Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Wettability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

Effects of scaffold composition and architecture on human nasal chondrocyte redifferentiation and cartilaginous matrix deposition.

We investigated whether the post-expansion redifferentiation and cartilage tissue formation capacity of adult human nasal chondrocytes can be regulated by controlled modifications of scaffold composition and architecture. As a model system, we used poly(ethylene glycol)-terephthalate-poly(butylene)-terephthalate block copolymer scaffolds from two compositions (low or high PEG content, resulting in different wettability) and two architectures (generated by compression molding or three-dimensional (3D) fiber deposition) with similar porosity and mechanical properties, but different interconnecting pore architectures. Scaffolds were seeded with expanded human chondrocytes and the resulting constructs assessed immunohistochemically, biochemically and at the mRNA expression level following up to 4 weeks of static culture. For a given 3D architecture, the more hydrophilic scaffold enhanced cell redifferentiation and cartilaginous tissue formation after 4 weeks culture, as assessed by higher mRNA expression of collagen type II, increased deposition of glycosaminoglycan (GAG) and predominance of type II over type I collagen immunostain. The fiber-deposited scaffolds, with a more accessible pore volume and larger interconnecting pores, supported increased GAG deposition, but only if a more hydrophilic composition was used. By applying controlled and selective modifications of chemico-physical scaffold parameters, we demonstrate that both scaffold composition and architecture are instructive for expanded human chondrocytes in the generation of 3D cartilaginous tissues. The observed effects of composition and architecture were likely to have been mediated, respectively, by differential serum protein adsorption and efficiency of nutrient/waste exchange.

Absorbable Implants↗

Bone tissue engineering on patterned collagen films: an in vitro study.

This study aimed at guiding osteoblast cells from rat bone marrow on chemically modified and patterned collagen films to study the influence of patterns on cell guidance. The films were stabilized using different treatment methods including crosslinking with carbodiimide (EDC) and glutaraldehyde, dehydrothermal treatment (DHT), and deposition of calcium phosphate on the collagen membrane. Mesenchymal osteoprogenitor cells were differentiated into osteoblasts and cultured for 7 and 14 days on micropatterned (groove width: 27 microm, groove depth: 12 microm, ridge width: 2 microm) and macropatterned (groove width: 250 microm, groove depth: 250 microm, ridge width: 100 microm) collagen films to study the influence of pattern dimensions on osteoblast alignment and orientation. Fibrinogen was added to the patterned surfaces as a chemical cue to induce osteoblast adhesion. Cell proliferation on collagen films was determined using MTS assay. Deposition of calcium phosphate on the surface of the film increased surface hydrophilicity and roughness and allowed a good cell proliferation. Combined DHT and EDC treatment provided an intermediate wettability, and also promoted cell proliferation. Glutaraldehyde crosslinking was found to lead to the lowest cell proliferation but fibrinogen adsorption on glutaraldehyde treated film surfaces increased the cell proliferation significantly. Macropatterns were first tested for alignment and only microscopy images were enough to see that there is no specific alignment. As a result of this, micropatterned samples with the topography that affect cell alignment and guidance were used. Osteoblast phenotype expression (ALP activity) was observed to be highest in calcium phosphate deposited samples, emphasizing the effect of mineralization on osteoblast differentiation. In general ALP activity per cell was found to decrease from day 7 to day 14 of incubation. SEM and fluorescence microscopy revealed good osteoblast alignment and orientation along the axis of the patterns when micropatterned films were used. This study shows that it is possible to prepare cell carriers suitable for tissue engineering through choice of appropriate surface topography and surface chemistry. Presence of chemical cues and micropatterns on the surface enhance cell orientation and bone formation.

Animals↗

Procoagulant stimulus processing by the intrinsic pathway of blood plasma coagulation.

