Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SUTURES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Lateral tunnel suture line variation reduces atrial flutter after the modified Fontan operation.

BACKGROUND: Atrial flutter (AFL) is a common postoperative sequela of the modified Fontan operation, or total cavopulmonary connection. We hypothesized that injury to the crista terminalis (CT) by the lateral tunnel suture line contributes to the development of AFL in this setting. This study was designed to determine the effects of alteration of the lateral tunnel suture line, relative to the CT, on the inducibility of AFL in an acute canine model of the modified Fontan operation. METHODS: Adult mongrel dogs (n = 25) underwent a median sternotomy and normothermic cardiopulmonary bypass. In groups 1, 2, and 3, through a right atriotomy, a suture line was placed to simulate the lateral tunnel of the modified Fontan operation (n = 20). The lateral aspect of the suture line ran along the CT in group (n = 10), 5 mm medial to the CT in group 2 (n = 5), and 10 mm anterior to the CT, incorporated into the atriotomy closure, in group 3 (n = 5). In group 4 (n = 5), only the lateral portion of the suture line, along the CT, was placed. Form-fitting 253-point unipolar endocardial mapping electrodes were inserted in the left and right atria via bilateral ventriculotomies. Induction of AFL was then attempted using atrial burst pacing. If sustained AFL could not be induced, isoproterenol was administered and the pacing protocol repeated. Endocardial activation sequence maps of spontaneous rhythm and AFT were constructed. RESULTS: Under baseline conditions, after placement of the suture line, sustained AFL could reproducibly be induced in 8/10 dogs in group 1, 0/5 dogs in group 2, 0/5 dogs in group 3, and 5/5 dogs in group 4 (p < 0.001). After isoproterenol administration, sustained AFL was reproducibly inducible in the remaining 2 dogs in group 1, 4/5 dogs in group 2, and 0/5 dogs in group 3 (p = 0.01). The mean cycle length of AFL was 189 +/- 25 ms in group 1, 136 +/- 8 ms in group 2, and 182 +/- 20 ms in group 4 (p < 0.001). Atrial activation sequence maps, during sinus rhythm, demonstrated a line of conduction block along the lateral portion of the suture line in all cases in groups 1 and 4 and in only those cases in group 2 in which sustained AFL was inducible. During AFL this block facilitated unidirectional conduction, permitting propagation of the reentrant wavefront. Mean conduction velocity along the CT during sinus rhythm was 0.63 +/- 0.10 m/s in group 1, 1.04 +/- 0.17 m/s in group 2, 1.01 +/- 0.12 m/s in group 3, and 0.44 +/- 0.13 m/s in group 4 (p < 0.01). CONCLUSIONS: In an acute canine model of the modified Fontan operation, conduction block imposed by the lateral tunnel suture line is an essential component of the AFL circuit. The inducibility of AFL is increased by suture line placement along the CT. Slow conduction, resulting from injury to the CT, promotes this increased inducibility. Avoidance of the CT may reduce the incidence of AFL in children undergoing the modified Fontan operation.

Animals↗

The effects of laser-assisted fibrinogen bonding on suture material.

To evaluate the effect of laser-assisted fibrinogen bonding on the tensile strength of suture material, 10 types of sutures were exposed to various time intervals of diode laser energy after pretreatment with dye-enhanced fibrinogen solder. After exposure, each suture material was stressed on a tensometer and compared with nonlased suture material. Our results indicate that polytetrafluoroethylene suture material was virtually unaffected at all time intervals of exposure to laser energy. Polyester suture material retained 64.3% of its tensile strength at 60 sec of exposure to laser energy. White silk suture material maintained 80% of its initial tensile strength at 60 sec of exposure. These suture materials may be used safely in conjunction with laser-assisted fibrinogen bonding even if prolonged laser exposure is necessary. The other suture materials tested may be compromised significantly by prolonged exposure to laser energy and must be used with relatively shorter irradiation periods.

Biocompatible Materials↗

Glenohumeral volume reduction in arthroscopic shoulder reconstruction: a cadaveric analysis of suture plication and thermal capsulorrhaphy.

