Immunoassay of estradiol: unanticipated suppression by unconjugated estriol.

BACKGROUND: Accurate measurement of estradiol is important in clinical settings. The quality of laboratory estimations of estradiol may be assessed through external quality-assurance surveys. METHODS: Estradiol was measured by microparticle enzyme immunoassay (MEIA) and other immunoassays. Proficiency testing of medical laboratories was conducted using samples prepared from normal male human serum supplemented with exogenous estradiol and other steroid and nonsteroid hormones, and participant laboratories measured estradiol by a variety of commonly used immunoassay techniques. RESULTS: The imprecision (CV) for measurement of estradiol [100-300 ng/L (367-1102 pmol/L)] was </=22% for most analytical techniques. Greater imprecision, as high as 40% for the same concentration range, was observed for the (AxSYM) MEIA method in the proficiency testing event of September 2001. Results from this method were bimodal in distribution. We found that unconjugated estriol at concentrations >1.5 microg/L (>5.2 nmol/L) interfered with the MEIA method, leading to decreased recovery of added estradiol by up to 50%. This suppression in estradiol measurement was prevented by dilution of the specimen before measurement. Addition of unconjugated estriol gave a positive bias in some other immunoassay methods for estradiol. Poor comparability among the immunoassay methods for measurement of estradiol at clinically relevant concentrations [ approximately 60 ng/L (220 pmol/L)] was revealed. CONCLUSIONS: A negative interference of unconjugated estriol with the MEIA method is a source of error for estradiol measurement. Lack of specificity and lack of comparability among immunoassay methods for estradiol may have detrimental effects on medical practice.

Blood Specimen Collection↗

Determination of butamyrate citrate in cough preparations by derivative UV spectrophotometry and high performance liquid chromatography.

Derivative spectrophotometric procedures and an isocratic high performance liquid chromatographic method for the determination of butamyrate citrate (Sinecod, Safarol) in cough syrups have been developed. In the spectrophotometric method, direct measurement of the drug at its absorption maxima is impossible because of interference from different absorbing excipients. Extraction of butamyrate citrate was performed with n-pentane/isopropyl alcohol. Quantification was carried out through the use of 1D derivative at a trough depth of 253.6 nm where interferences from other coextracted compounds are negligible. The extraction efficiency expressed as a % recovery and precision were assessed by fortifying placebo syrup(s) with known amounts of the compound. Also, a reversed phase high performance liquid chromatographic method was used with a mobile phase containing 0.015 M aqueous tetraethylammonium hydrogen sulfate, methanol and acetonitrile 40:30:30 adjusted to pH 3.50 with ammonium hydroxide. The retention behavior of butamyrate citrate as a function of both pH and salt concentration in the aqueous portion of the mobile phase was investigated. Quantification was achieved with UV detection at 258 nm based on peak area. The HPLC method clearly separates the analyte from its degradation products derived after storage of samples under different stress conditions such as acid, alkaline, temperature, oxygen and light. The described methods were successfully applied to the determination of butamyrate citrate in commercial pharmaceutical products and in placebo syrups prepared in the laboratory with good accuracy and precision. The results of the present study show that the use of the derivatives and the HPLC procedure provide precise and sensitive methods for the determination of the compound in pharmaceutical formulations.

Antitussive Agents↗

Statistical process monitoring of WBC-reduced blood components assessed by two types of software.

BACKGROUND: Statistical process control is required for monitoring of the WBC-reduction process. This study focused on some factors that may influence the outcomes of statistical process monitoring, such as WBC-reduction technologies, the anticoagulant used, and WBC-counting technologies, by using two types of software. STUDY DESIGN AND METHODS: Data were collected from January to September 1999, before the implementation of universal WBC reduction. The effects of three major factors were investigated: methods of preparation, the addition of EDTA to the sample, and the WBC-counting technologies used (microvolume fluorimetry, flow cytometry, and Nageotte chamber). The WBC-reduction process capability was assessed by two types of software, EZQC (Gambro BCT) and NWA (Northwest Analytical). In addition, the differences between various sets of results were compared by the t test or ANOVA. RESULTS: There was no statistical difference (at the 0.05 level of significance) in WBC content when the three types of platelets in citrate samples were compared with EDTA samples. In general, the Nageotte chamber appeared to count the lowest, and microvolume fluorimetry appeared to count lower than flow cytometry. There were minor but significant methodologic differences between the software packages. However, these differences had negligible effects on the percentage of conforming components at both <1 x 10(6) and <5 x 10(6) WBCs per unit. CONCLUSION: Only the counting technologies were sufficiently different to warrant consideration. This difference may make unacceptable the interchange of results obtained from various counting methods.

