Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Protective Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

[Occupational health of endoscope sterilization workers in medical institutions in Osaka Prefecture].

To clarify the actual condition of endoscope sterilization work and the adverse health effects of disinfectants on personnel, a questionnaire was sent to 173 medical institutions in Osaka Prefecture. Glutaraldehyde (GA), ortho-phtalaldehyde (OPA), and hyperacetic acid were used as disinfectants of endoscopes by 55.5%, 32.4%, and 8.7% of the medical institutions respectively. The kind of disinfectant used had been changed in 57.8% of these institutions during the past five years, and it was confirmed that the use of substitutes for GA, such as OPA and hyperacetic acid, has increased. Personnel in 35.8% of the institutions complained about symptoms during sterilization work. The kind of disinfectant being used when they complained was GA in many cases and OPA in others. A general ventilation system has now been installed in 72.3% of the institutions; local exhaust systems have been installed in fewer, only 23.4%. Protective gloves were used at about half of the institutions, but protective masks and glasses were seldom used. This study shows that the occupational health problems of endoscope sterilization work have not been resolved. Consequently, it is necessary to promote the installation of ventilation systems and the use of protective devices in all institutions. Health education in regard to the handling of disinfectants is also necessary. Because little information is available about the toxic effects of OPA and hyperacetic acid, epidemiological studies must be conducted to clarify the human health effect of these disinfectants.

Acetic Acid↗

Intravascular ultrasound to guide the management of intracoronary thrombus: a case report.

Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction. We discuss the role of intravascular imaging to guide the use of a distal protection device by describing the outcome of a young woman presenting with non-ST elevation myocardial infarction. Coronary angiography demonstrated an isolated minor stenosis in the proximal left anterior descending coronary artery with slight haziness beyond the lesion. Intravascular ultrasound confirmed an extensive thrombus overlying a bulky atherosclerotic plaque. A distal filter wire was therefore successfully used to reduce the risk of distal embolization. The use of intravascular ultrasound in patients presenting with acute coronary syndrome may reveal large thrombi that are difficult to image using conventional angiographic techniques. Intravascular ultrasound can therefore be used as a tool to select lesions requiring distal protection.

Adult↗

Plaque characterization and atherosclerosis evaluation by coronary angioscopy.

When observed by angioscopy, the culprit lesions of acute coronary syndrome (ACS) have a common appearance of a yellow plaque with irregular surface covered by a thrombus. Angioscopy is a powerful device to detect not only the ruptured plaques at ACS lesions but also the yellow plaques in their early stages. The culprit lesions of ACS are sometimes detected by angioscopy even in the angiographically normal segments of coronary arteries. Angioscopy can further classify the culprit lesions of ACS as (1) vasospasm, (2) plaque rupture, or (3) plaque erosion according to the angioscopic definitions. These classifications may be beneficial to determine the treatment strategy. Anti-vasospastic medications rather than stenting may be more suitable for the treatment of vasospasm-induced ACS. Percutaneous coronary intervention (PCI) of ruptured plaque rather than of erosive plaque tends to cause more distal embolization with thrombus and plaque contents. Therefore, distal protection device may be more beneficial for those cases. Although angioscopy may be able to identify vulnerable plaques as the plaques of intensive yellow color, it may be more practical to identify the patients at high risk of suffering ACS by evaluating the extent of coronary atherosclerosis. The process and the time course of plaque formation, maturation, and disruption are left to be clarified, however, the number of yellow plaques or the yellow color intensity of those plaques may be a marker of coronary atherosclerosis. Angioscopy should be useful not only as a diagnostic tool but also as an investigational tool. The effect of medications that regress coronary atherosclerosis may be evaluated by the angioscopically determined markers of coronary atherosclerosis.

Acute Disease↗

[Procedures, spectrum and radiation exposure in CT-fluoroscopy].