PURPOSE: The purpose of this study was to objectively assess glenohumeral volume changes after arthroscopic suture plication, arthroscopic thermal capsulorrhaphy, and combined suture and thermal treatment. TYPE OF STUDY: Cadaveric study. METHODS: Five matched pairs of cadaver shoulders were treated with either thermal capsulorrhaphy (n = 5) or arthroscopic suture plication (n = 5). The shoulders treated with plication were then treated with thermal capsulorrhaphy to form a combined treatment group (plication and thermal). Preoperative and postoperative glenohumeral volume measurements were obtained, and the techniques were statistically compared with a 1-factor analysis of variance. RESULTS: All 3 procedures produced marked decreases in glenohumeral capsular volume. Suture plication reduced intra-articular volume an average of 19.0%. Thermal capsulorrhaphy resulted in a mean capsular volume reduction of 33.4%. Combined treatment with suture plication and thermal capsulorrhaphy reduced glenohumeral volume an average of 41.0%. Both thermal capsulorrhaphy and the combined treatment produced significantly greater reduction in glenohumeral volume than plication alone (P <.0001). Although combined suture plication and thermal capsulorrhaphy resulted in greater reduction in capsular volume than thermal capsulorrhaphy alone, the differences were not statistically significant. CONCLUSIONS: Our results indicate that arthroscopic suture plication and thermal capsulorrhaphy are both effective in reducing glenohumeral intra-articular volume. Thermal capsulorrhaphy alone or in combination with suture plication led to significantly greater reduction in capsular volume when compared with isolated suture plication.

Aged↗

Cyclic loading of rotator cuff repairs: an in vitro biomechanical comparison of bioabsorbable tacks with transosseous sutures.

PURPOSE: This study compares rotator cuff repair strength after cyclic loading of bioabsorbable tacks and traditional transosseous sutures, and correlates the results with bone density, age, and gender. The hypotheses were that tack repair strength would be inferior to transosseous sutures and that repair strength would be directly related to bone quality. TYPE OF STUDY: In vitro randomized biomechanical study. METHODS: Eight paired cadaveric shoulders with a standardized supraspinatus defect were randomized to tack or suture repair and subjected to step-wise cyclic loading. Repair migration was measured by quantifying the motion of markers affixed to tendon and bone using a digital camera. Failure mode, cycles, and load were measured for 50% and 100% loss of repair. Results were correlated with bone density, age, and gender. RESULTS: Tack repairs failed at the tack-tendon interface, whereas suture rupture was the mode of failure for the suture repairs. Mean values for 50% loss of repair were 206 +/- 88 cycles and 44 +/- 15 N for the sutures, and 1,193 +/- 252 cycles and 156 +/- 20 N for the tacks (P < .05). The corresponding values for 100% loss of repair were 2,458 +/- 379 cycles and 294 +/- 27 N for the sutures, and 2,292 +/- 333 cycles and 263 +/- 28 N for the tacks (P > .05). These results did not correlate with bone density, age, or gender. CONCLUSIONS: This study has shown that bioabsorbable tacks provide improved repair strength in comparison with traditional suture techniques. Repair strength did not correlate with bone quality, and this may be attributed to failure primarily through the repair construct or at the tack-tendon interface and not through bone. This report describes a new high-resolution optical method of measuring tendon repair strength that should be a useful model for future studies. CLINICAL RELEVANCE: This study demonstrates the biomechanical advantages of a sutureless tack device for rotator cuff repair compared with a traditional augmented suture repair technique.

Absorbable Implants↗

Arthroscopic all-inside lateral meniscus suture using posterolateral portal.

A new arthroscopic all-inside suture for lateral meniscus posterior horn tear using a single posterolateral portal is described. A lateral meniscus posterior horn peripheral longitudinal tear is often seen with anterior cruciate ligament injury or discoid lateral meniscus tear. Conventional repair methods, such as arthroscopic inside-out, outside-in, or all-inside sutures, can be cumbersome and technically demanding. Our all-inside suture using the posterolateral portal allows thorough visualization of the posterolateral structures, excellent coaptation of torn meniscus, strong knot tightening, and avoidance of inadvertent cartilage injury. The arthroscope is inserted through the anteromedial portal and reaches the posterolateral compartment by a transcondylar approach. A suture hook is introduced into the posterolateral portal without a cannula, penetrates posterior peripheral rim, crosses the tear, and passes through mobile torn fragment. A large amount of No. 0 PDS is passed, so that it curls up inside the joint. After the suture hook is removed, a suture retriever is inserted through the posterolateral portal to pull out 2 ends of the PDS at the same time. The retrieved suture ends are passed through a knot pusher and a 5.5-mm cannula is introduced over the retrieved suture materials for the SMC knot to be tied. A longitudinal tear of lateral meniscus posterior horn is repaired with 2 to 3 sutures.

