Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIO”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

Analysing radio-frequency coil arrays in high-field magnetic resonance imaging by the combined field integral equation method.

We present the combined field integral equation (CFIE) method for analysing radio-frequency coil arrays in high-field magnetic resonance imaging (MRI). Three-dimensional models of coils and the human body were used to take into account the electromagnetic coupling. In the method of moments formulation, we applied triangular patches and the Rao-Wilton-Glisson basis functions to model arbitrarily shaped geometries. We first examined a rectangular loop coil to verify the CFIE method and also demonstrate its efficiency and accuracy. We then studied several eight-channel receive-only head coil arrays for 7.0 T SENSE functional MRI. Numerical results show that the signal dropout and the average SNR are two major concerns in SENSE coil array design. A good design should be a balance of these two factors.

Algorithms↗

Public exposure to radio waves near GSM microcell and picocell base stations.

Exposures of the general public to radio waves at locations near 20 randomly selected GSM microcell and picocell base stations in the UK have been assessed in the context of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Compliance distances were calculated for the antennas of the base stations from their reported radiated powers. Under pessimistic assumptions that would maximise exposures, the minimum height at which the general public reference level could potentially be exceeded near any of the base station antennas was calculated to be 2.4 m above ground level. The power densities of the broadcast carriers transmitted by the base stations have been measured and scaled to include all other possible carriers. Exposures were generally in the range 0.002-2% of the ICNIRP general public reference level, and the greatest exposure quotient near any of the base stations was 8.6%. Exposures close to microcell base stations were found to be generally greater than those close to macrocell base stations.

Cell Phone↗

Occupational exposure to radio frequency/microwave radiation and the risk of brain tumors: Interphone Study Group, Germany.

It is still under debate whether occupational exposure to radio frequency/microwave electromagnetic fields (RF/MW-EMF) contributes to the development of brain tumors. This analysis examined the role of occupational RF/MW-EMF exposure in the risk of glioma and meningioma. A population-based, case-control study including 381 meningioma cases, 366 glioma cases, and 1,494 controls aged 30-69 years was performed in three German regions in 2000-2003. An exposure matrix for occupational activity was constructed by using information on RF/MW-EMF exposure collected in a computer-assisted personal interview. "High" exposure was defined as an occupational exposure that may exceed the RF/MW-EMF exposure limits for the general public recommended by the International Commission on Non-Ionizing Radiation Protection. Multiple conditional logistic regressions were performed separately for glioma and meningioma. No significant association between occupational exposure to RF/MW-EMF and brain tumors was found. For glioma, the adjusted odds ratio for highly exposed persons compared with persons not highly exposed was 1.21 (95% confidence interval: 0.69, 2.13); for meningioma, it was 1.34 (95% confidence interval: 0.64, 2.81). However, the slight increase in risk observed with increasing duration of exposure merits further research with larger sample sizes.

Adult↗

Cancer incidence near radio and television transmitters in Great Britain. II. All high power transmitters.

A small area study of cancer incidence, 1974-1986, near 20 high power television (TV) and frequency modulation (FM) radio transmitters in Great Britain was carried out to place in context the findings of an earlier study around the Sutton Coldfield transmitter. The national database of postcoded cancer registrations was used with population and socioeconomic data from the 1981 census. Cancers examined were adult leukemias, skin melanoma, and bladder cancer, following the findings in the earlier study of significant declines in risk of these cancers with distance from the Sutton Coldfield transmitter. Childhood leukemia and brain cancer were also examined. Statistical analysis was performed for all transmitters combined, four overlapping groups of transmitters defined by their transmission characteristics, and for all transmitters separately. There were 3,305 adult leukemia cases from 0-10 km (observed/expected (O/E) ratio = 1.03, 95% confidence interval (CI) 1.00-1.07). A decline in risk of adult leukemia was found for all transmitters combined (p = 0.05), two of the transmitter groups, and three of the single transmitters; for all transmitters combined, observed excess risk was no more than 15% at any distance up to 10 km, and there was no observed excess within 2 km of transmitters (O/E ratio = 0.97, 95% CI 0.78-1.21). For childhood leukemia and brain cancer, and adult skin melanoma and bladder cancer, results were not indicative of a decline in risk with distance from transmitters. The magnitude and pattern of risk found in the Sutton Coldfield study did not appear to be replicated. The authors conclude that the results at most give no more than very weak support to the Sutton Coldfield findings.

