Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLATES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45Linked to original sources

Interaction of Eu(III)/Cm(III) with alumina-bound poly(acrylic acid): sorption, desorption, and spectroscopic studies.

This paper contributes to the comprehension of kinetic and equilibrium phenomena governing trace metal ion sorption on organic matter coated mineral particles. Sorption and desorption experiments were carried out with trivalent metal ions M(III) (M = Eu, Cm) and poly(acrylic acid) (PAA)-coated alumina colloids at pH 5 in 0.1 M NaClO4. Under these conditions, M(III) interaction with the solid is governed by sorbed PAA. The results were compared with spectroscopic data obtained by time-resolved laser-induced fluorescence spectroscopy (TRLFS). Within less than 30 s, a state of local equilibrium is reached between M(III) and adsorbed poly(acrylic acid). M(II) bound to the organic-mineral surface and to dissolved PAA keeps five water molecules in its first hydration sphere. Interaction of M(III) with alumina-bound PAA appears to be strongerthan with dissolved PAA. With increasing contact time, a change of the metal ion speciation occurs at the organic-mineral surface. This change is explained quantitatively by kinetically controlled reactions, which succeed a rapid local equilibrium. The experimental findings suggest, in agreement with model calculations, that a part of the initially sorbed M(III) is slowly converted to a kinetically stabilized species, thereby losing water molecules from the first coordination sphere as indicated by TRLFS. This species might be assigned as a ternary Al2O3-M(III)-PAA complex. The second part of the initially bound M(II) appears to experience as well kinetically controlled reactions, however, without showing changes in the first coordination sphere. We assume that the kinetic stabilization is the consequence of rearrangement processes of the PAA at the alumina surface.

Acrylates↗

Highly effective chiral ortho-substituted BINAPO ligands (o-BINAPO): applications in Ru-catalyzed asymmetric hydrogenations of beta-aryl-substituted beta-(acylamino)acrylates and beta-keto esters.

A novel family of chiral ortho-substituted BINAPO ligands (o-BINAPO) were synthesized from BINOL, and their Ru complexes were highly efficient catalysts for asymmetric hydrogenation of beta-aryl-substituted beta-(acylamino)acrylates and beta-aryl-substituted beta-keto esters. The Ru-bisphosphinite catalysts can tolerate an E/Z mixture of beta-aryl-substituted beta-(acylamino)acrylates. These highly enantioselective hydrogenations provide a useful way to prepare beta-aryl-substituted beta-amino acids and beta-hydroxyl acids.

Acrylates↗

Potent nonpeptide angiotensin II receptor antagonists. 2. 1-(Carboxybenzyl)imidazole-5-acrylic acids.

The further evolution of the imidazole-5-acrylic acid series of nonpeptide angiotensin II receptor antagonists is detailed (for Part 1, see: J. Med. Chem. 1992, 35, 3858). Modifications of the N-benzyl ring substitution were undertaken in an effort to mimic the Tyr4 residue of angiotensin II. Introduction of a p-carboxylic acid on the N-benzyl ring resulted in the discovery of compounds with nanomolar affinity for the receptor and good oral activity. SAR studies of these potent antagonists revealed that the thienyl ring, the (E)-acrylic acid, and the imidazole ring in addition to the two acid groups were important for high potency. Also, overlay comparisons of the parent diacid with both angiotensin II and a representative biphenylyltetrazole nonpeptide angiotensin II receptor antagonist are presented. The parent diacid analog, SK&F 108566 or (E)-3-[2-butyl-1-(4-carboxybenzyl)-1H-imidazole-5-yl]-2-[(2- thienyl)methyl]propenoic acid, is currently in clinical development for the treatment of hypertension.

Acrylates↗

Studies on antianaphylactic agents. 4. Synthesis and structure-activity relationships of 3-(4-oxo-4H-1-benzopyran-3)acrylic acids, a new series of antiallergic substances, and some related compounds.

The syntheses of trans-3-(4-oxo-4H-1-benzypyran-3)acrylic acid and a number of analogs shown to be highly active in antiallergic bioassays are described. These compounds are of possible value in the treatment of asthma. The structural requirements for biological activity are discussed with reference to the type of the substituents on the chromone ring or positions of linkage of the acrylic acid on the pyrone ring.

Acrylates↗

Differences in binding of a cationic surfactant to cross-linked sodium poly(acrylate) and sodium poly(styrene sulfonate) studied by Raman spectroscopy.