Adult↗

Development and characterisation of silver-doped bioactive glass-coated sutures for tissue engineering and wound healing applications.

A novel silver-doped bioactive glass powder (AgBG) was used to coat resorbable Vicryl (polyglactin 910) and non-resorbable Mersilk surgical sutures, thereby imparting bioactive, antimicrobial and bactericidal properties to the sutures. Stable and homogeneous coatings on the surface of the sutures were achieved using an optimised aqueous slurry-dipping technique. Dynamic mechanical analysis (DMA) was used to investigate the viscoelastic parameters of storage modulus and tandelta and thermal transitions of the as-received and composite (coated) sutures. The results generally showed that the bioactive glass coating did not affect the dynamic mechanical and thermal properties of the sutures. The in vitro bioactivity of the sutures was tested by immersion in simulated body fluid (SBF). After only 3 days of immersion in SBF, bonelike hydroxyapatite formed on the coated suture surfaces, indicating their enhanced bioactive behaviour. Resorbable sutures with bioactive coatings as fabricated here, in conjunction with 3-D textile technology, may provide attractive materials for producing 3-D scaffolds with controlled porosities for tissue engineering applications. The bactericidal properties imparted by the Ag-containing glass coating open also new opportunities for use of the composite sutures in wound healing and body wall repair.

Absorbable Implants↗

Impaired posterior frontal sutural fusion in the biglycan/decorin double deficient mice.

Biglycan (Bgn) and decorin (Dcn) are highly expressed in numerous tissues in the craniofacial complex. However, their expression and function in the cranial sutures are unknown. In order to study this, we first examined the expression of biglycan and decorin in the posterior frontal suture (PFS), which predictably fuses between 21 and 45 days post-natal and in the non-fusing sagittal (S) suture from wild-type (Wt) mice. Our data showed that Bgn and Dcn were expressed in both cranial sutures. We then characterized the cranial suture phenotype in Bgn deficient, Dcn deficient, Bgn/Dcn double deficient, and Wt mice. At embryonic day 18.5, alizarin red/alcian blue staining showed that the Bgn/Dcn double deficient mice had hypomineralization of the frontal and parietal craniofacial bones. Histological analysis of adult mice (45-60 days post-natal) showed that the Bgn or Dcn deficient mice had no cranial suture abnormalities and immunohistochemistry staining showed increased production of Dcn in the PFS from Bgn deficient mice. To test possible compensation of Dcn in the Bgn deficient sutures, we examined the Bgn/Dcn double deficient mice and found that they had impaired fusion of the PFS. Semi-quantitative RT-PCR analysis of RNA from 35 day-old mice revealed increased expression of Bmp-4 and Dlx-5 in the PFS compared to their non-fusing S suture in Wt tissues and decreased expression of Dlx-5 in both PF and S sutures in the Bgn/Dcn double deficient mice compared to the Wt mice. Failure of PFS fusion and hypomineralization of the calvaria in the Bgn/Dcn double deficient mice demonstrates that these extracellular matrix proteoglycans could have a role in controlling the formation and growth of the cranial vault.

Alcian Blue↗

Supplementary core sutures increase resistance to gapping for flexor digitorum profundus tendon to bone surface repair - an in vitro biomechanical analysis.

We evaluated the effects of two types of supplementary core sutures on the tensile properties and resistance to gap formation of flexor digitorum profundus (FDP) tendon-bone repairs. Forty-five human cadaver FDP tendons were sharply released from their insertion sites and repaired to bone utilizing one of three repair techniques: four-strand modified Becker core suture (Becker only), modified Becker plus a figure-of-eight supplementary core suture (Becker plus figure-of-eight), and modified Becker plus a supplementary core suture using a bone anchor (Becker plus anchor). Ultimate (maximum) force did not differ between repair groups. However, addition of a supplementary suture significantly increased repair-site stiffness and the 1, 2 and 3 mm gap forces, while decreasing the gap at 20 N compared to the Becker only suture (P<0.05). The only difference between the two supplementary suture groups was that the Becker plus anchor group had increased stiffness compared to the Becker plus figure-of-eight group. In conclusion, a supplementary figure-of-eight suture and a supplementary suture using a bone anchor provide enhanced resistance to gap formation for FDP tendon-bone repairs.

