Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Trephining”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Modified automated lamellar therapeutic keratoplasty for keratoconus: a new technique.

PURPOSE: To describe a modified automated lamellar therapeutic keratoplasty (ALTK) technique for the treatment of keratoconus. METHODS: The ALTK procedure was modified to include the use of a Hanna trephine system to control donor and recipient diameters and was performed in 2 stages. The recipient corneal lamellar bed was first prepared by creating a laser in situ keratomileusis (LASIK) flap at a preset depth that was left to heal over. The second stage involved the use of a Hanna trephination system to perform central trephination within the lamellar flap and transplantation of a donor lamellar graft that was fashioned to precisely match the recipient corneal bed, again using the Hanna donor punch to create a central trephination within the lamellar button obtained with the ALTK unit. RESULTS: The modified ALTK procedure effectively treated a patient with moderate keratoconus with a best-corrected visual acuity of 20/80, despite rigid gas-permeable contact lenses. Postoperatively, there was a significant reduction in the irregular astigmatism, and visual acuity improved to 20/25. There were no complications, and the ALTK interface remained clear throughout the 20-month follow-up period. CONCLUSIONS: ALTK combined with Hanna trephination enables precise control of both depth and diameter of lamellar dissection during surgery, removes the need for any form of manual dissection, and may therefore improve optical and visual outcomes in lamellar keratoplasty.

Adult↗

Laboratory analysis of the Lieberman Corneal Punch.

The Lieberman Corneal Punch, an instrument for the trephination of corneal donor tissue, was tested in the laboratory on human corneas preserved in McCarey-Kaufman (M-K) medium. Excellent corneal buttons were produced using 7.5-and 8.0-mm trephine blades, but trephination quality was variable using 8.5 and 9.0 mm blades. Modification of the curvature of the punching well may improve the trephination quality with the larger trephine blades.

Corneal Transplantation↗

[Value of a new apparatus for percutaneous vertebral bone biopsy].

Percutaneous vertebral trephine biopsy is a valuable investigation. A new type of trephine needle for vertebral biopsy is described in this paper. This trephine needle is introduced on the thin needle used for local anesthesia, following a procedure similar to vascular catheterism. Thus, the same puncture is used for local anesthesia and bone biopsy. Therefore, local anesthesia is more effective and the biopsy procedure is much safer, particularly at the thoracic level where vital organs are very close to the spine. A very practical handle design for advancing the trephine needle on the guide wire makes the biopsy procedure easy and precise. This trephine needle enhance indications of this potentially valuable procedure.

Biopsy, Needle↗

[The penetrating keratoplasty. A 100-year success story].

Ten precautions for prophylaxis of astigmatism in penetrating keratoplasty are recommended:1. The attempt should be made to determine donor topography for exclusion of previous refractive surgery, keratoconus/high astigmatism, and to allow for "harmonization" of donor and recipient topography.2. Donor and recipient trephination should be performed from the epithelial side with the same system, which is the prerequisite for congruent cut surfaces and angles in donor and recipient. For this purpose an artificial anterior chamber is used for donor trephination.3. Orientation structures in donor and host facilitate the correct placement of the first four or eight cardinal sutures to avoid horizontal torsion.4.A measurable improvement seems to be possible, using the Krumeich guided trephine system (GTS), the second generation Hanna trephine, and the Erlangen technique of nonmechanical trephination with the excimer laser.5. Horizontal positioning of the head and limbal plane are indispensable for state-of-the-art PKP surgery in order to avoid decentration, vertical tilt, and horizontal torsion.6. Graft size should be adjusted individually ("as large as possible, as small as necessary").7. Limbal centration should be preferred over pupil centration (especially in keratoconus).8. Excessive graft over- or undersize should be avoided to prevent stretching or compression of peripheral donor tissue.9. As long as Bowman's layer is intact a double running cross-stitch suture (according to Hoffmann) is preferred since it results in higher topographic regularity, earlier visual rehabilitation, and less suture loosening requiring only rarely suture replacement.10.Intraoperative keratoscopy should be applied after removal of lid specula and fixation sutures.

Astigmatism↗

[Penetrating re-keratoplasty a chaud using healon 5 for stabilizing the anterior chamber].