Raman spectroscopy has been used to investigate the structure of gel-surfactant complexes. Cross-linked sodium poly(acrylate) and sodium poly(styrene sulfonate) were immersed in solutions of the cationic surfactant dodecyl trimethylammonium bromide. During the deswelling process, two distinct regions could be observed for both types of gels. Looking at the Raman spectra, however, for the poly(styrene sulfonate), the surfactant could be found throughout the gel particle, whereas for poly(acrylate), essentially all the surfactant was bound in a surface layer.

Acrylic Resins↗

Functional and surface-active membranes from poly(vinylidene fluoride)-graft-poly(acrylic acid) prepared via RAFT-mediated graft copolymerization.

Poly (vinylidene fluoride) (PVDF) with "living" poly (acrylic acid) (PAAc) side chains (PVDF-g-PAAc) was prepared by reversible addition-fragmentation chain transfer (RAFT)-mediated graft copolymerization of acrylic acid (AAc) with the ozone-pretreated PVDF. The chemical composition and structure of the copolymers were characterized by elemental analysis, Fourier transform infrared spectroscopy, and thermogravimetric analysis. The copolymer could be readily cast into pH-sensitive microfiltration (MF) membranes with enriched living PAAc graft chains on the surface (including the pore surfaces) by phase inversion in an aqueous medium. The surface composition of the membranes was determined by X-ray photoelectron spectroscopy. The morphology of the membranes was characterized by scanning electron microscopy. The pore size distribution of the membranes was found to be much more uniform than that of the corresponding membranes cast from PVDF-g-PAAc prepared by the "conventional" free-radical graft copolymerization process. Most important of all, the MF membranes with surface-tethered PAAc macro chain transfer agents, or the living membrane surfaces, could be further functionalized via surface-initiated block copolymerization with N-isopropylacrylamide (NIPAAM) to obtain the PVDF-g-PAAc-b-PNIPAAM MF membranes, which exhibited both pH- and temperature-dependent permeability to aqueous media.

Acrylic Resins↗

Subcritical failure of soft acrylic adhesives under tensile stress.

The mechanisms of failure over time of a series of model acrylic pressure-sensitive adhesives under a moderate level of stress has been investigated with a probe method. Two competing mechanisms of failure have been observed: a progressive nucleation of cavities under stress and the propagation of existing cavities at the interface between the probe and the adhesive layer. Homogeneous creep of the adhesive was never observed as the only failure mechanism. In situations where the resistance to crack propagation was good relative to the resistance to cavitation, extensive nucleation of cavities was observed until a material-dependent and stable value of stress was achieved. On the other hand in situations were the resistance to crack propagation was weak, propagation led invariably to a complete failure of the adhesive bond. In addition to the stress relaxation, the energy dissipation was studied allowing to distinguish the different adhesives even further. This allowed determination of the optimal amount of a comonomer (acrylic acid) that had to be added to improve the long-term resistance of the adhesives under study. Further more we investigate the compliance of the confined adhesive layers and compare the obtained results to predictions from theoretical models.

Acrylates↗

High-capacity binding of proteins by poly(acrylic acid) brushes and their derivatives.

Polymeric coatings with high protein-binding capacities are important for increasing the output of affinity-based protein purification and decreasing the detection limits of antibody microarrays. This report describes the use of thick poly(acrylic acid) (PAA) brushes to immobilize as much as 80 monolayers of protein. The brushes were prepared using a recently developed procedure that allows polymerization of 100-nm-thick poly(tert-butyl acrylate) films from a surface in just 5 min along with hydrolysis of these films to PAA in 15 min. Covalent binding of bovine serum albumin (BSA) to PAA brushes that were activated using standard coupling agents, however, resulted in immobilization of less than two monolayers of BSA because of competitive hydrolysis of the esters in the activated film. In contrast, derivatization of PAA with nitrilotriacetate (NTA)-Cu2+ complexes yielded films capable of binding many monolayers of protein via metal-ion affinity interactions. For example, derivatization of 55-nm-thick PAA films with NTA-Cu2+ allowed immobilization of about 15 monolayers (5.8 microg/cm2 or 58 nm) of BSA. The binding capacity was even higher for myoglobin (7.7 microg/cm2) and anti-IgG (9.6 microg/cm2). Remarkably, electrostatic adsorption of lysozyme in 55-nm-thick, underivatized PAA resulted in as much as 80 monolayers (16.2 microg/cm2 or 162 nm) of adsorbed protein. Polymer synthesis, derivatization, and swelling, as well as BSA immobilization kinetics and thermodynamics were characterized using reflectance FT-IR spectroscopy, ellipsometry, and protein assays.

