Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PHARMACOPEIA”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Two cases of therapeutic failure associated with levothyroxine brand interchange.

OBJECTIVE: To report the loss of therapeutic control in 2 hypothyroid patients and remind clinical pharmacists and other healthcare professionals to remain cognizant of possible product quality differences within or bioequivalency differences between levothyroxine products. CASE SUMMARIES: Two patients with stable hypothyroidism experienced symptoms of hypothyroidism with increased serum thyroid-stimulating hormone (TSH) concentrations after switching from 1 levothyroxine product to another. One tablet from 1 of the patient's levothyroxine prescriptions was assayed, and its levothyroxine content was 74.5% of the label claim, a value outside of the United States Pharmacopeia requirements of 90-110%. DISCUSSION: Two patients with hypothyroidism had remained euthyroid and stable while receiving 1 levothyroxine product, but became symptomatic with dramatically increased serum TSH concentrations while receiving what were thought to be comparable dosages of another levothyroxine product. Therapeutic control was reestablished in both patients after therapy with the original levothyroxine product was reinstated. CONCLUSIONS: Clinical pharmacists and other healthcare professionals should remain cognizant of possible product quality differences within or bioequivalency differences between levothyroxine products. These differences necessitate close monitoring of hypothyroid patients, counseling these patients about the clinical signs of sub- and supratherapeutic levothyroxine dosages, and prudence when switching patients with stable hypothyroidism to alternative levothyroxine products. If there are inconsistencies between levothyroxine products, resultant deleterious effects on the therapeutic stability of patients with hypothyroidism may undermine cost savings that might be incurred by such a change. If these patients are switched to alternative levothyroxine products, it is recommended that thyroid function tests be repeated after equilibration to the new product.

Adult↗

Effect on dissolution from halving methylphenidate extended-release tablets.

OBJECTIVE: To determine the effect on in vitro dissolution from cutting methylphenidate extended-release tablets in half. DESIGN: Ritalin-SR (Ciba Pharmaceutical Co.) and generic methylphenidate extended-release (MD Pharmaceutical Inc.) tablets were dissolved in water according to the method prescribed by the US Pharmacopeia under two conditions: whole and halved. Samples were collected at 15, 30, and 45 minutes and at 1, 2, 3, 3.5, 4, 5, 6, and 7 hours. Methylphenidate content was determined by HPLC. RESULTS: Halving the tablets caused a statistically significant increase in cumulative dissolution as early as 15 minutes. The difference in cumulative dissolution reached its maximum for both Ritalin-SR and generic methylphenidate extended-release tablets at 2 hours. At this time point, the percent dissolution of the whole versus halved tablets was 57% versus 74% (Ritalin-SR), respectively, and 49% versus 67% (generic), respectively. The dissolution profiles of halved and whole extended-release methylphenidate tablets were parallel from this point through the 7-hour collection period. At 7 hours, however, there was no difference in the cumulative dissolution of halved versus whole tablets. CONCLUSIONS: While statistical differences during in vitro dissolution do exist and pharmacokinetic ramifications have not yet been determined, the absolute differences in dissolution between halved and whole tablets are not great. Halving methylphenidate extended-release tablets may be a clinically acceptable means of achieving a small increment/decrement in dose without converting to a regular-release tablet.

Chromatography, High Pressure Liquid↗

Anticoagulant and antiprotease effects of a novel heparinlike compound from shrimp (Penaeus brasiliensis) and its neutralization by heparinase I.

