Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PIPET”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

Novel cell surface adhesion receptors involved in interactions between stromal macrophages and haematopoietic cells.

Immunocytochemical staining of tissues with the mouse macrophage-specific monoclonal antibody, F4/80, has shown that large numbers of stromal macrophages are present in adult and foetal haematopoietic tissues. Macrophage plasma membrane processes are seen to establish extensive associations with myeloid and erythroid cells in adult bone marrow and with developing erythroblasts in foetal liver, suggestive of local trophic interactions. To explore the nature of these interactions, methods were developed for isolation of resident bone marrow macrophages (RBMM) and foetal liver macrophages (FLM). Following collagenase digestion of bone marrow or foetal liver, clusters were obtained which were composed of one or more central macrophages surrounded by proliferating haematopoietic cells. After attachment of clusters to glass coverslips, adherent macrophages could be stripped free of haematopoietic cells by pipetting in the absence of divalent cations. The purified RBMM, but not FLM, expressed a novel haemagglutinin, which mediated binding, without ingestion, of large numbers of unopsonized sheep erythrocytes by a divalent cation-independent mechanism. In view of the possibility that this sheep erythrocyte receptor (SER) could interact with a homologous ligand on mouse bone marrow cells, its properties were examined. SER was found to be a lectin-like protein which recognized protease-resistant sialylated glycoconjugates on sheep erythrocytes. The expression of SER was restricted to certain stromal tissue macrophages and was low or absent on monocytes and macrophages obtained from serous cavities. High levels of SER could be induced on elicited peritoneal macrophages by cultivation in mouse serum and the induced receptor was found to mediate low-avidity binding of murine bone marrow cells with characteristics indistinguishable from those seen for binding of sheep erythrocytes. However, maximal binding of bone marrow cells to RBMM depended on a distinct, divalent cation-dependent adhesion system. Using erythroblasts as a ligand, FLM were selected to explore the properties and expression of this adhesion receptor, the erythroblast receptor (EbR). Similar to SER, EbR did not mediate ingestion, and was restricted in its expression to foetal and adult stromal tissue macrophages. Unlike SER, EbR activity was not affected by neuraminidase treatment of the ligand and the receptor was not induced on peritoneal macrophages cultured in mouse serum. EbR appears to be a novel cell adhesion receptor because it was unaffected by inhibitors of several previously described cell adhesion molecules, including the fibronectin receptor. Future studies will attempt to explore the f

Animals↗

[Signal transduction of serotonin release from enterochromaffin cells in mouse ileal crypts].

Although serotonin (5-HT) release from enterochromaffin (EC) cells is considered to be regulated by multiple receptor-mediated mechanisms, little is known about the signal transduction in EC cells. We investigated the effects of adrenoceptor stimulation on 5-HT release from ileal tissue and intracellular calcium dynamics of epithelial cells in isolated ileal crypts in mice. Ileal tissues placed in organ bath were perfused with a buffered solution. Released 5-HT was measured using HPLC-ECD. Ileal crypts were isolated by collagenase digestion followed by moderate pipetting. Intracellular calcium dynamics were analyzed by digital video-imaging system using fura-2. NE, but not isoprenaline (Iso), induced 5-HT release from mouse ileal tissue. NE-induced 5-HT release was antagonized by yohimbine and rauwolscine, but not by prazosin and bunazosin. NE, but not Iso, also elicited a transient elevation of intracellular calcium in some EC cells. The effect of NE (1 microM) was slightly suppressed by prazosin and bunazosin, but was remarkably suppressed by yohimbine and rauwolscine. UK 14,304 and Clonidine at 10 microM significantly induced an increase in intracellular calcium concentration. NE-induced intracellular calcium dynamics was not significantly affected by timolol, Ro20-1724, rolipram and 8-bromo-cAMP. These results suggest that NE-induced 5-HT release from ileal EC cells is mediated predominantly via alpha 2-, but not beta-adrenoceptors, by a mechanism dependent on elevation of intracellular calcium concentration.

4-(3-Butoxy-4-methoxybenzyl)-2-imidazolidinone↗

[Analysis of intracellular calcium dynamics in enterochromaffin cells of small intestine].