PURPOSE: To assess the techniques, indications and radiation exposures incurred with CT fluoroscopy. MATERIAL AND METHODS: A 1-year period of use of CT fluoroscopy to guide diagnostic and therapeutic interventional procedures was analyzed. The spectrum of indications, different CT fluoroscopic methods and radiation exposures for the radiologist were assessed. Scatter exposures were measured with and without placement of a lead drape on the patient, with and without use of thin rubber radiation protection gloves. In addition, scattered radiation was determined for a combination of lead drape and radiation protection gloves. RESULTS: There is a wide variety for the use of CT fluoroscopy ranging from diagnostic biopsy procedures to therapeutic interventions such as radiofrequency ablation of liver metastases and CT fluoroscopy-guided osteosynthesis of fractures. Scatter exposure rates to the radiologists hand ranged from 1-320 microSv/case without use of a lead drape and without radiation protection gloves. The lead drape reduced the scattered exposure for the radiologists hand by 72%. Radiation protection gloves reduced scatter radiation by 49%. The combination of both radiation protection devices was most effective in decreasing the dose by 97%. CONCLUSIONS: CT fluoroscopy is a useful targeting method with a wide variety for interventional procedures. However, significant radiation exposures may occur. Therefore, the radiologists should be aware of different techniques of CT fluoroscopy guidance and the methods to reduce scatter radiation.

Adolescent↗

Carotid artery stenting--current status and future directions.

Carotid endarterectomy has been the standard of therapy for carotid occlusive disease in stroke prevention. More recently, carotid angioplasty and stenting became an important alternative in the treatment of carotid occlusive disease. The widespread use of cerebral protection devices has substantially decreased the morbidity of the procedure. As the experience with carotid stenting increases, so does the enthusiasm for the potential of this minimally invasive carotid intervention to become the main treatment option for the high risk patients, as well as for the average asymptomatic patient. Although current available data indicate that the results regarding success and complication rates are similar between carotid stenting and endarterectomy, several prospective clinical trials are currently in progress to evaluate the efficacy of carotid artery stenting in different patient populations and definitively establish its role in the treatment of carotid disease. This paper reviews the current status of carotid stenting, including results from clinical trials, technical aspects and controversial issues and strategies to provide cerebral protection from embolization.

Angioplasty, Balloon↗

A monitoring study of workers handling pesticides in warehouses and godowns.

Monitoring observations made on 60 operators involved in pesticide application work in godowns and warehouses and 60 matched control workers are reported. Occupational exposure history and medical history are noted. Biochemical investigations, plasma and RBC cholinesterase estimations are included along with medical examination of the workers. Workers were found to be mostly exposed to Celphos, DDVP, Malathion, Pyrethrum, etc, and the use of protective devices were very limited. Cases of significant reduction in plasma and RBC cholinesterase activity were found. Frequency of symptoms like dizziness, headache, lachrymation, burning sensation in eyes, nausea and anorexia, etc, were much more in the exposed workers. No cases of clinical poisoning attributable to occupational exposure to pesticides were reported by the workers.

Adult↗

Appropriateness of learning curve for carotid artery stenting: an analysis of periprocedural complications.

