Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Vascular and morphologic changes in canine femora after uncemented hip arthroplasty.

The effects on femoral remodeling of medullary reaming and insertion of a porous endoprosthesis in uncemented hip arthroplasty (UHA) were measured. A unilateral hip hemiarthroplasty (HA) was performed in 12 dogs, with six dogs receiving full-sized and six dogs receiving undersized femoral endoprostheses. A prosthetic head and neck, or acetabular cup, was not implanted. A control group of six dogs underwent femoral head and neck excision (FHNE) only. All dogs were killed 4 weeks after the surgical procedure. Porosity, vascularity, and bone formation were quantified in each femur of the dogs that had been operated on and in each femur of two unoperated dogs. Full-sized did not differ from undersized HA bones in vascularity, porosity, or bone formation. Femurs in which hemiarthroplasties had been performed (full-sized and undersized) had a three-fold increase in porosity, vascularity, and bone formation compared to the contralateral and the FHNE femurs. Changes in porosity and vascularity were greatest (p < .05) at the metaphyseal level and in the medial and caudal quadrants. There was a strong correlation (R2 0.77 to 0.93, and p = .0001) between the increase in porosity and vascularity. These results support the hypothesis that medullary reaming followed by uncemented prosthetic stem implantation contribute to remodeling of the proximal portion of the femur after UHA.

Animals↗

Force-time curves of a rotary tablet press. Interpretation of the compressibility of a modified starch containing various amounts of moisture.

On a rotary tablet press, the force-time curves are segmented into three phases: the compression phase, the dwell phase during which both stress and strain are variable for plastically deforming materials and the decompression phase. The following seven parameters were investigated: the compression area (A1) and the compression slope (Slc) describing the initial phase, the area ratio (AR) and the peak offset time (t(off)) characterizing the dwell time, the decompression area (A4) and the decompression slope (Sld) describing the terminal phase and the total area under the force-time curve (Atot). AR, t(off), Slc and A1 (the last with limitations) are used for phase-specific allocation of the occurrence of plastic flow, which is found to be a function of compression force and moisture content. Tablet strength, tablet porosity and in-die bulk porosity provide additional information for comprehensive interpretation. The values of A4 for the four starch batches are not significantly different. Sld provides somewhat better information about the elastic compact recovery. In general, however, the short decompression phase seems to be inappropriate for characterization by force-time curve parameters, because it is difficult to separate machine recovery from that of the tablet. Porosity above the porosity limit of the material was found to be a prerequisite for plastic flow within the compact. When the porosity limit is reached, further densification remains elastic and leads to a reduced compact strength during expansion. The area ratio, as a robust in-process control parameter for plastically flowing formulations, is suggested as a means of preventing this effect.

Compressive Strength↗

[Culture of chondrocytes onto poly-DL-lactide scaffoldings: experimental study].

This experimental study was intended to find the possibility of using PDLLA as scaffolds in tissue engineering and to assess the effect of PDLLA scaffolds with different porosity on chondrocytes. Chondrocytes were cultured when they were seeded onto PDLLA scaffolds with different porosity. Under scanning electron microscope, the scaffolds in hydrophila and adsorptivity to chondrocytes and the function of the cells were observed. The chondrocytes were noted to proliferate on PDLLA scaffolds with different porosity, those with 90%-96% porosity being significantly better. So PDLLA can be used as a scaffold in tissue engineering, and the proper porosity of PDLLA scaffolds should be 90% approximately 96%.

Cells, Cultured↗

[Experimental study on bone formation induced by porous HA-beta-TCP bioceramics].

Three types of HA-beta-TCP active bioceramics which have various porosity and porous diameters were implanted into femurs and muscles of dogs. Histological and biomechanical tests proved that the porous HA-beta-TCP could make the active stage of bone formation moved up in bones and induce new bone formation in muscles. The pores were easily filled with new bones in samples which had smaller porous diameter than samples having larger porous diameter. The final strength after accomplishment of repair process was closely related with porosity. In samples with lower porosity, the proportion of organic bone and the strength were also lower, but in samples with higher porosity the proportion of organic bone and the strength were also higher. Up to the fourth month postoperatively, the strength of HA-beta-TCP with proper porous diameter and porosity which had been implanted into bones was as high as that of organic bone.