Adolescent↗

Miscarriages among female physical therapists who report using radio- and microwave-frequency electromagnetic radiation.

Physical therapists are exposed to radio- and microwave-frequency electromagnetic radiation by operating shortwave and microwave diathermy units. Recent studies suggest that use of shortwave diathermy is associated with an excess risk of birth defects, perinatal deaths, and late spontaneous abortions among the offspring of exposed female therapists. To assess the impact of occupational use of microwave and shortwave diathermy at the time of conception, the authors mailed questionnaires to 42,403 physical therapists in 1989. Both occupational and reproductive histories were obtained. Exposures to shortwave and microwave diathermy were both assessed in the same fashion and were examined in relation to early recognized fetal loss in a nested case-control design. A total of 1,753 case pregnancies (miscarriages) were matched to 1,753 incidence density control pregnancies (other pregnancies except ectopic pregnancies). A pregnancy was considered "exposed" if the mother reported using microwave or shortwave diathermy anytime during the 6 months prior to the first trimester or during the first trimester. Pregnancies of mothers reporting microwave use 6 months prior to the pregnancy or during the first trimester were more likely to result in miscarriage (odds ratio (OR) = 1.28, 95% confidence interval (CI) 1.02-1.59). The odds ratio increased with increasing level of exposure (chi 2 = 7.25, p < 0.005). The odds ratio in the highest exposure group (20 or more exposures/month) was 1.59. The overall odds ratio was slightly lower after it was controlled for prior fetal loss (OR = 1.26, 95% CI 1.00-1.59), but the exposure-response effect remained (chi 2 = 5.17, p < 0.01). The risk of miscarriage was not associated with reported use of shortwave diathermy equipment (OR = 1.07, 95% CI 0.91-1.24). The odds ratio in the highest exposure group was 0.87.

Abortion, Spontaneous↗

Failure of chronic exposure to nonthermal FM radio waves to mutate Drosophila.

A stock of Drosophila sc VI - YS/y ac oc ptg - YL/y ac oc ptg - YL/y sc S1 B In49 ct ns v sc8 that accumulated the recessive lethals on the X chromosome was exposed to a frequency of 98.5 MHz (wave length 3.35 m) and a field strength of 0.3 V/m. The flies were kept near the base of the 300-ft antenna of a 50,000 watt transmitter for 32 weeks. There was no significant difference in the percentage of lethals between the stock exposed to 4,020 hours of nonthermal FM radio waves and the controls.

Animals↗

Ray-tracing techniques to assess the electromagnetic field radiated by radio base stations: application and experimental validation in an urban environment.

This paper aims to validate a ray-tracing model for electromagnetic field calculation, which is used in urban environments to predict irradiation from radio base stations for population exposure evaluation. Validation was carried out through a measurement campaign by choosing measurement points in order to test different propagation environments and analysing broadcast control channels through narrow band measurements. Comparison of the calculated and measured fields indicates that the ray-tracing model used calculates electric field with good accuracy, in spite of the fact that the propagation environment is not described in detail, because of difficulties in modelling the geometrical and electrical characteristics of urban areas. Differences between the calculated and measured results remain below 1.5 dB, with a mean value of 1 dB.

Algorithms↗

Radio frequency radiation of millimeter wave length: potential occupational safety issues relating to surface heating.

Currently, technology is being developed that makes use of the millimeter wave (MMW) range (30-300 GHz) of the radio frequency region of the electromagnetic spectrum. As more and more systems come on line and are used in everyday applications, the possibility of inadvertent exposure of personnel to MMWs increases. To date, there has been no published discussion regarding the health effects of MMWs; this review attempts to fill that void. Because of the shallow depth of penetration, the energy and, therefore, heat associated with MMWs will be deposited within the first 1-2 mm of human skin. MMWs have been used in states of the former Soviet Union to provide therapeutic benefit in a number of diverse disease states, including skin disorders, gastric ulcers, heart disease and cancer. Conversely, the possibility exists that hazards might be associated with accidental overexposure to MMWs. This review attempts to critically analyze the likelihood of such acute effects as burn and eye damage, as well as potential long-term effects, including cancer.

