Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamic range”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Minimum spectral contrast needed for vowel identification by normal hearing and cochlear implant listeners.

The minimum spectral contrast needed for vowel identification by normal-hearing and cochlear implant listeners was determined in this study. In experiment 1, a spectral modification algorithm was used that manipulated the channel amplitudes extracted from a 6-channel continuous interleaved sampling (CIS) processor to have a 1-10 dB spectral contrast. The spectrally modified amplitudes of eight natural vowels were presented to six Med-EI/CIS-link users for identification. Results showed that subjects required a 4-6 dB contrast to identify vowels with relatively high accuracy. A 4-6 dB contrast was needed independent of the individual subject's dynamic range (range 9-28 dB). Some cochlear implant (CI) users obtained significantly higher scores with vowels enhanced to 6 dB contrast compared to the original, unenhanced vowels, suggesting that spectral contrast enhancement can improve the vowel identification scores for some CI users. To determine whether the minimum spectral contrast needed for vowel identification was dependent on spectral resolution (number of channels available), vowels were processed in experiment 2 through n (n =4, 6, 8, 12) channels, and synthesized as a linear combination of n sine waves with amplitudes manipulated to have a 1-20 dB spectral contrast. For vowels processed through 4 channels, normal-hearing listeners needed a 6 dB contrast, for 6 and 8 channels a 4 dB contrast was needed, consistent with our findings with CI listeners, and for 12 channels a 1 dB contrast was sufficient to achieve high accuracy (>80%). The above-mentioned findings with normal-hearing listeners suggest that when the spectral resolution is poor, a larger spectral contrast is needed for vowel identification. Conversely, when the spectral resolution is fine, a small spectral contrast (1 dB) is sufficient. The high identification score (82%) achieved with 1 dB contrast was significantly higher than any of the scores reported in the literature using synthetic vowels, and this can be attributed to the fact that we used natural vowels which contained duration and spectral cues (e.g., formant movements) present in fluent speech. The outcomes of experiments 1 and 2, taken together, suggest that CI listeners need a larger spectral contrast (4-6 dB) than normal-hearing listeners to achieve high recognition accuracy, not because of the limited dynamic range, but because of the limited spectral resolution.

Adult↗

Nociceptive response to innocuous mechanical stimulation is mediated via myelinated afferents and NK-1 receptor activation in a rat model of neuropathic pain.

Peripheral nerve injury in humans can produce a persistent pain state characterized by spontaneous pain and painful responses to normally innocuous stimuli (allodynia). Here we attempt to identify some of the neurophysiological and neurochemical mechanisms underlying neuropathic pain using an animal model of peripheral neuropathy induced in male Sprague-Dawley rats by placing a 2-mm polyethylene cuff around the left sciatic nerve according to the method of Mosconi and Kruger. von Frey hair testing confirmed tactile allodynia in all cuff-implanted rats before electrophysiological testing. Rats were anesthetized and spinalized for extracellular recording from single spinal wide dynamic range neurons (L(3-4)). In neuropathic rats (days 11-14 and 42-52 after cuff implantation), ongoing discharge was greater and hind paw receptive field size was expanded compared to control rats. Activation of low-threshold sensory afferents by innocuous mechanical stimulation (0.2 N for 3 s) in the hind paw receptive field evoked the typical brief excitation in control rats. However, in neuropathic rats, innocuous stimulation also induced a nociceptive-like afterdischarge that persisted 2-3 min. This afterdischarge was never observed in control rats, and, in this model, is the distinguishing feature of the spinal neural correlate of tactile allodynia. Electrical stimulation of the sciatic nerve at 4 and at 20 Hz each produced an initial discharge that was identical in control and in neuropathic rats. This stimulation also produced an afterdischarge that was similar at the two frequencies in control rats. However, in neuropathic rats, the afterdischarge produced by 20-Hz stimulation was greater than that produced by 4-Hz stimulation. Given that acutely spinalized rats were studied, only peripheral and/or spinal mechanisms can account for the data obtained; as synaptic responses from C fibers begin to fail above approximately 5-Hz stimulation [Pain 46 (1991) 327], the afterdischarge in response to 20-Hz stimulation suggests a change mainly in myelinated afferents and a predominant role of these fibers in eliciting this afterdischarge. These data are consistent with the suggestion that peripheral neuropathy induces phenotypic changes predominantly in myelinated afferents, the sensory neurons that normally respond to mechanical stimulation. The NK-1 receptor antagonist, CP-99,994 (0.5 mg/kg, i.v.), depressed the innocuous pressure-evoked afterdischarge but not the brief initial discharge of wide dynamic range neurons, and decreased the elevated ongoing rate of discharge in neuropathic rats. These results support the concept that following peripheral neuropathy, myelinated afferents may now synthesize and release substance P. A result of this is that tonic release of substance P from the central terminals of these phenotypically altered neurons would lead to ongoing excitation of NK-1-expressing nociceptive spinal neurons. In addition, these spinal neurons would also exhibit exaggerated responses to innocuous pressure stimulation. The data in this study put forth a possible neurophysiological and neurochemical basis of neuropathic pain and identify substance P and the NK-1 receptor as potential neurochemical targets for its management.