Animals↗

Effects of pore size in 3-D fibrous matrix on human trophoblast tissue development.

The effects of pore size in a 3-D polyethylene terephthalate (PET) nonwoven fibrous matrix on long-term tissue development of human trophoblast ED27 cells were studied. Thermal compression was used to modify the porosity and pore size of the PET matrix. The pore size distributions in PET matrices were quantified using a liquid extrusion method. Cell metabolic activities, estradiol production, and cell proliferation and differentiation were studied for ED27 cells cultured in the thermally compressed PET matrices with known pore structure characteristics. In general, metabolic activities and proliferation rate were higher initially for cultures grown in the low-porosity (LP) PET matrix (porosity of 0.849, average pore size of 30 microm in diameter) than those in the high-porosity (HP) matrix (porosity of 0.896, average pore size of 39 microm in diameter). However, 17beta-estradiol production and cell differentiation activity in the HP matrix surpassed those in the LP matrix after 12 days. The expression levels of cyclin B1 and p27kip1 in cells revealed progressively decreasing proliferation and increasing differentiation activities for cells grown in PET matrices. Also, difference in pore size controlled the cell spatial organization in the PET matrices and contributed to the tissue development in varying degrees of proliferation and differentiation. It was also found that cells grown on the 2-D surface behaved differently in cell cycle progression and did not show increased differentiation activities after growth had stopped and proliferation activities had lowered to a minimal level. The results from this study suggest that the 3-D cell organization guided by the tissue scaffold is important to tissue formation in vitro.

Blotting, Western↗

Ontogenetic and regional morphologic variations in the turkey ulna diaphysis: implications for functional adaptation of cortical bone.

This study examines relationships between bone morphology and mechanically mediated strain/fluid-flow patterns in an avian species. Using mid-diaphyseal transverse sections of domestic turkey ulnae (from 11 subadults and 11 adults), we quantified developmental changes in predominant collagen fiber orientation (CFO), mineral content (%ash), and microstructure in cortical octants or quadrants (i.e., %ash). Geometric parameters were examined using whole mid-diaphyseal cross-sections. The ulna undergoes habitual bending and torsion, and demonstrates nonuniform matrix fluid-flow patterns, and high circumferential strain gradients along the neutral axis (cranial-caudal) region at mid-diaphysis. The current results showed significant porosity differences: 1) greater osteocyte lacuna densities (N.Lac/Ar) (i.e., "non-vascular porosity") in the caudal and cranial cortices in both groups, 2) greater N.Lac/Ar in the pericortex vs. endocortex in mature bones, and 3) greater nonlacunar porosity (i.e., "vascular porosity") in the endocortex vs. pericortex in mature bones. Vascular and nonvascular porosities were not correlated. There were no secondary osteons in subadults. In adults, the highest secondary osteon population densities and lowest %ash occurred in the ventral-caudal, caudal, and cranial cortices, where shear strains, circumferential strain gradients, and fluid displacements are highest. Changes in thickness of the caudal cortex explained the largest proportion of the age-related increase in cranial-caudal breadth; the thickness of other cortices (dorsal, ventral, and cranial) exhibited smaller changes. Only subadult bones exhibited CFO patterns corresponding to habitual tension (ventral) and compression (dorsal). These CFO variations may be adaptations for differential mechanical requirements in "strain-mode-specific" loading. The more uniform oblique-to-transverse CFO patterns in adult bones may represent adaptations for shear strains produced by torsional loading, which is presumably more prevalent in adults. The micro- and ultrastructural heterogeneities may influence strain and fluid-flow dynamics, which are considered proximate signals in bone adaptation.

Adaptation, Physiological↗

Femoral cementing techniques in total hip replacement.

