. To determine the respective roles of inert gases and pressure per se, the data were compared with lipid solubility theories of narcosis. This analysis indicated that impairment of cognitive ability was a consequence of the narcotic action of the inert gases, whereas impairment of motor ability was a consequence of the raised pressure per se.

Adult↗

Neuropsychological performance in low birth weight preschoolers: a population-based, controlled study.

UNLABELLED: The aim was to evaluate neuropsychological performance and its pre-, and perinatal predictors in low birth weight (LBW) preschool children. A population-based sample of 137 5-year-old children with birth weights less than 2000 g and without major handicaps was compared with a random sample of 152 normal birth weight term controls. Main assessment tools were all subscales from the Wechsler Preschool and Primary Scale of Intelligence Revised, subscales from the Illinois Test of Psycholinguistic Abilities and tests of manual dexterity and figure copying. The LBW children showed significantly lower mean scores compared to controls on tests of visuo-spatial and visuo-motor abilities, but were comparable to controls in other areas, confounding parental factors were controlled for. 14 of the LBW children, there were signs of maternal chorio-amnionitis. Twelve of these had premature rupture of membranes lasting more than 24 h. These 14 children had a mean performance IQ of 87 (SD 5) compared to 100 (SD 15) for the LBW children without maternal signs of chorio-amnionitis (P = 0.001). Having a small head circumference at birth was a less powerful, but statistically significant predictor of impaired performance. CONCLUSION: Low birth weight is associated with impaired performance on visuo-spatial and visuo-motor tasks. Signs of maternal chorio-amnionitis and a small head circumference at birth may be risk factors for such impairment.

Case-Control Studies↗

Neurological outcome in adult patients with early-treated phenylketonuria.

UNLABELLED: Due to the observation of severe neurological symptoms in single patients as well as brain imaging, neuropsychological and neurophysiological abnormalities, the long-term prognosis of treated phenylketonuria is still under discussion. We investigated the neurological outcome of 57 (24 male, 33 female) patients with phenylketonuria (diet onset < 3 months) at a mean age of 23.6 (17-33) years in comparison to control subjects. Methods used were a clinical-neurological examination, tests for fine motor abilities, IQ test (WAIS-R), a neuropsychological attention task and MRI (30 patients only). Tremor was increased in the patients (28%) compared to controls (15%). Fine motor abilities were significantly reduced in three areas: hand-wrist steadiness, finger-hand dexterity and hand-wrist speed. Tremor as well as reduced fine motor skills were not associated with treatment-related variables, e.g. diet onset, strictness of biochemical control or amount of MRI white matter change. IQ was lower in patients (mean 97.6) compared to matched control subjects (mean 105.5). IQ at 12 years was correlated with biochemical control from birth up to the age of 12 and remained stable up to adult age, independent of biochemical control after 12 years of age. In contrast to the other outcome parameters, the performance in a neuropsychological attention task was influenced by the concurrent plasma phenylalanine concentration. Specific late-onset neurological impairment was not identified in this sample of early-treated adults with phenylketonuria. CONCLUSION: Careful neurological investigation revealed subtle symptoms of brain damage even after early-initiated treatment in adult patients with phenylketonuria. At present it cannot be excluded that further neurological deterioration could emerge later in life. Thus, patients with phenylketonuria - either on or off diet - should be monitored throughout life.

Adolescent↗

Histological changes of the dopaminergic nigrostriatal system in aging.

Although the maximum human lifespan has not increased in recent history, average life expectancy has risen dramatically since the beginning of the last century. Lengthening of lifespan has little merit if the quality of life is not preserved. In the elderly, the decline in memory and cognitive abilities is of great concern, as is motor weakening, which increases with age. The dopaminergic system mediates some aspects of manual dexterity, in addition to cognition and emotion, and may be especially vulnerable to aging. Therefore, the aging of this system has both clinical and vocational aspects. This review includes studies quantitating age-related changes of the nigrostriatal system, with emphasis on the use of stereological methods, and provides tables of stereological studies performed in the nigrostriatal system.

Aging↗

Learning curve for unilateral endoscopic totally extraperitoneal (TEP) inguinal hernioplasty.