BACKGROUND: Penetrating keratoplasty in cases of perforated corneal ulcers is a technical challenge. The loss of anterior chamber volume during trephination causes irregularities of surgical margins and carries the risk of trauma to iris and crystalline lens. The highly viscous substance Healon 5 allows a deep anterior chamber to be maintained even in cases of rather large perforations. CASE REPORT: A 34-year-old man presented with acutely perforated ulcer on the transplant-host interface. Perforating minikeratoplasty (diameter 4.5 mm) including the corneal limbus had been performed 3 years previously because of a perforated ulcer after pterygium surgery. Corneal melting extending to the visual axis required a large-diameter transplant (8.0 mm), partially including the former transplant. Before trephination the anterior chamber was restored with Healon 5. Despite the fairly large perforation site we did not note any anterior chamber shallowing during trephination. Hardly any bleeding occurred perioperatively, although deep and superficial neovascularizations in the former transplant were cut. The postoperative course was uneventful with no rise in intraocular pressure. After 4 weeks, postoperative pinhole visual acuity with the preoperative correction (1.5 dpt. cyl.) was 0.7, with a topographic astigmatism of 6.5 dpt. CONCLUSION: In the case presented here, a regular recipient wound bed as a prerequisite for a relatively low postoperative astigmatism was created by the use of Healon 5 for anterior chamber stabilization during trephination.

Adult↗

Inverse mushroom-shaped nonmechanical penetrating keratoplasty using a femtosecond laser.

PURPOSE: To demonstrate the feasibility of an inverse mushroom-shaped nonmechanical corneal trephination using a femtosecond laser in a noncontact manner. DESIGN: Experimental study. METHODS: In this laboratory study, 10 polymethylmethacrylate (PMMA) blocks and 20 porcine corneas were treated with an industrial femtosecond laser source. The trephination profile consisted of (1) a 7- or 6-mm diameter cylinder from the anterior chamber, (2) an intermediate horizontal connecting plane, and (3) a concentric 5- or 4-mm diameter cylinder upwards. RESULTS: Applying appropriate combinations of pulse energy and spacing, trephination took less than 60 seconds. In porcine eyes, light microscopy displayed trephination edges delineated by partly confluent gas bubbles (10-40 mum) with tissue bridges in between. By TEM, the cut edges were lined by a delicate, electron-dense layer (5-40 nm). CONCLUSIONS: Femtosecond laser technology seems to offer a promising approach towards minimally invasive self-sealing "no-stitch keratoplasty."

Agaricales↗

Femtosecond laser-assisted posterior lamellar keratoplasty: initial studies of surgical technique in eye bank eyes.

OBJECTIVE: To perfect the technique of femtosecond laser-assisted cutting of the lamellar corneal disc in posterior lamellar keratoplasty. DESIGN: Experimental study. METHODS: The femtosecond laser was used to make the posterior corneal lamellar interface and trephine (side) cut in 20 eye bank globes and 9 eye bank corneoscleral buttons. Laser parameters were energy 7.4+/-0.1 microJ (lamellar cut) and 8.7+/-0.1 microJ (trephination cut), spot size 2.4 microm, firing rate 15 kHz, and trephination diameter 6.0 to 8.0 mm. The thicknesses of the excised corneal discs were measured with a digital micrometer and compared with values calculated from the laser treatment parameters and the preoperative ultrasound pachymetric readings. The cut surfaces were examined by light microscopy and scanning electron microscopy. In globes, the corneal disc was removed from the eye after laser treatment through a blade incision in the peripheral cornea. In corneoscleral buttons, the posterior disc was peeled off the cornea with forceps after laser treatment on an artificial anterior chamber device. In simulated transplantation, the excised corneal disc was placed into the posterior stromal bed in 7 globes. RESULTS: The femtosecond laser was successful in making posterior lamellar and trephination cuts in cornea. The cut surfaces were of very good quality with straight, orthogonal edges, albeit with a mild stucco texture of the lamellar stromal surfaces. In 3 globes, the lamellar surface showed shallow concentric ridges. The measured thickness of the excised discs was 55+/-61 microm thicker than the preoperatively predicted values. CONCLUSIONS: These preliminary studies show that the femtosecond laser can make nonmechanical cuts for posterior lamellar keratoplasty with relative ease and reliability, thus facilitating the most technically difficult step in this surgery.

Cornea↗

Histological, cytological and immunological analyses are complementary for the detection of neuroblastoma cells in bone marrow.