Anticoagulants↗

Electrothermal vaporization system using furnace-fusion technique for the determination of lead in botanical samples by inductively coupled plasma atomic emission spectrometry.

A new approach to sample digestion, subsequent vaporization and introduction into an inductively coupled plasma atomic emission spectrometer was developed for the direct determination of lead. To each small sample cuvette made of tungsten, a mixture of a ground solid sample and powdered diammonium hydrogenphosphate was precisely weighed. The cuvette was positioned onto the tungsten boat furnace (TBF) incorporating a vaporizer. Tetramethylammonium hydroxide solution was added. Then the cuvette was heated and maintained at a wet-digestion temperature to decompose the solid sample. After digestion, the temperature was elevated to generate the analyte vapor for introduction into a plasma. Since the solid samples were wet-digested in the sample cuvettes before vaporization, they could be analyzed by using a calibration curve prepared from aqueous standard solutions. This method was applied to the determination of lead in several biological materials with satisfactory results.

Calibration↗

Sample preparation for chromatographic analysis of food.

Sampling, homogenisation and sample preparation prior to chromatographic injection of food analytes are designed to enhance accuracy and precision. The reduction of inherent errors introduced by these steps requires the analyst's attention as a matter of course. Methods and examples of minimising errors in each step are reviewed.

Chromatography↗

Determination of imipenem (N-formimidoyl thienamycin) in human plasma and urine by high-performance liquid chromatography, comparison with microbiological methodology and stability.

High-performance liquid chromatographic (HPLC) methods using ultraviolet (UV) detection have been developed for the assay of the antibiotic imipenem (N-formimidoyl thienamycin) in human plasma and urine. A reversed-phase analytical column is employed in the plasma assay method and a cation-exchange column is used in the urine assay method. Both methods use borate buffer in the mobile phase. The method of preparation of human fluid samples for HPLC injection has been optimized with respect to the stability of imipenem in aqueous buffers, in morpholine buffer--ethylene glycol stabilizer, and in urine and plasma. Preparation of the samples before injection into the HPLC systems involves deproteination/filtration of the plasma/urine samples. The open lactam metabolite and the coadministered dehydropeptidase inhibitor, cilastatin sodium, do not interfere with the 313-nm detection of imipenem in either the plasma or the urine assay. Thienamycin, the precursor of imipenem and an impurity in imipenem formulations, is separated from the drug using both of these methods. Concentrations generated from the HPLC analysis of plasma and urine samples from two healthy volunteers compare favorably with results using a microbiological assay method. Correlation of the two methods gives r greater than or equal to 0.990 for both fluids.

Anti-Bacterial Agents↗

Determination of the terfenadine metabolite azacyclonol in human serum using gas chromatography-mass spectrometry.

In this work, a method for the determination of azacyclonol, a primary metabolite of terfenadine, in human serum is described. Sample preparation is carried out by liquid-liquid extraction under basic conditions. For an efficient clean up, the analytes are back-extracted into diluted hydrochloric acid and, after alkalinization, are once again extracted into the organic phase. No derivatisation step is performed. The samples are measured by gas chromatography-mass spectrometry with good selectivity. The limit of detection is 2 ng/ml. The coefficients of variation are 12.6% at 10 ng/ml and 6.44% at 200 ng/ml in the day-to-day control measurements.

Anti-Anxiety Agents↗

Direct profiling of multiple enzyme activities in human cell lysates by affinity chromatography/electrospray ionization mass spectrometry: application to clinical enzymology.