OBJECTIVES: Cerebral embolism is the first cause of neurologic complications of carotid artery stenting (CAS). A large debate has been raised to identify the caseload necessary for an appropriate learning curve before systematic use of CAS. This study examined (1) the timing of periprocedural complications during CAS and how these complications vary over time to identify factors that contribute to neurologic morbidity and (2) a sufficient number of procedures for adequate training. METHODS: During 2001 to 2006, 627 CAS procedures with cerebral protection devices (CPD) were performed in a single vascular surgery center by a team including a vascular surgeon and an interventional radiologist. These represented 38% of a total of 1598 carotid revascularizations performed in the same interval. CAS procedures were divided into two groups according to time interval: the first period, 2001 to 2003, included 195 CAS procedures, and the second period, 2004 to 2006, included 432 CAS procedures. During each CAS procedure, five major steps were considered: phase 1, or the catheterization phase, included the passage of the aortic arch, catheterization of the target vessel, and introduction of a guiding catheter or sheath. Phase 2, or the crossing stenosis phase, included the placement of a CPD. Phase 3, or the stent ballooning phase, included predilation (when indicated), stent implantation, postdilation, and recovery of the protection system. Phase 4, or the early postinterventional phase, included the first 24 hours after leaving the catheterization table. Phase 5, or the late postinterventional phase, included the interval from the first postoperative day to 30 days. RESULTS: At 30 days, 10 major strokes (2 of which were fatal) and 1 cardiac death occurred, for an overall major stroke/death rate of 1.75%. Furthermore, 18 minor strokes (2.9%) were recorded. By analyzing the occurrence of major strokes according to the three intraprocedural phases, four occurred in phase 1 and six in phase 3. All strokes but one were ischemic; six were ipsilateral, three were contralateral, and one was posterior. Minor strokes occurred prevalently after the procedure (11 in phase 4, 5 in phase 5, and 1 for phases 1 and 3). Comparing the first with the second interval of the study period, the 30-day major stroke and death rate decreased from 3.1% to 0.9% (P = .047), and the 30-day any stroke and death rate decreased from 8.2% to 2.7% (P = .005). According to multivariate analysis, study interval (hazard ratio, 3.68; 95% confidence interval, 1.49-9.01; P = .005) and age (hazard ratio, 1.06; 95% confidence interval, 1.00-1.12; P = .05) were significant predictors of stroke. CONCLUSIONS: A large proportion of major strokes (4/10) from CAS cannot be prevented by using CPD, because these strokes occur during catheterization (phase 1). This finding, together with the significant decrease in the overall stroke/death rate between the first and the last interval of the study period, enhances the importance of an appropriate learning curve that involves a caseload larger than that generally accepted for credentialing. The noticeable number of postprocedural cerebral embolizations leading to minor strokes and occurring in the early and late postinterventional phases (16/18) is likely due to factors less strictly related to the learning-curve effect, such as stent design and medical therapy. Moreover, expertise in selecting material and design of the stents according to different vessel morphology, in association with correct medical treatment, may be useful in reducing the number of minor strokes that occur in the later postinterventional phases of CAS.

Age Distribution↗

[Impact of secondary irradiation on operators during coronary arteriography].

BACKGROUND: The activity over cellular genetic pattern of ionizing radiation can produce stochastic and unspecific damages. Interventional cardiology operators have increasing exposure times to ionizing radiation and there is no information about the real protection conferred by simple radiological protection devices. AIM: To assess the magnitude of secondary ionizing radiation exposure of operators during conventional coronary arteriography, evaluating the radiation exposure during different beam projections and the usefulness of leaded aprons. MATERIAL AND METHODS: Ionizing radiation received by operators during coronary arteriography was measured using a Geiger-Müller Victoreen model 490 counter. The device was placed in the ventral region, covered by the leaded apron and in the unprotected dorsal region. Radiation was measured in right and left projections during fluoroscopy and shooting. RESULTS: In right projection, the intensity of ionizing radiation in ventral and dorsal regions was 1.24 +/- 1.1 and 2.9 +/- 4 mR/h respectively (p = 0.08). In left projection, the figures were 2.95 +/- 3 and 7.86 +/- 7.2 mR/h respectively (p = 0.001). During shooting in left projection the radiation exposure in ventral and dorsal regions was 9.66 +/- 6.7 and 32.8 +/- 27 mR/h respectively (p < 0.001). During shooting in right projection that figures were 10.1 +/- 16 and 20.7 +/- 39.8 mR/h respectively (p = 0.09). No correlation between radiation exposure and patients surface area was observed. CONCLUSIONS: Secondary radiation received by operators is higher during shooting and in left projections. Leaded apron confers a partial protection for ventral region, and great fluctuations in the magnitude of radiation exposure were recorded. Unprotected dorsal region receives a greater amount of radiation in left projections.

Age Distribution↗

Most Comfortable Listening Level and Speech Attenuation by Hearing Protectors.