Heparin is usually obtained from mammalian organs, such as beef lung, beef mucosa, porcine mucosa, and sheep intestinal mucosa. Because of the increased use of heparin in the production of low-molecular-weight heparin (LMWH), there is a growing shortage of the raw material needed to produce LMWHs. A previous report described the structural features of a novel LMWH from the shrimp (Penaeus brasiliensis). In order to compare anticoagulant and antiprotease effects of this heparin, global anticoagulant tests, such as the prothrombin time, activated partial thromboplastin time, thrombin time, and Heptest, were used. Amidolytic anti-Xa and anti-IIa activities were also measured. The relative susceptibility of this heparin to flavobacterial heparinase was also evaluated. The United States Pharmacopeia (USP) potency of shrimp heparin (SH) was found to be 28 U/mg. SH produced a concentration-dependent prolongation of all of the clotting tests and exhibited marked inhibition of FXa and FIIa. Heparinase treatment resulted in a marked decrease of the anticoagulant effects and neutralized the in vitro anti-IIa actions. However, the anti-Xa activities were only partially neutralized. Protamine sulfate was only partially effective in neutralizing the anticoagulant and antithrombin effects of SH. SH also produced marked prolongation of activated clotting time, which was neutralized by heparinase but not by protamine sulfate. These results suggest that SH is a strong anticoagulant with comparable properties to mammalian heparins and can be used in the development of clinically useful antithrombotic-anticoagulant drugs.

Animals↗

Disintegration/dissolution profiles of copies of Fosamax (alendronate).

OBJECTIVE: Poor quality has been reported for some generics and other copies of original products. We performed a pilot study to compare the disintegration/dissolution profiles of FOSAMAX (alendronate) 70 mg tablets with those of copies of FOSAMAX that were manufactured outside the United States. RESEARCH DESIGN AND METHODS: We used the standard United States Pharmacopeia (USP) disintegration method to evaluate FOSAMAX 70 mg tablets and 13 copies. At least 12 (n = 12) dosage units were tested for each product (except Fosmin, n = 10). The dissolution profiles of FOSAMAX and one representative copy were also compared. RESULTS: Nine copies (Osteomax, Defixal, Fosmin, Endronax, Osteomix, Genalmen, Fixopan, Osteoplus, and Fosval) disintegrated two- to ten-fold faster than FOSAMAX. Three other copies (Neobon, Regenesis, and Ostenan) disintegrated at least five-fold slower than FOSAMAX. Neobon is a softgel capsule, so special consideration was given to this different dosage form. One copy (Arendal) did not fall into either category but exhibited potentially large inter- and intra-lot variability. Dissolution of alendronate from Regenesis lagged behind that from FOSAMAX. CONCLUSION: Slower disintegration may reduce efficacy because bisphosphonates must be taken in the fasting state and contact with food or even certain beverages severely reduces bioavailability. Faster disintegration (or the use of gel-caps or other alterations to the drug formulation) could increase the risk of esophagitis, an adverse event associated with prolonged contact of the esophagus with bisphosphonates. These disintegration and dissolution results suggest that important differences may exist between FOSAMAX and its copies with regard to bioavailability, pharmacokinetics, and clinical efficacy and safety profiles. Additional testing is warranted to evaluate the pharmacokinetics and clinical safety of these copies.

Alendronate↗

Effect of rise in simulated inspiratory flow rate and carrier particle size on powder emptying from dry powder inhalers.