Accidents, Occupational↗

A quantitative study of ramped radio frequency, magnetization transfer, and slab thickness in three-dimensional time-of-flight magnetic resonance angiography in a patient population.

RATIONALE AND OBJECTIVES: The authors compare the effectiveness of various magnetic resonance (MR) angiography acquisition strategies in enhancing the visibility of small intracranial vessels. METHODS: Blood vessel contrast-to-noise ratio (CNR) in time-of-flight MR angiography was studied as a function of vessel size and several selectable imaging parameters. Contrast-to-noise measurements were made on 257 vessel segments ranging in size from 0.3 mm to 4.2 mm in patients who recently had undergone intraarterial cerebral angiography. Imaging parameters studied included magnetization transfer, spatially variable radio frequency (RF) pulse profile (ramped RF), and imaging slab thickness. RESULTS: The combination of thin slabs (16 slices/slab), ramped RF, and magnetization transfer resulted in the highest CNR for all but the smallest vessel sizes. The smallest vessels (< 0.5 mm) had the highest CNR, using the thick slab (64 slices/slab) with ramped RF and magnetization transfer. Magnetization transfer always improved vessel CNR, but the improvement diminished as the slab thickness was reduced. The CNR increased with a decrease in slab thickness for all but the smallest vessel sizes. CONCLUSIONS: Overall, the results provide a quantitative demonstration that inflow enhancement of blood is reduced for small vessels. Thus, whereas magnetization transfer is important at all vessel sizes, it becomes the primary factor in improving the visibility of the smallest vessels.

Adult↗

Observation by MR imaging of in vivo temperature changes induced by radio frequency hyperthermia.

Volunteers have undergone radio frequency hyperthermia in a magnetic resonance (MR) imaging system to investigate which of several possible MR parameters would be most convenient and sensitive to use to observe in vivo temperature changes. Measurements were made for T1, T2, and perfusion and diffusion variations, although the number of sequences needed at each temperature meant that the number of data points obtainable was limited. However, in the temperature range studied (around 28-42 degrees C), changes in both T1 and the diffusion coefficient were observed that agreed quite well with those predicted theoretically (respectively around 1.3%/degrees C and 2.4/degrees C).

Body Temperature↗

Evaluation of health risks caused by radio frequency accelerated carcinogenesis: the importance of processes driven by the calcium ion signal.

The acceleration of carcinogenesis, which was induced either by radio frequency radiation from a cellular telephone or by the ferric-ATP complex, was similar in a mouse strain characterized by age-determined carcinogenesis of lymphoid tissues. Organ hypertrophy, the presence of lymphoid blood and ascites, the development of solid tumours, and mortality were very different to those found in control animals. These results emphasize the role of calcium ion signal influx in the activation of oncogenes and the failure of thymus-determined immune defences.

Adenoma↗

Laparoscopic partial nephrectomy of solid renal masses without hilar clamping using a monopolar radio frequency device.