Although serotonin (5-HT) release from enterochromaffin (EC) cells is considered to be regulated by multiple receptor-mediated mechanisms, little is known about the signal transduction. Here, we introduce the methods to isolate the mouse ileal crypts, which consist of various types of cells including EC cells, and to analyze the intracellular calcium dynamics. Ileal tissue was inserted with a plastic straw and the smooth muscle layers were peeled off. The mucosa were digested with collagenase and then suspended by moderate pipetting. Ileal crypts were separated by stepwise filtrations through 2 different nylon-meshes. The isolated crypt contained 0-3 EC cells as identified by immunostaining using anti-5-HT antibody followed by confocal microscopy. Isolated crypts were attached to a coverglass by an adhesive material (Cell-Tak) and loaded with fura-2/AM. Intracellular calcium dynamics in EC cells were obtained by digital video-imaging analysis of fura-2 fluorescence followed by the identification of EC cells with immunostaining of 5-HT granules. By these methods, it was suggested that norepinephrine elicited a transient elevation of intracellular calcium concentration in EC cells via alpha 2-adrenoceptors. These methods could be also useful to analyze the signal transduction system in intestinal endocrine cells that contain various intestinal hormones such as gastrin, cholecystokinin or secretin.

Animals↗

Human ATP-binding cassette transporter TaqMan low-density array: analysis of macrophage differentiation and foam cell formation.

BACKGROUND: ATP-binding cassette (ABC) transporters cause various diseases and regulate many physiologic processes, such as lipid homeostasis, iron transport, and immune mechanisms. Several ABC transporters are involved in bile acid, phospholipid, and sterol transport, and their expression is itself controlled by lipids. In addition, ABC proteins mediate drug export in tumor cells and promote the development of multidrug resistance. METHODS: We created an ABC Transporter TaqMan Low-Density Array based on an Applied Biosystems 7900HT Micro Fluidic Card. We used a 2-microL reaction well with 2 ng of sample. To evaluate this method for lipidomic research and to characterize expression patterns of ABC transporters in cells relevant for atherosclerosis research, we monitored mRNA expression in human primary monocytes, in vitro-differentiated macrophages, and cells stimulated with the liver-X-receptor and retinoid-X-receptor agonists T0901317 and 9-cis retinoic acid, mimicking sterol loading. RESULTS: The method enabled simultaneous analysis of 47 human ABC transporters and the reference gene 18S rRNA in 2 replicates of 4 samples per run. CONCLUSIONS: The new system uses only 2 ng of sample and small volumes of reagent, and the precaptured primers and probes avoided labor-intensive pipetting steps. The ABC Transporter TaqMan Low-Density Array may be a useful tool to monitor dysregulated ABC transporter mRNA profiles in human lipid disorders and cancer-related multidrug resistance and to analyze the pharmacologic and metabolic regulation of ABC transporter expression important for drug development in large-scale screening approaches.

ATP-Binding Cassette Transporters↗

Enzyme immunoassays (EIAs) of eicosanoids.

Enzyme immunoassay of eicosanoids is a nonradioactive, highly sensitive method of determining the concentration of eicosanoids in biological samples. Although relatively easy to use, the assays require a high level of precise pipetting technique and familiarity with critical points in the assay procedure. Although assay kits complete with plates, buffers, antibodies, tracers, and color development reagents are available, it is more economical to develop the assay within the laboratory if the assay is to be performed routinely. The only major disadvantage with EIA is that the investigator is limited to measuring eicosanoids with commercially available enzyme-tracers and antibodies. The labeling of particular eicosanoids by enzyme tracers is rarely, if ever, performed outside of industry. Growing of antibodies is conducted in many laboratories but is beyond the scope of this chapter. It requires a significant level of commitment of time and resources to establish the specificity of the antibody (i.e., does the antibody cross-react with eicosanoids of similar structure). Furthermore, this will not solve the problem of availability of eicosanoid-tracer. On the other hand, it must be noted that with the exception of the cytochrome P-450 metabolites of arachidonic acid, most of the major eicosanoids that are biologically active and are known to play regulatory roles in physiology and/or pathology, have commercially available antibodies and enzyme-tracers.

Eicosanoids↗

Mechanosensitive channel of Thermoplasma, the cell wall-less archaea: cloning and molecular characterization.