Afferent Pathways↗

A dual effect of 5-HT1B receptor stimulation on nociceptive dorsal horn neurones in rats.

In this study the modulatory effects of 5-HT1B receptor activation on wide dynamic range neurones in the spinal cord were studied. Extracellular single unit recordings of dorsal horn neurones were performed in intact urethane-anaesthetized female Sprague-Dawley rats, and the receptive field distally on one hind paw was electrically stimulated with needle electrodes applied to the skin. The 5-HT1B receptor agonist, CP-93,129 (3-(1,2,5,6-tetrahydropyrid-4-yl)pyrrolo[3,2-b]pyrid-5-one), the 5-HT1A/B receptor antagonist cyanopindolol, and the 5-HT1A receptor antagonist WAY100635 (N-[2-[4-(2-methoxypheny])-1-piperazinyl]ethyl]-N-(2-pyridinyl) cyclohexanecarboxamide trihydrochloride), were applied directly onto the spinal cord, and single unit responses were counted separately for A beta-, A delta-, C-fibre responses and post-discharge according to the latencies. A dual effect of CP-93,129 was observed: 50 nmol CP-93,129 caused a clear inhibition of the A delta-fibre responses, whereas 50 and 150 nmol CP-93,129 produced a dose-dependent increase in post-discharge without affecting A beta- and C-fibre responses. Application of 50 nmol cyanopindolol or 50 nmol WAY 100635 alone did not affect neither the neuronal A-fibre nor the C-fibre responses, but when 50 nmol cyanopindolol was coadministered with 50 nmol CP-93,129 the effect of CP-93,129 alone was blocked: the A delta-fibre response was not inhibited and the post-discharge was not increased. In contrast, 50 nmol WAY100635 did not block the effect of 50 nmol CP-93,129 when the two drugs were coadministered. These results suggest that stimulation of the 5-HT1B receptors may have both pro- and antinociceptive effects on wide dynamic range neurones in the dorsal horn after repeated electrical stimulation.

Action Potentials↗

Targeted proteomics of low-level proteins in human plasma by LC/MSn: using human growth hormone as a model system.