PURPOSE: Partial nephrectomy is currently recommended for most amenable solid renal tumors, especially if they are exophytic and less than 4 cm. We reviewed our initial experience with laparoscopic partial nephrectomy for solid renal masses without clamping the renal vasculature using a monopolar device that uses radio frequency energy with low volume saline irrigation for simultaneous blunt dissection, hemostatic sealing and coagulation of the renal parenchyma (TissueLink, TissueLink Medical, Inc., Dover, New Hampshire). MATERIALS AND METHODS: From September 2002 to April 2003, 10 patients underwent transperitoneal laparoscopic partial nephrectomy, including 9 with solid renal masses and 1 with a complex cyst. In all cases the renal hilum was dissected and the renal vessels were isolated but none had renal vascular clamping. The TissueLink DS dissecting sealer or Floating Ball (TissueLink Medical, Inc.) was used to dissect the tumor free bluntly, while simultaneously sealing and coagulating bleeders. RESULTS: Mean patient age was 54.6 years (range 42 to 72). Mean American Society of Anesthesiologists score was 2.3 (range 2 to 4). Mean tumor size was 3.9 cm (range 2.1 to 8). The mass had a peripheral location in 7 cases and a central location in 3. Mean operative time was 232 minutes (range 144 to 280) and mean blood loss was 352 ml (range 20 to 1000). One patient received blood transfusion and all tumor margins were negative. Mean hospital stay was 1.7 days (range 1 to 5) and pain medication use was minimal. One patient had a brief period of urine leakage from the lower pole calix, which was managed successfully by ureteral stenting and Foley catheter drainage of the bladder. CONCLUSIONS: Laparoscopic partial nephrectomy can be performed without renal vascular clamping. TissueLink technology allows complete tumor resection and provides adequate parenchymal hemostasis of the tumor bed. Its scant tissue charring production does not interfere with the pathological assessment of the tumor margin status.

Adult↗

Indium-111-labelled donor-lymphocyte infusion by way of hepatic artery and radio-frequency ablation against liver metastases of renal and colon carcinoma after allogeneic hematopoietic stem-cell transplantation.

BACKGROUND: In patients with metastatic solid cancer, antitumor effects occur after allogeneic stem-cell transplantation (SCT). However, this treatment is not as effective in the liver as against pulmonary and lymph-node metastases. To intensify the effect of donor-lymphocyte infusions (DLI) against liver metastases, intra-arterial (IA) cell injection by way of the hepatic artery (HA) can be used. METHODS: To trace infused cells, three patients with colorectal, three with renal, and one with breast carcinoma were treated with Indium-111 (111-In)-oxinate-labeled lymphocytes. Four patients received the DLI IA, all after radio-frequency ablation (RFA) of liver metastases. Three patients with other metastases received 111-In DLI intravenously (IV). One of them had RFA before SCT. RESULTS: Localization of the IA 111-In DLI activity on scintigrams homed to the liver. After IA injection, the liver to sternum ratio of radioactivity was higher compared with IV injection. Cells (CD3+, 19+, and 56+) of donor origin in biopsies of liver metastasis in two patients treated with IA injection increased to 80% to 100%. Two of four patients treated using the IA DLI showed stable size and number of liver metastases for 5 and 21 months, respectively. Both are alive 18 and 34 months after SCT. Two of three patients receiving DLI IV are doing well, with a stable metastatic disease or still without metastases 21 and 20 months after cell infusions (26 and 34 months after SCT), respectively. Three patients died because of progressive disease. CONCLUSION: When infused by way of the HA, 111-In-labeled lymphocytes home to the liver and its metastases. The liver metastasis infiltrating cells of donor origin increased. DLI by way of the HA combined with RFA may be used to treat liver metastases after SCT.

Adult↗

Elimination of transmissible spongiform encephalopathy infectivity and decontamination of surgical instruments by using radio-frequency gas-plasma treatment.

It has now been established that transmissible spongiform encephalopathy (TSE) infectivity, which is highly resistant to conventional methods of deactivation, can be transmitted iatrogenically by contaminated stainless steel. It is important that new methods are evaluated for effective removal of protein residues from surgical instruments. Here, radio-frequency (RF) gas-plasma treatment was investigated as a method of removing both the protein debris and TSE infectivity. Stainless-steel spheres contaminated with the 263K strain of scrapie and a variety of used surgical instruments, which had been cleaned by a hospital sterile-services department, were examined both before and after treatment by RF gas plasma, using scanning electron microscopy and energy-dispersive X-ray spectroscopic analysis. Transmission of scrapie from the contaminated spheres was examined in hamsters by the peripheral route of infection. RF gas-plasma treatment effectively removed residual organic residues on reprocessed surgical instruments and gross contamination both from orthopaedic blades and from the experimentally contaminated spheres. In vivo testing showed that RF gas-plasma treatment of scrapie-infected spheres eliminated transmission of infectivity. The infectivity of the TSE agent adsorbed on metal spheres could be removed effectively by gas-plasma cleaning with argon/oxygen mixtures. This treatment can effectively remove 'stubborn' residual contamination on surgical instruments.