Hearing protectors attenuate both the background noise and the useful sounds embedded in noise such as the sounds of speech and warning signals. An effective hearing protector is one that attenuates background noise while leaving sufficient energy of speech and warning signals to reach the ear of the worker. At present, however, there are no established criteria for assessing effective change in speech-to-noise ratio caused by hearing protection devices (HPDs). One such criterion could be a change in most comfortable (listening) level (MCL) for speech caused by the presence of HPDs. In this study the HPD-related shift in MCL for speech presented in quiet was measured and compared with two measures of noise attenuation: Noise Reduction Rating (NRR) and high-medium-low (H-M-L). The results indicate that the MCL shift may be a sensitive measure of speech attenuation by HPDs, which together with the appropriate H-M-L may describe technical properties of HPDs.

hearing protection↗

[The use of the Export Catheter device in a patient with acute myocardial infarction for thrombotic occlusion of the venous graft on the left anterior descending coronary artery: a case report].

Coronary angioplasty, eventually followed by stent implantation, represents the gold standard of acute myocardial infarction (AMI) treatment. Optimal reperfusion implies both patency of the infarct-related artery and a good myocardial microrevascularization with normal tissue reperfusion. The so called no-reflow phenomenon mainly occurs in the presence of highly thrombotic lesions, especially during primary angioplasty and it represents a negative prognostic factor of the outcome of AMI patients treated with angioplasty. A 77-year-old high-risk male patient, previous coronary artery bypass graft with the saphenous vein graft to the left anterior descending coronary artery for post-AMI angina in 1984, aided by 118 ambulance for anterior AMI was admitted to our cath-lab for primary coronary angioplasty. During the transport he was given aspirin i.v. 300 mg, heparin 5000 IU and abciximab (9.4 ml bolus plus infusion for 12 hours). The time of treatment (from symptom onset to first inflation) was about 90 min. Coronary angiography showed a massive thrombus occlusion of the vein graft with TIMI 0 distal flow. We employed the Export Catheter for mechanical aspiration of the occluding thrombus. The procedure was completed with direct stent implantation with good angiographic outcome. The use of thrombus aspiration and protection devices (filters or occlusive balloons) associated or not with the use of glycoprotein IIb/IIIa receptor blockers, has reduced the risk of distal embolization and of no-reflow phenomenon.

Aged↗

Predicting angiographic distal embolization following percutaneous coronary intervention in patients with acute myocardial infarction.

The aim of this study was to investigate the relation between lesion morphology identified by intravascular ultrasound (IVUS) before intervention and angiographic distal embolization after percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI). PCI for AMI has already been established as beneficial therapy, although some complications remain unresolved. Distal embolization is 1 of the important complications of PCI. Recently, some new devices have been developed for the prevention of distal embolization. However, few studies exist that look into the relation between lesion morphology and distal embolization. IVUS was performed safely in 140 consecutive patients with AMI before coronary intervention. No patient received thrombolytic therapy. From the incidence of angiographic distal embolization, patients were divided into 2 groups--an embolization group and a nonembolization group--and clinical background, IVUS, and angiographic information were evaluated. Distal embolization was observed in 12 patients (9%). Peak creatine kinase levels (3,877 +/- 2,285 vs 2,293 +/- 1,792 IU/L, p <0.05) and the incidence of angiographic thrombus (25% vs 5%, p <0.05) and intracoronary mobile mass detected by IVUS (75% vs 16%, p <0.001) were higher for patients in the embolization group. From the multivariate logistic regression analysis, only an intracoronary mobile mass detected by IVUS emerged as a predictor of distal embolization (odds ratio 53, 95% confidence interval 2.7 to 1,040, p <0.01). Patients with an intracoronary mobile mass detected by IVUS are prone to distal embolization after PCI and larger infarction. IVUS imaging before PCI may be useful for determining which patients need a distal protection device.

Aged↗

Late effects after radiotherapy for prostate cancer in a randomized dose-response study: results of a self-assessment questionnaire.