Potentiation of the intrinsic pathway of human blood plasma coagulation in vitro by contact with a solid procoagulant surface leads to bolus release of thrombin (FIIa) in concentration proportion to the intensity of activation as measured by procoagulant surface area or energy (water wettability). This rather remarkable finding is confirmed using two different assays: one triggering coagulation substantially through the intrinsic pathway alone and the second triggering coagulation through the intrinsic pathway in the presence of exogenous FIIa spikes. Similarity of experimental outcomes of these assays strongly suggests that endogenous FIIa production through the intrinsic pathway is independent of the absolute amount of FIIa present in plasma. Furthermore, we corroborate previous work indicating that procoagulant surfaces remain activating after repeated use and are not poisoned or denatured in the process of activating plasma coagulation. It is concluded that the sharp control mechanism that gives rise to bolus-production of FIIa from the intrinsic pathway must occur between surface activation of FXII and the FII --> FIIa step, is not related to inhibition by FIIa, and does not involve deactivation of procoagulant surfaces.

Biocompatible Materials↗

Self-curing controlled release systems for steroids. Application of prednisolone-based polymeric systems to ear diseases.

An injectable delivery system for prednisolone has been prepared based on a self-curing formulation comprised of poly(methyl methacrylate) particles and hydroxyethyl methacrylate as monomer. The polymerisation reaction was initiated by the redox system 4,4'-bis (dimethylaminobenzydrol)/benzoyl peroxide (BZN/BPO) and followed at 25 degrees C by measuring the time-temperature profile. A maximum temperature of 53 degrees C and a setting time of 15 min were obtained, calculated according to standard specifications. The swelling of the cured system was studied in phosphate-buffered saline (PBS) at 37 degrees C giving a hydration degree at equilibrium of 20%. The swelling kinetics fitted a fickian behaviour at the initial stages of the experiments, with a diffusion coefficient of 0.72 x 10(-7) cm2/s. The release of the drug was sustained from the beginning without an initial drug burst. The study of the wettability showed a rather hydrophilic character of the surface of the loaded system, and the biocompatibility evaluated through MTT assay revealed the absence of cytotoxicity due to the release of toxic substances.

Animals↗

Cellulose acetate butyrate microcapsules containing dextran ion-exchange resins as self-propelled drug release system.

Sulfopropylated dextran microspheres (SP-Ms), (Dm = 80 microm) loaded with a water soluble drug (Tetracycline HCl), were included in cellulose acetate butyrate (CAB) microcapsules. Spherical CAB microcapsules were obtained by oil in water (o/w) solvent evaporation method in the presence of an inert solvent as cyclohexane (CyH) or n-hexane (N-Hex), and different excipients (Phospholipon, Tween, Span, Eudragit RS 100). Chloroform was found to be the best solvent for the preparation of the microcapsules. Also, the sphericity as well as the porosity of the microcapsules was controlled by the presence of an inert solvent. The final concentration of the drug in CAB microparticles was up to 25% (w/w). The key factors for the successful preparation were also the viscosity of the polymer, while the wettability of the resulted microcapsules, the temperature of the preparation, and the porosity have modulated the release of the drug. The higher is the amount of encapsulated microspheres the thinner is the CAB wall between the compartments created by their incorporation. When these microspheres come in contact with the release medium, the pressure created by their swelling breaks the polymer film and the drug starts to be released. The more drug is released in phosphate buffer the higher is the swelling degree of the encapsulated ion exchange resins and the force created by their supplementary swelling will break the more resistants walls. In this way a self-propelled drug release is achieved, until almost all drug was eliberated.

Anti-Bacterial Agents↗

In vitro bioactivity of MOEP grafted ePTFE membranes for craniofacial applications.