Clinical studies have shown that second-generation femoral cementing techniques at total hip replacement result in a superior fixation of the femoral stem. In an effort to determine what benefits further developments in cementing techniques would provide, we compared the morphology of the cement mantles produced by traditional finger-packing and gun-insertion techniques. The porosity of the cement mantles was quantified using computerised image analysis. The finger-packing technique caused large air inclusions that resulted in large pores in the substance of the cement mantle, whereas the cement-gun technique did not result in any individual pore with an equivalent diameter greater than 3 mm. The mean porosity of cement mantles prepared using the finger-insertion technique was 8.3%, whereas the mean porosity in gun-prepared mantles was 1.7%. The use of a cement gun significantly reduced the porosity of femoral cement mantles (P = 0.02). Reduction of defects in the substance of the cement mantle may account for the increased survival of femoral prostheses inserted when second-generation techniques were used. Further reduction of the porosity of the cement mantle could not be expected to produce as dramatic a clinical improvement in prosthesis fixation.

Arthroplasty, Replacement, Hip↗

Effect of bed compression on high-performance liquid chromatography columns with gigaporous polymeric packings.

The behavior of chromatographic columns packed with gigaporous, highly cross-linked styrenic particles was investigated for use in protein separation by reversed-phase chromatography at high flow velocities. Stainless-steel columns which were 3.5 or 7.5 cm long and had an inner diameter of 0.46 mm were slurry packed with 8 or 20 mm diameter spherical particles of 4000 A mean pore size by using methanol as the packing fluid. It was found that the conditions employed during the packing process have a dramatic effect on the properties of such columns and that this can be attributed in part to the deformability of the particles. An increase in the packing pressure to approximately 6000 p.s.i. (41 MPa) resulted in a higher mass-transfer efficiency for the column with a concomitant decrease in permeability. This is ascribed to a decrease in the interstitial porosity with increasing packing pressure since the experimentally measured plate heights for these columns were found to agree quantitatively with theoretical predictions that relate changes in the interstitial porosity to intraparticle mass transfer. However, the theoretically derived relationship between porosity, permeability, and efficiency does not hold for columns packed at pressures higher than 6000 p.s.i., in which case the total column porosity was found to be high while the permeability and column efficiency were low. This behavior is explained by the formation of a low-porosity layer of highly compressed particles at the downstream end of the column during high pressure packing so that the assumption of axially uniform column properties used in the theoretical approach leads to very large errors.

Chromatography, High Pressure Liquid↗

Native fibrin gel networks observed by 3D microscopy, permeation and turbidity.

Native fully hydrated fibrin gels formed at different fibrinogen and thrombin concentrations and at different ionic strengths were studied by confocal laser 3D microscopy, liquid permeation and turbidity. The gels were found to be composed of straight rod-like fiber elements that often came together at denser nodes. In gels formed at high fibrinogen concentrations, or with high amounts of thrombin, the spaces between the fibers decreased, indicating a decrease of gel porosity. The fiber strands were also shorter. Gel porosity decreased dramatically in gels formed at the high ionic strengths. Shorter fibers were observed and fiber swelling occurred at ionic strengths above 0.24. Quantitative parameters for gel porosity, fiber mass/length ratio and diameter were also derived by liquid permeation and turbidometric analyses of the gels. Permeation analysis showed that gel porosity (measured as Ks) decreased in gels formed at higher fibrin and thrombin concentrations in agreement with the porosity observed by microscopy. The turbidometric analysis showed good agreement with the permeation data for gels formed at various thrombin concentrations, but supported the permeation data more poorly in gels formed at different fibrinogen concentrations, especially above 2.5 mg/ml. Turbidometric analysis showed that the fiber mass/length ratio and diameter decreased in gels formed at ionic strength up to 0.24, as was seen in the permeation study. However, at higher ionic strengths swelling of the fibers was suggested from the gel turbidity data and this was also indicated by microscopy. These findings are discussed in relation to previous hydrodynamic and electron microscopic studies of fibrin gels.

Fibrinogen↗

Water retention and drainage in different brands of microcrystalline cellulose: effect of measuring conditions.