Acrylic Resins↗

Stereoselective synthesis of trans beta-lactams through iridium-catalyzed reductive coupling of imines and acrylates.

[reaction: see text] Iridium-catalyzed reductive coupling of acrylates and imines provides trans beta-lactams with high diastereoselection. The optimal catalyst allows for the synthesis of trans beta-lactams bearing aromatic, alkenyl, and alkynyl side chains. This reaction appears to proceed through a reductive Mannich addition-cyclization mechanism. Examination of substituent effects reveals a linear Hammett correlation for both the N-aryl group on the imine and the aryloxy group on the acrylate, thereby pointing to rate-determining cyclization in the reaction mechanism.

Acrylates↗

Mechanisms of mucoadhesion of poly(acrylic acid) hydrogels.

It has been proposed that mucoadhesives which adhere to the gastric mucus layer may be used to prolong gastric retention time of oral dosage forms. Preliminary studies, using acrylic hydrogels, have established that the density of carboxyl groups on the polymer chain is important for mucoadhesion. To understand the role(s) of the carboxyl groups in mucoadhesion, acrylic acid-acrylamide random copolymers [P(AA-co-AM)] were synthesized, and the adhesion strength of the cross-linked polymers to the gastric mucus layer was examined as a function of the pH, initial concentration of the cross-linking agent, degree of swelling, and carboxyl-group density. From the study on mucoadhesion of various P(AA-co-AM), it was found that at least 80% of the vinyl groups of the polymer must possess carboxyl groups in the protonated form. The dependence of mucoadhesion on pH and carboxyl-group density suggests that mucoadhesion occurs through hydrogen bonding. In addition, the density of the cross-linking agent significantly affects mucoadhesion. As the density of the cross-linking agent is lowered, the mucoadhesive strength increases, although the density of carboxyl groups in the test surface area is reduced. It is concluded that for mucoadhesion to occur, polymers must have functional groups that are able to form hydrogen bonds above the critical concentration (80% for vinyl polymers), and the polymer chains should be flexible enough to form as many hydrogen bonds as possible.

Acrylic Resins↗

Candida glabrata, an emerging fungal pathogen, exhibits superior relative cell surface hydrophobicity and adhesion to denture acrylic surfaces compared with Candida albicans.

Oral candidosis is a common opportunistic infection in debilitated individuals and Candida glabrata is the second most frequently isolated species from this condition, after Candida albicans. Candidal adherence to various biological or non-biological surfaces is considered a prerequisite for colonization, and pathogenesis of candidal infections, and their relative cell surface hydrophobicity (CSH) is likely to be a possible contributory force involved in this process. Whereas a large body of data on the latter features of C. albicans is available, there is surprisingly little information on C. glabrata. As a comprehensive database on the relative adhesion and CSH of Candida spp. is instructive and useful, we investigated in vitro the latter attributes of 34 oral isolates of C. glabrata and 15 isolates of C albicans. There were remarkable intraspecies differences in both the CSH and the adhesive ability of C. glabrata strains (p < 0.001). Compared with C. albicans, C glabrata demonstrated a four-fold greater CSH value (30.63 +/- 11.20% vs 7.23+/-3.56%, p < 0.0001) and a two-fold greater tendency to adhere to denture acrylic surfaces (75.18 +/- 39.96 vs 30.36+/-9.21, p < 0.0001). A significant positive correlation between CSH and adhesion was also noted for both C. glabrata (r=0.674, p < 0.0001) and C. albicans ( r = 0.636, p < 0.05). When the effect of different incubation conditions on the relative CSH and adherence of C. glabrata was examined, CSH and the adherence to acrylic surfaces of four of six C. glabrata isolates were significantly affected by a reduction of the culture temperature (from 37 degrees C to 25 degrees C). A positive relationship also emerged when the temperature-induced variations in the adherence values were correlated with their relative CSH. These data provide hitherto unavailable archival information on important pathogenic attributes of the two most common oral Candida species that may help explain their predominance in this milieu.

Acrylic Resins↗

A comparison of visual performance between a rigid PMMA and a foldable acrylic intraocular lens.

