Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flocculation Tests”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Experimental uveitis induced by prostatic antigens.

Experimental uveitis was induced in male rats following their repeated systemic and intravitreous immunization with prostatic antigen and CFA. The ensuing uveitis was proved histologically. Heteroimmunized rabbits and female animals showed less response and the level of antibodies detected was lower. Anti-prostatic antibodies were determined by the TRC flocculation and PCA techniques. Ouchterlony's method gave positive results not only for prostatic but also for other ocular antigens when tested against the same test sera.

Animals↗

Olive oil mill wastewater purification by combination of coagulation- flocculation and biological treatments.

In order to define an efficient pre-treatment of Olive Oil Mill Wastewater (OOMW) to overcome major obstacles to biological treatment, various organic and mineral coagulants have been tested. In particular, the application of quicklime until a pH around 12 - 12.4 was reached, allowed the reduction of almost 37% of the initial COD, and approximately 88% and 71% of the colour and phenolic content of the waste. Hence, further biological treatments with an adapted aerobic consortium (AC) and a white rot fungus (WRF) strain were improved. The WRF Coriolopsis polyzona was more efficient than AC to reduce colour and polyphenols when the waste was prior diluted or pre-treated; however, it was less effective in COD removal. The combined treatment: lime - AC of OOMW having initial COD of 102 g l(-1) led to the elimination of about 77, 91 and 63%, of the COD, phenols and colour, respectively. Interestingly, the opposite combination AC - lime permitted better COD, phenols and colour reduction to respectively, 21, 11 and 11% of the initial values. This latter condition is technically recommended since only one step separation was needed and no pH correction was necessary before undergoing aerobic treatment. Moreover, the process would produce a sludge potentially rich in organic matter, and consequently, useful as an agricultural amendment or/and as an additive in animal nutrition.

Basidiomycota↗

Novel cake characteristics of waste-activated sludge.

Breaking down the time limit constraints for conventional compression-permeation (C-P) cell test, this work has, for the first time, experimentally evaluated the cake characteristics of viable waste-activated sludge subject to polyelectrolyte flocculation and to freeze/thaw treatment under a pressure range of 25-200 kPa. There exists a threshold pressure exceeding which the cake structure would significantly deteriorate. Also, the present biological sludge is a "super-compactible" sludge, whose compactibility is greater than most data ever reported in open literature. The information presented herein has implications to filter design/operation and can be used as a reference data set for examining the existing filtration theories.

Bacteria↗

Interactions between cationic liposomes and bacteria: the physical-chemistry of the bactericidal action.

The bactericidal effect of dioctadecyldimethylammonium bromide (DODAB), a liposome forming synthetic amphiphile, is further evaluated for Escherichia coli, Salmonella typhimurium, Pseudomonas aeruginosa, and Staphylococcus aureus in order to establish susceptibilities of different bacteria species towards DODAB at a fixed viable bacteria concentration (2.5 x 10(7) viable bacteria/mL). For the four species, susceptibility towards DODAB increases from E. coli to S. aureus in the order above. Typically, cell viability decreases to 5% over 1 h of interaction time at DODAB concentrations equal to 50 and 5 microm for E. coli and S. aureus, respectively. At charge neutralization of the bacterial cell, bacteria flocculation by DODAB vesicles is shown to be a diffusion-controlled process. Bacteria flocculation does not yield underestimated counts of colony forming units possibly because dilution procedures done before plating cause deflocculation. The effect of vesicle size on cell viability demonstrates that large vesicles, due to their higher affinity constant for the bacteria (45.20 m(-)) relative to the small vesicles (0.14 m(-)), kill E. coli at smaller DODAB concentrations. For E. coli and S. aureus, simultaneous determination of cell viability and electrophoretic mobility as a function of DODAB concentration yields a very good correlation between cell surface charge and cell viability. Negatively charged cells are 100% viable whereas positively charged cells do not survive. The results show a clear correlation between simple adsorption of entire vesicles generating a positive charge on the cell surfaces and cell death.