By using a functional approach of reconstituting detergent-solubilized membrane proteins into liposomes and following their function in patch-clamp experiments, we identified a novel mechanosensitive (MS) channel in the thermophilic cell wall-less archaeon Thermoplasma volcanium. Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) of the enriched protein fractions revealed a band of approx 15 kDa comparable to MscL, the bacterial MS channel of large conductance. 20 N-terminal residues determined by protein microsequencing, matched the sequence to an unknown open reading frame in the genome of a related species Thermoplasma acidophilum. The protein encoded by the T. acidophilum gene was cloned and expressed in Escherichia coli and reconstituted into liposomes. When examined for function, the reconstituted protein exhibited properties typical of an MS ion channel: 1) activation by negative pressure applied to the patch-clamp pipet, 2) blockage by gadolinium, and 3) activation by the anionic amphipath trinitrophenol. In analogy to the nomenclature used for bacterial MS channels, the MS channel of T acidophilum was termed MscTA. Secondary structural analysis indicated that similar to MscL, the T. acidophilum MS protein may have two transmembrane domains, suggesting that MS channels of thermophilic Archaea belong to a family of structurally related MscL-like ion channels with two membrane-spanning regions. When the mscTA gene was expressed in the mscL- knockout strain and the MscTA protein reconstituted into liposomes, the gating of MscTA was characterized by very brief openings of variable conductance. In contrast, when the mscTA gene was expressed in the wild-type mscL+ strain of E. coli, the gating properties of the channel resembled MscL. However, the channel had reduced conductance and differed from MscL in its kinetics and in the free energy of activation, suggesting that MscTA and MscL can form functional complexes and/or modulate each other activity. Similar to MscL, MscTA exhibited an increase in activity in liposomes made of phospholipids having shorter acyl chain, suggesting a role of hydrophobic mismatch in the function of prokaryotic MS channels.

Amino Acid Motifs↗

Adapting the Quesant Nomad atomic force microscope for biology and patch-clamp atomic force microscopy.

The Quesant Nomad atomic force microscope (AFM) was modified to produce a reliable patch-clamp AFM for demanding biologic applications. The AFM's laser optics forms the basis of a condenser that allows simultaneous Köhler illumination and AFM imaging on an inverted optical microscope. The original AFM scan head was replaced with plastic and glass to make it biologically inert. A bevel cut in the new scan head permits clearance for patch clamp pipets. Cantilevers are attached to the scan head with a quick setting silicone rubber that is readily removable. Software was developed to (a) automate a gentle approach and set a specific feedback force, (b) provide a mouse-driven control of the X-Y position of the probe tip and recall of saved locations, and (c) measure force-distance curves over user defined paths. Additional modifications were made to minimize mechanical noise. The patch-clamp AFM achieves 600 fA (3 kHz bandwidth) and 1 A RMS noise levels (10 kHz bandwidth). The correlation of electrical and mechanical information allows signal averaging and measures sub-Angstrom, sub-millisecond electromotile responses from cells.

Cell Membrane↗

[Circulating monocyte (macrophage)-specific antibodies in patients with autoimmune thyroid diseases].

We investigated the presence of circulating monocyte-specific antibodies (monocytotoxic activities) by cytotoxicity tests and also the relationships between these monocytotoxic activities and the clinical data in autoimmune thyroid diseases. Subjects of this investigation include 16 patients with Graves' disease, 20 patients with Hashimoto's thyroiditis and 10 normal controls. To obtain monocyte-rich population, peripheral blood mononuclear cells of type 0 healthy donor were incubated on culture dishes for 12 hours and dish adherent cells were separated by pipetting. These monocyte-rich population were incubated with sample sera which were previously absorbed by lymphocytes of many different kinds of HLA types to eliminate anti-lymphocyte antibodies, and thereafter cytotoxicity tests were performed by adding rabbit complements. The monocytotoxic activities were expressed by %cytotoxicities and the value of %cytotoxicity over 3.9% (mean + 4SD of %cytotoxicities of normal controls) was considered to be positive in monocytotoxic activity. The results indicate that; 1) 8 patients (50%) of Graves' disease and 10 patients (50%) of Hashimoto's thyroiditis had positive values of monocytotoxic activity. 2) These positive values of monocytotoxic activity were markedly decreased after absorption of sample sera by monocytes, and these patients who had positive values of monocytotoxic activities to allogenic monocytes also had positive values of monocytotoxic activities to autologous monocytes. 3) Patients who had positive monocytotoxic activities also had high levels of TSH receptor antibody (TRAb) and anti-microsomal antibody, besides, monocytotoxic activity was significantly correlated with levels of TRAb in Graves' disease.(ABSTRACT TRUNCATED AT 250 WORDS)

Autoantibodies↗

Toward automated nucleic acid enzyme selection.