The purpose of this study was to evaluate the effect of carrier particle size and simulated inspiratory flow increase rate on emptying from dry powder inhalers (DPIs). Several flow rate ramps were created using a computer-generated voltage signal linked to an electronic proportioning valve with a fast response time. Different linear ramps were programmed to reach 30, 60, 90, and 120 L/minute over 1, 2, or 3 seconds. At the lower flow rates, 100-ms and 500-ms ramps were also investigated. Three DPIs, Spinhaler, Rotahaler, and Turbuhaler, were used to test the effect of flow rate ramp on powder emptying. To test the effect of carrier particle size, anhydrous lactose was sieved into 3 particle sizes, and 20 mg of each was introduced into #2 and #3 hard gelatin capsules for Spinhaler and Rotahaler, respectively. Emptying tests were also carried out using the on/off solenoid valve described in the United States Pharmacopeia (USP) (resulting in no ramp generation). Powder emptying increased from 9% to 46% for Rotahaler and 69% to 86% for Spinhaler from the shallowest (3 seconds to reach peak flow) to the 100-ms ramp for the 53- to 75 microm lactose size range at 30 L/minute. Similar trends were observed for larger particle size fractions at the same flow rate. However, at higher airflow rates (60, 90, and 120 L/minute), there was no significant increase in percentage of emptying within the ramps for a particular particle size range. Trends observed were similar for placebo-filled Turbuhaler and commercially available Rotacaps used with Rotahaler, with the steepest ramp demonstrating more complete emptying. Percentage of powder emptying determined by the USP solenoid valve overestimated the emitted dose compared with the ramp method at 30 L/minute for all 3 devices. Results indicate that there is a significant difference in powder emptying at 30 L/minute from the shallowest to the steepest ramp within a particular size range. Within a particular particle size range, the USP method produced more complete emptying than even the steepest ramp, especially at the lower flow rates. Thus, when the USP device is used to estimate DPI emptying at lower flow rates, the results are likely to overestimate DPI performance significantly.

Analysis of Variance↗

Evaluation of USP apparatus 3 for dissolution testing of immediate-release products.

We sought to evaluate whether U.S. Pharmacopeia (USP) apparatus 3 can be used as an alternative to USP apparatus 2 for dissolution testing of immediate-release (IR) dosage forms. Highly soluble drugs, metoprolol and ranitidine, and poorly soluble drugs, acyclovir and furosemide, were chosen as model drugs. The dissolution profiles of both innovator and generic IR products were determined using USP apparatus 2 at 50 rpm and apparatus 3 at 5, 15, and 25 dips per minute (dpm). The dissolution profiles from USP apparatus 3 were compared to those from USP apparatus 2 using the f(2) similarity test. The dissolution profile from USP apparatus 3 generally depends on the agitation rate, with a faster agitation rate producing a faster dissolution rate. It was found that USP apparatus 3 at the extreme low end of the possible agitation range, such as 5 dpm, gave hydrodynamic conditions equivalent to USP apparatus 2 at 50 rpm. With appropriate agitation rate, USP apparatus 3 can produce similar dissolution profiles to USP apparatus 2 or distinguish dissolution characteristics for the IR products of metoprolol, ranitidine, and acyclovir. Incomplete dissolution was observed for the furosemide tablets using USP apparatus 3. Although it is primarily designed for the release testing of extended-release products, USP apparatus 3 may be used for the dissolution testing of IR products of highly soluble drugs, such as metoprolol and ranitidine, and some IR products of poorly soluble drugs, such as acyclovir. USP apparatus 3 offers the advantages of avoiding cone formation and mimicking the changes in physiochemical conditions and mechanical forces experienced by products in the gastrointestinal tract.

Acyclovir↗

Pramlintide injection drug product robustness studies.

The article examines the effects of temperature excursions and actual dose withdrawal on the quality of pramlintide injection, a multidose liquid parenteral formulation. Studies were designed to demonstrate product robustness under conditions that may occur during patient use. Pramlintide %Purity was determined by two high-performance liquid chromatography (HPLC) methods, a reversed-phase (RP-HPLC) and a strong-cation exchange (SCX-HPLC) method. A second RP-HPLC method was used to determine pramlintide potency and the concentration of the m-cresol preservative. Antimicrobial preservative effectiveness testing was per USP and European Pharmacopeia (Ph. Eur.). Short-term stability studies were undertaken to probe the effects of the following conditions: 5 degrees C to 40 degrees C and 5 degrees C to -20 degrees C temperature cycling over 10 days; once daily or four-times daily dose withdrawal over 12 or 42 days; and combined 30 degrees C storage and four-times daily dose withdrawal over 42 days. In all cases, pramlintide %Purity and potency values remained essentially unchanged or unchanged relative to controls. Similarly, product appearance, and m-cresol concentration and preservative effectiveness were not significantly affected by the stress conditions used in the 5 studies. Pramlintide injection drug product is extremely robust to challenging stress conditions that may occur during patient use of this multidose product for chronic administration.