Anti-Bacterial Agents↗

Assessment of an enterovirus sewage surveillance system by comparison of clinical isolates with sewage isolates from milwaukee, wisconsin, collected august 1994 to december 2002.

The quantity and serotypes of enteroviruses (EVs) in the influent of a local sewage treatment plant were compared to local clinical EV cases to determine if testing of sewage is adequate for an EV surveillance system. The study was carried out from August 1994 to December 2002. Monthly influent specimens were processed by organic flocculation, and dilutions of concentrate were inoculated onto a number of different cell types for virus isolation. EVs were detected in 88 of 100 monthly influent samples. Sewage EV titers were calculated by using software provided by the U.S. Environmental Protection Agency for most-probable-number determination. All 1,068 sewage EV isolates were further grouped (echovirus, coxsackievirus B, coxsackievirus A, or poliovirus) by cell culture host range analysis (growth pattern of isolates on passage to seven cell lines), and 39.0% of the 1,022 EV isolates categorized as non-poliovirus EVs were specifically serotyped. For clinical cases, primary virus isolation tests were performed on specimens submitted by local hospitals and EV isolates submitted by hospitals were serotyped. Clinical EVs were documented for 81 of the 100 months studied. In all, 694 EV isolates from clinical cases were serotyped. Annually, between 4 and 11 different serotypes of non-poliovirus EVs were identified in sewage and from 9 to 19 different non-poliovirus EV serotypes were identified from clinical specimens. Usually, the most commonly detected sewage EV serotypes were similar to the most commonly detected clinical serotypes; e.g., for 1997, echovirus 6 accounted for 53.1% of the typed sewage isolates and 39.4% of the clinical infections, while in 1998, echovirus 30 accounted for 50.0 and 46.1%, respectively. In 1999, 60.3% of the EVs from clinical cases and 79.7% of the sewage isolates were echovirus 11; in 2000, 33.3% of the EVs from clinical cases and 40.7% of the sewage isolates were coxsackievirus B5; and in 2001, 44.1% of the EVs from clinical cases and 36.2% of the sewage isolates were echovirus 13. Annual peaks of both sewage EV titers and clinical cases occurred in late summer or early fall. In some years, early spring sewage EVs portended some of the EVs that would predominate clinically during the following summer.

Animals↗

Polyelectrolyte conditioning for iron-hydroxide-containing sludge produced from electroflocculation of fermentation wastewater.

The purpose of this study is to investigate the application of chemical conditioning method for the post-electroflocculation wastewater sludge treatment with polyelectrolytes of varying ionic characters, namely anionic, cationic and nonionic flocculating agents. Electroflocculation, a combination of the processes of electroflotation and electroprecipitation, was found effective to remove the organic and color components in monosodium glutamate fermentation wastewater. The settleability and dewaterability of the separated sludge, containing 15-20% of iron hydroxides, increased 35% and 60% due to polymer conditioning through a jar-test apparatus. The influence of shear conditions and polymer dose on the floc size, zeta potential, filterability and dewatering performance, and shear resistance of sludges was investigated. Experimental results showed that the anionic polymer acts as a better flocculating agent than both cationic and nonionic polymers, and the optimal polymer doses fall between 4.0 and 10.0 mg/g Fe sludge under corresponding shear rates of 200 300 rpm. This study also indicated that both charge neutralization and polymer bridging mechanisms operate in the sludge conditioning process.

Electrochemistry↗

Effect of floc structure on the rate of shear coagulation.

We derived a mathematical expression for the temporal evolution of the number of particles due to shear coagulation, covering the later stage by expanding the initial stage approximation to take into account the formation of floc structure. In the derivation, it is assumed that flocculation proceeds through binary collisions between identical fractal flocs. The capture efficiency between flocs is calculated on the basis of trajectory analysis, which is determined by viscous hydrodynamic interaction between flocs and van der Waals attractive forces between two primary particles located at colliding points of flocs. The validity of the derived equation was tested by a coagulation experiment using polystyrene sulfate latex particles under conditions of rapid coagulation. The experiment was carried out in a laminar Couette flow generated in the gap between two concentric cylinders. Careful and direct observation of flocculation under microscopy provided the data on the fractal dimension as well as the temporal evolution of number concentration of flocs. The measured rate of coagulation gradually increases in accordance with the formation of the fractal structure of flocs. This behavior agreed very well with the prediction based on the derived equation.

