At least 811 records · Page 45Linked to original sources

Transforming growth factor-beta1 incorporation in a calcium phosphate bone cement: material properties and release characteristics.

The bone regenerative properties of calcium phosphate cements (CPCs) may be improved by the addition of growth factors, such as recombinant human transforming growth factor-beta1 (rhTGF-beta1). Previously, we showed that rhTGF-beta1 in CPC stimulated the differentiation of preosteoblastic cells from adult rat long bones. The intermixing of rhTGF-beta1 in CPC, which was subsequently applied to rat calvarial defects, enhanced bone growth around the cement and increased the degradation of the cement. However, it is unknown whether the addition of rhTGF-beta1 changes the material properties of CPC and what the characteristics of the release of rhTGF-beta1 from CPC are. Therefore, we determined in this study the release of rhTGF-beta1, in vitro, from the cement pellets as implanted in the rat calvariae. The possible intervening effects of rhTGF-beta1 intermixing on the clinical compliance of CPC were studied through an assessment of its compressive strength and setting time, as well as its crystallinity, calcium-to-phosphorus ratio, porosity, and microscopic structure. We prepared CPC by mixing calcium phosphate powder (58% alpha-tricalcium phosphate, 25% anhydrous dicalcium phosphate, 8.5% calcium carbonate, and 8.5% hydroxyapatite) with a liquid (3 g/mL). The liquid for standard CPC consisted of water with 4% disodium hydrogen phosphate, whereas the liquid for modified CPC was mixed with an equal amount of 4 mM hydrochloride with 0.2% bovine serum albumin. The hydrochloride liquid contained rhTGF-beta1 in different concentrations for the release experiments. Most of the rhTGF-beta1 incorporated in the cement pellets was released within the first 48 h. For all concentrations of intermixed rhTGF-beta1 (100 ng to 2.5 mg/g of CPC), approximately 0.5% was released in the first 4 h, increasing to 1.0% after 48 h. Further release was only about 0.1% from 2 days to 8 weeks. CPC modification slightly increased the initial setting time at 20 degrees C from 2.6 to 5 min but had no effect on the final setting time of CPC at 20 degrees C or the initial and final setting times at 37 degrees C. The compressive strength was increased from 18 MPa in the standard CPC to 28 MPa in the modified CPC only 4 h after mixing. The compressive strength diminished in the modified CPC between 24 h and 8 weeks from 55 to 25 MPa. No other significant change was found with the CPC modification for rhTGF-beta1. X-ray diffraction revealed that standard and modified CPCs changed similarly from the original components, alpha-tricalcium phosphate and anhydrous dicalcium phosphate, into an apatite cement. The calcium-to-phosphorus ratio, as determined with an electron microprobe, did not differ for standard CPC and modified CPC. Standard and modified CPCs became dense and homogeneous structures after 24 h, but the modified CPC contained more crystal plaques than the standard CPC, as observed with scanning electron microscopy (SEM). SEM and back- scattered electron images revealed that after 8 weeks the cements showed equally and uniformly dense structures with microscopic pores (<1 microm). Both CPCs showed fewer crystal plaques at 8 weeks than at 24 h. This study shows that CPC is not severely changed by its modification for rhTGF-beta1. The prolonged setting time of modified cement may affect the clinical handling but is still within acceptable limits. The compressive strength for both standard and modified cements was within the range of thin trabecular bone; therefore, both CPCs can withstand equal mechanical loading. The faster diminishing compressive strength of modified cement from 24 h to 8 weeks likely results in early breakdown and so might be favorable for bone regeneration. Together with the beneficial effects on bone regeneration from the addition of rhTGF-beta1 to CPC, as shown in our previous studies, we conclude that the envisaged applications for CPC in bone defects are upgraded by the intermixing of rhTGF-beta1. Therefore, the combination of CPC and rhTGF-beta1 forms a promising synthetic bone graft.

Bone Cements↗

Extensive porosity at the cement-femoral prosthesis interface: a preliminary study.