OBJECTIVES: To evaluate the late effects more than 2 years after radiotherapy using a patient-reported questionnaire in patients with prostate cancer enrolled in a randomized dose-response study comparing 70 Gy (conventional) and 78 Gy (conformal) radiotherapy (RT). METHODS: The first 112 patients in the study were sent questionnaires to evaluate late bladder, rectal, and sexual function. There were 101 evaluable responses, with 50 in the conventional (Conven-RT) arm and 51 in the conformal (3DCRT) arm. RESULTS: The overall rate of persistent incontinence was 29%, with 36% reporting urgency-related and 8% stress-related incontinence at some time after radiation. Use of a urinary protective device was required in 2%. The majority noticed leakage less than once per day (52%). In comparing the Conven-RT group with the 3DCRT group, similar incontinence rates were seen. However, fewer of those who received 3DCRT reported daily leakage of urine (33% versus 63%, P = 0.044). The majority (78%) of patients experienced no or mild change in bowel function after RT. Urgency of bowel movements (BMs) was of concern for 27% of patients; however, 90% reported their BMs were controlled without accidents, and 1% were taking antidiarrheal medications once a week or daily. The Conven-RT group had more moderate or major changes in bowel function than the 3DCRT group (34% versus 10%), more frequent BMs (47% versus 27%), and more urgent BMs (37% versus 18%) (P < or = 0.040 for all three comparisons). Hematochezia was uncommon, occurring once a week in 7% and daily in 4% of patients. Before RT, 80% of patients were potent, with erections adequate for intercourse at least a few times over the prior year. After RT, potency was decreased to 51%, with erections adequate for intercourse at least a few times since the completion of RT. CONCLUSIONS: The overall rates of significant complications were extremely low. Although 30% reported incontinence, relatively few patients (2%) required pads. This rate compares favorably with the 31% of patients requiring protection after radical prostatectomy reported previously. Despite the higher treatment doses in the 3DCRT arm, slightly fewer long-term bowel side effects were noted. These data indicate that 78 Gy may safely be delivered using the conformal RT boost treatment technique described.

Dose-Response Relationship, Radiation↗

Self reported respiratory symptoms and diseases among hairdressers.

OBJECTIVES: Hairdressers are exposed to many irritative and allergenic substances capable of causing occupational respiratory symptoms and diseases. The self reported prevalence of respiratory symptoms and diseases was studied, and the risks among hairdressers compared with saleswomen was estimated. METHODS: A cross sectional prevalence study of respiratory symptoms and diseases was carried out among hairdressers and supermarket saleswomen, with a computer assisted telephone interview method (CATI). The study population comprised all the female hairdressers and supermarket saleswomen aged 15-54 years in the Helsinki metropolitan area, Finland. Disproportionate random samples of female hairdressers and sales-women were drawn from the trade union membership registers. The interviews were carried out between February and April 1994. A response rate of 80.5% (355/440) was obtained for hairdressers and 82.2% (583/709) for saleswomen. Atopy, smoking, chronic illnesses, type of work, working hours, working conditions, personal and professional use of hair products, and the use of personal protective devices were assessed. The outcome variables were self reported symptoms of the upper and lower respiratory tract. These were used to define chronic bronchitis, and asthma, laryngitis, and allergic rhinitis diagnosed by a physician. RESULTS: There was a considerable difference in the prevalence of chronic bronchitis; 6.8% in hairdressers versus 1.9% in saleswomen. The odds ratio (OR) adjusted for age, smoking, and atopy for chronic bronchitis indicated an increased risk of chronic bronchitis (OR 4.8, 95% confidence interval (95% CI) 2.2 to 10.1). No association was found between work as a hairdresser and asthma, laryngitis, and allergic rhinitis. Also the prevalence of rhinitis, rhinitis with eye symptoms, cough with phlegm, dyspnoea, and dyspnoea accompanied by cough was increased among hairdressers. The corresponding adjusted risk ORs were 1.7 (95% CI 1.3 to 2.3) for rhinitis, 1.9 (95% CI 1.4 to 2.6) for rhinitis with eye symptoms, 1.4 (CI 1.1 to 1.9) for cough with phlegm, 1.5 (95% CI 1.0 to 2.2) for dyspnoea, and 1.6 (95% CI 1.0 to 2.7) for dyspnoea with cough. CONCLUSIONS: Our results indicate an increased prevalence of upper and lower respiratory symptoms among hairdressers. Allergenic and irritative chemicals in hairdressing are likely candidates explaining the difference found between the hairdressers and controls. Work related reasons should be considered when a hairdresser presents with airway symptoms. Preventive actions are needed to improve the working conditions and personal protection.