Animals↗

Evaluation of microwave and radio frequency catheter ablation in a myocardium-equivalent phantom model.

A highly localized burst of energy applied to the myocardium via a transvenous catheter-mounted power source can be used to destroy endocardial tissue regions which mediate life-threatening arrhythmias. In the past, high-voltage direct current pulses, radio-frequency (RF) current, and laser light have been used as energy sources. In this paper, the use of 2450 MHz microwave energy applied via a miniature coaxial cable-mounted helical coil antenna designed specifically for this application was investigated as a means to increase the treated volume of cardiac tissue in a controllable and efficient manner during ablation. Using an array of fiber optic temperature probes implanted in a saline-perfused, tissue-equivalent gel phantom model designed to simulate the myocardium during ablation, the heating pattern from the microwave antenna was characterized and compared to that induced by a commercial RF electrode catheter at 550 kHz. Effects of variable contact angle between the heat source and heart wall were assessed in terms of the radial penetration and overall volume of heated tissue. Heating patterns from the RF electrodes dropped off much more abruptly both radially and axially than the microwave antenna such that the volume of effectively heated tissue was more than ten times larger for the microwave antenna when the heat sources were well-coupled to the tissue, and more than four times larger for the microwave antenna when the sources were angled 30 degrees away from the tissue surface.

Catheter Ablation↗

Evaluation of a semi-cylindrical solenoid as an applicator for radio-frequency hyperthermia.

A modified solenoid having a semi-circular cross section is evaluated as an applicator for radio-frequency heating of biological materials. The operating efficiency of this applicator and the distribution of the electric field established within a simulated biological sample are determined for a number of modes of excitation. It is shown that uniform heating to a substantial depth is possible at efficiencies in excess of 80 percent.

Electric Conductivity↗

Temperature-controlled and constant-power radio-frequency ablation: what affects lesion growth?

Radio-frequency (RF) catheter ablation is the primary interventional therapy for the treatment of many cardiac tachyarrhythmias. Three-dimensional finite element analysis of constant-power (CPRFA) and temperature-controlled RF ablation (TCRFA) of the endocardium is performed. The objectives are to study: 1) the lesion growth with time and 2) the effect of ground electrode location on lesion dimensions and ablation efficiency. The results indicate that: a) for TCRFA: i) lesion growth was fastest during the first 20 s, subsequently the lesion growth slowed reaching a steady state after 100 s, ii) positioning the ground electrode directly opposite the catheter tip (optimal) produced a larger lesion, and iii) a constant tip temperature maintained a constant maximum tissue temperature; b) for CPRFA: i) the lesion growth was fastest during the first 20 s and then the lesion growth slowed; however, the lesion size did not reach steady state even after 600 s suggesting that longer durations of energy delivery may result in wider and deeper lesions, ii) the temperature-dependent electrical conductivity of the tissue is responsible for this continuous lesion growth, and iii) an optimal ground electrode location resulted in a slightly larger lesion and higher ablation efficiency.

Arrhythmias, Cardiac↗

Finite element analyses of uniform current density electrodes for radio-frequency cardiac ablation.

The high current density at the edge of a metal electrode causes hot spots, which can lead to charring or blood coagulation formation during radio-frequency (RF) cardiac ablation. We used finite element analysis to predict the current density distribution created by several electrode designs for RF ablation. The numerical results demonstrated that there were hot spots at the edge of the conventional tip electrode and the insulating catheter. By modifying the shape of the edge of the 5-mm tip electrode, we could significantly reduce the high current density at the electrode-insulator interface. We also studied the current density distribution produced by a cylindrically shaped electrode. We modified the shape of a cylindrical electrode by recessing the edge and filled in a coating material so that the overall structure was still cylindrical. We analyzed the effects of depth of recess and the electrical conductivity of the added material. The results show that more uniform current density can be accomplished by recessing the electrode, adding a curvature to the electrode, and by coating the electrode with a resistive material.

Catheter Ablation↗