This study is the first description of the extensive porosity which is preferentially located at the cement-prosthesis interface of cemented femoral components of total hip replacements. The observation is important because the interfacial porosity may decrease the strength of the cement-femoral prosthesis interface and jeopardize the mechanical integrity of the cement mantle. We examined the cement-metal interfaces from a multiplicity of in vivo and in vitro specimens using both optical and scanning electron microscopy. These samples included several stem designs, implants made from either Co-Cr or Ti alloy, implants made with a variety of surface finishes and both centrifuged and uncentrifuged cement. All in vivo and in vitro samples had marked porosity in the cement focally concentrated at the cement-metal interface. The amount of porosity at the interface greatly exceeded the amount of general porosity found throughout the bulk cement. Centrifuging did not affect the interfacial porosity, and neither did alloy nor surface finish. The presence of these pores may be explained by the rheological characteristics of the cement.

Alloys↗

Effects of variation of prosthesis size on cement stress at the tip of a femoral implant.

With the resurgence of the use of bone cement in total hip arthroplasty, a renewed interest in techniques or designs that may reduce cement fixation failure has arisen. Analysis of the stresses at the tip of the prosthesis may suggest strategies to reduce loosening. This study analyzed stresses in the cement near the tip of a femoral component as a function of cement thickness, using a three-dimensional finite element model. A section of an idealized circular femoral shaft with implanted prosthesis and cement was modeled with loading conditions representing the stance phase of gait. Increasing cement thickness from 2 to 5 mm by reducing the prosthesis diameter from 15 to 9 mm is predicted to reduce stress significantly in the cement mantle of a femoral implant. Peak tensile stresses are reduced 45%, whereas peak von Mises and shear stresses are reduced 40%. Such a reduction in stress can increase fatigue life by an order of magnitude. Peak interface tensile stresses occur on the medial side at the tip of the prosthesis in a transverse direction, indicating likelihood of failure due to debonding. The shear and tensile stresses predicted by our model greatly exceed the fatigue endurance limit values for both bulk cement and the cement-prosthesis interface, indicating the likelihood of premature fatigue failure, even allowing for considerable uncertainty. These analytical results suggest that the surgeon should adopt a strategy of selecting a prosthesis that permits a 5-mm cement mantle near the tip of the prosthesis.

Bone Cements↗

Preparation of epoxy-SiO2 hybrid sol-gel material for bone cement.

An organic-inorganic hybrid material, epoxy-SiO(2), was prepared by incorporating epoxy structure units covalently into a SiO(2) glass network via the sol-gel approach. The precursor was obtained by the reaction of diglycidyl ether of bisphenol A (DGEBA) with 3-aminopropyl trimethoxysilane (APTS). The precursor was then hydrolyzed and co-condensated with tetraethyl orthosilicate (TEOS) in tetrahydrofuran (THF) at room temperature to yield epoxy-SiO(2) hybrid sol-gel material having a 50 wt % SiO(2) content. Thermal properties of the hybrid material were characterized by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). The hybrid sol-gel material epoxy-SiO(2) was the solid, powder component of bone cement. The liquid component contains bis-phenol-A glycidyl methacrylate (Bis-GMA), triethyleneglycol dimethacrylate (TEGDMA), and methyl methacrylate (MMA) with 25, 55, and 20 vol %, respectively. We discuss the comparison between the new epoxy-SiO(2) bone cement and the commercial Simplex P bone cement. Mechanical properties such as Young's modulus, compressive strength, hardness, and impact strength of the new epoxy-SiO(2) bone cement exceeded those of Simplex P bone cement. The tensile and bending strengths of the new epoxy-SiO(2) bone cement were approximately the same as those of Simplex P bone cement. In order to evaluate the biocompatibility of the new bone cement, an MTT test and optical microscopy were conducted in cell culture. Results indicated that the new epoxy-SiO(2) bone cement exhibits very low cytotoxicity compared with Simplex P bone cement.