This paper describes the profiling of human growth hormone (hGH) in human plasma in order to assess the dynamic range of the ion-trap mass spectrometer for proteomic studies of complex biological samples. Human growth hormone is an example of a low-level plasma protein in vivo, present at subfemtomole levels. This study was performed on a plasma sample in which hGH has been spiked at 10-fold above the natural level, that is approximately 16 pg/microL of plasma. Initially, the measurement was carried out without any sample enrichment and consisted of the following steps: the full set of plasma proteins were reduced, alkylated, and digested with trypsin, and the resulting peptides were separated on a capillary C-18 column and then detected by ion-trap mass spectrometry (1D LC/MS). In addition, this study provided a global view of the serum proteome with over 200 plasma proteins being preliminarily identified. In the MS/MS analysis, hGH was detected by characterization of the first tryptic peptide (T1). The initial identification was confirmed by alternative approaches, which also allowed the evaluation of different sample purification protocols. First, the plasma sample containing hGH was fractionated on a reversed-phase HPLC column and digested, and hGH could now be identified by MS/MS measurements of two tryptic peptides (T1 and T4) by the same 1D LC/MS protocol. In addition, the assignment of peptide identity was made with higher certainty (as measured by an algorithm score). The plasma sample was also fractionated by 1D and 2D gel electrophoresis, the selected bands were digested and analyzed again by the 1D LC/MS protocol. In both cases using the gel prepurifications, hGH was identified with additional peptides. Finally, the plasma sample was analyzed by 2D chromatography (ion exchange and reversed phase) on a new instrumental platform (ProteomeX), and hGH was identified by the observation of five tryptic peptides. In conclusion, these experiments were able to detect growth hormone in the low femtomole level with a dynamic range of 1 in 40 000 by several independent approaches. The amount of growth hormone, while 10-fold above normal in vivo levels, represents concentrations that may be present in disease states (such as acromegaly) and also in doping control measurements. These studies have demonstrated that shotgun sequencing approaches (LC/MS/MS) not only can profile high-abundance proteins in complex biological fluids but also have the potential to identify and quantitate low-level proteins present in such complex mixtures without extensive prepurification protocols. A key to such studies, however, is to use targeted approaches that reduce the complexity of the solute mixture that is presented to the mass spectrometer at a given time point. The various sample preparation protocols described here all improved the quality of the hGH measurement, although in this study the 2D chromatographic approach gave the greatest sequence coverage.

Calibration↗

Visualization of conserved structures by fusing highly variable datasets.

INTRODUCTION: Skill, effort, and time are required to identify and visualize anatomic structures in three-dimensions from radiological data. Fundamentally, automating these processes requires a technique that uses symbolic information not in the dynamic range of the voxel data. We were developing such a technique based on mutual information for automatic multi-modality image fusion (MIAMI Fuse, University of Michigan). This system previously demonstrated facility at fusing one voxel dataset with integrated symbolic structure information to a CT dataset (different scale and resolution) from the same person. The next step of development of our technique was aimed at accommodating the variability of anatomy from patient to patient by using warping to fuse our standard dataset to arbitrary patient CT datasets. METHODS: A standard symbolic information dataset was created from the full color Visible Human Female by segmenting the liver parenchyma, portal veins, and hepatic veins and overwriting each set of voxels with a fixed color. Two arbitrarily selected patient CT scans of the abdomen were used for reference datasets. We used the warping functions in MIAMI Fuse to align the standard structure data to each patient scan. The key to successful fusion was the focused use of multiple warping control points that place themselves around the structure of interest automatically. The user assigns only a few initial control points to align the scans. Fusion 1 and 2 transformed the atlas with 27 points around the liver to CT1 and CT2 respectively. Fusion 3 transformed the atlas with 45 control points around the liver to CT1 and Fusion 4 transformed the atlas with 5 control points around the portal vein. The CT dataset is augmented with the transformed standard structure dataset, such that the warped structure masks are visualized in combination with the original patient dataset. This combined volume visualization is then rendered interactively in stereo on the ImmersaDesk in an immersive Virtual Reality (VR) environment. RESULTS: The accuracy of the fusions was determined qualitatively by comparing the transformed atlas overlaid on the appropriate CT. It was examined for where the transformed structure atlas was incorrectly overlaid (false positive) and where it was incorrectly not overlaid (false negative). According to this method, fusions 1 and 2 were correct roughly 50-75% of the time, while fusions 3 and 4 were correct roughly 75-100%. The CT dataset augmented with transformed dataset was viewed arbitrarily in user-centered perspective stereo taking advantage of features such as scaling, windowing and volumetric region of interest selection. CONCLUSIONS: This process of auto-coloring conserved structures in variable datasets is a step toward the goal of a broader, standardized automatic structure visualization method for radiological data. If successful it would permit identification, visualization or deletion of structures in radiological data by semi-automatically applying canonical structure information to the radiological data (not just processing and visualization of the data's intrinsic dynamic range). More sophisticated selection of control points and patterns of warping may allow for more accurate transforms, and thus advances in visualization, simulation, education, diagnostics, and treatment planning.