Adult↗

Facial nerve repair with epineural suture and anastomosis using fibrin adhesive: an experimental study in the rabbit.

PURPOSE: An experimental model in rabbits was used to compare epineural suturing and fibrin adhesive anastomosis for facial nerve repair. MATERIALS AND METHODS: Thirty-four facial nerves from 17 rabbits were isolated, transected, and anastomosed, with an evaluation of their electrophysiologic and histologic parameters. The rabbits were divided into 2 groups of 5 and 12 animals, respectively: a 10-mm defect was made in the right facial nerve in the first group, with transection and epineural suturing of the left nerve, followed by death after 120 days. This was the control-versus-epineural suture group. In the second group, the right facial nerve was transected and subjected to epineural suturing, while the left nerve was transected and anastomosed using fibrin adhesive. The rabbits were killed 15, 30, 60, and 120 days after the microsurgical procedure. This was the epineural suture-versus-fibrin adhesive group. RESULTS: From day 30, the number of regenerated axons increased with time in the epineural suture and fibrin adhesive anastomotic specimens. Epineural suture showed more regenerated axons and a faster linear rate of regeneration than anastomosis with fibrin adhesive. The reduction in conduction velocity decreased significantly with time with the same linear pattern for both suture techniques. CONCLUSIONS: Epineural suturing offered superior performance versus anastomosis with fibrin adhesive in terms of axon count but not in decrease in conduction velocity.

Anastomosis, Surgical↗

Feasibility study of a mechanical suturing device for less invasive mitral operations.

BACKGROUND: Because of smaller incisions and limited exposure, less invasive operations on the mitral valve can be arduous and time-consuming. This study examined the feasibility of a mechanical suturing device to facilitate less invasive mitral replacement. METHODS: Five mongrel dogs underwent limited left thoracotomy. After conventional cardiopulmonary bypass and cardioplegia, the mitral valve was exposed through a left atriotomy. After excision of the anterior leaflet, subannular sutures were placed using a mechanical suturing device. This device simultaneously passes two ends of a pledgeted 2-0 braided suture through the valvular annulus, then mechanically grasps both needles on the atrial aspect. Hence, a mattress suture is accomplished one-handed in a single continuous motion. This procedure was repeated around the entire annulus. A mechanical valve was seated and the sutures were tied and cut. RESULTS: All mechanical valves were implanted successfully. In the 4 animals in which it was attempted, cardiopulmonary bypass was successfully weaned. No evidence of perivalvular leak was observed by echocardiography. CONCLUSIONS: These data establish the feasibility of a mechanical suturing device for operations on the mitral valve. The device is easily mastered, maintains precise spacing between sutures, and permits rapid placement of mattress sutures. We predict widespread application for both less invasive and conventional valve operations.

Animals↗

[Randomized clinical study of polydioxanone and nylon sutures for laparotomy clousure in high-risk patients].

INTRODUCTION: The complications of surgical wound closure in patients with risk factors significantly increases morbidity and mortality. The aim of the present study was to evaluate differences in abdominal wall closure in patients with risk factors with the same closure technique and slow-absorbable or non-absorbable sutures. MATERIAL AND METHODS: We performed a prospective, multicenter, comparative study of polydioxanone versus nylon sutures. Laparotomies performed for intestinal diseases and hepatobiliopancreatic procedures in patients with at least one risk factor were included. Exclusions criteria were eventrations, interventions for obesity, the need for reinforcement sutures, uncommon incisions, life expectancy of less than 1.5 years and deaths unrelated to the wound. Closure was performed with monoplane, extracutaneous, continuous, en bloc, loop sutures. Infection, evisceration, dehiscence, extrusion, sinus, eventration, intolerance, and pain were evaluated. Postoperative follow-up was performed at 10 and 30 days, 3 and 6 months, and at 1 and 1.5 years. RESULTS: A total of 770 patients were included (451 in the polydioxanone group and 319 in the nylon group). A total of 78.05% were midline incisions, with a mean length of 23.3 cm. Caliber 1 sutures were most frequently used (85.45%), and 1.7 sutures were used per patient. No complications occurred in 94.03% with no differences between groups (94.7% polydioxanone and 93.1% nylon). The results were similar throughout follow-up. The surgical infection rate was 10%. No differences were found in any of the follow-up assessments in any of the variables analyzed. CONCLUSIONS: Abdominal wall closure should be performed with continuous slow-absorption sutures such as polydioxanone since this type of suture has a similar complication rate to reabsorbable sutures and presents greater biocompatibility.