BACKGROUND: Performance of endoscopic totally extraperitoneal inguinal hernioplasty (TEP) requires specialized anatomical knowledge and surgical dexterity. The present study was undertaken to evaluate the learning curve for a general surgeon to master the technique of TEP in the absence of an experienced supervisor. METHODS: A retrospective analysis of the first 120 consecutive unilateral TEPs was performed. Medical records were reviewed to evaluate demographic features, perioperative outcome, and follow-up results. The study population was divided into six consecutive groups of 20 patients. Clinical data were compared among the groups to evaluate the impact of operative experience on perioperative outcome. RESULTS: Operative time was the only clinical parameter that showed significant improvement with experience; it reached a plateau value of <1 h after the fourth group. Conversions to transabdominal and open approaches were required in only one patient in groups 1 and 6, respectively. Comparison of demographic features, hernia types, postoperative morbidity rates, length of hospital stay, and number of days to resume normal activities showed no significant differences among the groups. All complications were minor and resolved uneventfully. No recurrence was detected during follow-up. CONCLUSIONS: The learning curve for unilateral TEP by a general surgeon peaked after performing 80 procedures. In most cases, unilateral TEP can be accomplished safely within 1 h. Even during the learning process, TEP carries a low morbidity and conversion rate.

Adult↗

What is the value of telerobotic technology in gastrointestinal surgery?

BACKGROUND: Although telerobotic technology has entered clinical application, its value for gastrointestinal surgery is unclear. Our objective was to evaluate the performance characteristics of telerobotically assisted laparoscopic cholecystectomy (TALC). METHODS: All TALCs performed using the da Vinci Surgical System between January 2000 and September 2001 at a tertiary academic medical center were analyzed. RESULTS: For this study, 20 patients (80% female) with a mean age of 47 +/- 4 years underwent TALC. All had symptomatic cholelithiasis, and all had successful TALC results without complications or need for conversion to conventional laparoscopic cholecystectomy (CLP). The mean procedure time was 152 +/- 8 min. The procedures were performed by one of three staff surgeons experienced in laparoscopic surgery who had training in telerobotic surgery. The perceived advantages of TALC over CLP included easier tissue dissection, enhanced dexterity, and stimulated interest in biliary surgery. The disadvantages included increased operating time and lack of tactile feedback. CONCLUSIONS: The TALC procedure is effective and safe when performed by appropriately trained surgeons. Telerobotic technology has the potential to reinvigorate gastrointestinal surgery.

Academic Medical Centers↗

Evaluating minimally invasive surgery training using low-cost mechanical simulations.

BACKGROUND: The goal of this study was to develop, test, and validate the efficacy of inexpensive mechanical minimally invasive surgery (MIS) model simulations for training faculty, residents, and medical students. We sought to demonstrate that trained and experienced MIS surgeon raters could reliably rate the MIS skills acquired during these simulations. METHODS: We developed three renewable models that represent difficult or challenging segments of laparoscopic procedures; laparoscopic appendectomy (LA), laparoscopic cholecystectomy (LC), and laparoscopic inguinal hernia (LH). We videotaped 10 students, 12 surgical residents, and 1 surgeon receiving training on each of the models and again during their posttraining evaluation session. Five MIS surgeons then assessed the evaluation session performance. For each simulation, we asked them to rate overall competence (COM) and four skills: clinical judgment (respect for tissue) (CJ), dexterity (economy of movement) (DEX), serial/simultaneous complexity (SSC), and spatial orientation (SO). We computed intraclass correlation (ICC) coefficients to determine the extent of agreement (i.e., reliability) among ratings. RESULTS: We obtained ICC values of 0.74, 0.84, and 0.81 for COM ratings on LH, LC, and LA, respectively. We also obtained the following ICC values for the same three models: CJ, 0.75, 0.83, and 0.89; DEX, 0.88, 0.86, and 0.89; SSC, 0.82, 0.82, and 0.82; and SO, 0.86, 0.86, and 0.87, respectively. CONCLUSIONS: We obtained very high reliability of performance ratings for competence and surgical skills using a mechanical simulator. Typically, faculty evaluations of residents in the operating room are much less reliable. In contrast, when faculty members observe residents in a controlled, standardized environment, their ratings can be very reliable.

Clinical Competence↗

Determinants of competency judgments by experienced laparoscopic surgeons.