Algorithms↗

Tuning FlaSh: redesign of the dynamics, voltage range, and color of the genetically encoded optical sensor of membrane potential.

The optical voltage sensor FlaSh, made from a fusion of a GFP "reporter domain" and a voltage-gated Shaker K(+) channel "detector domain," has been mutagenically tuned in both the GFP reporter and channel detector domains. This has produced sensors with improved folding at 37 degrees C, enabling use in mammalian preparations, and yielded variants with distinct spectra, kinetics, and voltage dependence, thus expanding the types of electrical signals that can be detected. The optical readout of FlaSh has also been expanded from single wavelength fluorescence intensity changes to dual wavelength measurements based on both voltage-dependent spectral shifts and changes in FRET. Different versions of FlaSh can now be chosen to optimize the detection of either action potentials or synaptic potentials, to follow high versus low rates of activity, and to best reflect electrical activity in cell types with distinct voltages of operation.

Biosensing Techniques↗

Petroleomics: the next grand challenge for chemical analysis.

Ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry has recently revealed that petroleum crude oil contains heteroatom-containing (N,O,S) organic components having more than 20,000 distinct elemental compositions (C(c)H(h)N(n)O(o)S(s)). It is therefore now possible to contemplate the ultimate characterization of all of the chemical constituents of petroleum, along with their interactions and reactivity, a concept we denote as "petroleomics". Such knowledge has already proved capable of distinguishing petroleum and its distillates according to their geochemical origin and maturity, distillation cut, extraction method, catalytic processing, etc. The key features that have opened up this new field have been (a) ultrahigh-resolution FT-ICR mass analysis, specifically, the capability to resolve species differing in elemental composition by C(3) vs SH(4) (i.e., 0.0034 Da); (b) higher magnetic field to cover the whole mass range at once; (c) dynamic range extension by external mass filtering; and (d) plots of Kendrick mass defect vs nominal Kendrick mass as a means for sorting different compound "classes" (i.e., numbers of N, O, and S atoms), "types" (rings plus double bonds), and alkylation ((-CH(2))(n)) distributions, thereby extending to >900 Da the upper limit for unique assignment of elemental composition based on accurate mass measurement. The same methods are also being applied successfully to analysis of humic and fulvic acids, coals, and other complex natural mixtures, often without prior or on-line chromatographic separation.

Chemistry Techniques, Analytical↗

Comprehensive analysis of complex proteomes using microscale solution isoelectrofocusing prior to narrow pH range two-dimensional electrophoresis.

Comprehensive analysis of complex proteomes requires prefractionation of samples prior to two-dimensional gel electrophoresis (2-DE). This study demonstrates the utility of using a high resolution sample prefractionation method and slightly overlapping narrow pH range two-dimensional gel electrophoresis to enhance quantitative comparisons of complex proteomes. A key feature of this strategy is to prefractionate samples into a few well-defined pools using microscale solution isoelectric focusing (nusol-IEF) prior to 2-DE protein analysis. Sample prefractionation is achieved using a series of tandem small volume chambers (500 nuL) separated by thin membranes containing immobilines at specific pH's. The resulting well-resolved fractionated samples are optimally separated on a series of slightly overlapping narrow pH range immobilized pH gradient (IPG) gels, which are approximately 0.1 pH units wider than the nusol-IEF fractionated pools. When nusol-IEF prefractionation was applied to proteome analyses of mouse serum, it resulted in the capacity to separate much higher protein loads on narrow pH range IPG gels while retaining good resolution and spot recovery. More importantly, the prefractionation of serum greatly enhanced the ability to detect low abundance proteins, because major interfering proteins were removed from most fractions. At least 6- to 30-fold higher protein loads were possible for nonalbumin fractions on narrow pH range IPG gels. The dynamic range of protein detection is substantially increased since higher protein loads can be applied to narrow pH range 2-DE gels, and duplicate gels can be stained with colloidal Coomassie and silver stains for quantitation of abundant and minor proteins, respectively. Finally, the ability to effectively fractionate complex proteomes into very narrow ranges (< 0.5 pH units) strongly suggests that nusol-IEF could be used to prefractionate complex samples for subsequent direct analysis by liquid chromatography-tandem mass spectrometry methods as an alternative to using overlapping narrow pH range 2-DE gels.