Female↗

Endoscopic suturing without extracorporeal knots: a laboratory study.

BACKGROUND: To eliminate cumbersome extracorporeal knotting, we designed a new endoscopic suturing device, the Eagle Claw V. The efficacy of the new device was tested on the Erlangen model and was compared with the initial extracorporeal knotting version (Eagle Claw II). METHODS: Segments of porcine splenic arteries were placed on the mucosal surface of the anterior wall of a pig stomach. The two ends of the artery were brought out through the gastric wall and were connected to a two-channel manometer. The Eagle Claw V has a curved needle with a detachable tip. After puncturing the tissue, the needle tip was engaged into a catching cartridge, where the suture had been embedded in a tightening mechanism. The suture could be tightened by simply pulling the end. The Eagle Claw V was used to plicate the splenic arteries mounted on the stomach. Suturing was considered secure if the suture could withstand endoluminal pressure greater than 200 mm Hg that lasted at least 10 seconds. RESULTS: Eleven of 15 stitches (73.3%) gained secure plication of the vessels. The suturing time (mean +/- standard deviation 2.93 +/- 0.80 minutes) was significantly faster than that of the Eagle Claw II (9.38 +/- 1.51 minutes). The device consistently achieved penetration of the muscular layer, and 4 of 15 sutures included the serosa. The 4 failures were because of suture breakage in two, thread entanglement in one, and cartridge dislodgement in one. CONCLUSIONS: The present prototype represents significant improvements in the ease of operation and the security of the suture, bringing the technique closer to clinical use for a variety of applications.

Animals↗

Superiority of electrocautery over the suture method for achieving cervical cone bed hemostasis.

OBJECTIVE: To compare the efficacy of electrocautery with that of the suture method for achieving hemostasis of the cervical cone bed. METHODS: We performed a retrospective chart review of all patients who underwent cold-knife conization of the cervix over a 5-year period. Patients were categorized into two groups: the cautery group, in which the cone bed was electrocauterized with a hand-held electrocoagulation device; and the suture group, in which hemostasis was achieved by a continuous locking suture placed circumferentially around the cone bed. Outcome measures evaluated include estimated blood loss, operative time, and incidence of complications, including secondary hemorrhage, cervicitis, and cervical stenosis. Data were analyzed by Student t test, chi(2) test, linear regression, and multiple logistic regression where appropriate. RESULTS: There were 156 women in the cautery group and 35 in the suture group. The cautery group had significantly lower estimated blood loss (27 mL versus 101 mL; P <.01) and shorter operative time (34 versus 43 minutes; P <.01) than the suture group. The procedure-related complication rate was 6.4% in the cautery group, compared with 14.3% in the suture group (P = nonsignificant). A higher use of lateral sutures, vasopressors, and thrombotic agents was seen in the cautery group. However, even after adjusting for these variables, mean estimated blood loss (33 mL, P <.01) and mean operative time (34 minutes, P <.01) were significantly less in the cautery group than in the suture group. CONCLUSIONS: Cauterization of the cone bed is superior to suture as a method of achieving hemostasis, with significantly less blood loss and shorter operative time.

Adult↗

Impact of graft diameter on corneal power and the regularity of postkeratoplasty astigmatism before and after suture removal.