On 80 occasions 4 iliac biopsy trephines and 4 iliac aspirations were performed in 37 children with neuroblastoma at various stages of the disease. In 38 of these procedures, tumour cells were detected. In 24% of cases, both trephines and aspirates were positive, whereas in 63% neuroblastoma cells were detected only on the trephines and in 13% only on the aspirates. In addition, in 37% of the stagings, only one out of the 8 investigations was abnormal. Only in one of 33 pathological cases, was BM involvement diagnosed on trephine imprint. No involvement was ever observed on tibial and sternal aspirates without iliac involvement. Immunological studies with two monoclonal antibodies HSAN 1-2 and UJ13A were performed on 56 occasions. Cytohistological and immunological studies were concordant in 39. In 3 studies, the antigens recognized by the two monoclonal antibodies were not expressed by the initial tumour and in 3 additional studies immunological results were falsely negative; but in 11 cases monoclonal antibodies identified residual malignancy despite normal cytohistology. From this study, biopsies appear more helpful to detect malignant cells than aspirates. Immunological staining clearly leads to a better definition of tumour cells in aspirates.

Biopsy↗

[193 excimer laser trepanation in perforating keratoplasty. Report of 70 patients].

BACKGROUND: In penetrating keratoplasty, trephination with the 193 nm excimer laser may help avoid the differences in the deformation of the donor and recipient wound margins which occur with the conventional procedure. By varying the shape of the "open metal mask", other cut configurations can be achieved besides circular. Thus, "vertical tilt" and "horizontal torsion", both potential reasons for persistent long-term astigmatism after PK, may be minimized. Following experimental studies, the authors present the results obtained in their first 70 consecutive patients. PATIENTS AND METHODS: 38 women and 32 men were treated (mean age 60.6 years, range 17 to 89 years). Indications were corneal processes without vascularization: Fuchs' dystrophy (n = 32), other stromal dystrophies (n = 5), secondary corneal endothelial decompensation (n = 6), keratoconus (n = 15), nonvascularized corneal scars (n = 4) and miscellaneous (n = 8 ). We used elliptical metal masks with/without orientation teeth and circular masks with four and eight orientation teeth, respectively. The HeNe aiming beam was manually controlled by a micromanipulator ("joystick"). The technical data of the laser were as follows: spot mode, 1.5 x 1.5 mm; repetition rate 30/sec and 25/sec, respectively; pulse energy 15-25 mJ; mean number of pulses 6407 (recipient) and 9150 (donor). With an elliptical outline, wound closure was usually achieved with single sutures. With a circular outline with orientation teeth, wound closure was most commonly achieved with a double running suture. Patients were prospectively documented using modified Erlangen record sheets. Follow-up ranged from 3 months to 3.4 years (mean 11.4 months). RESULTS: With two exceptions, penetration of the anterior chamber with the 193 nm excimer laser was accomplished without deformation of the cut edges. The elliptical outline facilitated fitting of the graft into the recipient wound bed, and the orientation teeth made fitting even easier. Initial intraoperative complications due to excessive laser energy densities included minor thermally induced corneal alterations caused by the heat of the metal mask and in a few cases minimal iris bleeding during corneal penetration. The median duration of re-epithelialization was two days. Wound healing was without complications. In particular, no primary graft insufficiency and no unexpected effects in donor or recipient corneas, iris, lens or posterior segments were observed. Postoperative complications were one corneal ulcer caused by premature fitting of an extended-wear contact lens and two immunologic graft reactions (3%). Mean astigmatism after suture removal was 4.6 D with an elliptical outline, and 3.9 D after trephination with orientation teeth and with the sutures in situ. CONCLUSION: Non-mechanical, "non-thermal" trephination with elliptical and circular metal masks with orientation teeth represents a viable alternative to knife trephination in penetrating keratoplasty. No unexpected complications such as disturbances of wound healing were seen. Further studies are needed to determine the effect on residual long-term astigmatism after suture removal.

Adolescent↗

Hematopathology of the bone marrow in pediatric cutaneous mastocytosis. A study of 17 patients.