BACKGROUND: The definitive criteria for assessing competence remain elusive. In our study, we aimed to identify the determinants of competence assessment used by individual laparoscopic surgeons. METHODS: In a blinded fashion, five laparoscopic surgeons rated 27 subjects on three laparoscopic simulations in four skill categories: clinical judgment, dexterity, serial/simultaneous complexity, and spatial orientation. The raters then assessed overall subject competence for each procedure. Point-biserial correlational analyses and cluster analyses were performed to ascertain the relationships among the various scales. RESULTS: All of the correlations between the skills' ratings and competence judgments were statistically significant ( p <.05). No skill rating was consistently more highly correlated with the competence rating. There were no distinct patterns of correlations for each rater or each procedure. One factor emerged from each cluster analysis of the skills measures. CONCLUSIONS: The results suggest that the four skills scored in the study are highly correlated with each other and are important in determining competence. The cluster analyses revealed that the surgeon raters shared a common perception of competence.

Adult↗

Robot-assisted laparoscopic intestinal anastomosis.

INTRODUCTION: Robotic telemanipulation systems have been introduced recently to enhance the surgeon's dexterity and visualization in videoscopic surgery in order to facilitate refined dissection, suturing, and knot tying. The aim of this study was to demonstrate the technical feasibility of performing a safe and efficient robot-assisted handsewn laparoscopic intestinal anastomosis in a pig model. METHODS: Thirty intestinal anastomoses were performed in pigs. Twenty anastomoses were performed laparoscopically with the da Vinci robotic system (robot-assisted group), the remaining 10 anastomoses by laparotomy (control group). OR time, anastomosis time and complications were recorded. Effectiveness of the laparoscopic anastomoses was evaluated by postoperative observation of 10/20 pigs of the robot-assisted group for 14 days and by testing mechanical integrity in all pigs by measuring passage, circumference, number of stitches, and bursting pressure. These parameters and anastomosis time were compared to the anastomoses performed in the control group. RESULTS: In all cases of the robot-assisted group the procedure was completed laparoscopically. The only perioperative complication was an intestinal perforation, caused by an assisting instrument. The median procedure time was 77 min. Anastomosis time was longer in the laparoscopic cases than in the controls (25 vs 10 min; p <0.001). Postoperatively, one pig developed an ileus, based on a herniation of the spiral colon through a trocar-port. For this reason it was terminated on the sixth postoperative day. All anastomoses of the robot-assisted group were mechanically intact and all parameters were comparable to those of the control group. CONCLUSION: Technical feasibility of performing a safe and efficient robot-assisted laparoscopic intestinal anastomosis in a pig model was repeatedly demonstrated in this study, with a reasonable time required for the anastomosis.

Anastomosis, Surgical↗

The effect of stress-inducing conditions on the performance of a laparoscopic task.

BACKGROUND: The availability of objective means for assessment of surgical skills has made it possible to evaluate the effect of adverse environmental conditions on surgical performance. METHODS: Participants performed a laparoscopic transfer task under five conditions: a simple verbal mathematical task (M), operating theatre background noise at 80 to 85 dB (N), performance as quickly as possible (T), all three stressors combined (A), and quiet conditions (Q). The effect of these conditions on performance was evaluated by using a motion analysis system and an error score. RESULTS: The study included 13 right-handed surgeons with varying levels of laparoscopic experience. There was a significant increase in the path length per movement of the right hand (p = 0.001) under T and a significant increase in the path length per movement of the left hand under M (p = 0.002), T (p = 0.01), and A (p = 0.02). A significantly higher number of errors occurred under all four stress-inducing conditions. The effect was more pronounced when all the stressors were applied in combination ( p = 0.001) followed by performance under M (p = 0.005), then T (p = 0.01) and N (p = 0.03). CONCLUSIONS: All three stressors led to impaired dexterity and an increase in the incidence of errors.

Adult↗

Robot-assisted laparoscopic choledochojejunostomy.