Animals↗

Bioactive PMMA bone cement prepared by modification with methacryloxypropyltrimethoxysilane and calcium chloride.

Bone cement consisting of polymethylmethacrylate (PMMA) powder and methylmethacrylate (MMA) liquid is used extensively for fixation of implants such as artificial hip joints with living bone. This type of cement, however, does not show direct bonding to the living body, and hence the fixation is liable to loosen over a long implantation period. Bioactive materials have received much attention because of their capability for bone-bonding, i.e., bioactivity, when implanted in bony defects. Osteoconduction of the bioactive materials is caused by formation of a bone-like apatite layer through a surface reaction between the material and surrounding body fluid. The apatite formation can be induced by a silanol (Sibond;OH) group formed on the materials as well as a dissolution of calcium ion (Ca(2+)) from the material. Incorporation of alkoxysilane and calcium chloride (CaCl(2)) may provide PMMA bone cement with bioactivity, because alkoxysilane gives Sibond;OH after hydrolysis, whereas CaCl(2) releases Ca(2+). In this study, we investigated the potential on bioactivity of the modified PMMA bone cement with alkoxysilane and calcium chloride. PMMA powder was mixed with various amounts of CaCl(2), and MMA liquid with various amounts of 3-methacryloxypropyltrimethoxysilane (MPS). The mixed paste was immersed in a simulated body fluid (Kokubo solution) that has a similar concentration in inorganic constituents to human blood plasma. After soaking for various periods, apatite formation on the cement was examined. Apatite formation was observed by the addition of CaCl(2) with contents of 16 mass % and more. Incorporation of MPS accelerates the apatite formation. Setting time of the cement was significantly elongated after the addition of MPS, whereas compressive strength significantly decreased with increasing the contents of CaCl(2) and MPS. The hardened cement containing 20 mass % of CaCl(2) in the powder and 20 mass % of MPS in the liquid showed a tendency to be more osteoconductive to living bone after implantation in rabbit tibiae than the unmodified cement. These results indicate that bioactivity of the modified PMMA bone cement increases with increasing amounts of MPS and CaCl(2). Bioactive bone cement is successfully obtained when it contains appropriate concentrations of alkoxysilane and calcium chloride.

Animals↗

Complexity in modeling of residual stresses and strains during polymerization of bone cement: effects of conversion, constraint, heat transfer, and viscoelastic property changes.

Aseptic loosening of cemented joint prostheses remains a significant concern in orthopedic biomaterials. One possible contributor to cement loosening is the development of porosity, residual stresses, and local fracture of the cement that may arise from the in-situ polymerization of the cement. In-situ polymerization of acrylic bone cement is a complex set of interacting processes that involve polymerization reactions, heat generation and transfer, full or partial mechanical constraint, evolution of conversion- and temperature-dependent viscoelastic material properties, and thermal and conversion-driven changes in the density of the cement. Interactions between heat transfer and polymerization can lead to polymerization fronts moving through the material. Density changes during polymerization can, in the presence of mechanical constraint, lead to the development of locally high residual strain energy and residual stresses. This study models the interactions during bone cement polymerization and determines how residual stresses develop in cement and incorporates temperature and conversion-dependent viscoelastic behavior. The results show that the presence of polymerization fronts in bone cement result in locally high residual strain energies. A novel heredity integral approach is presented to track residual stresses incorporating conversion and temperature dependent material property changes. Finally, the relative contribution of thermal- and conversion-dependent strains to residual stresses is evaluated and it is found that the conversion-based strains are the major contributor to the overall behavior. This framework provides the basis for understanding the complex development of residual stresses and can be used as the basis for developing more complex models of cement behavior.

Bone Cements↗

Rheological enhancement of mechanically activated alpha-tricalcium phosphate cements.