PURPOSE: To examine post-operative visual outcomes when using micro-incision surgery and a three-piece, foldable acrylic intraocular lens (IOL) and when using small-incision surgery and a one-piece, rigid polymethyl-methacrylate (PMMA) IOL. METHODS: Phacoemulsification and IOL implantation was conducted by one surgeon on 86 subjects (aged 50-89 years) with cataracts. Of these subjects, 67 completed the study. Subjects were implanted either with a foldable IOL (n = 38) or a rigid IOL (n = 29). Best corrected Snellen visual acuity and contrast sensitivity (2-28 cycles/degree) were measured approximately 2 months post-operatively. Comparisons were made between the pseudophakic groups and an additional group of 28 age-matched, normal subjects (aged 58-81 years). Non-parametric (Kruskal-Wallis and Mann-Whitney U) as well as parametric (ANOVA and Pearson) statistics tests were used in the analysis of results. RESULTS: All pseudophakes had corrected visual acuity of 6/9 or better. There were no significant differences in visual acuity (Kruskal-Wallis, p = 0.61) or contrast sensitivity (ANOVA, p = 0.33) between the three groups. The mean residual refractive error of the foldable IOL group was hypermetropic in comparison with the rigid IOL group but not significant at the 99% level of probability (Mann-Whitney U, p = 0.02). There was no significant difference in astigmatism between the groups. CONCLUSIONS: Implanting a foldable acrylic IOL gave no post-operative benefit in visual acuity and contrast sensitivity to pseudophakes over a less expensive rigid PMMA IOL, within this post-operative period. This study did not provide a comparison between the two lenses regarding post-operative complications, in particular the important long-term complication of posterior capsular opacification (PCO). Until and if any particular advantage of a given IOL in reduced incidence of PCO is confirmed, it appears more economical to implant the conventional rigid PMMA IOL using small-incision surgery.

Acrylic Resins↗

Characterization of acrylic polyamide plastic embolization particles in vitro and in human tissue sections by light microscopy, infrared microspectroscopy and scanning electron microscopy with energy dispersive X-ray analysis.

Vascular embolization is a well-established practice for the treatment of tumors and vascular lesions. Rounded beads (microspheres) of various materials (collagen, dextran and trisacryl-polymer-gelatin) were developed to solve problems encountered with earlier versions of embolic material. We performed histochemistry, Fourier transform infrared microspectroscopy and scanning electron microscopy with energy dispersive X-ray analysis on two uterine and one hepatic specimen with unidentified intravascular foreign material, and examined a reference embolization product for comparison. The hematoxylin and eosin stained tissue sections showed multiple foci with unidentified intravascular foreign material and fibrous obliteration of vessel lumens. Only one case had a clinical history of previous embolization but without specifying the material used. One case was submitted for identification of a 'parasite'. The material stained positively with Sirius red and mucicarmine, variably with Masson's trichrome stain and Movat pentachrome, and did not stain centrally with periodic acid Schiff with diastase. Infrared spectrophotometric analysis of the material from all three cases demonstrated the spectrum of acrylic polyamide plastic. A control sample of EmboGold exhibited infrared microspectroscopic spectra similar to the three tissue specimens. Analysis by scanning electron microscopy with energy dispersive X-ray analysis demonstrated some differences in elemental composition between the tissue sections and the selected reference material. To our knowledge, this is the first report of infrared spectrophotometric analysis with scanning electron microscopy with energy dispersive X-ray analysis of an acrylic polyamide plastic embolization product both in vitro and in human histologic tissue sections. In cases lacking appropriate clinical information, identification by these methods and/or a panel of special stains may assist pathologists unfamiliar with this material's light microscopic appearance.

Acrylic Resins↗

Migraine: the effect of acrylic appliance design on clinical response.

This study aimed to evaluate the relationship between the nocturnal wearing of an acrylic appliance of 2 mm thickness covering all occlusal surfaces of the teeth and the frequency of attacks of migraine. Nineteen patients were studied and all fulfilled accepted criteria for migraine with or without aura. Two appliance designs were employed, one covering the maxillary occlusal surfaces of the dentition and another which contacted the palatal mucosa only and was free of the occlusion. Treatment outcome was expressed as the number of attacks of migraine per week per patient. The occlusal cover appliance reduced the number of attacks on average to about 40% of that normally experienced. The improvement was most marked in those who had frequent attacks of migraine ie two attacks per week on a regular basis. In summary, acrylic appliance therapy is of value in migraineurs who have attacks on waking but the appliance design has to involve covering of the occlusal surfaces of all of the teeth.

Acrylic Resins↗

Fitting acrylic occlusal splints and an experimental laminated appliance used in migraine prevention therapy.