Interaction between water and microcrystalline cellulose (MCC) measured as retention and cumulative drainage of water (WR% and CDW%) is investigated for unmilled and micronized standard (Avicel and Emcocel) and silicified (Prosolv) MCC brands. A centrifuge method was applied with increasing duration and different porosity and thickness of cylindrical powder beds (specimens), in order to establish optimal determination conditions and quantify alterations in interaction between water and different MCC brands. Also, changes of specimen thickness due to presence of water (swelling) were followed. It was found that the effect of specimen porosity and thickness on water drainage (CDW%) appears to be opposite to that on water retention (WR%), while two patterns of WR% and CDW% change with specimen porosity and thickness can be distinguished depending on the centrifugation time. Also, WR% and CDW% are affected by the MCC brand and the micronization. Unmilled silicified MCC brand (Prosolv) shows significantly lower retention and higher drainage of water compared to standard unmilled brands (Avicel and Emcocel), while differences between the unmilled standard Avicel and Emcocel brands are not easily distinguished. Micronization, in general, increases greatly the WR% and decreases CDW% for all the tested MCC brands, and enhances their differences even between Avicel and Emcocel. Swelling of specimen due to presence of water was observed, which was significantly reduced with the micronization, the specimen porosity, and centrifugation as well, but showed slight variation between the different MCC brands. Values of specimen porosity between 60% and 70%, thickness/diameter ratio between 0.75 and 1.0, and centrifugation time between 5 and 20 min provide optimal measuring settings for comparison of MCC brands.

Cellulose↗

The tensile strength of black bear (Ursus americanus) cortical bone is not compromised with aging despite annual periods of hibernation.

Black bears (Ursus americanus) may not develop disuse osteoporosis during long periods of disuse (i.e. hibernation) because they may be able to maintain bone formation. Previously, we found that cortical bone bending strength was not compromised with age in black bears' tibias, despite annual periods of disuse. Here we showed that cortical bone tensile strength (166-198MPa) also does not decrease with age (2-14 years) in black bear tibias. There were also no significant age-related changes in cortical bone porosity in black bear tibias. It is likely that the ability of black bears to maintain bone formation during hibernation keeps bone porosity low (2.3-8.6%) with aging, notwithstanding annual periods of disuse. This low porosity likely preserves ultimate stress with aging. Female bears give birth and nurse during hibernation; however, we found no significant differences between male and female tensile material properties, mineral content, or porosity. Our findings support the idea that black bears, which hibernate 5-7 months annually, have evolved biological mechanisms to mitigate the adverse effects of disuse on bone porosity and strength.

Aging↗

Parameter and observation importance in modelling virus transport in saturated porous media-investigations in a homogenous system.

This paper evaluates the importance of seven types of parameters to virus transport: hydraulic conductivity, porosity, dispersivity, sorption rate and distribution coefficient (representing physical-chemical filtration), and in-solution and adsorbed inactivation (representing virus inactivation). The first three parameters relate to subsurface transport in general while the last four, the sorption rate, distribution coefficient, and in-solution and adsorbed inactivation rates, represent the interaction of viruses with the porous medium and their ability to persist. The importance of four types of observations to estimate the virus-transport parameters are evaluated: hydraulic heads, flow, temporal moments of conservative-transport concentrations, and virus concentrations. The evaluations are conducted using one- and two-dimensional homogeneous simulations, designed from published field experiments, and recently developed sensitivity-analysis methods. Sensitivity to the transport-simulation time-step size is used to evaluate the importance of numerical solution difficulties. Results suggest that hydraulic conductivity, porosity, and sorption are most important to virus-transport predictions. Most observation types provide substantial information about hydraulic conductivity and porosity; only virus-concentration observations provide information about sorption and inactivation. The observations are not sufficient to estimate these important parameters uniquely. Even with all observation types, there is extreme parameter correlation between porosity and hydraulic conductivity and between the sorption rate and in-solution inactivation. Parameter estimation was accomplished by fixing values of porosity and in-solution inactivation.

Adsorption↗

Scattering of ultrasound in cancellous bone: predictions from a theoretical model.

An understanding of the interaction between acoustic waves and cancellous bone is needed in order to realize the full clinical potential of ultrasonic bone measurements. Scattering is likely to be of central importance but has received little attention to date. In this study, we adopted a theoretical model from the literature in which scattering was assumed to be proportional to the mean fluctuation in sound speed, and bone was considered to be a random continuum containing identical scatterers. The model required knowledge only of sound speeds in bone and marrow, porosity, and scatter size. Predicted attenuation, broadband ultrasonic attenuation (BUA) and backscatter coefficient were obtained for a range of porosities and scatterer sizes, and were found to be comparable to published values for cancellous bone. Trends in predicted BUA with porosity agreed with previous experimental observations. All three predicted acoustic parameters showed a non-linear dependence on scatterer size which was independent of porosity. These data confirm the value of the scattering approach and provide the first quantitative predictions of the independent influence of structure and porosity on bone acoustic properties.