Methods for automation of nucleic acid selections are being developed. The selection of aptamers has been successfully automated using a Biomek 2000 workstation. Several binding species with nanomolar affinities were isolated from diverse populations. Automation of a deoxyribozyme ligase selection is in progress. The process requires eleven times more robotic manipulations than an aptamer selection. The random sequence pool contained a 5' iodine residue and the ligation substrate contained a 3' phosphorothioate. Initially, a manual deoxyribozyme ligase selection was performed. Thirteen rounds of selection yielded ligators with a 400-fold increase in activity over the initial pool. Several difficulties were encountered during the automation of DNA catalyst selection, including effectively washing bead-bound DNA, pipetting 50% glycerol solutions, purifying single strand DNA, and monitoring the progress of the selection as it is performed. Nonetheless, automated selection experiments for deoxyribozyme ligases were carried out starting from either a naive pool or round eight of the manually selected pool. In both instances, the first round of selection revealed an increase in ligase activity. However, this activity was lost in subsequent rounds. A possible cause could be mispriming during the unmonitored PCR reactions. Potential solutions include pool redesign, fewer PCR cycles, and integration of a fluorescence microtiter plate reader to allow robotic 'observation' of the selections as they progress.

Automation↗

A rapid method for dry weight determination of proteins on a micro scale with an electrobalance.

A method to determine the dry weight (0.25-2 mg) of aqueous protein solutions within 1 h, using an electrobalance, is described. The drying of 50-200 mul solution pipetted onto a glass fiber disc is carried out in vacuo at 70 degrees C until the recorded dry weight becomes constant (within 25-40 min). It has been shown that the dried residue can subsequently be used for other purposes, such as quantitative amino acid analyses. The method is also suitable for the determination of moisture content in lyophilized protein samples.

Amino Acids↗

A modular analyzer system for double antibody radioimmunoassays.

The increasing number of determinations performed by radioimmunoassays necessitates rationalization of the procedures. An analyzer system has been developed in order to fully mechanize double antibody radioimmunoassays, which is essentially composed out of four independently working modules. The samples, in microliter vials, are carried in sample chains of up to 650 links. The first pipetting step is performed by syringes with displacement pistons. Additional reagents are rapidly added by an electronically controlled Hamilton repeating dispenser, which makes shaking procedures for mixing unnecessary. The bound/free separation is achieved discontinuously by use of Nuclepore-filters, which are carried in 3 inches distance (76 mm) by a 35 mm dark leader film. After covering the radioactive filter positions with an adhesive plastic foil from both sides, the film spool is directly inserted into a specially constructed gamma-counter. The results of the evaluation of the efficiency and of the precision of each module are presented in this paper.

Autoanalysis↗

Determination of copper and iron in human blood serum by energy dispersive x-ray analysis.

Human blood serum has been analyzed by X-ray fluorescence spectroscopy utilizing the effect of background reduction by total reflexion of the incident X-ray beam on an optical flat as sample support. For sample preparation a drop of 10 microliter serum was pipetted onto the support and dried to a thin film. The minimum detectable limit was about 1.5 mmol/l in 1000 s and the precision in the 20 mmol/l range of the metals was 3-5%.

Copper↗

An evaluation of the automated OLLI CD discrete analyser.

We report the evaluation of a novel clinical chemical analyser, the OLLI CD, which is highly automated compared to its predecessor, the OLLI 3000 analyser. The precision of the dispensing unit, the OLLI D, was assessed with the aid of aqueous solutions of 131I. Sample pipetting of 10 microliter resulted in a coefficient of variation of 0.81%. Lower volumes were unreliable. However, precision of the addition of start reagent for kinetic methods appeared to be only 2.7% for 20 microliter, 1.7% for 50 microliter and 2.1% for 250 microliter. The linearity of response and the precision of the photometer unit, the OLLI C, was assessed with cobalt(II)sulfate solutions. The linearity ranged up to an absorbance of 2.5. The reproducibility of the colorimeter ranged from A510nm 0.0011 to 0.0047. With this analyser good correlations were obtained for alanine aminotransferase (EC 2.6.1.2) vs LKB 8600 reaction rate analyser; for creatinine vs Mark II Autoanalyzer; and for total protein vs SMA 6/60 Autoanalyzer. These three determinations showed acceptable between-day variations. General instrument performance was acceptable.

Alanine Transaminase↗

The development of a direct homologous radioimmunoassay for serum cortisol.

This article describes the synthesis of a pure cortisol-3-(O-carboxymethyl) oxime with its subsequent use in producing highly specific antibodies and a 125I-tracer with a shelf life in excess of several weeks. An assay was developed using a pH of 4, thus allowing a direct measurement of cortisol in serum without extraction or heat denaturation. The quality-control parameters were checked - the intra-assay C.V. in the working range (area of clinical interest) was under 5%, and the interassay C.V. under 11%. Correlation studies with results using other antisera and with 3H-tracer are highly significant with the slope of the regression curve deviating less than 2% from the ideal volume. Finally the assay is fully automatable and is suitable for most automatic pipetting and analysis systems.