The bioactivity of three methacryloyloxyethyl phosphate (MOEP) grafted expanded polytetrafluoroethylene (ePTFE) membranes with varying surface coverage as well as unmodified ePTFE was investigated through a series of in vitro tests: calcium phosphate (CaP) growth in simulated body fluid (SBF), serum protein adsorption, and a morphology and attachment study of human osteoblast-like SaOS-2 cells. The graft copolymers were prepared by means of gamma irradiation induced grafting and displayed various surface morphologies and wettabilities depending on the grafting conditions used. Unmodified ePTFE did not induce nucleation of CaP minerals, whereas all the grafted membranes revealed the growth of CaP minerals after 7 days immersion in SBF. The sample with lowest surface grafting yield (24% coverage), a smooth graft morphology and relatively high hydrophobicity (theta(adv) = 120 degrees, theta(rec) = 80 degrees) showed carbonated hydroxyapatite growth covering the surface. On the other hand, the samples with high surface grafting yield (76% and 100%), a globular graft morphology and hydrophilic surfaces (theta(adv) = 60 degrees and 80 degrees, theta(rec) = 25 degrees and 15 degrees, respectively) exhibited irregular growth of non-apatitic CaP minerals. Irreversibly adsorbed protein measured after a 1h immersion in serum solution was quantified by the amount of nitrogen on the surface using XPS, as well as by weight increase. All grafted membranes adsorbed 3-6 times more protein than the unmodified membrane. The sample with the highest surface coverage adsorbed the most protein. Osteoblast-like SaOS-2 cells cultured for 3 h revealed significantly higher levels of cell attachment on all grafted membranes compared to unmodified ePTFE. Although the morphology of the cells was heterogeneous, in general, the higher grafted surfaces showed a much better cell morphology than both the low surface-grafted and the control unmodified sample. The suite of in vitro tests confirms that a judicious choice of grafted monomer such as the phosphate-containing methacrylate monomer (MOEP) significantly improves the bioactivity of ePTFE in vitro.

Adsorption↗

Polysaccharide-protein surface modification of titanium via a layer-by-layer technique: characterization and cell behaviour aspects.

To improve the surface biocompatibility of titanium films, a layer-by-layer (LBL) self-assembly technique, based on the polyelectrolyte-mediated electrostatic adsorption of chitosan (Chi) and gelatin (Gel), was used leading to the formation of multilayers on the titanium thin film surfaces. The film growth was initialized by deposition of one layer of positively charged poly(ethylene imine) (PEI). Then the thin film was formed by the alternate deposition of negatively charged Gel and positively charged Chi utilizing electrostatic interactions. The LBL film growth was monitored by several techniques. The chemical composition, surface topography as well as wettability were investigated by using X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), confocal laser scanning microscopy (CLSM) and water contact angle measurement, respectively. Quantitative XPS analysis showed the alternative change of C/N ratio after four sequential cycles coating of Ti/PEI/Gel/Chi/Gel, which indicated the discrete layer structure of coatings. Uncoated titanium (control sample) displayed a smooth surface morphology (root mean square (RMS) roughness was around 2.5 nm). A full coverage of coating with Gel/Chi layers was achieved on the titanium surface only after the deposition layers of PEI/(Gel/Chi)2. The PEI/Gel/(Chi/Gel)3 layer displayed a rough surface morphology with a tree-like structure (RMS roughness is around 82 nm). These results showed that titanium films could be modified with Chi/Gel which may affect the biocompatibility of the modified titanium films. To confirm this hypothesis, cell proliferation and cell viability of osteoblasts on LBL-modified titanium films as well as control samples were investigated in vitro. The proliferation of osteoblasts on modified titanium films was found to be greater than that on control (p<0.05) after 1 and 7 days culture, respectively. Cell viability measurement showed that the Chi/Gel-modified films have higher cell viability (p<0.05) than the control. These data suggest that Chi/Gel were successfully employed to surface engineer titanium via LBL technique, and enhanced its cell biocompatibility. The approach presented here may be exploited for fabrication of titanium-based implant surfaces.

Adsorption↗

Protein bonding on biodegradable poly(L-lactide-co-caprolactone) membrane for esophageal tissue engineering.

A biodegradable and flexible poly(L-lactide-co-caprolactone) (PLLC) copolymer was synthesized and surface modification has been performed aiming at application as a scaffold in esophageal tissue engineering. The PLLC membrane surface was aminolyzed by 1,6-hexanediamine to introduce free amino groups. Using these amino groups as bridges, fibronectin and collagen were subsequently bonded with glutaraldehyde as a coupling agent. The presence of free amino groups on the aminolyzed PLLC surface was quantified using fluorescamine analysis method, which revealed that the surface NH2 density increased and eventually saturated with increasing 1,6-hexanediamine concentration or reaction time. X-ray photoelectron spectroscopy (XPS) confirmed the presence of both proteins separately on the modified PLLC surface. Water contact angle measurements evaluate the wettability of modified and unmodified PLLC surfaces. Protein-bonded surface presented more hydrophilic and homogeneous, yet PLLC can also adsorb some protein molecules. In vitro long-term (12d) culture of porcine esophageal cells proved that fibronectin- and collagen-modified PLLC surface (denoted PLLC-Fn and PLLC-Col, respectively) can more effectively support the growth of smooth muscle cells and epithelial cells; both modified and unmodified PLLC support fibroblasts growth. Mitochondrial activity assay and cell morphology observation indicate that the PLLC-Fn surface is more favorable to epithelium regeneration than PLLC-Col. These culture results provide much valuable information for our subsequent research on the construction of artificial scaffolds with esophageal function. Fibronectin-integrated PLLC will be a good candidate scaffold to support the growth of all types of esophageal cells.