We describe a new method for enzyme analysis using affinity capture followed by electrospray ionization mass spectrometry (ACESIMS) for the quantitative determination of the initial velocities of four heparin-modifying enzymes. These enzymes, when defective in affected children, lead to the lysosomal storage disease known as Sanfilippo syndrome. The method relies on substrates and internal standards conjugated to the molecular handle biotin via a heavy isotope-encodable, mass-adjustable linker. Reaction velocities of the Sanfilippo enzymes in a crude lysate prepared from as little as 2500 human skin fibroblasts can be determined. In addition, the ACESIMS method is widely applicable to the simultaneous analysis of multiple enzymes in a complex biological sample by a single analytical technique and will thus serve as a useful tool in basic and clinical biomedical research.

Cells, Cultured↗

Determination of platinum complexes in clinical samples by a rapid flameless atomic absorption spectrometry assay.

The frequent use of platinum (Pt) complexes in cancer chemotherapy and the application of new therapeutic options and dosing strategies have increased the need for rapid analytic procedures to determine Pt concentrations in the biologic fluids of patients. Therefore a flameless atomic absorption spectrometry method for the quantification of Pt in plasma and ultrafiltrate was developed and validated. A simple sample preparation of only one dilution step was established. Only 400 microL of whole blood was required for duplicate analysis of Pt in both matrices. The matrix-specific temperature programs took less than 75 seconds. The lower limit of quantification was 40 ng Pt/mL and 20 ng Pt/mL for plasma and ultrafiltrate, respectively. Suitable linearity could be reached using separate calibration curves for the high and low Pt concentration ranges. Recovery of Pt was complete, and there were no major stability problems. The accuracy and precision of the new method met the international criteria for the validation of bioanalytic methods. In addition, the use of different anticoagulants for clinical sampling, ultrafiltration systems, and ultrafiltration conditions were investigated. The assay has already been extensively applied to pharmacokinetic studies. In conclusion, the new Pt assay proved to be rapid, simple, sensitive, and suitable for clinical use.

Anticoagulants↗

Dicyclohexylamine-induced shift of biosynthesis from spermidine to spermine in plant protoplasts.

An improved analytical method, based on high pressure liquid chromatography, has been developed for the simultaneous determination of the polyamines and S-adenosyl-containing compounds in extracts of plant protoplasts. The method involves simple procedures for sample preparation and permits quantification of 1 picomole or less for all the compounds. This method has been used to study the effects of dicyclohexylamine, an inhibitor of plant spermidine synthase (Sindhu, R. K., S. S. Cohen 1984 Plant Physiol 74: 645-649), on biosynthesis of polyamines and 1-aminocyclopropane-1-carboxylate in protoplasts derived from Chinese cabbage leaves. Dicyclohexylamine effectively inhibits spermidine synthase in vivo. Inhibition of the synthesis of spermidine by dicyclohexylamine resulted in a stimulation of spermine synthesis, without significant effect on the synthesis of 1-aminocyclopropane-1-carboxylate. Decarboxylated S-adenosylmethionine is present in control Chinese cabbage protoplasts at approximately 10(-18) moles per cell, and dicyclohexylamine caused an increase of this metabolite of up to 10-fold in a 4-hour period. The increase in decarboxylated S-adenosylmethionine permitted an increased synthesis of spermine. These findings suggest that the availability of decarboxylated S-adenosylmethionine may be rate-limiting for the synthesis of spermine in plant protoplasts.

Journal Article↗

Comparison of five automated serum and whole blood folate assays.

Serum and whole blood folate measurements are used to establish folate deficiency. Most methods used in clinical laboratories are automated, nonistopic methods that use folate-binding protein. Linearity, imprecision, and method comparison studies, including serum and whole blood hemolysates, were performed with the Access, Advia Centaur, ARCHITECT i2000, Elecsys 2010, and IMMULITE 2000 methods. The QuantaPhase II radioassay served as the comparison method. (Proprietary information is given in the text.) The Access and IMMULITE 2000 methods had higher systematic errors in linearity studies than the other 3 methods. The imprecision of all methods was acceptable (coefficient of variation, < 10%) even at low folate concentrations with the exception of the Elecsys 2010 (coefficient of variation, 16%). Method comparison studies using serum samples revealed calibration differences between the Access and Elecsys 2010 methods and the comparison method. Method comparison studies using whole blood samples showed poorer agreement between each of the automated methods and the comparison method than was seen with serum samples. The ARCHITECT i2000 folate assay demonstrated the best analytic performance. The poor agreement seen with whole blood hemolysates likely is due to calibration differences and differences in hemolysate preparation conditions.

