A colorimetric assay for heme in biological samples using 96-well plates.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A method for quantification of unlabeled alpha-tocopherol and the deuterated tocopherols, RRR-alpha-5-(CD(3))-tocopherol (d(3)RRR) and all rac-alpha-5,7-(CD(3))(2) tocopherol (d(6)all-rac) in plasma by HPLC-tandem mass spectrometry (LC-MS/MS) has been developed. Deuterated and unlabeled alpha-tocopherols were separated by HPLC and were detected by positive ion multiple-reaction monitoring using a triple-quadrupole mass spectrometer equipped with a heated nebulizer-atmospheric pressure chemical ionization interface, following routine extraction of vitamin E from plasma. The accuracy and precision were evaluated by replicate analysis of standards and samples. Human plasma samples, which were obtained at different times after the subject had consumed a capsule containing 1:1 ratio of d(3)RRR and d(6)all rac-alpha-tocopheryl acetates, were analyzed with this method. Plasma deuterated alpha-tocopherols measured by LC-MS/MS followed the same pattern as previously demonstrated by GC-MS measurement, without requiring an extra derivitization step. The detection limit was 10 pmol for each form of alpha-tocopherol injected.
Asymmetric dimethylarginine (ADMA), an endogenous inhibitor of nitric oxide synthase (NOS), may be related to reduced biosynthesis of nitric oxide in diseases associated with accelerated atherosclerosis. The closely related compound symmetric dimethylarginine (SDMA) does not inhibit NOS, but may compete with arginine for cellular uptake, thereby limiting substrate availability for NOS. We report on a method for the simultaneous measurement of arginine, ADMA, and SDMA as a tool to gain insight in the role of these compounds in the regulation of NOS activity. Sample cleanup was performed by solid-phase extraction on polymeric cation-exchange columns using monomethylarginine as internal standard. After derivatization with ortho-phthaldialdehyde reagent containing 3-mercaptopropionic acid, analytes were separated by isocratic reversed-phase HPLC with fluorescence detection. The stable derivatives were separated with near baseline resolution. Using a sample volume of 0.2 ml, linear calibration curves were obtained with limits of quantification of 0.08 microM for arginine and 0.01 microM for ADMA and SDMA. Analytical recovery was 98-102%, and interassay CV was better than 3%. Plasma from healthy volunteers (n = 53) contained 94 +/- 26 microM arginine, 0.42 +/- 0.06 microM ADMA, and 0.47 +/- 0.08 microM SDMA. Due to its high precision and sensitivity this method is a valuable tool in research on the metabolism of dimethylated arginines and their role in the regulation of NOS activity.
We have used Leginon, a fully automatic system capable of acquiring cryo-electron micrographs, to collect data of single particles, specifically of the AAA ATPase p97. The images were acquired under low-dose conditions and required no operator intervention other than the initial setup and periodic refilling of the cold-stage dewar. Each image was acquired at two different defocus values. Two-dimensional projection maps of p97 were calculated from these data and compared to results previously obtained using the conventional manual data collection methods to film. The results demonstrate that Leginon performs as well as an experienced microscopist for the acquisition of single-particle data. The general advantages of automation are discussed.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Minisatellite or variable number of tandem repeat (VNTR) regions contain such a high degree of polymorphism that they allow one to construct an individual-specific DNA "fingerprint". Analysis of these sequences by Southern blot however, consumes much DNA and is not applicable to degraded DNA samples often recovered from body-fluid stains found at crime scenes. The polymerase chain reaction (PCR) technique may overcome these problems. With oligonucleotide primers flanking the repeat region, amplification of the VNTR alleles followed by direct visualization on ethidium bromide-stained agarose gels is possible. In those cases were the PCR yield is too low for direct visualization, the product can be blotted to a nylon membrane and hybridized with a labelled internal probe. Alternatively, the PCR product can be biotinylated during amplification and visualized by direct chemiluminescence after Southern transfer. The remarkable sensitivity of the PCR technique has allowed the detection of genetic polymorphisms in single cells, hair roots and single sperm. A drawback of this very high sensitivity however is that special precautions have to be taken to prevent accidental contamination resulting in erroneous interpretation of the results.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A sensitive and specific radioimmunoassay for adenosine has been developed. Antibodies directed against adenosine (titer 1:400--1:700) were obtained by immunizing rabbits with adenosine, conjugated via its vicinal hydroxyl groups to bovine serum albumin (periodate oxidation). Interfering adenosine deaminase activity was removed from the antisera by treatment with DEAE-cellulose. Free and antibody bound 3H-adenosine was separated by either the "second antibody" precipitation method or by a simple filtration step. The sensitivity and assay range for adenosine was 1--100 pmoles per assay tube. Structurally related purine compounds (adenine nucleotides, adenine) crossreacted with adenosine binding and were removed by a single chromatographic step. Analysis of the adenosine content in normoxic guinea pig hearts yielded 2.53 nmoles/g, a value which was confirmed by spectrophotometric analysis.
Explore the source record for details and available documents.
Racemic amino acids can be separated into their enantiomers by means of gas-liquid chromatography. The most applied technique, today, is the conversion of chiral compunds into diastereoisomers with optically active reagents and subsequent chromatography on conventional optically inactive stationary phases. In previous studies it has been realized that this technique is associated with various problems. We studied the use of optically active stationary phases for separating enantiomers directly via a diastereoisomeric association complex. The optically acitve stationary phases employed are N- and C-terminal substituted dipeptides of the type N-trifluoroacetyl-dipeptide-cyclohexyl esters and have been synthesised by the I-hydroxibenztriazole dicyclohexylcarbodiimide method. The quality of these phases with respect to separation factors, resolution factors, and thermodynamical properties have been evaluated. All synthetic phases show excellent properties; however, when attempting separation of mixtures of naturally occurring amino acids extensive overlap in the elution diagram was detected. Only one phase - N-TFA-L-chi-amino-n-butyryl-L-chi-amino butyric acid cyclohexyl ester - gave complete resolution of the naturally occurring amino acids alanine, valine, glycine, threonine, leucine, isoleucine, serine and proline on a 400 ft x 0.02 in capillary column. Less volatile amino acids such as aspartic acid, phenylalanine, methionine, glutamic acid, tyrosine, arginine, and tryptophan can be resolved at a 100 ft x 0.02 in column.
A modified method by means of absorption of AsH3 in chloroform with an addition of 0,5% hexamethylene-tetramine is described. The detection limit amounts to 0,5 mug arsenic. Arsenic contents of some higher burdened foodstuff are amended.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.