Journal Article↗

Reducing diarrhoea in Guatemalan children: randomized controlled trial of flocculant-disinfectant for drinking-water.

OBJECTIVE: To examine the effect of a new point-of-use treatment for drinking-water, a commercially developed flocculant-disinfectant, on the prevalence of diarrhoea in children. METHODS: We conducted a randomized controlled trial among 514 rural Guatemalan households, divided into 42 neighbourhood clusters, for 13 weeks, from 4 November 2002 through 31 January 2003. Clusters assigned to water treatment with the flocculant-disinfectant were compared with those using their usual water-handling practices. The longitudinal prevalence of diarrhoea was calculated as the proportion of total days with diarrhoea divided by the total number of days of observation. The prevalence of diarrhoea was compared using the Wilcoxon rank-sum test. FINDINGS: The 1702 people in households receiving the disinfectant had a prevalence of diarrhoea that was 40% lower than that among the 1699 people using standard water-handling practices (0.9% versus 1.5%; P = 0.001). In households using the flocculant-disinfectant, children < 1 year of age had a 39% lower prevalence of diarrhoea than those in households using their standard practices (3.7% versus 6.0%; P = 0.005). CONCLUSION: In settings where families rarely treat drinking-water, we introduced a novel flocculant-disinfectant that reduced the longitudinal prevalence of diarrhoea, especially among children aged < 1 year, among whom diarrhoea has been strongly associated with mortality. Successful introduction and use of this product could contribute to preventing diarrhoeal disease globally.

Adolescent↗

Recovery of viruses from vegetable surfaces.

The efficiency of a system developed for the recovery of viruses contaminating large quantities of vegetables was investigated in the laboratory and tested in the field. Viruses seeded onto a number of leafy vegetables in the laboratory were eluted with a phosphate-buffered saline solution (pH 9.0). The eluate was clarified by glass wool filtration, and any viruses present were concentrated by adsorption to a Filterite pleated cartridge filter, eluted with 3% beef extract (pH 9.0), and further concentrated by organic flocculation. At least 24 liters of vegetable eluate could be concentrated to 70 to 80 ml, equivalent to a greater than 99.5% reduction in volume. With this system, poliovirus was recovered with a mean efficiency of 58% for all vegetables tested. Adenovirus was recovered from lettuce with a slightly lower mean efficiency (55%). Poliovirus was recovered from large quantities of cabbage for up to 5 days in the field after spray irrigation of relatively low levels of virus, even when heavy rain fell before sampling.

Adenoviridae↗

Modification of the Rappaport rapid test in large-scale testing for syphilis. Evaluation of the rapid plate and rapid card tests.

The Rappaport rapid (RR) plate and card tests were developed as modifications of the RR tube test to permit rapid and inexpensive screening of large numbers of subjects for the diagnosis of syphilis. More than 2,000 sera were examined in parallel by the Venereal Disease Research Laboratory (VDRL) slide test, the rapid plasma reagin (RPR) card test and the RR plate and card tests. There was complete agreement between the RR plate and card tests and the VDRL slide and RPR card tests in 96.6% of sera. In a selected group of 1,530 sera examined, in addition, by the fluorescent treponemal antibody absorption (FTA-ABS) test, there was agreement between the RR plate and card tests and the FTA-ABS test in 74.3% of sera and between the VDRL and RPR tests and the FTA-ABS test in 73.7% of sera. The RR plate test was found to be sufficiently sensitive and specific for the diagnosis of syphilis, although the VDRL slide test is perhaps more sensitive in primary and late latent syphilis. Since the antigen used in the RR tests is colored and stable and the sera do not require inactivation before the test, the tests are easier to perform than the VDRL slide test: the RR plate and card tests could therefore replace the VDRL test as a screening test, with hardly any loss of accuracy.