BACKGROUND: Endoscopic stenting is the treatment of choice for palliative relief of biliary obstruction by a periampullary tumor. If treated surgically, a choledochojejunostomy and Roux-en-Y diversion is still performed by laparotomy in a large number of cases due to technical challenges of the biliodigestive anastomosis in the laparoscopic approach. Robotic systems may enhance dexterity and vision and might therefore support surgeons in delicate laparoscopic interventions. The purpose of this study is to assess the efficacy and safety of performing a laparoscopic choledochojejunostomy and Roux-en-Y reconstruction with the aid of a robotic system. METHODS: Ten laparoscopic procedures were performed in pigs with the da Vinci robotic system and compared to 10 procedures performed by laparotomy (controls). Operation room time, anastomoses time, blood loss, and complications were recorded. The effectiveness of the anastomoses was evaluated by postoperative observation for 14 days and by measuring passage, circumference, and number of stitches. RESULTS: Operating room time was significantly longer for the robot-assisted group than for controls (140 vs 82 min, p < 0.05). The anastomoses times were longer in the robot-assisted cases but not statistically significant (biliodigestive anastomosis, 29 vs 20 min; intestinal anastomosis, 30 vs 15 min), Blood loss was less than 10 cc in all robot-assisted cases and 30 cc (10-50 cc) in the controls. In both groups, there were no intraoperative complications. In the control group, one pig died of gastroparesis on postoperative day 6. In the robot-assisted group, one pig died on postoperative day 7 due to a volvulus of the jejunum. At autopsy, a bilioma was found in one pig in the robot-assisted group. In all pigs, the biliodigestive and intestinal anastomoses were macroscopically patent with an adequate passage. Circumference and number of stitches were similar. CONCLUSION: The safety and efficacy of robot-assisted laparoscopic choledochojejunostomy was proven in this study. The procedure can be performed within an acceptable time frame.

Anastomosis, Roux-en-Y↗

Miniature robots can assist in laparoscopic cholecystectomy.

Laparoscopy reduces patient trauma but eliminates the surgeon's ability to directly view and touch the surgical environment. Although current robot-assisted laparoscopy improves the surgeon's ability to manipulate and visualize the target organs, the instruments and cameras remain constrained by the entry incision. This limits tool tip orientation and optimal camera placement. This article focuses on developing miniature in vivo robots to assist surgeons during laparoscopic surgery by providing an enhanced field of view from multiple angles and dexterous manipulators not constrained by the abdominal wall fulcrum effect. Miniature camera robots were inserted through a small incision into the insufflated abdominal cavity of an anesthetized pig. Trocar insertion and other laparoscopic tool placements were then viewed with these robotic cameras. The miniature robots provided additional camera angles that improved surgical visualization during a cholecystectomy. These successful prototype trials have demonstrated that miniature in vivo robots can provide surgeons with additional visual information that can increase procedural safety.

Animals↗

Robotic surgery training and performance: identifying objective variables for quantifying the extent of proficiency.

BACKGROUND: To understand the process of skill acquisition in robotic surgery and to allow useful real-time feedback to surgeons and trainees in future generations of robotic surgical systems, robotic surgical skills should be determined with objective variables. The aim of this study was to assess skill acquisition through a training protocol, and to identify variables for the quantification of proficiency. METHODS: Seven novice users of the da Vinci Surgical System engaged in 4 weeks of training that involved practicing three bimanual tasks with the system. Seven variables were determined for assessing speed of performance, bimanual coordination, and muscular activation. These values were compared before and after training. RESULTS: Significant improvements were observed through training in five variables. Bimanual coordination showed differences between the surgical tasks used, whereas muscular activation patterns showed better muscle use through training. The subjects also performed the surgical tasks considerably faster within the first two to three training sessions. CONCLUSIONS: The study objectively demonstrated that the novice users could learn to perform surgical tasks faster and with more consistency, better bimanual dexterity, and better muscular activity utilization. The variables examined showed great promise as objective indicators of proficiency and skill acquisition in robotic surgery.

Adult↗

Hand-assisted laparoscopic digestive surgery provides safety and tactile sensation for malignancy or obesity.

BACKGROUND: Some of the persistent problems associated with laparoscopic surgery stem from the inability of the surgeon to palpate the abdominal contents during the operation. This lack of tactile sensation can lead to poor abdominal exploration, difficulty in extracting the organs, and a relatively long operation time compared to conventional procedures. The Dexterity Pneumo Sleeve is a new device that allows the surgeon to insert his or her hand into the abdominal cavity through a small incision while preserving the pneumoperitoneum. METHODS: Recently, 13 of our patients underwent hand-assisted advanced laparoscopic surgery using this device. In this series, we had two cases of gastrectomy, two cases of gastric bypass for morbid obesity, two Whipple cases for periampullary tumor, and seven cases of bowel resection. On the basis of this series, we were able to assess the utility of this device. RESULTS: Satisfactory pneumoperitoneum was maintained in 12 of 13 cases. The length of the skin incision was 7.8 cm on average, which was almost the same size as surgeon's glove. The device proved to be very useful for tissue retraction and abdominal exploration in all cases and for intracorporeal knot tying in some cases. CONCLUSIONS: We found that the device permitted an easier dissection, resection, and anastomosis. It also helped to decrease the operation time.