Animals↗

Transcranial Doppler for monitoring the cerebral blood flow dynamics: normal ranges in the Italian female population.

AIM: This study was aimed at recording, by means of a transcranial Doppler (TCD) device, the values of blood flow velocities (BFV) in the middle cerebral artery (MCA) in physiological conditions, in a population of healthy women in various ages of their life, in order to establish normative data in an Italian female population. METHODS: Our sample consisted of 100 healthy women (mean age 38 +/-15.14 years, range 12-78) that underwent an investigation of the intracranial circulation by means of TCD. Patients were subdivided into 4 age groups: less than 20 years; 20-34 years; 35-50 years; more than 50 years. RESULTS: No statistically significant differences were present between the mean BFV in the left and right MCAs of the subjects considered as a unique population (left MCA 68.06+/-9.22 cm/s; right MCA 66.71+/-8.79 cm/s). The BFVs tended to significantly decrease with the increasing of age. In fact, they were so distributed: left MCA 82.55+/-6.85 cm/s and right MCA 80.27+/-4.13 cm/s in the younger group; left MCA 72.15+/-6.37 cm/s and right MCA 70.68+/-6.79 cm/s in women aged 20-34; left MCA 63.85+/-7.08 cm/s and right MCA 63.06+/-7.29 cm/s in women aged 35-50; left MCA 60.67+/-6.85 cm/s and right MCA 59.10+/-5.36 cm/s in the last group. CONCLUSIONS: The present study defined a normal age-related range of variations in MCA BFVs, useful for future comparisons in studies involving pathological female subjects.

Adolescent↗

Development and review of radioimmunoassay of 12-S-hydroxyheptadecatrienoic acid.

For more than 25 years 12-S-hydroxyheptadecatrienoic acid (HHT) has been known to be a product of thromboxanesynthase (TX-Syn) when synthesized with thromboxane A2 (TXA2). Although there are some hints that HHT has anti-aggregatory effects, to date, it has neither been shown to have any specific pathological relevance nor is there much information about its physiological role. This review presents a summary of the physicochemical properties of HHT, its chemical synthesis, the impact of various biological systems on its enzymatic and non-enzymatic production and its physiological function and metabolization, as well as a survey of the most important methods for analyzing this unsaturated hydroxy-fatty acid. Due to the low antibody-raising potency expected in HHT, no immunological system for HHT quantification has been developed so far. In our report we present the development and validation of a sensitive and reliable, competitive radioimmunoassay (RIA) suitable for the quantitative determination of HHT. HHT was produced by an enhanced enzymatic method using platelet-rich plasma (PRP). With an effective and modified liquid-liquid and solid-phase extraction method we were able to produce highly purified HHT (97% purity by GC/MS) in sub-milligram ranges. These fractions were used for the synthesis of BSA-antigen-conjugates and for immunization of rabbits. The tritiated tracer was synthesized using prostaglandin H synthase for the production of prostaglandin H2 (PGH2) followed by an aqueous reaction with Fe(2+)-solution to rear-range PGH2 to HHT. The dynamic range of the assay was from 30-400 pg/tube, with a sensitivity of approximately 40 pg/tube. The evaluation of the assay was performed by a HPLC-RIA method as well as by correlation with a quantitative HPLC method and correlation with TXB2 concentrations in a blood coagulation study. The assay may be useful for the quantification of HHT in several tissues and body fluids under various physiological conditions and may also help to understand the possible physiological role of HHT in biological processes.