Flocculation↗

Characterization of tributyltin in shipyard waters and removal through laboratory and full-scale treatment.

Characterization and treatment studies were conducted in an effort to evaluate treatment options capable of removing tributyltin (TBT) in shipyard waters from above 1,000,000 ng/L to effluent concentrations below 50 ng/L. Laboratory studies and operation of a full-scale treatment plant were used to examine treatment options for TBT removal and included physicochemical treatment processes of coagulation-clarification, filtration, and granular activated carbon (GAC) adsorption. Significant variability was observed in TBT-containing shipyard waters (generated from different ships) in terms of their particulate solids, conductivity, and TBT and dissolved organic carbon concentrations. Laboratory tests with aluminum sulfate and ferric sulfate showed that on average 90% of TBT in shipyard waters could be removed by coagulation-flocculation-clarification under optimum conditions. No statistically significant difference was found in TBT removal capabilities between the two metal salts when compared at equivalent metal doses and coagulation pH. Much lower removals were observed for the coagulation-flocculation-clarification portion of the full-scale plant while the complete full-scale treatment plant averaged 99.8% TBT removal over a period of 3 years. While relatively high % removals were achieved, the total treatment process did not consistently remove TBT to levels that would meet the regulatory requirements proposed (50 ng/L) at the time the study was conducted. Based on the results from limited efforts to characterize the dissolved and particulate TBT fractions in the full-scale treatment plant effluent, particulate TBT was observed to be the dominant component of the effluent TBT from the full-scale plant and may be associated with polymer carry through.

Adsorption↗

Dissolved air flotation clarification of activated sludge and wastewaters from chemical industry.

Wastewaters from separate chemical factories are treated together in an extended aeration activated sludge plant. The factories produce chemicals for paper industry (e.g. starch), latexes and animal feed. The components of the wastewaters include styrene, tertiary butanol and vinyl acetate. Activated sludge is clarified by sedimentation. During winter time, when the water temperature was 3-12 degrees C, the clarification deteriorated causing carry over of suspended solids containing COD. Enhancement of suspended solids and COD removals was studied in a dissolved air flotation jar test unit. Flotation trials were conducted for activated sludge, sedimentation treated final effluent (tertiary treatment) and separate wastewater fractions. The need for chemicals, flocculation and amount of recycle water were judged according to the achieved removals. Dissolved air flotation was found well suited for the clarification of activated sludge, but not technically and economically feasible for the clarification of the wastewater streams before the activated sludge treatment.

Air↗

Modeling precipitation and sorption of elements during mixing of river water and porewater in the Coeur d'Alene River basin.

Reddish brown flocs form along the edge of the Coeur d'Alene River when porewater drains into river water during the annual lowering of water level in the basin. The precipitates are efficient scavengers of dissolved elements and have characteristics that may make metals associated with them bioavailable. This work characterizes the geochemistry of the porewater and models the formation and composition of the flocs. Porewater is slightly acidic, has suboxic to anoxic characteristics, tends to have higher alkalinity, and contains elevated concentrations of many constituents relative to river water. Laboratory mixing experiments involving porewater and river water were done to produce the precipitates. Thermodynamic predictions using PHREEQC indicate that predicted amounts of ferrihydrite and gibbsite agree with removal of Fe and Al. Predictions of element removal by adsorption onto ferrihydrite are consistent with observed removal using a combination of surface complexation constants for the generalized two-layer model (As and Se), alternative surface constants derived from experiments at high sorbate-to-sorbent ratios (Cd, Co, Cu, Ni, Pb, and Zn), and adjusted surface constants to fit experimental data (Cr, Mo, and Sb). This new set of surface complexation constants needs further testing in other contaminated systems.

Chemical Precipitation↗