OBJECTIVE: To evaluate clinical procedures and chair time required to seat and adjust hard, heat-cured acrylic occlusal splints and an alternative laminated appliance developed to simplify construction of migraine prevention appliances. DESIGN AND SETTING: Single-centre study in the Oral Medicine Clinic, The Royal Hospitals, Belfast, Northern Ireland. METHOD: Questionnaires were distributed, January-May 2003, to operators fitting occlusal splints for 100 consecutive patients selected for migraine prevention therapy. Half the appliances were made in heat-polymerised acrylic with the remainder using a novel combination of ethylene vinyl acetate and light-curing urethane dimethacrylate. Information on operator experience, the nature of any fitting surface and occlusal adjustments together with an estimate of the time taken to make alterations was recorded. KEY FINDINGS: The need for adjustment to seat appliances intraorally was significantly less for migraine prevention appliances made using an experimental laminating technique. Where modifications were necessary, there was no significant difference in the chair time required to fit either the heat-cured hard or experimental laminated migraine prevention appliance. CONCLUSION: Provision of migraine prevention appliances may be more time efficient if the dental practitioner considers a laminated approach to construction.

Acrylic Resins↗

The effect of lens design on dysphotopsia in different acrylic IOLs.

PURPOSE: To compare the incidence and severity of all grades of dysphotopsia in three types of acrylic intraocular lenses: the Acrysof MA30 BA and MA60 BM IOLs (Alcon) and the Akreos Fit one-piece IOL (Bausch and Lomb). METHODS: In all 111 patients were prospectively recruited who had undergone uncomplicated cataract surgery in the previous 12 months. Patients were assessed using a combination of a questionnaire and standardised provocation test, and were scored on a grading scale of 0-6 (0 indicating no glare and 6 indicating the most severe symptoms). RESULTS: The overall incidence of dysphotopsia was 77.7%. Patients with absent or mild symptoms (scoring 2 or less on the grading scale) were greater in the group implanted with the Akreos IOLs (49/65 eyes, 75%) as opposed to (44/92 eyes, 48%) of the eyes implanted with Acrysof lenses. Patients with more marked symptoms of glare as judged by scores of 5-6 were uncommon, but more prevalent in the Acrysof lenses (12/92 eyes, 13%) compared to the Akreos lenses (3/65 eyes, 4.6%) respectively. Statistically the Mann-Whitney test showed that there was significantly less dysphotopsia with the Akreos lens when compared to the Acrysof MA30 (P=0.005) and MA60 lenses (P=0.002). CONCLUSION: This study demonstrates that dysphotopsia symptoms are commonly seen in certain brands of Acrylic IOLs. However, differences in design (not only related to the edge) significantly reduce the incidence of moderate and severe grades of dysphotopic symptoms.

Acrylic Resins↗

Determination of acrylic acid in air by using diffusion denuder tubes combined with HPLC technique.

A procedure for the determination of atmospheric acrylic acid in air at the microgram m-3 to mg m-3 level is described. Diffusion-based sampling, designed to discriminate gaseous analytes from their particulate counterparts, has been used. Acrylic acid is collected with an efficiency of > 98% in tubular denuders coated with sodium hydroxide-barium hydroxide-hydroquinone monomethyl ether, and analyzed by high performance liquid chromatography with UV absorbance detection. The detection limit is 2.9 micrograms m-3 at a flow rate of 0.5 L min-1 and 30 min sampling time. A precision (p = 0.95, n = 10) of 7.5% of the overall procedure was achieved at the 100 micrograms m-3 level. Results of laboratory studies concerning the effect of the coating reagent and the relative humidity on the sampling efficiency as well as possible interferences, in particular by ozone, and the elimination of these interferences are discussed. This method was developed to monitor workplace atmospheres as well as ambient air in industrial environments.

Acrylates↗

Surface roughness evaluation of resin modified glass-ionomers polished utilizing poly(acrylic acid) gel.

The differences in polishability of modified and conventional glass-ionomers were studied following different polishing procedures. Specimens of conventional glass-ionomer (Fuji II(R)), resin modified glass-ionomer (Vitremer(R)) and compomer (Dyract(R)) were prepared and polished using either Soflex(R) or Enhance(R) discs with either aluminum oxide or poly(acrylic acid) gel as polishing agents. Surface roughness of the specimens was evaluated by profilometric measurements and electron microscopic examination. It was shown that Soflex(R) discs manifest superior polishing effect on glass-ionomers and resin modified glass-ionomers compared to the Enhance(R) system, although no significant differences were found for the compomer specimens. Addition of poly(acrylic acid) gel as a polishing agent reduced surface roughness of conventional glass-ionomer and resin modified glass-ionomer specimens and did not significantly affect the compomer specimens.

Acrylic Resins↗