Amyloid↗

Evaluation of an acetic acid ester of monoglyceride as a suppository base with unique properties.

The objective of this investigation was to evaluate an acetic acid ester of monoglycerides made from edible, fully hydrogenated palm oil (AC-70) as a suppository base and compare it with a commercially available semisynthetic base (Suppocire AI). Benzocaine and miconazole were used as model drugs. Suppositories were prepared by the fusion method. The drug loads in the suppositories were kept at 2% to 5% (wt/wt). In vitro release of drug from the suppositories into Sorensen's phosphate buffer (pH 7.4) was studied using a US Pharmacopeia dissolution apparatus 1 and a spectrophotometer. The melting behavior of the bases and the physical state of the drug in the suppositories were studied using a differential scanning calorimeter (DSC). Powder x-ray diffractometry was used to study any possible polymorphic changes in the AC-70 base during formulation and storage. In vitro release studies revealed that the release of benzocaine from the AC-70 suppository was substantially slower than that of the commercial AI base. At a 2.5% (wt/wt) benzocaine load, the release of drug from the AC-70 suppositories was found to be linear. This slow and linear release was attributed to the physical property of the base, which forms liquid crystalline phases in the aqueous dissolution medium. The lyotropic liquid crystalline phase has the ability to incorporate drug into its structure and can control the release kinetics of the drug from such a system. The apparent pH of the release medium (water) was decreased by 1 to 1.5 pH units when the AC-70 base was used. The DSC studies revealed that the melting range of the AC-70 base is 36 degrees C to 38 degrees C, which is ideal for suppository formulations. The results of these studies support the possibility of using this new base for slow-release suppository formulations. This base may be of particular interest for a drug that requires an acidic environment to maintain its activity.

Acetates↗

Controlled release formulation of tramadol hydrochloride using hydrophilic and hydrophobic matrix system.

The effect of concentration of hydrophilic (hydroxypropyl methylcellulose [HPMC]) and hydrophobic polymers (hydrogenated castor oil [HCO], ethylcellulose) on the release rate of tramadol was studied. Hydrophilic matrix tablets were prepared by wet granulation technique, while hydrophobic (wax) matrix tablets were prepared by melt granulation technique and in vitro dissolution studies were performed using United States Pharmacopeia (USP) apparatus type II. Hydrophobic matrix tablets resulted in sustained in vitro drug release (>20 hours) as compared with hydrophilic matrix tablets (<14 hours). The presence of ethylcellulose in either of the matrix systems prolonged the release rate of the drug. Tablets prepared by combination of hydrophilic and hydrophobic polymers failed to prolong the drug release beyond 12 hours. The effect of ethylcellulose coating (Surelease) and the presence of lactose and HPMC in the coating composition on the drug release was also investigated. Hydrophobic matrix tablets prepared using HCO were found to be best suited for modulating the delivery of the highly water-soluble drug, tramadol hydrochloride.

Chemistry, Pharmaceutical↗

Comparison of the dissolution of metaxalone tablets (Skelaxin) using USP Apparatus 2 and 3.

The purpose of this study was to evaluate the effect of pH on the dissolution behavior of metaxalone in the marketed product Skelaxin tablets. The dissolution was evaluated using United States Pharmacopeia (USP) dissolution Apparatus 2 and 3 at pHs ranging from 1.5 to 7.4. Results from these studies show that the dissolution of this product is pH dependent. At low pH (simulated gastric fluid, pH 1.5), the dissolution of metaxalone from Skelaxin tablets was less than 10% over 75 minutes; whereas, dissolution at pH 4.5 showed greater than 90% release in the same time period. These results were consistent for both Apparatus 2 and 3. This suggests that Skelaxin Tablets should be considered a delayed release dosage form.

Delayed-Action Preparations↗

Effect of degree of esterification of pectin and calcium amount on drug release from pectin-based matrix tablets.