Adolescent↗

Heat stress associated with the use of vapor-barrier garments.

Use of personal protective devices in the workplace, while intended to diminish risk of injury, may in some cases increase personal risk from environmental hazards. A case of a juvenile diabetic with complaints of near syncope while working in a plastics laminating process is analyzed. Although his symptoms might be attributed to a variety of causes, they were traced to the effects of heat stress related to wearing vapor-barrier disposable coveralls in a warm environment (85 degrees F). A field study of asbestos workers involved in abatement of asbestos steam pipe insulation illustrates how clothing impermeable to sweat may result in elevation of core body temperature. When workers use vapor-barrier coveralls, work practices or wet bulb globe temperature limits may need to be revised to prevent heat-related injury.

Adult↗

Prevention of allergy to acrylates and latex in dental personnel.

Contact allergy to acrylate monomers and immediate hypersensitivity to latex gloves in dental personnel calls for preventive measures to reduce the risks. The aim of the study was to evaluate the preventive effect of an information campaign after a 3-year follow-up. The campaign included instructions and training according to an ordinance, both in writing and orally, e.g. concerning the choice of products and protection devices and the proper handling of the materials. The follow-up was carried out through 1997-2000 and included all eligible 513 subjects. Information on new cases was ascertained by a questionnaire and reports from the occupational health service and the department of dermatology. The number of expected new cases was based on the incidence rate, derived from a preceding prevalence study in the same county, and the exposed years at risk in the follow-up period. No new case of allergy to acrylates or latex rubber was found in the follow-up period as against 4.91 expected (p = 0.007). In conclusion, this study indicates that occupational allergies can be prevented successfully, but requires vigorous measures to influence the behaviour and the routines of daily work in dental practice.

Acrylates↗

Radiation protection in radionuclide therapies with (90)Y-conjugates: risks and safety.

PURPOSE: The widespread interest in (90)Y internal radionuclide treatments has drawn attention to the issue of radiation protection for staff. Our aim in this study was to identify personnel at risk and to validate the protection devices used. METHODS: (90)Y-MoAb (Zevalin, 15 cases, 1.1 GBq/patient) and (90)Y-peptide ((90)Y-DOTATOC) systemic (i.v., 50 cases, 3.0 GBq/patient) and locoregional (l.r., 50 cases, 0.4 GBq/patient) treatments were considered. Radiolabelling was carried out in a dedicated hot cell. Tele-tongs, shielded (PMMA: polymethylmethacrylate) syringes/vials and an automatic dose fractionating system were used. Operators wore anti-X-ray and anti-contamination gloves, with TLD dosimeters placed over the fingertips. For i.v. administration, activity was administered by a dedicated system; for l.r. administration, during activity infusion in the brain cavity, tongs were used and TLDs were placed over the fingertips. The air kerma-rate was measured around the patients. RESULTS: The use of devices provided a 75% dose reduction, with mean fingertip doses of 2.9 mGy (i.v. MoAbs), 0.6 mGy (i.v. peptides)/radiolabelling procedure and 0.5 mGy/l.r. administration. The mean effective dose to personnel was 5 microSv/patient. The air kerma-rate around the patients administered i.v. (90)Y-peptides were 3.5 (1 h) and 1.0 (48 h) microGy/h at 1 m. Patient hospitalisation of 6 h (l.r.)/48 h (i.v.) guaranteed that the recommended limits of 3 mSv/year to family members and 0.3 mSv/year to the general population (Council Directive 97/43/Euratom) were respected. CONCLUSIONS: When specific procedures are adopted, a substantial improvement in (90)Y manipulation is attainable, reducing doses and increasing safety. For the widespread clinical use of (90)Y-conjugates, a completely automatic labelling procedure is desirable.

Italy↗

Efficacy of a proximal occlusion catheter with reversal of flow in the prevention of embolic events during carotid artery stenting: an experimental analysis.

