Evaluation and assessment of new disposable strip for determination of plasma potassium concentration.

Overall laboratory reproducibility for the Ames Seralyzer and plasma potassium test strips was less than 4% within the plasma reference range; and linearity extended from 2.1 to 10.2 mmol/l. Neither bilirubin nor lipaemia interfered in the analysis and selectivity for potassium over sodium was 450:1. Laboratory comparison with automated flame photometry and an indirect ion selective electrode showed a Seralyzer bias of +0.10 (+/- 25D 0.26) and +0.11 (0.27) mmol/l. Against flame photometry, comparison of analyses by six doctors from a coronary care unit and four nurses from a renal dialysis unit showed smaller positive biases (0.06 and 0.02 mmol/l) but substantially larger error ranges (0.43 and 0.55 mmol/l, respectively). Some 49% of the nurses' and 37% of the doctors' results differed from laboratory values by more than 0.2 mmol/l. Potassium test strip results proved acceptably comparable and reproducible when produced by an experienced analyst, but greater variability in clinical hands rendered the system unsuitable for precise monitoring of potassium concentration.

Humans↗

High dose brain CT with ioxaglate and diatrizoate adverse reactions and effects on urine protein tests.

Sodium meglumine ioxaglate (320 or 306 mg I/ml) and meglumine diatrizoate (306 mg I/ml) in an intravenous dose of 2 ml/kg were compared in a randomized double-blind test on the brain CT of 209 patients. Side effects were noted in 56% of the ioxaglate group and 90% of the diatrizoate group. Diatrizoate caused a sensation of heat significantly more often and more intensely, but the frequencies of other side effects did not differ significantly. No severe reactions occurred. The quality of the CT scans was equal. Neither ioxaglate nor diatrizoate impaired renal function. False-positive strip tests and falsely elevated protein values measured by the biuretic method were found in particular in the ioxaglate group. The results of urine protein measurements and strip tests are misleading on the day of the examination with both ioxaglate and diatrizoate.

Adult↗

Home monitoring of blood glucose without a photometer.

The ability to estimate blood glucose values at home is an important way of improving diabetic control. In order to investigate whether it was possible to replace the photometers used at present colour discrimination of ReflotestR-Glucose and ReflotestR-Hypoglycemie strips are studied. It was found that a colour scale could be used with one discrete shade of colour for each millimol between 1 to 20 millimol/l. A new test strip Haemo-GlukotestR 20-800 for colour scale usage was tested. Correlation with hexokinase method as reference was found to be r = 0.97.

Blood Glucose↗

Test strip meconium screening for cystic fibrosis.

The Boehringer-Mannheim Corporation (BMC) strip test is extremely reliable in indicating an albumin content above 20 mg/gm of dried meconium. All infants born during one year in 14 Milwaukee area hospitals were tested. Of 16,224 newborns, two were diagnosed correctly as suffering from cystic fibrosis and two were missed. False-positive tests were obtained in 0.9% of infants (prematurity, melena, gastroschisis, and intrauterine infection). The strip test is, at present, the best available but not the perfect screening method for cystic fibrosis.

Albumins↗

Detection of postoperative pancreatitis after pancreatic surgery by urine trypsinogen strip test.

BACKGROUND: The urine trypsinogen strip test has been used successfully in the diagnosis of pancreatitis of various aetiologies, but has not been studied in postoperative pancreatitis. The aim of this study was to evaluate this test for the diagnosis of postoperative pancreatitis after pancreatic resection. METHODS: Fifty patients undergoing pancreatic resection were included. The urine trypsinogen strip test was done daily during the first postoperative week, blood was analysed before and 4, 6 and 10 days after surgery, and amylase activity in the drainage fluid was measured on days 4 and 6. Patients underwent computed tomography (CT) before operation and on days 2 and 6 afterwards. RESULTS: Thirteen patients (26 per cent) developed CT-detected pancreatitis after operation. In 12 of these patients pancreatitis was detected on the second postoperative day. The urine trypsinogen test was positive in all 13 patients with postoperative pancreatitis, and was already positive on the first day after surgery in 12. The sensitivity, specificity, and positive and negative predictive values of the trypsinogen strip test in detection of postoperative pancreatitis were 100, 92, 81 and 100 per cent respectively. In receiver-operator characteristic analysis the area under the curve (AUC) was higher for the urine trypsinogen strip test (AUC 0.959) than for a serum amylase level more than two (AUC 0.731) or three times (AUC 0.654) above the upper normal range in the diagnosis of postoperative pancreatitis. Patients whose recovery was complicated by pancreatic fistula, detected by drain output measurements on day 6, more often had a positive urine trypsinogen test than patients without a fistula (11 of 12 versus five of 38; P < 0.001). CONCLUSION: This study suggests that the urine trypsinogen strip test might be a valuable method for diagnosis of pancreatitis after pancreatic surgery.