The aim of this work was to assess the effect of 2 formulation variables, the pectin type (with different degrees of esterification [DEs]) and the amount of calcium, on drug release from pectin-based matrix tablets. Pectin matrix tablets were prepared by blending indomethacin (a model drug), pectin powder, and various amounts of calcium acetate and then tableting by automatic hydraulic press machine. Differential scanning calorimetry, powder x-ray diffraction, and Fourier transformed-infrared spectroscopy studies of the compressed tablets revealed no drug-polymer interaction and the existence of drug with low crystallinity. The in-vitro release studies in phosphate buffer (United States Pharmacopeia) and tris buffer indicated that the lower the DE, the greater the time for 50% of drug release (T50). This finding is probably because of the increased binding capacity of pectin to calcium. However, when the calcium was excluded, the pectins with different DEs showed similar release pattern with insignificant difference of T50. When the amount of calcium acetate was increased from 0 to 12 mg/tablet, the drug release was significantly slower. However, a large amount of added calcium (ie, 24 mg/tablet) produced greater drug release because of the partial disintegration of tablets. The results were more pronounced in phosphate buffer, where the phosphate ions induced the precipitation of calcium phosphate. In conclusion, both pectin type and added calcium affect the drug release from the pectin-based matrix tablets.

Calcium↗

Computational fluid dynamics modeling of the paddle dissolution apparatus: agitation rate, mixing patterns, and fluid velocities.

The purpose of this research was to further investigate the hydrodynamics of the United States Pharmacopeia (USP) paddle dissolution apparatus using a previously generated computational fluid dynamics (CFD) model. The influence of paddle rotational speed on the hydrodynamics in the dissolution vessel was simulated. The maximum velocity magnitude for axial and tangential velocities at different locations in the vessel was found to increase linearly with the paddle rotational speed. Path-lines of fluid mixing, which were examined from a central region at the base of the vessel, did not reveal a region of poor mixing between the upper cylindrical and lower hemispherical volumes, as previously speculated. Considerable differences in the resulting flow patterns were observed for paddle rotational speeds between 25 and 150 rpm. The approximate time required to achieve complete mixing varied between 2 to 5 seconds at 150 rpm and 40 to 60 seconds at 25 rpm, although complete mixing was achievable for each speed examined. An analysis of CFD-generated velocities above the top surface of a cylindrical compact positioned at the base of the vessel, below the center of the rotating paddle, revealed that the fluid in this region was undergoing solid body rotation. An examination of the velocity boundary layers adjacent to the curved surface of the compact revealed large peaks in the shear rates for a region within ~3 mm from the base of the compact, consistent with a "grooving" effect, which had been previously seen on the surface of compacts following dissolution, associated with a higher dissolution rate in this region.

Models, Chemical↗

The influence of the copolymer composition on the diltiazem hydrochloride release from a series of pH-sensitive poly[(N-isopropylacrylamide)-co-(methacrylic acid)] hydrogels.

A series of poly[(N-isopropylacrylamide)-co-(methacrylic acid)] (P[(N-iPAAm)-co-(MAA)]) hydrogels was investigated to determine the composition that exhibits a better pH-modulated release of diltiazem hydrochloride (DIL.HCl). For this purpose hydrogel slabs were loaded with DIL.HCl by the immersion method, and its release under acidic medium (0.1N HCl, pH 1.2) and in phosphate buffer pH 7.2, using United States Pharmacopeia (USP) 24 Apparatus 1, was investigated. According to the results from the slabs, copolymers with 85% mol N-iPAAm content were selected to prepare tablets with different particle size. The effect of pH and particle size changes on DIL.HCl release from these last hydrogel tablets was investigated by a stepwise pH variation of the dissolution medium. The amount of DIL.HCl released from high N-iPAAm content copolymer slabs under acidic pH medium was not only very low but it was also released at a slow rate. In the 85% N-iPAAm tablets, significant differences between and within release profiles were found as a function of particle size and pH, respectively. A relationship between particle size and release rate has been found. The lower DIL.HCl release at acidic pH from enriched N-iPAAm copolymers is interpreted by a cooperative thermal- and pH-collapse. Although for the whole range of copolymer composition a dependence of the equilibrium of swelling on the pH was found, DIL.HCl release experiments indicated that hydrogels with 85% mol N-iPAAm are the more adequate to be used for modulated drug delivery systems. Additionally, the particle size of the tablet can be used to tailor the release rate.