Blood Chemical Analysis↗

Enzyme immunoassay of thyroxin-binding globulin.

We describe a new double-antibody enzyme radioimmunoassay for thyroxin-binding globulin (TBG) in serum. A TBG-beta-D-galactosidase complex was prepared with m-maleimidobenzoyl N-hydroxysuccinimide ester. The mean analytical recovery of TBG added to serum was 99%, sample volume and TBG value were linearly related, and values for TBG determined by this method and those determined by radioimmunoassay correlated well (r = 0.98). Coefficients of variation averaged 7.6% within assay, 6.6% between assay. The measurable range of TBG in the serum was 3.3 to 52 mg/L, but higher TBG concentrations could be measured by diluting the test serum with TBG-free serum. Mean (and SD) serum TBG concentrations as determined by this method were as follows: for 20 normal subjects, 21.2 (3.7) mg/L; for 10 pregnant women, 50.1 (9.5 mg/L; and for 10 patients with TBG deficiency, not detectable.

Female↗

Comparison of three sampling and analytical methods for the determination of airborne hexavalent chromium.

A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.

Air Pollutants↗

Spectrofluorimetric determination of acetaminophen with N-bromosuccinimide.

A simple, sensitive, and selective method for determination of acetaminophen based on its oxidation using N-bromosuccinimide (NBS) to produce a highly fluorescent product. Optimization of reaction variables was carried out concerning NBS concentration, pH, temperature, reaction time, and stability time. Under optimal analytical conditions, the fluorescent intensity was measured at lambda emission. 442 nm (excitation at lambda 330 nm). The linearity range is 120-800 ng/mL with lower detection limit of 33.6 ng/mL acetaminophen. The method was applied successfully to the determination of the compound in pharmaceutical preparations, with average recovery of 100.3 +/- 2%. The method was also applied successfully to the determination of the drug in spiked plasma samples, with an average recovery of 101.2 +/- 1%. Interference effects of some compounds, present in combination with acetaminophen, were studied and the tolerance limits of these compounds were determined.

Acetaminophen↗

Analysis of the Fusarium mycotoxins fusaproliferin and trichothecenes in grains using gas chromatography-mass spectrometry.

A method is described using gas chromatography-mass spectrometry (GC-MS) for the simultaneous detection of the Fusarium mycotoxins fusaproliferin and seven trichothecenes from grains. Sample purification of the raw extract was carried out with commercial solid phase extraction columns, and the recovery of the more polar analytes was increased by rinsing the column with acetonitrile. A significant matrix effect was found for the analysis of fusaproliferin and trichothecenes; thus, the calibrants should be prepared in a blank matrix. The response was linear in the range used. The mean recovery for fusaproliferin was 60.4 or 62.9%, depending on the spiking level. With respect to the trichothecenes, the recovery was generally higher (70.2-125.3%). The method proved to be repeatable for the analysis of fusaproliferin and trichothecenes. The limit of detection for fusaproliferin in the blank matrix mixture was 50 microg/kg, and that for trichothecenes was 5-15 microg/kg. Thirty-eight Finnish grain samples were analyzed for fusaproliferin and trichothecenes with the method developed. Fusaproliferin was not detected in any of the samples. The mean levels of deoxynivalenol, 3-acetyldeoxynivalenol, nivalenol, HT-2 toxin, and T-2 toxin in Finnish grain samples were 272, 17, 150, 40, and <20 microg/kg, respectively.

Edible Grain↗

Isotachophoresis of CSF proteins in gel tubes especially gammaglobulins. An analytical and preparative technique for high-separation of CSF proteins.