Adolescent↗

MalaQuick versus ParaSight F as a diagnostic aid in travellers' malaria.

In this study we assessed whether travellers can perform malaria rapid tests, following the provided information leaflet, and correctly interpret performed and pre-prepared test strips. Two Plasmodium falciparum testing systems, namely MalaQuick (ICT) and ParaSight F were used. Test performance and test interpretation of pre-prepared tests were compared. There was no significant difference in test performance between the 2 tests. Interpretation of prepared test strips in both test systems was very reliable in blood parasite densities between 0.1% and 2%, but major problems were encountered at low parasitaemia (< 0.1% blood parasites) and also in ParaSight F test strips showing high parasitaemia (> 2% blood parasites). Low parasitaemia ParaSight F test strips were correctly interpreted by 52.1% compared with 10.8% correct interpretations with MalaQuick (P < 0.0001). Correct interpretation of highly positive (> 2% blood parasites) pre-prepared test strips was higher with MalaQuick (96.8%) than with ParaSight F (33.8%), P < 0.0001. Both tests were associated with high levels of false-negative interpretations which render them unsuitable as self-diagnostic kits. Efforts must be made to assist lay individuals in test performance by technical test improvement, by equiping the test strips with an additional reading aid for interpretation, and by providing instruction by a skilled person.

Adult↗

Evaluation of Diabur-Test 5000: a cooperative study carried out at 12 diabetes centers.

Diabur-Test 5000, a new test strip for urinary glucose, permits the accurate measurement of up to 5% glucose concentrations in urine. In a survey carried out at 12 diabetes centers in Europe, the new test strip was tested in laboratory trials and routine self-monitoring. There was good agreement between the test strip and the quantitative glucose determination on 4105 urine samples in the laboratory trials. A total of 185 patients used Diabur-Test 5000 for self-monitoring; nearly all reported favorably on the new test strip. Both the laboratory tests (on 1677 urine samples) and self-monitoring (on 4309 urine samples) showed Diabur-Test 5000 to be more sensitive compared with other rapid diagnostic tests. The new test strip is highly suitable for the determination of urinary glucose, particularly in routine self-monitoring.

Clinical Trials as Topic↗

[EXAFS study on the stripping mechanism in N263/alkaline cyanide gold solution/sulfuric thiourea system].

Quaternary ammonium salt has strong affinity with gold in cyanide solutions, but it is not readily stripped. Stripping with acidic thiourea solutions and air sparging shows promise. There are some reports on the process of thiourea stripping, but little about its mechanism. In this paper, the stripping mechanism of N263/sulphuric thiourea/alkaline cyanide gold solution is studied by EXAFS. According to the experiments, sulphuric acid, thiourea and gold-thiourea complex can be extracted by N263 as a neutral molecule, and the stripping process can be described as following: (1) Sulphuric acid and thiourea are extracted by N263; (2) In organic phase, gold-cyanide complex is converted to gold-thiourea complex, which exists as Au[SC(NH2)2]2HSO4, and CN- forms HCN with acid at the same time; (3) HCN is removed by air sparging, and Au[SC(NH2)2]2HSO4 is distributed between organic phase and liquor phase, most of which transfers to liquor phase and is stripped.

Amines↗

[A new test-strip for checking blood-sugar levels].