Most biocements are two- or three-component acid-based systems with large differences in the component particle sizes, which occurs by virtue of the differing processing routes. This work aimed to improve injectability and strength of a single reactive component cement, that is, mechanically activated alpha-tricalcium phosphate (TCP)-based cement by adding 13-33 wt % of several fine-particle-sized (d(50) of 0.5-1.1 microm) fillers [dicalcium phosphate anhydrous (DCPA), titanium dioxide (TiO(2)), and calcium carbonate] to the monomodal alpha-TCP matrix (d(50) = 9.8 microm). A high zeta-potential was measured for all particles in trisodium citrate solution. The fraction of alpha-TCP cement "injected" through an 800-microm hypodermic needle was found to be only 35% at a powder-to-liquid ratio of 3.5 g/mL. In contrast, the use of fillers decreased cement viscosity to a point, where complete injectability could be obtained. Mechanistically, these additives disrupted alpha-TCP particle packing yet decreased the interparticle spacing by a factor of approximately 5.5 such that the electrostatic repulsion effect was enhanced. A strength improvement was found when DCPA and TiO(2) were used as fillers despite the lower degree of conversion of these cements. Compressive strengths of precompacted cement samples increased from 70 MPa for unfilled alpha-TCP cement to 140 (110) MPa for 23 wt % DCPA (or TiO(2)) fillers as a result of porosity reduction. Strength improvement for more clinically relevant uncompacted cements was achieved by higher powder-to-liquid ratio mixes for filled cements such that maximum strengths of 90 MPa were obtained for 23 wt % DCPA filler compared with 50 MPa for single-component alpha-TCP cement.

Biocompatible Materials↗

Biocompatibility of a new radiopaque iodine-containing acrylic bone cement.

Radiopacity in the vast majority of the commercially available acrylic bone cements that are used clinically is provided by particles of either BaSO(4) or ZrO(2). Literature reports have shown these agents to have a detrimental effect on some mechanical properties of the cements as well as on its biological response. We, therefore, have developed a new type of bone cement, for which radiopacity results from the presence of an iodine-containing methacrylic copolymer. The focus of the present work was the comparison of the biocompatibility of this new cement and a commercially available cement that contains barium sulfate. In vitro experiments show that both cements are cytocompatible materials, for which no toxic leachables are found. Implantation of the cements in a rabbit for three months resulted in the occasional presence of a thin fibrous tissue at the cement-bone interface, which is common for acrylic bone cements. Consideration of all the results led to the conclusion that the new cement is as biocompatible as the BaSO(4)-containing one.

Animals↗

Influence of initial component temperature on the apparent viscosity and handling characteristics of acrylic (PMMA) bone cement.

The flow and polymerization characteristics of poly(methylmethacrylate) (PMMA) bone cement can be changed by manipulating the temperature of the bone cement components or the environment that they are prepared in. To quantify the effects of the initial component temperature (T(ic)) of acrylic bone cement on the rheological and handling characteristics, ASTM F451-99a compliant methods and clinically relevant testing methods were utilized. A rheometer was designed and fabricated using the dimensions of a clinical, commercially available, cement gun and nozzle. The influence on the apparent viscosity and handling characteristics (setting time, working time, and peak exotherm temperature) for a high viscosity (HV) commercially-available acrylic bone cement, Palacos R, were determined. The values of T(ic) used were 23 degrees C (room), 6 degrees C (refrigerator), and -14 degrees C (freezer). Using the apparent viscosity of a medium viscosity (MV) bone cement as a benchmark (Simplex P at room temperature), it was found that by adjusting the T(ic) the HV cement was able to mimic the flow characteristics of the MV cement. Lowering the T(ic) lowered the apparent viscosity of the bone cement. The effects of T(ic) on the polymerization of bone cement were studied in dynamic and static conditions. The dynamic test recorded temperature and torque from stirring resistance. Setting times were also determined using the ASTM exotherm mold method. The setting times determined by the dynamic testing conditions were consistently shorter than those determined by the ASTM method. Lowering the T(ic) increased the working and setting times; however, it did not have a significant effect on the peak exotherm temperature.

Bone Cements↗

Influence of stem geometry on mechanics of cemented femoral hip components with a proximal bond.