Acrylamides↗

Formulation and in vitro, in vivo evaluation of extended- release matrix tablet of zidovudine: influence of combination of hydrophilic and hydrophobic matrix formers.

The aim of the present study was to prepare and characterize extended-release matrix tablets of zidovudine using hydrophilic Eudragit RLPO and RSPO alone or their combination with hydrophobic ethyl cellulose. Release kinetics was evaluated by using United States Pharmacopeia (USP)-22 type I dissolution apparatus. Scanning electron microscopy was used to visualize the effect of dissolution medium on matrix tablet surface. Furthermore, the in vitro and in vivo newly formulated sustained-release zidovudine tablets were compared with conventional marketed tablet (Zidovir, Cipla Ltd, Mumbai, India). The in-vitro drug release study revealed that either Eudragit preparation was able to sustain the drug release only for 6 hours (94.3% +/- 4.5% release). Combining Eudragit with ethyl cellulose sustained the drug release for 12 hours (88.1% +/- 4.1% release). Fitting the in vitro drug release data to Korsmeyer equation indicated that diffusion along with erosion could be the mechanism of drug release. In vivo investigation in rabbits showed sustained-release pharmacokinetic profile of zidovudine from the matrix tablets formulated using combination of Eudragits and ethylcellulose. In conclusion, the results suggest that the developed sustained-release tablets of zidovudine could perform therapeutically better than conventional dosage forms, leading to improve efficacy and better patient compliance.

Animals↗

Intragastric floating drug delivery system of cefuroxime axetil: in vitro evaluation.

This investigation describes the development of an intragastric drug-delivery system for cefuroxime axetil. The 3(2) full factorial design was employed to evaluate contribution of hydroxypropyl methyl cellulose (HPMC) K4M/HPMC K100 LV ratio (polymer blend) and sodium lauryl sulfate (SLS) on drug release from HPMC matrices. Tablets were prepared using direct compression technique. Formulations were evaluated for in vitro buoyancy and drug release study using United States Pharmacopeia (USP) 24 paddle-type dissolution apparatus using 0.1N HCl as a dissolution medium. Multiple regression analysis was performed for factorial design batches to evaluate the response. All formulations had floating lag times below 2 minutes and constantly floated on dissolution medium for more than 8 hours. It was found that polymer blend and SLS significantly affect the time required for 50% of drug release, percentage drug release at 12 hours, release rate constant, and diffusion exponent (P < .05). Also linear relationships were obtained between the amount of HPMC K100 LV and diffusion exponent as well as release rate constant. Kinetic treatment to dissolution profiles revealed drug release ranges from anomalous transport to case 1 transport, which was mainly dependent on both the independent variables.

Anti-Bacterial Agents↗

Fast-disintegrating sublingual tablets: effect of epinephrine load on tablet characteristics.