Blood sugar levels in 228 EDTA-treated venous blood samples were measured in the laboratory by a new test-strip (Visidex) and the hexokinase reference method. There was good agreement between the two, with a linear correlation of r = 0.92 and a regression line with a slope of 0.98. 97.8% of all values deviated by less than one concentration range from the reference values. At low glucose concentrations the median of the absolute differences between the two methods was 9.5 mg/dl. Over the whole concentration range of 20-800 mg/dl the mean deviation from the reference values was between 14.4 and 32.6 mg/dl. The results indicate that the Visidex test-strip method is suitable for the visual estimation of blood sugar values.

Blood Glucose↗

Measurement of urinary lactoferrin as a marker of urinary tract infection.

The usefulness of the measurement of urinary lactoferrin (LF) released from polymorphonuclear leukocytes and of an immunochromatography test strip devised for measuring urinary LF for the simple and rapid diagnosis of urinary tract infections (UTI) was evaluated. Urine specimens were collected from apparently healthy persons and patients diagnosed as suffering from UTI. In the preliminary study, the LF concentrations in 121 normal specimens and 88 specimens from patients (60 with UTI) were quantified by an enzyme-linked immunosorbent assay. The LF concentration was 3,300.0 +/- 646.3 ng/ml (average +/- standard error of the mean) in the specimens from UTI patients, whereas it was 30.4 +/- 2.7 ng/ml and 60.3 +/- 14.9 ng/ml in the specimens from healthy persons and the patients without UTI, respectively. Based on these results, a 200-ng/ml LF concentration was chosen as the cutoff value for negativity. Each urine specimen was reexamined with the newly devised immunochromatography (IC) test strip to calculate the indices of efficacy. Based on the cutoff value, it was calculated that the sensitivity, specificity, and positive and negative predictive values of the IC test were 93.3, 89.3, 86.2, and 94.9%, respectively, compared with the results of the microscopic examination of the urine specimens for the presence of leukocytes. The respective indices for UTI were calculated as 95.0, 92.9, 89.7, and 96.6%. The tests were completed within 10 min. These results indicated that urine LF measurement with the IC test strip provides a useful tool for the simple and rapid diagnosis of UTI.

Adult↗

Leucocyte esterase-nitrite screening method for pyuria and bacteriuria.

The value of the one minute leucocyte esterase-nitrite chemical strips as a screening procedure for detecting appreciable levels of pyuria and bacteriuria was assessed by comparison with microscopy and culture results. The likelihood that a negative leucocyte esterase result indicated less than 10 white cells/cu mm by microscopy (the negative predictive value), was 90.1% and that a negative nitrite result indicated less than 10(5) organisms/ml was 91.3%. There were many false positive results with both tests, however, and the overall predictive value of a positive leucocyte esterase or nitrite test, or both, was low. The leucocyte esterase-nitrite strip was neither sufficiently sensitive nor specific enough to be used as a cost effective method for screening urines in the laboratory.

Bacteriuria↗

[Comparison of 2 semi-quantitative methods for evaluating blood glucose in newborn infants].

Blood glucose levels were assessed in 49 neonates, using 2 blood glucose test strips. Results were compared to blood glucose levels. Correlations between values from the test strips and values from the laboratory were better using the Haemo-Glukotest (r = 0.91) than using the Dextrostix (r = 0.82). As compared to values from the laboratory, however, both glucose test strips gave higher values and did not properly identify all cases of hypoglycemia.

Blood Glucose↗

Schirmer's test of lacrimation.

Schirmer's test is a simple, semiquantitative test of tear production. It is based on the physical tendency of a fluid to travel along a strip of porous material by capillary action due to surface tension. Sterile strips, standardized and prepackaged, are available from local scientific supply houses. The low cost and simplicity of this test make it useful in confirming the diagnosis of diseases involving decreased lacrimal secretion.

Humans↗

Home urine cultures by the dip-strip method: results in 289 cultures.

Bacteriuria screening on 289 children was performed by their parents by means of a self-administered dip-strip culture which was inoculated, incubated, and interpreted in the home. Simultaneous pour-plate quantitative cultures and laboratory-tested dip-strip cultures were done on the same urine specimen which had been tested at home. The dip-strip culture was reliable (89%) in detecting significant bacteriuria with home administration and interpretation. Only 1.6% false-positive results occurred in the home testing. The dip-strip home cultures are an effective way for screening or follow-up of patients with bacteriuria.

Bacteriuria↗

[The long-term stability of reactive strips for capillary blood glucose preserved at between 2 and 5 degrees C].