Nonlinear, three-dimensional, finite element models of cemented femoral hip components with a proximal stem-cement bond were developed with use of a Charnley stem geometry and a modified Charnley stem geometry that had a cylindrical cross section over the distal two-thirds of the stem (Distal-Round). Peak tensile stresses in the proximal cement mantle increased 63 and 74% for the Charnley and Distal-Round stems, respectively, when the proximal stem-cement interface was debonded. The shear stresses over the stem-cement interface with a proximal bond were 29% larger for the Distal-Round stem than for the Charnley stem. After the proximal stem-cement interface was debonded, the peak tensile stresses in the cement mantle were 15% larger for the Distal-Round stem than for the Charnley stem. The results illustrate that stresses within the proximal cement mantle could be substantially reduced for both Charnley and Distal-Round stems through use of a proximal stem-cement bond. However, the risk of debonding may be higher for the Distal-Round stem because of increased shear stresses, and once debonded the risk of further loosening due to failure of the cement mantle would also be higher for the Distal-Round stem.

Bone Cements↗

In vitro strength comparison of hydroxyapatite cement and polymethylmethacrylate in subchondral defects in caprine femora.

Hydroxyapatite cement was investigated in situ for the reconstruction of juxta-articular defects. Polymethylmethacrylate is currently the most commonly used material for the reconstruction of bone defects following the exteriorization and curettage of aggressive benign tumors. In vitro, we compared the effects of hydroxyapatite cement and polymethylmethacrylate in restoring the stiffness of the subchondral plate in a caprine femoral defect model. Ten matched pairs of caprine femora underwent nondestructive compression testing normal to the load-bearing surface. A standardized subchondral defect 12 mm in diameter was created in the medial femoral condyle. Compression testing was repeated to determine the reduction in stiffness caused by the defect. Each femur from each pair was randomly assigned to one of two groups (n=9), and the defects were augmented with either polymethylmethacrylate or hydroxyapatite cement. After 12 hours, compression testing was repeated to determine the subchondral stiffness after augmentation. Compared with intact femora, the defect specimens that were later treated with either polymethylmethacrylate or hydroxyapatite cement exhibited stiffness values of 70 (386+/-107 N/mm) and 59% (343+/-94 N/mm) respectively, which represented a significant reduction in stiffness (p=0.05). Augmentation with polymethylmethacrylate or hydroxyapatite cement restored stiffness by 81 (450+/-111 N/mm) and 71% (413+/-115 N/mm), respectively, of the values of intact specimens. Hydroxyapatite cement restored stiffness significantly (p=0.05) over the stiffness of the nonaugmented defect compared with the stiffness after augmentation with polymethylmethacrylate (p=0.12). Neither polymethylmethacrylate nor hydroxyapatite cement restored stiffness to that of intact femora (p=0.05). In the current detect model, hydroxyapatite cement was comparable with polymethylmethacrylate in restoring subchondral stiffness. Unlike polymethylmethacrylate, however, hydroxyapatite cement has the following advantages: it is osteoconductive, is replaced by host bone, and avoids the potential for thermal necrosis. Hydroxyapatite cement may therefore provide a viable alternative to polymethylmethacrylate for augmentation of juxta-articular and other bone defects.

Animals↗

Antimicrobial efficacy of gentamicin-loaded acrylic bone cements with fusidic acid or clindamycin added.