Sixteen bone marrow aspirates and 15 trephine core biopsies from 17 children with cutaneous mastocytosis, of which 15 exhibited urticaria pigmentosa and 2 exhibited diffuse cutaneous mastocytosis, were evaluated for the presence of bone marrow-associated pathologic conditions. Eight bone marrow aspirates from 8 children and 23 trephine core bone marrow biopsies from 16 children who had had evaluation for hematologic abnormalities not associated with cutaneous mastocytosis served as a control population. Eosinophilia was a prominent finding in bone marrows of 9 of 17 patients who had cutaneous mastocytosis. Increased mast cell numbers in bone marrow aspirates were observed in 5 children with cutaneous mastocytosis (5 of 16) and in 2 of the control children (2 of 8). Examination of the trephine core bone marrow biopsies obtained from patients with cutaneous mastocytosis demonstrated focal perivascular and paratrabecular aggregates consisting of mast cells, eosinophils, and early myeloid cells in 10 of 15 individuals. Similar lesions were observed in trephine core bone marrow biopsies of 3 of 16 control patients. The focal mast cell lesions characteristic of adult systemic mastocytosis were not observed. The authors conclude that cutaneous mastocytosis in the pediatric age group is rarely associated with definitive bone marrow findings suggestive of systemic mast cell disease and that this observation is consistent with previous reports that cutaneous mastocytosis in the majority of pediatric cases resolves by adulthood.

Bone Marrow↗

Technique to minimize asymmetric suture placement during penetrating keratoplasty.

PURPOSE: Surgeons must mark the donor and recipient tissues precisely during penetrating keratoplasty, and verify the correct position of these marks in the actual donor button and trephine sites to minimize asymmetric placement of the graft within the host wound. METHODS: A unique surgical reticule has been developed that simplifies proper marking of both the donor and recipient tissues with gentian violet. The reticule is placed within the oculars of the operating microscope. The circumference of the donor tissue and partial-thickness trephined host wound are aligned with a 5 mm inscribed circle. Eight equidistant lines, separated by 45 degrees around the circle, are used to place marks on the donor tissue and confirm the correct peripheral placement of limbal lines on the host tissue. The surgeon uses these landmarks for cardinal suture placement. RESULTS: The reticule is easy to use with any size of trephine, and does not interfere with other surgical maneuvers during surgery. CONCLUSIONS: Correct suturing of the first eight cardinal sutures can occur only if the donor button is marked after it has been prepared, and the location of the recipient marks are verified after the actual trephination impression has been made. This reticule should minimize the role of asymmetric suturing on final graft astigmatism.

Astigmatism↗

Osteonecrosis after powered core decompression.

A 44-year-old man with alcohol-related osteonecrosis of his left femoral head, Ficat Stage 2, was treated by femoral head decompression. During this procedure the (1/4)-inch trephine driven by a power reamer became lodged in the femoral head and became hot to the touch. The trephine eventually was removed with difficulty after the decompression was completed. Four and a half years later, the patient continued to have progressive pain and difficulty ambulating. A radiograph at the time revealed a wide zone of symmetric increased density about the core decompression track. A total hip arthroplasty was done, yielding the femoral head and neck for study. Histologic sections of the femoral head and neck showed that the entire length of the core decompression track in the specimen was surrounded by 2.7 cm of unrepaired necrotic bone. The evidence suggests that extensive additional necrosis was produced iatrogenically during the core decompression with the powered trephine. Necrosis secondary to either heat generation or increased pressure along the trephine track is presented as possible mechanisms for this unusual finding.

Adult↗

Initial results of anterior interbody fusion achieved with a less invasive bone harvesting technique.

STUDY DESIGN: A retrospective review. OBJECTIVE: To review the initial experience using a trephine bone harvesting system from the local lumbar spine for use in anterior interbody fusions, analyzing fusion rates and complications. SUMMARY OF BACKGROUND DATA: Historically, autogenous bone for lumbar spine fusions has been procured from the iliac crest. No data exist regarding the use of a trephine bone harvesting system for obtaining cancellous bone locally from the lumbar spine for use in anterior interbody fusions. In this technique, the donor site is replaced with a corticocancellous humeral dowel. METHODS: A total of 36 patients who underwent anterior lumbar interbody fusion were retrospectively reviewed. There were 56 interbody fusions performed using 36 trephine donor sites. Twenty individuals had the bone divided between 2 fusion levels, placed within allograft femoral rings, and 16 had the bone applied to 1 fusion level. Radiographs were analyzed for complications associated with the fibular dowel and time to interbody fusion. RESULTS: By 6 months, 35 of 36 (97%) of the corticocancellous fibular dowels had incorporated. Two dowels migrated 3 mm, each without sequelae. Of 56 of interbody spaces, 50 (89%) were fused. Two eventually fused at 9 and 11 months, and 4 (7%) failed to unite by 15 months. CONCLUSION: Harvesting cancellous autograft anteriorly from the lumbar spine using a trephine technique appears to be safe and reliable, with satisfactory fusion rates. Iliac crest graft harvesting with its attendant morbidity is avoided.