Animals↗

Distinct short-term plasticity at two excitatory synapses in the hippocampus.

A single mossy fiber input contains several release sites and is located on the proximal portion of the apical dendrite of CA3 neurons. It is, therefore, well suited to exert a strong influence on pyramidal cell excitability. Accordingly, the mossy fiber synapse has been referred to as a detonator or teacher synapse in autoassociative network models of the hippocampus. The very low firing rates of granule cells [Jung, M. W. & McNaughton, B. L. (1993) Hippocampus 3, 165-182], which give rise to the mossy fibers, raise the question of how the mossy fiber synapse temporally integrates synaptic activity. We have therefore addressed the frequency dependence of mossy fiber transmission and compared it to associational/commissural synapses in the CA3 region of the hippocampus. Paired pulse facilitation had a similar time course, but was 2-fold greater for mossy fiber synapses. Frequency facilitation, during which repetitive stimulation causes a reversible growth in synaptic transmission, was markedly different at the two synapses. At associational/ commissural synapses facilitation occurred only at frequencies greater than once every 10 s and reached a magnitude of about 125% of control. At mossy fiber synapses, facilitation occurred at frequencies as low as once every 40 s and reached a magnitude of 6-fold. Frequency facilitation was dependent on a rise in intraterminal Ca2+ and activation of Ca2+/calmodulin-dependent kinase II, and was greatly reduced at synapses expressing mossy fiber long-term potentiation. These results indicate that the mossy fiber synapse is able to integrate granule cell spiking activity over a broad range of frequencies, and this dynamic range is substantially reduced by long-term potentiation.

4-Aminopyridine↗

Phase-coupled two-dimensional speckle tracking algorithm.

A new two-dimensional (2-D) speckle tracking method for displacement estimation based on the gradients of the magnitude and phase of 2-D complex correlation in a search region is presented. The novelty of this approach is that it couples the phase and magnitude gradients near the correlation peak to determine its coordinates with sub-sample accuracy in both axial and lateral directions. This is achieved with a minimum level of lateral interpolation determined from the angles between the magnitude and phase gradient vectors on the sampled (laterally interpolated) 2-D cross-correlation grid. The key result behind this algorithm is that the magnitude gradient vectors' final approach to the true peak is orthogonal to the zero-phase contour. This leads to a 2-D robust projection on the zero-phase contour that results in subsample accuracy at interpolation levels well below those needed using previously proposed methods. A full description of the 2-D, phase-coupled approach is given, including two implementations based on a geometric projection and constrained optimization. In addition, a robust fast search algorithm that allows the localization of the true peak without the need for exhaustive search is given. Experimental validation on three data sets from speckle-generating phantoms undergoing uniform diagonal motion, uniform axial deformation, and nonuniform lateral flow is given. It is shown that estimated 2-D displacement fields obtained using the phase-coupled technique display a full range of values covering the dynamic range without evidence of quantization. In comparison, a previously published method using 1-D phase-projection after lateral interpolation produces severely quantized lateral displacement fields (at the same levels of interpolation as the 2-D, phase-coupled method).

Algorithms↗

Optical frequency-domain reflectometry with a rapid wavelength-scanning superstructure-grating distributed Bragg reflector laser.

Superstructure-grating distributed Bragg reflector lasers are particularly suited for optical frequency-domain reflectometry optical-coherence tomography with wide wavelength tunability and frequency agility. We report theoretical estimates of and experimental results for the data acquisition speed, the observable depth range, the resolution, and the dynamic range of an optical frequency-domain reflectometry system that uses a superstructure-grating distributed Bragg reflector laser whose wavelength can be tuned from 1533 to 1574 nm with a tuning speed of 10 micros/0.1-nm step.

Equipment Design↗

Clinical evaluation of amperometric enzyme electrodes in continuous-flow analysis for glucose in undiluted whole blood.