OBJECTIVE: The role of percutaneous angioplasty and stenting of carotid bifurcation lesions has been limited by its potential for producing embolic debris. We evaluated the efficacy of a proximal occlusion catheter (POC) in the prevention of embolic events during carotid artery stenting. In addition, pressure measurements relevant to the clinical application of this device were obtained from 10 patients undergoing carotid endarterectomy. METHODS: The POC is a guiding catheter with an occlusion balloon attached on the outside of the catheter at its distal end. Occlusion of the common carotid artery (CCA) was achieved by inflating the balloon while access to carotid bifurcation lesions was obtained through the inner lumen. The POC was inserted in the CCA of 10 dogs via the femoral artery. The side port of the POC was connected to a sheath placed in the femoral vein, thereby creating an external arteriovenous shunt. Ten artificial radiopaque particles simulating embolic particles and contrast agent were introduced in the CCA and monitored fluoroscopically. As a control, the same procedure was performed with a standard guiding catheter without an occlusion balloon. In 10 patients undergoing carotid endarterectomy, the internal carotid artery (ICA) and external carotid artery stump pressures and the pressure in the internal jugular vein were measured. RESULTS: Without the external arteriovenous shunt, in all animals there was prograde flow in the distal CCA despite CCA occlusion. This flow was derived from the thyroid artery. However, once the arteriovenous shunt was activated, reversal of flow in the distal CCA was achieved in each animal, and all the artificial particles were recovered from the side port of the POC. In the control group, each particle embolized to the brain (100%, P <.01). In the patients, the mean stump pressures in the ICA and external carotid artery and the jugular vein pressure were 51.8 +/- 14.2, 62.2 +/- 15.1, and 6.5 +/- 3.5 mm Hg, respectively. In each case, the jugular vein pressure was the lowest among the three. CONCLUSIONS: Obtaining proximal CCA control by inflating the POC does not sufficiently prevent embolization. However, reversal of flow in the ICA can always be created with the external shunt, which effectively prevents embolization. Thus, POC may markedly lower procedural stroke rates during carotid artery stenting. The ability of POC to prevent embolization before crossing the lesion with a guidewire may be an important advantage over other distal protection devices.

Angioplasty, Balloon↗

Identification of less-irradiating tube angulations in invasive cardiology.

OBJECTIVES: We sought to identify tube angulations in invasive cardiology, which promise minimal radiation exposure to patients and operators. BACKGROUND: Radiation exposure in invasive cardiology is high. METHODS: We mapped the fluoroscopic dose-area product per second (DAP/s), applied to an anthropomorphic Alderson-Rando phantom and, in absence of radiation protection devices, the mean personal dose in the operator's position in 10 degrees steps from the 100 degrees right anterior oblique (RAO) to the 100 degrees left anterior oblique (LAO) projection, as well as for all geometrically feasible craniocaudal tube angulations. RESULTS: For our specific setting conditions RAO 20 degrees /0 degrees tube angulation generated the lowest DAP/s and operator's personal dose. The mean patient DAP/s and operator personal dose for all postero-anterior (PA) projections, cranialized and caudalized together, rose significantly: 3.7 and 10.6 times the PA 0 degrees baseline values toward LAO 100 degrees and 3.7 and 2.4 times toward RAO 100 degrees , respectively. Patient and operator values for all PA projections, angulated to the right and left, increased approximately 2.5 times toward 30 degrees craniocaudal angulations. Caudal PA 0 degrees /30 degrees - angulation instead of caudal LAO 60 degrees /20 degrees - angulation for the left coronary main stem and cranial PA 0 degrees /30 degrees + view in place of cranial LAO 60 degrees /20 degrees + view for the left anterior descending coronary artery bifurcation enable 2.6-fold dose reductions to the patient and eight- and five-fold dose reductions to the operator, respectively. CONCLUSIONS: The PA views and RAO views >or=40 degrees , heretofore unconventional in clinical routine, should be favored over steep LAO projections >or=40 degrees whenever possible. Tube angulations that are radiation intensive to the patient exponentially increase the operator's radiation risk.

Angioplasty, Balloon, Coronary↗