Bone Transplantation↗

In vivo femtosecond laser-assisted posterior lamellar keratoplasty in rabbits.

PURPOSE: To develop a rabbit model for femtosecond laser-assisted posterior lamellar keratoplasty. METHODS: The femtosecond laser was used to make the posterior corneal lamellar interface and trephine (side) cut in 12 eyes of 11 rabbits. Laser parameters were energy 6.0 to 8.7 (lamellar cut) and 6.0 to 8.8 microJ (trephination cut), spot size 2.4 microm, firing rate 15 kHz, and trephination diameter 6.0 to 7.0 mm. In all eyes, the posterior corneal disc was removed from the eye after laser treatment through a blade incision in the peripheral cornea. The same excised corneal disc was repositioned into the posterior stromal bed to simulate posterior lamellar transplantation. Four eyes of 3 rabbits were enucleated immediately after surgery, and 8 eyes of 8 rabbits were enucleated after a mean follow-up of 17.9 +/- 6.5 weeks. The corneal cut surfaces were examined by light microscopy and scanning electron microscopy. RESULTS: The femtosecond laser was successful in producing posterior lamellar and trephination cuts in rabbit eyes. The thickness of the posterior corneal discs was 204.3 +/- 21 microm (56.9% of central corneal thickness), and postoperative keratometry was 49.1 +/- 5.8 D. Clinical appearance consistent with corneal ectasia was noted in 3 eyes. CONCLUSION: The femtosecond laser can make nonmechanical cuts for posterior lamellar keratoplasty with relative ease and reliability in rabbit eyes. A minimum residual anterior corneal thickness may need to be maintained to prevent ectasia.

Animals↗

Bone marrow biopsy morbidity: review of 2003.

BACKGROUND: Although some hazards are recognised, in general, bone marrow aspiration and trephine biopsy are thought to be safe procedures. Until recently, no attempt had been made to quantify any attendant risks. For this reason, documentation of adverse events was begun in 2001, under the auspices of the British Society for Haematology. Three consecutive years have now been surveyed, the results for 2003 being presented here and compared with earlier results. METHODS: Members of the British Society of Haematology were requested to document adverse events associated with diagnostic bone marrow aspirates and trephine biopsies between 1 January and 31 December, 2003. Data were collected early in 2004. RESULTS: In total, 19,259 procedures were reported from 63 hospitals, 13,147 being combined procedures and 6112 aspirates without a trephine biopsy. Sixteen adverse events were reported, representing 0.08% of total reported procedures. The major adverse event was haemorrhage, which comprised 11 of the 16 adverse events. Although infrequent, adverse events were associated with significant morbidity and three were judged as very serious. The major risk factors for haemorrhage, in order of frequency, were diagnosis of a myeloproliferative disorder, aspirin treatment, other putative platelet dysfunctions, and thrombocytopenia. CONCLUSIONS: Adverse events following trephine biopsies and bone marrow aspirates are rare, but nevertheless can have considerable impact on individual patients.

Biopsy, Needle↗

Excisional biopsy of skin tumors.