Adult↗

The 3-D monitor and head-mounted display. A quantitative evaluation of advanced laparoscopic viewing technologies.

BACKGROUND: Stereoscopic (3-D) monitors and head-mounted displays have promised to facilitate laparoscopic surgery by increasing positional accuracy and decreasing operative time. To test this hypothesis, we evaluated the performance of subjects using these displays to perform standardized laparoscopic dexterity drills. METHODS: Fifty laparoscopic novices worked within an abdominal cavity simulator using four videoscopic display configurations: (1) standard (2-D) monitor; (2) 3-D monitor; (3) 2-D head-mounted display; and (4) 3-D head-mounted display. Subjects repeated 3 standardized training exercises 2 times. We measured time to complete each drill and number of errors committed. RESULTS: Mean total times to complete all 3 drills were 455, 459, 485, and 449 sec for configurations 1-4, respectively. Mean total errors committed numbered 11.3, 10.4, 12.3, and 10.8, respectively. Neither comparison reached statistical significance (p < 0.05). When 3-D configurations were compared to 2-D configurations overall, a small but statistically significant reduction in errors was noted for 1 drill only (4.3 vs 5.0, p = 0.018). CONCLUSIONS: Three-dimensional imaging slightly reduced the number of errors committed by laparoscopic novices during one test drill; this improvement, however, was not clinically significant. Neither the 3-D monitor nor the head-mounted display decreased task performance time. Widespread adoption of this technology awaits future improvement in display resolution and ease of use.

Clinical Competence↗

Short-term effect of amantadine sulphate on motor performance and reaction time in patients with idiopathic Parkinson's disease.

In thirty patients with idiopathic Parkinson's disease (PD) we examined in a prospectively designed study the effect on motor performance and cognitive functions of amantadine sulphate, applied intravenously over a period of 14 days. Prior to the introduction of amantadine and post infusionem the motor function was measured by the Unified Parkinson Disease Rating Scale (UPDRS) and the Motor Performance Test Series (MPS); the simple and the choice reaction time were assessed using the Vienna Reaction Unit (VRU). The primary endpoint of efficacy was the change in the UPDRS part III (motor examination) after 14 days of amantadine sulphate administration compared with baseline. Secondary end-points were changes in the variables of-the MPS and VRU at the end of administration interval compared with baseline. Overall, after 14 days of intravenous amantadine administration (200mg/ day), a significant improvement was obtained in motor performance with respect to the semiquantitative motor scores of the UPDRS (p = 0.002) and the quantitative motor variables in the pertinent subtests of the MPS, reflecting precision and speed of arm-hand movement as well as manual and finger dexterity, for the right (p < 0.01) and the left hand (p < 0.05). However, all patients being viewed collectively, it was observed that there was a widely differing time delay of efficient motor response to amantadine from 4 to 9 days between individuals, whilst the quality of motor response remained stable for the follow-up period. Although simple reaction time showed no significant improvement, choice reaction time shortened significantly in less affected PD patients staging Hoehn and Yahr I to III (p < 0.05). We conclude that apart from efficacy on motor performance, amantadine sulphate - applied intravenously - has a positive effect on cognitive functions, particularly in less affected PD patients.

Adult↗

Arthritis impact measurement scales in a community-based rheumatoid arthritis population.

The objective of this study was to use the Arthritis Impact Measurement Scales (AIMS) in a community-based rheumatoid arthritis (RA) population to describe the patient population, analyse health status changes and predict survival. The AIMS was assessed in 91 RA patients in a community-based RA population in Kuusamo, Northern Finland. A 5-year follow-up study was performed. The mean AIMS scores in this series of RA patients were comparable to those reported in previous studies. Dexterity correlated with disease duration. Lower extremity function was well preserved and only slightly dependent on disease duration. The AIMS scores changed for the worse in all the subscales over the follow-up period. Of all the AIMS subscale scores, poor functional status, as measured by the AIMS lower extremity function and social activity subscales, best predicted mortality.

Arthritis, Rheumatoid↗