The increasing gentamicin resistance among bacteria in septic joint arthroplasty has stimulated interest in adding a second antibiotic into gentamicin-loaded bone cement. A first aim of this in vitro study is to investigate whether addition of fusidic acid or clindamycin to gentamicin-loaded bone cement has an additional antimicrobial effect against a collection of 38 clinical isolates, including 16 gentamicin-resistant strains. A modified Kirby-Bauer test, involving measurement of the inhibition zone around antibiotic-loaded bone cement discs on agar plates, was used to investigate whether adding a second antibiotic has an additional antimicrobial effect. Second, a selected number of strains was used to study their survival in an interfacial gap made in the different bone cements to mimic the gap between bone and cement as existing near a prosthesis. Gentamicin-loaded bone cement had an antimicrobial activity against 58% of the 38 bacterial strains included in this study, while 68% of the strains were affected by bone cement loaded with a combination of gentamicin and clindamycin. Bone cement loaded with the combination of gentamicin and fusidic acid had antimicrobial activity against 87% of the bacterial strains. In the prosthesis-related gap model, there was a clear trend toward less bacterial survival for gentamicin-loaded bone cement after adding clindamycin or fusidic acid. Addition of clindamycin or fusidic acid into gentamicin-loaded bone cement yields an additional antimicrobial effect. The combination gentamicin and fusidic acid was effective against a higher number of clinical isolates than the combination of gentamicin with clindamycin, including gentamicin-resistant strains.

Anti-Bacterial Agents↗

[New PMMA bone cements for vacuum mixing systems].

In cemented total hip replacement, fractures and cracks in the cement mantle may facilitate mechanical loosening of the prosthesis. Especially large voids and flaws within the cement can cause fatigue fractures. Reduction of cement porosity is a logical step in the attempt to improve the quality and durability of bone cement. An effective reduction of pores during vacuum mixing requires prechilling of Palacos R at 4 degrees C. For easier handling, new bone cements have been developed with characteristics similar to Palacos R, but with no chilling necessary prior to mixing under vacuum. In our study two newly developed bone cements (Palamed G, VersaBond) and a bone cement used widely in clinics (Palacos R) were mixed in three different vacuum mixing systems (Optivac, MixOR, Palamix). Macro-, micro-, and total porosity and bending strength (ISO 5833) were determined. All three mixing systems proved effective in reducing porosity and showed constant mixing results. All cement specimens that we tested fulfilled the ISO requirements for bending strength. VersaBond yielded the lowest porosities, but showed lower viscosity compared to Palacos R and Palamed G. The new cements are equal in vitro to Palacos R with regard to bending strength, but further clinical studies are necessary before widespread use is advisable.

Arthroplasty, Replacement, Hip↗

[Fat embolism during total hip arthroplasty. Cementless versus cemented--a quantitative in vivo comparison in an animal model].

Thrombembolic complications,which include the fat embolism syndrome, are well-known consequences of cementless and cemented femoral total hip replacement. Thrombembolic phenomena have been demonstrated in clinical and experimental situations with both these fixation techniques, but so far no exact quantification of the intravasated fat emboli has been performed. In a standardized animal model in 15 Merino sheep we investigated the intravasation of fat into the bloodstream during simultaneous bilateral prosthetic implantation (cemented versus cementless). After identical preparation of the intramedullary canal on both sides, a cement restrictor was additionally inserted on the cemented side and the canal was cleaned by 250 ml jet lavage. Catheters in the external iliac veins made it possible to collect the drained blood in two phases, after preparation of the intramedullary canal and during insertion of the prosthesis, and the fat content of these blood samples was measured. The amount of fat that passed into the venous draining system of the femur induced by cemented implantation (2.2749 g; S=+/-1.0079) was twice the amount seen with cementless implantation (1.1586 g; S=+/-0.4555) ( P=0.0002). An obvious effect of the canal preparation was recognizable with the cemented implantation, 8 of the 13 animals evaluated showing a peak in the fat intravasation caused by application of the cement restrictor. Our results emphasize the importance of a thorough preparation of the intramedullary canal, particularly when cemented fixation is performed. The jet lavage,which should be considered mandatory standard in cemented total hip arthroplasty, should be implemented before the insertion of the cement restrictor in order to further reduce the risk of fat embolism.

Animals↗

Cement from magnesium substituted hydroxyapatite.