An isotachophoretic method using polyacrylamide gel (PAG-ITP) in a simple disc electrophoretic equipment with plastic tubes containing the gels, was elaborated and especially designed for studying the gammaglobulins in CSF and serum from control subjects and patients with neurological disorders, especially known or probable MS. The device and the ITP system used, including leading and terminating electrolytes and spacer substances, dividing the gammaglobulins in a reproducible way, are described. No cooling of the gel tubes was needed. The sample volumes varied between 5--500 microliters, and the separation time was 1.5--3.0 h. CSF from patients with verified or probable MS revealed characteristic, increased low-mobility gammaglobulin fractions. Using other ITP systems, such as other spacer compositions, the anodic proteins can also be studied in more detail. PAG-ITP in gel tubes is a simple and inexpensive technique which can be used for both analytical and preparative procedures for biological material such as CSF, serum and extractions from nervous tissues.

Cerebrospinal Fluid Proteins↗

Simultaneous determination of coumarin, 7-hydroxycoumarin and 7-hydroxycoumarin glucuronide in human serum and plasma by high-performance liquid chromatography.

A HPLC method was developed for the determination of the metabolites of coumarin and 7-hydroxycoumarin in plasma and serum. Separation was based on gradient elution of 7-hydroxycoumarin glucuronide, 7-hydroxycoumarin, coumarin and finally 4-hydroxycoumarin (which is used as an internal standard). Standards, prepared in plasma or serum, and samples were treated with trichloroacetic acid, mixed and centrifuged. The supernatant was removed and analyzed by reversed-phase high-performance liquid chromatography on a C18 column. The limit of detection was 50 ng/ml for 7-hydroxycoumarin and 200 ng/ml for coumarin and 7-hydroxycoumarin glucuronide. The linear range was 0.5-100 micrograms/ml for each of the analytes. The percentage relative standard deviation about the mean measured concentrations were all below 10%. There was no statistical difference between the standard curves prepared in plasma or serum. The method developed was applied to the determination of each of the three compounds in serum, after the administration of 7-hydroxycoumarin, and in plasma after the administration of coumarin. The concentrations of total 7-hydroxycoumarin in the serum samples were also determined by another HPLC method and the results were compared. There was no statistical difference between the results determined.

Chromatography, High Pressure Liquid↗

An isotope-dilution gas chromatography-mass spectrometry method for trace analysis of xylene metabolites in tissues.

A gas chromatography-mass spectrometry (GC-MS) method using isotope dilution was developed to measure trace levels of xylene metabolites in brain tissues. The primary metabolites of xylene are dimethylphenol (DMP), methylbenzyl alcohol (MBA), toluic acid (TA), and methylhippuric acid (MHA). The internal standard was a mixture of deuterated DMP-d3, TA-d7, and MHA-d7. DMP-d3 was commercially available and was used as the internal standard for both DMP and MBA. TA-d7 and MHA-d7 were biosynthesized by administering xylene-d10 to rats and collecting their urine. Based on the noise peaks in 10 blank samples, the on-column limits of quantitation (mean +10 SD of noise peaks) were approximately 305, 1220, 545, and 386 pg for DMP, MBA, TA, and MHA, respectively. Analyte detection and recovery tests from brain tissues of control rats were conducted by spiking the tissues with 32 nmol/g of each analyte, together with the deuterated metabolites. The tissues were homogenized, extracted with ethyl acetate, and derivatized by trimethylsilylation. One microliter of the sample was injected into the GC-MS. The recoveries of the analytes were 104 +/- 8%, 80 +/- 9%, 93 +/- 10%, and 92 +/- 11% (mean +/- SD, n = 7) for DMP, MBA, TA, and MHA, respectively. The tissue preparation efficiency, which was indicated by absolute recoveries of internal standards, was approximately 33% for DMP, MBA, and TA and approximately 80% for MHA. No metabolites were detected in untreated control tissues. This simple and sensitive method to simultaneously detect major xylene metabolites in brain tissues could also be used for the analysis of blood and urine samples from workers to monitor p-xylene exposure.

Animals↗