Acetamides↗

Polysulfone-graft-poly(ethylene glycol) graft copolymers for surface modification of polysulfone membranes.

Amphiphilic graft copolymers having polysulfone (PSf) backbones and poly(ethylene glycol) (PEG) side chains were synthesized via reaction of an alkoxide formed from PEG and a base (sodium hydride) with chloromethylated polysulfone. The resulting polysulfone-graft-poly(ethylene glycol), PSf-g-PEG, materials were hydrophilic but water insoluble, rendering them potentially useful as biomaterial coatings. PSf-g-PEG films exhibited high resistance to protein adsorption and cell attachment. When used as an additive in PSf membranes prepared by immersion precipitation, the graft copolymer preferentially segregates to the membrane surface, delivering enhanced wettability, porosity and protein resistance compared to unmodified PSf membranes. The surface properties of PSf-g-PEG modified membranes render them desirable candidates for hemodialysis.

Animals↗

Surface functionalization of degradable polymers by covalent grafting.

With a new non-destructive and solvent-free photografting technique, N-vinylpyrrolidone was covalently grafted onto the surfaces of degradable polymers; poly(l-lactide), poly(epsilon-caprolactone), poly(lactide-co-glycolide), and poly(trimethylene carbonate). The modified surfaces were characterized by XPS, ATR-FTIR, SEM, and cell growth tests. The wettability was markedly improved, as static contact angles changed from about 80 degrees for the pristine substrates to around 30 degrees after 30min of grafting. Well-defined surface topographies, such as micro-patterns, are preserved in the process since the graft layers are thin. The biological response, measured as cytotoxicity, showed that the modified films provide good substrates, comparable with optimized cell culture plastics, for the adhesion and proliferation of normal human keratinocytes and skin fibroblasts.

Biocompatible Materials↗

Evaluation of mammalian cell adhesion on surface-modified porous silicon.

Porous silicon is a promising biomaterial that is non-toxic and biodegradable. Surface modification can offer control over the degradation rate and can also impart properties that promote cell adhesion. In this study, we modified the surface of porous silicon surface by ozone oxidation, silanisation or coating with collagen or serum. For each surface, topography was characterised using atomic force microscopy, wettability by water contact angle measurements, degradation in aqueous buffer by interferometric reflectance spectroscopy and surface chemistry by Fourier-transform infrared spectroscopy. The adhesion of rat pheochromocytoma (PC12) and human lens epithelial cells to these surfaces was investigated. Cells were incubated on the surfaces for 4 and 24 h, and adhesion characteristics were determined by using a fluorescent vital stain and cell counts. Collagen coated and amino silanised porous silicon promoted cell attachment for both cell lines whereas cells attached poorly to ozone oxidised and polyethylene glycol silanised surfaces. We showed that the two cell lines had different adhesion characteristics on the various surfaces at different time points. The use of the vitality assays Alamar Blue (redox based assay) and neutral red (active cellular uptake assay) with porous silicon was also investigated. We reveal incompatibilities between certain resazurin (Alamar Blue), lysosomal incorporation assays (neutral red) and porous silicon.

Animals↗

Volumetric interpretation of protein adsorption: mass and energy balance for albumin adsorption to particulate adsorbents with incrementally increasing hydrophilicity.