We have evaluated the carbon-paste enzyme/wall-jet electrode in continuous-flow analysis for glucose in undiluted whole blood. Responses of the electrode to protein-based and aqueous samples under wall-jet configuration are described. Imprecision in the flow-injection mode was less than 2% for glucose values in the usual analytical range (1-25 mmol/L). The dynamic range for glucose was from 0.03 to 45 mmol/L, with about 100% recovery of added substrate. The performance of the electrode (y) in flow-injection and steady-state modes was compared with a colorimetric method (x; Kodak Ektachem XR700), yielding linear-regression equations of y = 1.152x + 0.295 and y = 0.979x + 0.500, respectively. Among the anticoagulants, blood preservatives, and interfering substances investigated, only ascorbic acid gave a significant positive bias. The electrode exhibited good stability for analyses of undiluted whole-blood samples.

Autoanalysis↗

[Improvement of grating spectrograph and its application to frequency-doubling in PPLN].

Charge-coupled device (CCD) has been widely used in spectral detection and spectral imaging fields, which has a number of benefits: broad spectral range response, low detection limit, wide dynamic range, minimal dark current and readout noise as well as the abilities of signal integration, simultaneous multichannel detection, and real-time detection. The combination of a traditional one meter grating spectrograph and a science charge-coupled device (CCD) led to a real-time grating spectrograph for laser spectrum detection developed in this paper. Based on the new grating spectrograph, the spectral characteristic of frequency-doubling of a broad band double-cladding fiber laser in polarized lithium niobate (PPLN) has been investigated. Dynamic spectrum of the second harmonic with varying temperature of PPLN has been observed and analyzed in detail.

English Abstract↗

The Orbitrap: a new mass spectrometer.

Research areas such as proteomics and metabolomics are driving the demand for mass spectrometers that have high performance but modest power requirements, size, and cost. This paper describes such an instrument, the Orbitrap, based on a new type of mass analyzer invented by Makarov. The Orbitrap operates by radially trapping ions about a central spindle electrode. An outer barrel-like electrode is coaxial with the inner spindlelike electrode and mass/charge values are measured from the frequency of harmonic ion oscillations, along the axis of the electric field, undergone by the orbitally trapped ions. This axial frequency is independent of the energy and spatial spread of the ions. Ion frequencies are measured non-destructively by acquisition of time-domain image current transients, with subsequent fast Fourier transforms (FFTs) being used to obtain the mass spectra. In addition to describing the Orbitrap mass analyzer, this paper also describes a complete Orbitrap-based mass spectrometer, equipped with an electrospray ionization source (ESI). Ions are transferred from the ESI source through three stages of differential pumping using RF guide quadrupoles. The third quadrupole, pressurized to less than 10(-3) Torr with collision gas, acts as an ion accumulator; ion/neutral collisions slow the ions and cause them to pool in an axial potential well at the end of the quadrupole. Ion bunches are injected from this pool into the Orbitrap analyzer for mass analysis. The ion injection process is described in a simplified way, including a description of electrodynamic squeezing, field compensation for the effects of the ion injection slit, and criteria for orbital stability. Features of the Orbitrap at its present stage of development include high mass resolution (up to 150,000), large space charge capacity, high mass accuracy (2-5 ppm), a mass/charge range of at least 6000, and dynamic range greater than 10(3). Applications based on electrospray ionization are described, including characterization of transition-metal complexes, oligosaccharides, peptides, and proteins. Use is also made of the high-resolution capabilities of the Orbitrap to confirm the presence of metaclusters of serine octamers in ESI mass spectra and to perform H/D exchange experiments on these ions in the storage quadrupole.

Alcohol Dehydrogenase↗

The analysis of conductive solid samples by r.f. capacitively coupled plasma at atmospheric pressure.

A radiofrequency capacitively coupled plasma (rf CCP) with tip-ring electrode geometry has been used for the analysis of Al, Co, Cr, Cu, Mn, Mo, Ni, and V in low and medium alloyed steel. The sample is used as one of the electrodes of the plasma torch. The influence of plasma power, argon flow rate and distance between the electrodes on the analytical signals has been studied. The limits of detection are in the range of 0.001 to 0.048%. The dynamic range is three orders of magnitude.

Journal Article↗