Bone and Bones↗

The determination of fracture mechanics properties of pharmaceutical materials in mode III loading using an anti-clastic plate bending method.

Powder compacts made from acetylsalicylic acid and lactose monohydrate were subjected to an anti-clastic plate bending method in order to obtain the critical stress intensity factor in mode III loading (tearing or antiplane shear mode). The theoretical approach for data processing was based on linear elastic fracture mechanics. In contrast to mode I loading (opening or tensile mode), where above a critical threshold value the critical stress intensity factor is independent of the notch depth, i.e. converts into a true material constant, in mode III loading the critical stress intensity factor could only be presented under strict reference to a defined notch length. For lactose monohydrate, the typical exponential relationship between critical stress intensity factor and plate porosity was found. However, this was not the case for acetylsalicylic acid plates, indicating a change in fracture origin from pores and clusters of pores at higher porosities to machine flaws at low porosities. Hence, no extrapolation to zero porosity was attempted for this material, whereas for lactose monohydrate, the critical stress intensity factor at zero porosity was estimated to be 102+/-14 MNm(3/2). This value is valid for a notch depth of 4.9+/-0.3 mm. From the values obtained for the critical stress intensity factor and the critical strain energy release rate in mode III loading and an anisotropy ratio, here defined as the ratio between the critical stress intensity factors obtained in mode I and mode III loading, it was concluded that acetylsalicylic acid is the more brittle material and that lactose monohydrate behaved rather ductile under the given experimental conditions.

Anti-Inflammatory Agents, Non-Steroidal↗

Decline in osteocyte lacunar density in human cortical bone is associated with accumulation of microcracks with age.

Despite osteocytes' ideal position to sense the local environment and thereby influence bone remodeling, the function of osteocytes in bone remains controversial. In this study, histomorphometric examination of male and female femoral middiaphyseal cortical bone was conducted to determine if bone's remodeling response, indicated by tissue porosity and accumulation of damage, is associated with osteocyte lacunar density (number of osteocyte lacunae per bone area). The results support the sensory role of the osteocyte network as the decline in osteocyte lacunar density in human cortical bone is associated with the accumulation of microcracks and increase in porosity with age. Porosity and microcrack density increased exponentially with a decline in osteocyte lacunar density indicating that a certain minimum number of osteocytes is essential for an "operational" network. No gender-related differences were found in the relationship of osteocyte lacunar density to age, porosity, or microcrack density. The coefficient of variation of osteocyte lacunar density increased linearly with age, indicating that aging bone tissue is characterized by increased heterogeneity in the spatial organization of osteocytes. Osteocyte lacunar density, porosity, and microcrack density exhibited the same exponential probability density distribution in the donor population, indicating their regulation by similar biological phenomena.

Adolescent↗

Aging and accumulation of microdamage in canine bone.

Fractures associated with minimal trauma are common in aged human beings. However, bone safety margins are better preserved in aged dogs, which are rarely affected with minimal trauma fractures. Although the hierarchical architecture of canine and human compact bone is similar, the precise reasons for this species difference are unclear. Cyclic loading of bone during normal daily activity leads to the formation of microcracks within the tissue matrix of compact bone. Using a standard bulk-staining technique with basic fuchsin, we examined calcified transverse sections of the mid-diaphysis of the canine humerus from dogs of varying ages. We found that the amount of microdamage and porosity increased exponentially with aging, although the increases were relatively small, compared with human bone. Gender (female, ovariohysterectomized female, male, castrated male) did not have a significant effect on the amount of microdamage or porosity in bone. Alterations to the local material properties of bone tissue, or alterations to the local tissue repair responses, may play a role in the accumulation of microdamage in bone with aging. Determination of osteocyte lacunar density (number of osteocyte lacunae per bone area) and activation frequency (number of actively remodeling osteons per bone area per year) indicated that these variables declined exponentially with aging. There also was a trend for bone from dogs with low osteocyte lacunar density to have a higher microcrack density, but not higher porosity. Furthermore, bones with a high activation frequency did not accumulate microcracks or porosity. Taken together, these data suggest that, in canine bone, although a certain minimum number of osteocytes may be essential for an operational network that forms part of the signaling pathways that orchestrate repair of bone microdamage, increases in porosity with aging may not be directly associated with impaired function of the osteocyte network within bone.