The solution-depletion method of measuring human serum albumin (HSA) adsorption to surface-modified glass-particle adsorbents with incrementally increasing hydrophilicity is implemented using SDS gel electrophoresis as a separation and quantification tool. It is shown that adsorbent capacity for albumin measured in interfacial-concentration units (mg/mL) decreases monotonically with increasing surface energy (water wettability) to detection limits near an adsorbent-particle water adhesion tension tau(0)=30 dyne/cm (nominal water contact angle theta=65( composite function)) and that albumin does not adsorb to (concentrate within the surface region of) more hydrophilic adsorbents. These adsorbed-mass measurements corroborate predictions based on interfacial energetics and are consistent with AFM measurement of protein-surface adhesion. Interpretive mass-balance equations are derived from a model premised on the idea that protein reversibly partitions from bulk solution into a three-dimensional (3D) interphase volume separating the physical adsorbent surface from bulk solution. Theory is shown to both anticipate and accommodate experimental results for all test adsorbents, suggesting that the underlying model is descriptive of the essential physical chemistry of albumin adsorption to surfaces spanning the full range of observable water wetting. In particular, application of theory to experimental data shows that the free-energy cost of dehydrating the surface region by protein displacement upon adsorption increases with increasing adsorbent hydrophilicity in a manner that controls ultimate capacity for protein. It is concluded that a simple, three-component free-energy rule adequately describes protein adsorption from aqueous solution, at least for materials bearing varying surface concentrations of anionic (not cationic) functional groups. IMPACT STATEMENT: This work yields detailed insights into the physical chemistry of protein adsorption by elucidating relationships among adsorbent surface energy, capacity to adsorb the protein human serum albumin, and the energy required to displace vicinal water from the interface.

Adsorption↗

Synthesis of two-component injectable polyurethanes for bone tissue engineering.

The advent of injectable polymer technologies has increased the prospect of developing novel, minimally invasive arthroscopic techniques to treat a wide variety of ailments. In this study, we have synthesised and evaluated a novel polyurethane-based injectable, in situ curable, polymer platform to determine its potential uses as a tissue engineered implant. Films of the polymers were prepared by reacting two pentaerythritol-based prepolymers, and characterised for mechanical and surface properties, and cytocompatibility. This polymer platform displayed mechanical strength and elasticity superior to many injectable bone cements and grafts. Cytotoxicity tests using primary human osteoblasts, revealed positive cell viability and increased proliferation over a period of 7 days in culture. This favourable cell environment was attributed to the hydrophilic nature of the films, as assessed by dynamic contact angle (DCA) analysis of the sample surfaces. The incorporation of beta-TCP was shown to improve mechanical properties, surface wettability, and cell viability and proliferation, compared to the other sample types. SEM/EDX analysis of these surfaces also revealed physicochemical surface heterogeneity in the presence of beta-TCP. Based on preliminary mechanical analysis and cytotoxicity results, these injectable polymers may have a number or potential orthopaedic applications; ranging from bone glues to scaffolds for bone regeneration.

Aged↗

The role of independently variable grafting density and layer thickness of polymer nanolayers on peptide adsorption and cell adhesion.

This contribution demonstrates a simple and reproducible method for fabricating surface-tethered polymer brushes that vary in grafting density and layer thickness for peptide adsorption and cell-adhesion studies. Surface-initiated atom transfer radical polymerization was used together with thiol self-assembly to generate these nanothin polymer brush layers of poly((polyethylene glycol) methacrylate). A kinetic study was done to measure the layer thickness growth rate at room temperature from flat gold substrates presenting different polymerization initiator molecule surface densities. The polymer brush layers transition from mushroom to brush regimes with increasing grafting density. A crossover density of 0.038+/-0.005 chains/nm(2) was determined for the PPEGMA polymer brushes. The results described in this paper show that layer properties such as wettability and dry layer thickness depend strongly on initiator surface density. Ultimately, the adsorbed concentration of an RGD-containing synthetic peptide Gly-Arg-Gly-Asp-Ser and the adhesion and spreading of cells were correlated with surface properties, which continues to be a major research theme in biomedical and biomaterials research.

3T3 Cells↗

Improved osteogenic differentiation of human marrow stromal cells cultured on ion-induced chemically structured poly-epsilon-caprolactone.