The most frequently encountered neoplasm in the US is skin cancer. More than 600,000 new cases of malignant skin tumors are diagnosed in the US each year. One standard method of treatment of skin tumors is excisional biopsy. There are seven technical considerations involved in the excisional biopsy of skin tumors: (1) aseptic technique, (2) examination and demarcation of skin lesion, (3) skin biomechanical properties, (4) anesthesia, (5) excisional biopsy, (6) wound closure, and (7) postoperative care. The physician must use aseptic techniques and wear a cap, mask, and powder-free gloves. Hair is a source of wound contamination, and removal of hair prevents it from becoming entangled in suture and the wound during closure. Because surgical electric clippers cut hair close to the skin surface without nicking the skin, we now use only electric clippers to remove hair. The physician's visualization of the wound can be enhanced by magnification (2.5x) loupes. The physician's plan for excisional biopsy is dictated by the suspected pathology of the skin lesion. The ultimate appearance and function of a scar after closure of excisional biopsy can be predicted by the static and dynamic skin tensions on the surrounding skin. Infiltration anesthesia is preferred over regional nerve block because it does not interfere with the muscle movement that causes dynamic tensions, which elongate the configuration of the defect. Most skin lesions are amenable to a circular excision. In these instances, it is worthwhile to use circular-shaped excisions. The reusable metal trephines have been replaced by disposable trephines that have ribbed plastic handles attached to 316 stainless steel circular cutting blades. Wound closure is accomplished in the same direction as the long axis of the elliptical defect by first approximating the midportion of the defect with a 4-0 synthetic CAPROSYN* monofila-ment absorbable suture attached to the swage of the laser-drilled, compound-curved reverse cutting edge needle. Additional interrupted dermal (subcuticular) sutures are placed in each wound quadrant to approximate further the divided edges of the dermis. Compound-curved reverse cutting edge needles have been specifically designed for dermal closure. Reinforced Steri-Strips are then applied transversly across the incision to facilitate further skin edge approximation. Rigorous follow-up examination is essential for any patient with a history of a skin cancer to detect recurrence and prevent further actinic damage. The use of wide diameter trephine biopsy instruments are still not widely used by physicians because most physicians do not have the technical skills to approximate the defect with dermal sutures. Consequently, this need for a rapid dermal skin closure technique that can be used by a primary care physician must be devised before the trephine excisional biopsy technique is widely used by the primary care physician. This goal can be achieved by developing a disposable stapler for subcuticular closure of the skin.

Anesthesia, Local↗

Comparison of two methods for the removal of root canal posts.

OBJECTIVE: To compare the application of ultrasound with the use of an engine-driven trephine bur to remove parallel-sided root canal posts. METHOD AND MATERIALS: Single-rooted human canine teeth were decoronated and prepared to receive preformed titanium posts. The posts were cemented with Panavia F resin cement. Ten teeth acted as controls, 10 had a 4-mm-deep gutter cut around the post using a Masserann trephining bur, and 10 were subjected to 10 minutes of ultrasound. The forces required to dislodge the posts were determined using a universal testing machine, and the data were analyzed using analysis of variance. RESULTS: The only significant difference was between the trephined and ultrasonically energized groups, with the ultrasonic group requiring greater forces for dislodgement. CONCLUSION: Resin composite cement could be removed from around the posts with the trephine bur but with considerable difficulty, and neither method of dislodging the posts was effective.

Analysis of Variance↗

[Applying deep lamellar keratoplasty in corneal disorders without endothelial abnormalities].

PURPOSE: To present own experiences in the surgery of deep lamellar keratoplasty. MATERIALS AND METHODS: 25 eye of 25 patients suffering from various corneal pathologies with preserved endothelium: 22 with keratoconus eyes, 2 with post-inflammatory scar and one eye with leucoma in Stevens-Johnson syndrome. Mean follow-up was 25.5 months (from 6 to 32). Main outcome measures were Non-Corrected and Best Corrected Visual Acuity (NCVA, BCVA), astigmatism, refractive error, IOP and corneal transparency. The surgery was performed in general anesthesia. In majority of cases the recipient stroma was trephined to a depth of 70% with 7.5 mm diameter vacuum trephine. In cases of intraoperative perforation of Descemet membrane with shallow anterior chamber we converted the procedure into penetrating keratoplasty. The donor lenticule was trephined in the artificial chamber with the 0.5 mm oversized manual trephine to a depth of 90%. In two cases after DLK was finished, limbal stem cell grafting was additionally performed. RESULTS: Postoperative NCVA ranged from 0.01 to 0.8 and BCVA from 0.1 to 0.8. Astigmatism ranged from 0.5 to 10.0 D. Refractive error ranged from -8.0 to +1.0 D. In follow-up period all grafts maintained transparent. The complications were mainly intraoperative perforations of Descemet membrane (9 cases): in 7 cases we convert the procedure into penetrating keratoplasty. In 2 cases the double chamber-forming was observed: in one case on 7 day following surgery the penetrating keratoplasty was performed, in other a spontaneous attachment was observed. We also observed loose sutures in 2 cases, inflammatory infiltrates in one case. Two cases of ocular hypertension was successfully treated by medication. CONCLUSIONS: Deep lamellar keratoplasty is an effective procedure for treating various diseases of corneal stroma with unaffected endothelium.

Adult↗