Aging↗

Correlation of bone mineral density with strength and microstructural parameters of cortical bone in vitro.

The aim of this study was to evaluate the influence of microstructural parameters, such as porosity and osteon dimensions, on strength. Therefore, the predictive value of bone mineral density (BMD) measured by quantitative computed tomography (QCT) for intracortical porosity and other microstructural parameters, as well as for strength of cortical bone biopsies, was investigated. Femoral cortical bone specimens from the middiaphysis of 23 patients were harvested during total hip replacement while drilling a hole (dia. 4.5 mm) for the relief of the intramedullary pressure. In vitro structural parameters assessed in histological sections as well as BMD determined by quantitative computed tomography were correlated with yield stress, and elastic modulus assessed by a compression test of the same specimens. Significant correlations were found between BMD and all mechanical parameters (elastic modulus: r = 0.69, p < 0.005; yield stress: r = 0.64, p < 0.005). Significant correlations between most structural parameters assessed by histology and yield stress were discovered. Structural parameters related to pore dimensions revealed higher correlation coefficients with yield stress (r = -0.69 for average pore diameter and r = -0.62 for fraction of porous structures, p < 0.005) than parameters related to osteons (r = 0.60 for osteon density and average osteonal area, p < 0.005), whereas elastic modulus was predicted equally well by both types of parameters. Significant correlations were found between BMD and parameters related to porous structures (r = 0.85 for porosity, 0.80 for average pore area, and r = 0.79 for average pore diameter in polynomial regression, p < 0.005). Histologically assessed porosity correlated significantly with parameters describing porous structures and haversian canal dimensions. Our results indicate a relevance of osteon density and fraction of osteonal structures for the mechanical parameters of cortical bone. We consider the measurement of BMD by quantitative computed tomography to be helpful for the estimation of bone strength as well as for the prediction of intracortical porosity and parameters related to porous structures of cortical bone.

Aged↗

Influence of the structural properties of poly(vinylidene fluoride) membranes on the heterogeneous nucleation rate of protein crystals.

In this study, the influence of the morphological parameters of microporous poly(vinylidene fluoride) (PVDF) membranes on the heterogeneous nucleation rate of hen egg white lysozyme (HEWL) crystals has been investigated. Experiments have been carried out on membranes prepared by non-solvent-induced phase inversion method, using PVDF-co-hexafluoropropylene (Kynarflex 2800) and PVDF homopolymer (Kinar 460), and adding LiCl and poly(vinylpyrrolidone) (PVP) in order to modulate the pore structure. From a theoretical point of view, the free Gibbs energy balance for the formation of a critical nucleus has been adapted to nonporous surfaces, thus obtaining a mathematical correlation between the energy nucleation barrier, the membrane porosity, and the contact angle between protein solution and polymeric substrate. The energetic barrier to heterogeneous nucleation was found to increase at higher contact angles-according to the prediction of classical theory-and to decrease at higher porosity. For instance, the predicted deltaG(het)/deltaG(hom) ratio for PVDF-Kynarflex (PVP 2.5%) membrane with porosity of 0.11 was 0.30, 35% lower with respect to the value calculated by the Volmer equation for a dense polymeric matrix having the same contact angle (87.4 +/- 5.8 degrees). In addition, the effect of the membrane pore size, porosity, and thickness on the removal rate of solvent have been discussed. For example, the transmembrane flux through PVDF-Kynar (LiCl 5.0%) membrane was 12% inferior than the one measured under the same experimental conditions through PVDF-Kynarflex (LiCl 7.5%) membrane, the latter having similar pore size and thickness but higher porosity (0.44 vs 0.32). The possibility to achieve rapidly a high level of supersaturation is expected to increase the nucleation rate. In general, measurements performed during crystallization tests carried out at pH 4.5 in NaAc 0.05 M buffer with different precipitant (NaCl) concentrations agree with the predicted trends.

Crystallization↗