The aim of this study was to evaluate the effect of increasing epinephrine load on the characteristics of fast-disintegrating sublingual tablets for the potential emergency treatment of anaphylaxis. Four tablet formulations, A, B, C, and D, containing 0%, 6%, 12%, and 24% of epinephrine bitartrate, respectively, and microcrystalline cellulose:low-substituted hydroxypropyl cellulose (9:1), were prepared by direct compression, at a range of compression forces. Tablet weight variation, content uniformity, hardness, disintegration time, wetting time, and friability were measured for each formulation at each compression force. All 4 tablet formulations at each compression force were within the United States Pharmacopeia (USP) limits for weight variation and content uniformity. A linear increase in compression force resulted in an exponential increase in hardness for all formulations, a linear increase in disintegration and wetting times of A, and an exponential increase in disintegration and wetting times of B, C, and D. At a mean +/- SD hardness of > or = 2.3 +/- 0.2 kg, all tablet formulations passed the USP friability test. At a mean +/- SD hardness of < or = 3.1 +/- 0.2 kg, all tablet formulations resulted in disintegration and wetting times of <10 seconds and <30 seconds, respectively. Tablets with drug loads from 0% to 24% epinephrine can be formulated with hardness, disintegration times, and wetting times suitable for sublingual administration.

Administration, Oral↗

Cross-linked guar gum microspheres: a viable approach for improved delivery of anticancer drugs for the treatment of colorectal cancer.

In the present work, guar gum microspheres containing methotrexate (MTX) were prepared and characterized for local release of drug in the colon, which is a prerequisite for the effective treatment of colorectal cancer. Guar gum microspheres were prepared by the emulsification method using glutaraldehyde as a cross-linking agent. Surface morphological characteristics were investigated using scanning electron microscopy. Particle size, shape, and surface morphology were significantly affected by guar gum concentration, glutaraldehyde concentration, emulsifier concentration (Span 80), stirring rate, stirring time, and operating temperature. MTX-loaded microspheres demonstrated high entrapment efficiency (75.7%). The in vitro drug release was investigated using a US Pharmacopeia paddle type (type II) dissolution rate test apparatus in different media (phosphate-buffered saline [PBS], gastrointestinal fluid of different pH, and rat cecal content release medium), which was found to be affected by a change to the guar gum concentration and glutaraldehyde concentration. The drug release in PBS (pH 7.4) and simulated gastric fluids followed a similar pattern and had a similar release rate, while a significant increase in percent cumulative drug release (91.0%) was observed in the medium containing rat cecal content. In in vivo studies, guar gum microspheres delivered most of their drug load (79.0%) to the colon, whereas plain drug suspensions could deliver only 23% of their total dose to the target site. Guar gum microspheres showed adequate potential in achieving local release of drug in in vitro release studies, and this finding was further endorsed with in vivo studies.

Antineoplastic Agents↗

Estimation of individual sennosides in plant materials and marketed formulations by an HPTLC method.

Senna is a well-known drug, used in the Ayurvedic and Allopathic systems of medicine, and is a treatment for constipation. The purgative action of senna and its formulations is due to the presence of sennosides A and B. An HPTLC method has been developed for the determination of individual sennosides (A, B, C, D) without any derivatization in marketed formulations (three tablet formulations, two granule formulations and one liquid formulation) and plant materials (senna leaf and pod). The methanolic solution of a sample was applied on a pre-coated silica gel G60 F254 TLC plate (E. Merck.) and was developed using n-propanol : ethyl acetate : water : glacial acetic acid (3 : 3 : 2 : 0.1 v/v) as the mobile phase. The relative band speeds (Rf values) obtained were 0.35, 0.25, 0.61, 0.46 for sennosides A, B, C and D, respectively. The densitometric response was monitored at 366nm. Calibration curves were found to be linear in the concentration ranges 193-1356, 402-2817, 71-497 and 132-927 ng per spot for sennosides A, B, C, and D, respectively. The correlation coefficients were found to be 0.9978, 0.9987, 0.9939 and 0.9983 respectively for sennosides A, B, C and D. The result obtained with the HPTLC method for total sennoside content was compared with the results using the pharmacopoeial methods (spectrophotometric (British Pharmacopoeia) and spectrofluorimetric (United States Pharmacopeia) using the 'F' test). The results revealed no significant difference in the three different methods for estimation of total sennoside. The proposed HPTLC method was found to be simple, specific, precise, accurate and rapid. It can be used for routine quality control of sennosides or senna-containing formulations for individual sennosides.

Anthraquinones↗