Animals↗

Evaluation of the optimized bioluminescent assay for the determination of total creatine kinase and creatine kinase MB activities.

A very sensitive, optimized bioluminescent assay for certain kinase and creatine kinase MB activities is tested. We evaluated reagent blanks, sensitivity, precision and compared the results with those of the spectrophotometric immunoinhibition test. The main advantage of the new method is a detection limit of less than 1 U/l which, together with a high precision (s = 0.1 at detection limit), allows determinations of the creatine kinase MB activity even in normal sera in about 20 minutes. A disadvantage of the manual procedure is that it may be necessary to include up to five pipetting steps.

Creatine Kinase↗

Comparison of the automated random access immunoassay analysers, ACS-180 (Ciba Corning) and AIA-1200 (Tosoh).

Two random access immunoassay analysers, the ACS-180 (Ciba Corning) and the AIA-1200 (Tosoh Corp.) were compared with respect to performance and user-friendliness. Precision studies revealed an almost equal intra-assay variation coefficient, but day-to-day reproducibility was better on the AIA-1200. Recovery of dilution series of tumour markers was too high with the ACS-180. Both systems were free from carry-over effects, on account of the extra wash step in the ACS-180 (for thyrotropin, carcinoembryonic antigen and human chorionic gonadotropin) and the separate pipetting tip in the AIA-1200. Reagent stability is better in the AIA-1200 than in the ACS-180. The AIA-1200 is more user-friendly and produces a higher throughput than the ACS-180 in daily routine operation (92 results/hour vs. 78 results/hour).

Adolescent↗

A manual spectrophotometric method for the measurement of serum sodium and potassium by enzyme activation.

Manual procedures suitable for use on standard benchtop spectrophotometers have been developed for the enzymatic determination of Na+ and K+ in serum. Both assays require only minimal modification of reagents already available for BM/Hitachi analyzers and are performed in an endpoint mode, allowing up to 20 assays per run. The addition of a stop reagent is required--dipotassium EDTA for the Na+ assay and sodium dodecyl sulphate for the K+ assay. The most important criterion for achieving good assay performance is the precise pipetting of sample and reagent. Within-run imprecision is < 1% for Na+ and K+, and between-run imprecision < 1.5%, for both assays at all but the lowest concentrations of K+. Enzymatic electrolyte results compare well with flame photometry, however the assays are more prone to interference by very high concentrations of bilirubin or triacylglycerols than those performed on automated, dual-wavelength kinetic analyzers. It is possible to correct for most interferences by inclusion of appropriate sample and reagent blanks.

Absorption↗

Inter-laboratory evaluation of the COBAS INTEGRA 400 analytical system.

COBAS INTEGRA 400 is a random-access analytical system consolidating assays for clinical chemistry analytes, electrolytes, serum proteins, drugs of abuse and therapeutic drugs. Analytical performance and practicability of the instrument were evaluated in seven laboratories over a 2-year period in parallel with system development. Good within-run and total imprecision for all assays was observed with a few exceptions for specimen pools with low concentration or activity. The coefficients of variation for total imprecision were well below 3.0% for clinical chemistry analytes and electrolytes, and below 5.0% for serum proteins and therapeutic drugs. Method comparisons demonstrated a good agreement with the various systems used for comparison, with slopes varying typically from 0.94 to 1.05, and Spearman correlation coefficient generally > 0.975. Accuracy was verified by recovery of controls and certified reference materials within 90 to 110% of target values. Assay ranges were linear within +/- 5%. No carry-over on reagent or sample pipetting systems was observed. Manufacturer-specified interference limits and onboard stabilities of reagents were confirmed. A time study for calculating direct personnel times and total processing time was carried out in three laboratories under different conditions including consolidated, STAT and dedicated use. On a scenario-independent basis, the total working time was shorter on the COBAS INTEGRA 400 than on routine systems in all three laboratories. Personnel time, in particular, was significantly reduced when compared to routine instruments. In general, system practicability was judged very positively in all laboratories. Owing to its versatility, the instrument is best placed as a consolidated workstation in small- to medium-sized laboratories or as an instrument for special determinations such as serum proteins, drugs, urinalysis or emergency analyses in large laboratories.

Blood Proteins↗