OBJECTIVE: To assess the impact of graft diameter on corneal curvature before and after removal of a double-running suture after nonmechanical penetrating keratoplasty (PK). DESIGN: Prospective, nonrandomized, comparative (self-controlled) single-center clinical trial. PATIENTS: Four hundred eighty-nine eyes with "two sutures in" and 308 eyes with "all sutures out" (mean age, 52+/-19 years) were included. The diagnoses were keratoconus (48%), Fuchs' and stromal dystrophies (31%), aphakic or pseudophakic bullous keratopathy (11%), and scars (10%). INTERVENTIONS: In all eyes, a central trephination was performed (donor trephination from the epithelial side) using the 193-nm Meditec excimer laser (Carl Zeiss Meditec, Jena, Germany) along metal masks with eight "orientation teeth/notches." Diameters were 8.0 mm, 7.5 mm, and 7.0 mm with a graft oversize of 0.1 mm. In 29% of eyes, additional cataract, intraocular lens surgery, or both were performed simultaneously. In all eyes, a double-running 10-0 nylon suture was applied. Zeiss keratometry and TMS-1 topography analysis were performed before removal of the first suture (14+/-4 months) and at least 6 weeks after removal of the second suture (20+/-4 months), but before any additional surgery, such as cataract extraction or refractive keratotomies. MAIN OUTCOME MEASURES: Topographic central corneal power (CP; keratometric diopters), keratometric astigmatism (KA), surface regularity index (SRI), and surface asymmetry index (SAI). The regularity of keratometry mires was recorded semiquantitatively from 0 = regular to 3 = not measurable (as published earlier). RESULTS: With both sutures in, median CP in 7.0-mm (42.0 diopters [D]; P = 0.04) and in 7.5-mm grafts (42.3 D; P = 0.007) was significantly lower than in 8.0-mm grafts (43.0 D). Keratometric astigmatism did not differ between groups (3.0 D vs. 3.0 D vs. 2.7 D). The SRI (1.66 vs. 1.43 vs. 1.11) and SAI (1.55 vs. 1.24 vs. 0.85) decreased significantly with increasing diameter. The proportion of regular keratometry mires (13% vs. 17% vs. 29%) increased, and the proportion of not measurable keratometries (45% vs. 18% vs. 9%) decreased with increasing diameter. With all sutures out, CP in 7.0-mm grafts (40.4 D) was significantly smaller than in 7.5-mm (43.6 D; P = 0.04) and 8.0-mm grafts (43.3 D; P = 0.04). Again, KA did not differ between groups (3.0 D vs. 3.2 D vs. 3.0 D). The SRI (1.40 vs. 1.09 vs. 0.84) and SAI (1.24 vs. 0.83 vs. 0.62) decreased significantly with increasing diameter. The proportion of regular keratometry mires (5% vs. 31% vs. 52%) increased, and the proportion of not measurable keratometries (42% vs. 11% vs. 4%) decreased with increasing diameter. CONCLUSIONS: After PK, a smaller graft diameter results in a flatter curvature and a higher degree of topographic irregularity, but not in higher net astigmatism. After suture removal, graft topography tends to regularize, whereas the principal differences between diameters do persist.

Adult↗

Late argon laser suture lysis after mitomycin C trabeculectomy.

BACKGROUND: Argon laser suture lysis has been effectively used in the early post-operative period to enhance filtration after trabeculectomy. The most substantial reductions in intraocular pressure (IOP) occur when laser suture lysis is performed during the first 2 postoperative weeks, and virtually no effect has been reported after the fourth postoperative week. Mitomycin C, used as adjunct therapy, improves the success rate of trabeculectomy in high-risk eyes and may change the time course for effective suture lysis. METHODS: The authors used late laser suture lysis in five high-risk patients after mitomycin C trabeculectomy. The mean patient age was 66.8 +/- 15.7 years, and laser suture lysis was performed an average of 13 +/- 5.8 weeks (range, 7-21 weeks) after surgery. RESULTS: The mean IOP before suture lysis was 20.2 +/- 3.8 mmHg. The average IOP reduction immediately after suture lysis was 11.4 +/- 3.9 mmHg. The average IOP 3 to 4 months after laser suture lysis was 9.4 +/- 3.4 mmHg. CONCLUSION: The authors postulate that adjunctive mitomycin C therapy markedly delays wound healing and appears to extend the period that laser suture lysis is clinically effective.

Adult↗

Randomized clinical trial comparing astigmatism and visual rehabilitation after penetrating keratoplasty with and without intraoperative suture adjustment.