The ability to control cell proliferation/differentiation, using material surface, is a main goal in tissue engineering. The objective of this study was to evaluate the attachment, proliferation and differentiation to the osteoblastic phenotype of human marrow stromal cells (MSC) when seeded on poly-epsilon-caprolactone (PCL) thin films before and after irradiation with 10 keV He+. The polymeric surface was characterized as surface chemical structure and composition, roughness and morphology on the micro- and nano-scale, wettability and surface free energy parameters. MSC were obtained from patients undergoing routine hip replacement surgery, expanded in vitro and cultured on untreated PCL and He+ irradiated PCL films for up to 4-5 weeks in osteogenic medium. He+-irradiation led to slight smoothening of the surface and different nanoscale surface chemical structure, while surface free energy resulted unchanged in comparison to untreated PCL. The results from biological testing demonstrated that early attachment and further proliferation, as well as osteoblastic markers, were higher for MSC on He+-irradiated PCL. In conclusion, the change of PCL surface properties induced by ion beam irradiation is confirmed to enhance the adhesion of MSC and support their differentiation.

Biocompatible Materials↗

Organic plasma process for simple and substrate-independent surface modification of polymeric BioMEMS devices.

A polymeric bio micro electromechanical systems (BioMEMS) device was fabricated using organic plasma polymerization, by which the surface of a polymeric substrate could easily be modified through vapor-phase deposition of organic thin films. This technique, capable of polymeric deposition of any kind of monomer, can serve the purpose of anti-fouling coating, wettability control, or layer-to-layer interface creation, on the surface of any given chemically-inert polymeric substrate without involving cumbersome surface organic reactions. A prototype device was fabricated to have an array of electrochemical glucose biosensors with the three electrode configuration, each of which has a microfluidic channel (500 microm x 800 microm) for capillary-action-driven sample delivery and the concerned enzymatic reaction. Stressing the advantages of the plasma polymerization process using a polymeric substrate together with some additional features accomplished in our device fabrication, new possibilities in the field of polymeric BioMEMS are discussed.

Biosensing Techniques↗

Assessment of porous silicon substrate for well-characterised sensitive DNA chip implement.

A biochip approach based on porous silicon as substrate is presented. The goal is to enhance the sensitivity of the biochip by increasing the specific surface area on the support. The elaboration of porous silicon layers has been optimized to guarantee good accessibility for large bio-molecule targets. Oligonucleotide probes are synthesised directly on the surface using phosphoramidite chemistry. The high specific surface area of porous silicon allows the direct characterisation, by infrared spectroscopy, of the porous layer formation and the functionalisation steps. The monolayer grafting and derivatisation protocol is additionally characterized by wettability and fluorescence microscopy. The surface modification of porous layers (i.e. thermal oxidation and chemical derivatisation) ensures the stability of the structure against strong chemical reagents used during the direct oligonucleotide synthesis. Finally the protocol is successfully transferred to a flat Si/SiO(2) substrate, and validated by biological target specific recognition during hybridisation tests. In particular, radioactive measurements show a 10-fold enhancement of the oligonucleotide surface density on the porous silicon substrate compared to the flat thermal silica.

Crystallization↗

Electron transfer mediator micro-biosensor fabrication by organic plasma process.

We propose a new strategy for constructing a mediator-type biosensor as a Bio-MicroElectroMechanical Systems (BioMEMS) application. A vinylferrocene plasma-polymerized film (PPF) was deposited directly onto the surface of an electrode under dry conditions. The resulting redox film was extremely thin, adhered well onto a substrate (electrode), and had a highly crosslinked network structure. This technique, capable of polymeric deposition of any kind of monomer, can also serve the purpose of anti-fouling coating, or layer-to-layer interface creation. With a subsequent plasma process, additional polymeric layer of hydrophilic acetonitrile was superimposed onto the existing vinylferrocene-PPF surface to offer crucial features such that the wettability could be adjusted for a better electron transfer, and amino functional groups could be attached to immobilize a large amount of enzyme. Based upon this scheme, the device fabrication could be designed in a manner that the whole procedure was made up of dry wafer-handling processes, which is compatible with mass production. A prototype device was fabricated to have an array of needle-shaped amperometric micro-biosensors. The resultant thin polymer layer carried a large number of the mediator molecules, accomplishing a lower overpotential (+410 mV) and a rapid response time (<5s). Stressing the advantages of the plasma polymerization process together with some additional features accomplished in our device fabrication, we would discuss new possibilities in the field of BioMEMS.

Biosensing Techniques↗