OBJECTIVE: To assess the stability of the reactive strips for capillary glycemia, preserved between 2 and 5 degrees C, and at ambient temperature, during 8 weeks. DESIGN: Transversal descriptive study. SETTING: Health Center "V Centenario" of San Sebastián de los Reyes. PATIENTS AND OTHER PARTICIPANTS: 322 strips were obtained, 31 were underrated because they could not read the orderly days, of the 291 remaining, 159 were kept in the refrigerator between 2 and 5 degrees C, and 132 were kept at ambient temperature, preserved to the light. MEASUREMENTS AND MAIN RESULTS: All the strips were type "BM-test-glycemia 24 hours, and the weeks 1 to 8. At ambient temperature the strips lose the 5% of their basal value, and the 23 and 32% in the first and second weeks respectively (p < 0.001). The strips kept in refrigerator have a rise at 24 hours, with regard to basal value of 7% (p < 0.001). Starting from this moment, a gradual fall of the mean value of the glycemia is produced, significant differences were not found in the second week. After 8 weeks, a mean loss of 10% of the strip value is noticed. CONCLUSIONS: The fall of the strip value, preserved in refrigerator is not clinically very important, an acceptable control of the diabetic patient can be obtained by delayed reading, even 8 weeks, of reactive strips that patients can keep in their refrigerators.

Blood Glucose↗

Effect of meibomian oils on Schirmer tear test.

The detrimental effect of meibomian oils expressed onto the lid margins on the value of the Schirmer test was investigated in two studies (N = 12 per study): without and with topical anaesthesia. In the 12 subjects studied there was no evidence of external ocular disease. The studies were conducted in a double masked randomised cross-over fashion. It was found that neither expression of meibomian oils nor topical anaesthesia showed any statistically significant (P greater than 0.05) reduction in final tear secretion rates. Thus, the notions that lid manipulation may impede tear flow into the Schirmer strip and that topical anaesthesia reduces apparent tear flow, are not supported.

Adult↗

Quantitative evaluation of urinalysis test strips.

BACKGROUND: Urine test strip results are generally reported in categories (i.e., ordinal scaled), but automated strip readers are now available that can report quantitative data. We investigated the possible use of these meters to complement flow cytometry of urine and compared reflectance readings with quantitative determinations of urinary glucose and microalbumin. METHODS: We compared URISYS 2400 (Roche) quantitative reflectance data with data from the UF-100 (Sysmex) and biochemical data for 436 nonpathologic and pathologic urine samples. RESULTS: Reproducibility of the reflectance signal was good for high- and low-concentration urine pools for protein (0.8% and 0.9% and 1.5% and 2.2% within and between runs, respectively), leukocyte esterase (1.1% and 1.0%; 5.1% and 1.2%), hemoglobin (1.7% and 1.1%; 8.9% and 1.1%) and glucose (2.1% and 0.5%; 6.5% and 2.3%). Fair agreement was obtained between UF-100 and test strip reflectance data for erythrocytes and hemoglobin (r = -0.680) and leukocytes and leukocyte esterase (r = -0.688). Higher correlations were observed for biochemical and test strip data comparing protein and albumin (r = -0.825) and glucose data (r = -0.851). The lower limits of detection for erythrocytes and leukocytes were 8 x 10(6)/L and 19 x 10(6)/L, respectively. The protein test (n = 220) detected 86% (95% confidence interval, 78-92%) of samples with <30 mg/L albumin with a specificity of 84% (95% confidence interval, 76-91%). CONCLUSIONS: In urine test strip analysis, quantitative hemoglobin and leukocyte esterase reflectance data are complementary with flow cytometric results and glucose and albumin results.

Albumins↗

[Usefulness of reactive strips in the diagnosis of suppurative meningitis, at the patient's bedside].

The CSF from 68 children suspected of meningitis (20 meningitis, 48 normal) was analyzed with the customary laboratory techniques (cellularity, differential count, glucose, proteins and bacteriology) and with Combur 9 test strips (glucose, proteins and leukocytes-granulocytes) in order to evaluate the suitability of the latter for the rapid diagnosis of meningitis.

Cerebrospinal Fluid Proteins↗