PURPOSE: The authors performed a prospective, randomized clinical trial to compare postoperative astigmatism and visual rehabilitation after penetrating keratoplasty with and without intraoperative suture adjustment. METHODS: Twenty-five patients undergoing penetrating keratoplasty for avascular corneal pathology randomly were assigned to two groups. All surgery was performed by one surgeon (ONS) using the same technique (except for intraoperative suture adjustment) with Hanna trephination (8 mm) and a running 10-0 nylon suture. Postoperative suture adjustment was done during the first postoperative month in all patients who had more than 3.5 diopters of astigmatism. Refraction and computerized topographic analysis were performed at 1 and 6 months postoperatively. RESULTS: Intraoperative suture adjustment significantly decreased postkeratoplasty topographic (P = 0.0001) and refractive (P = 0.0001) astigmatism and improved best spectacle-corrected visual acuity (P = 0.0019) during the first postoperative month. Seventy-seven percent of control patients (mean topographic astigmatism, 4.89 +/- 1.99 D at 1 month), but no patients who underwent intraoperative suture adjustment (mean topographic astigmatism, 1.50 +/- 0.74 D at 1 month), required at least one postoperative suture adjustment that delayed optical stability and increased postoperative complications. At 6 months postoperatively, mean topographic (P = 0.06) and refractive (P = 0.0001) astigmatism were smaller in the intraoperatively adjusted group than in the control group with postoperative suture adjustments. After intraoperative adjustment, best spectacle-corrected visual acuity was better (P = 0.0168, P = 0.0434) and corneal topography was more regular (P = 0.02, P = 0.07, NS) at 1 and 6 months, respectively, than after postoperative adjustment. CONCLUSION: Visual rehabilitation with decreased postkeratoplasty astigmatism and more regular corneal topography was attained more rapidly and safely with intraoperative suture adjustment.

Adult↗

Comparison of tensile strength of cyanoacrylate tissue adhesive closure of lacerations versus suture closure.

STUDY OBJECTIVE: To compare the tensile strength of lacerations closed with cyanoacrylate tissue adhesive, with suture, and with a combination of tissue adhesive and suture. DESIGN: Randomized, controlled animal model study. SETTING: Animal care facility. PARTICIPANTS: Sixteen albino guinea pigs. INTERVENTIONS: Four incisions to deep fascia were created on the dorsum of each animal. Lacerations were closed with either tissue adhesive alone, tissue adhesive with subcutaneous suture, percutaneous suture alone, or percutaneous suture with subcutaneous suture. After 4 days, the breaking strengths of all wound closures were measured. RESULTS: Wound closures made with cyanoacrylate tissue adhesive alone exhibited significantly less tensile strength at 4 days than closures made by the other three methods. Wound closures made with combined percutaneous and subcutaneous sutures were significantly stronger than all other groups. CONCLUSION: Wound closures made with cyanoacrylate tissue adhesive alone have less tensile strength at 4 days than those made with tissue adhesive and subcutaneous suture or those closed by traditional suture methods.

Animals↗

A surgical simulation system of skin sutures using a three-dimensional finite element method.

OBJECTIVE: To establish a surgical simulation system of skin sutures using a three-dimensional finite element method. DESIGN: Three-dimensional finite element models were developed from point data obtained with a rapid three-dimensional surface-measuring device and postoperative profiles were evaluated using these models. BACKGROUND: Since suturing a wound may result in undesirable skin extrusion, it is important to make the extrusion as inconspicuous as possible. We have investigated a means of determining appropriate suture methods to decrease the extrusion. METHODS: Affected body parts were measured non-invasively with a rapid three-dimensional surface-measuring device. Finite element models were prepared, and an appropriate method for reducing skin extrusion was evaluated by attempting various suturing methods. RESULTS: Two kinds of finite element models were prepared: a conventional spindle model and a modified S-shape model. The height of the extrusion of the modified S-shape model was decreased by 40% in comparison with that of the spindle model. These results agreed with clinical findings. CONCLUSIONS: Due to this surgical simulation system of skin sutures, with a rapid three-dimensional surface-measuring device and three-dimensional finite element analysis, it was possible to design an appropriate suturing method and to evaluate the postoperative skin profiles. The modified S-shape suture method would be a recommendable method. RELEVANCE: Using this surgical simulation system of skin sutures, a surgeon can evaluate an appropriate suturing method before operation. It is expected that this system will reduce a surgeon's labor.

Computer Simulation↗