Brushite cement may be used as a bone graft material and is more soluble than apatite in physiological conditions. Consequently it is considerably more resorbable in vivo than apatite forming cements. Brushite cement formation has previously been reported by our group following the mixture of nanocrystalline hydroxyapatite and phosphoric acid. In this study, brushite cement was formed from the reaction of nanocrystalline magnesium-substituted hydroxyapatite with phosphoric acid in an attempt to produce a magnesium substituted brushite cement. The presence of magnesium was shown to have a strong effect on cement composition and strength. Additionally the presence of magnesium in brushite cement was found to reduce the extent of brushite hydrolysis resulting in the formation of HA. By incorporating magnesium ions in the apatite reactant structure the concentration of magnesium ions in the liquid phase of the cement was controlled by the dissolution rate of the apatite. This approach may be used to supply other ions to cement systems during setting as a means to manipulate the clinical performance and characteristics of brushite cements.

Bone Cements↗

Strength of cement-metal interfaces in fatigue: comparison of smooth, porous and precoated specimens.

Radiographic follow-up studies of cemented total hip arthroplasty have shown that failure of the cement-metal interface of the femoral component is as high as 25% at 10 years. Recent analyses of clinically successful cemented femoral components obtained in toto with the surrounding cement and femurs after many years of in-vivo service have suggested that the mechanism of the initiation of failure of fixation of cemented femoral components is debonding at the cement-metal interface. Since this critical interface is subjected primarily to cyclic loading, the evaluation of different surface preparations should be studied in fatigue, not static testing. In the current study, several contemporary methods for increasing the strength of the cement-metal interface were evaluated by testing the interfacial fatigue pushout strength under varying conditions of cyclic loading. The effect of a smooth 'implant finish' surface, a surface coated with polymethylmethacrylate (PMMA precoated surface), a combination of a textured surface with PMMA precoat, and a porous titanium mesh coated surface were examined. Precoating the metal with a thin film of PMMA significantly increased the number of compressive fatigue loading cycles required for failure of the cement-metal interface under cyclic loading compared to a smooth, uncoated surface. Adding indentations to the surface and then precoating with PMMA further significantly increased the fatigue life of the cement-metal interface. The strongest interface in fatigue was the titanium fibermesh-cement interface.

Bone Cements↗

The role of cemented sockets in 2004: is there one?

Cement fixation of the acetabular cup in total hip arthroplasty (THA) has evolved through multiple generations of cement technology. Whereas cement technology has produced improvements in cemented femoral fixation, the cemented socket still produces inconsistent results. Even with our current knowledge that cemented cups require exposure of cancellous bone, a clean and dry socket, and adequate bony coverage of the cup, surgeons such as myself are unable to control radiolucency at the bone-cement interface. The technical difficulty of cementing the acetabular cup has led to the increasing prevalence of cementless acetabular cups. Although cementless fixation has resulted in increased incidence of osteolysis, the surgical procedure is less technically demanding, and the long-term mechanical fixation results have been more consistent. Given the experiential learning curve that most orthopedic surgeons face with cemented fixation of the acetabular cup component, the role of the cemented socket in THA today is limited.

Acetabulum↗

Mechanical characterization of resin cements used for luting fiber posts by nanoindentation.

OBJECTIVES: To evaluate the mechanical behavior of resin cements used for luting fiber post. The influence of the curing mode is analysed. METHODS: Nanoindentation techniques have been applied to determine hardness and Young's modulus of disc-shaped specimens of three types of cements: chemical- , photo- and dual-cured, provided by Ivoclar-Vivadent. Results obtained have been compared with measurements performed inside the post-cement-dentin system. Mechanical properties are evaluated together with scanning electron micrographs showing the post-cement and dentin-cement interfaces. RESULTS AND SIGNIFICANCE: Differences have been detected between mechanical measurements performed inside the post-cement-dentin system and those carried out in laboratory disc-shaped specimens. The close presence of post and dentin boundaries has a lot of influence on the cement behavior. The nanoindentation measurements indicate that the photo-cured cement exhibits a high hardness and stiffness, but with a more marked tendency to brittle failure. The chemically cured cement is the material with higher ability to bear deformation without damage, although its hardness and elastic modulus are significantly lower. Dual-cured cements present the best combination of properties.