Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PERFUME”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

Fragrance allergy and hand eczema - a review.

Because hand eczema and fragrance allergy are common both among patients and in the general population, simultaneous occurrence by chance must be expected. Fragrances are ubiquitous and a part of many domestic and occupational products intended for hand exposure. The present review is based on a systematic literature research using both a manual and a Medline based search. The search identified 39 studies, including epidemiological patch test studies, general population patch test studies, case studies, and studies of occupational groups. The published data indicate a possible association between fragrance allergy and hand eczema. In future studies, a more detailed exposure assessment is needed, combined with patch test studies among patients with hand eczema tested with relevant fragrance allergens, as well as experimental control exposure studies to specific fragrance allergens on the hands. As exposures to fragrances on the hands are often simultaneous exposures to irritants, this combined exposure approach needs to be considered.

Adult↗

A unique rhodium-catalyzed rearrangement process: isomerization of an alkyne to a 1,3-diene with concomitant migration of a formyl group. An expeditious route to dienals from readily available 4-alkynals.

In CH2Cl2, [Rh(BINAP)]BF4 catalyzes the isomerization of 4-alkynals to dienals with excellent regio- and stereoselectivity; this new process compares favorably with previously reported methods for the synthesis of this class of compounds; a possible pathway for this unusual rearrangement is provided.

Aldehydes↗

Determination of synthetic musk compounds in sewage biosolids by gas chromatography/mass spectrometry.

A review of sewage sludge regulations and land application practices by the United States National Research Council (2002) recommended development of improved analytical techniques to adequately identify and quantify new chemical contaminants, such as synthetic musk compounds in Class A sewage sludge (i.e., biosolids). This prompted the development of a rugged analytical method using gas chromatography coupled to mass spectrometry to detect this group of organic pollutants in biosolids. In this paper, the term "biosolids" is used interchangeably with "sewage sludge", which is defined in the regulations and used in the statue (Clean Water Act). Samples of Class A biosolids obtained from sewage treatment plants in Los Angeles, California, the City of Las Vegas, Nevada, and also in the form of a commercial fertilizer, were extracted using pressurized liquid extraction technique, subjected to gel permeation chromatography clean-up, and analyzed by GC/MS using the selected ion monitoring mode. The method developed has the potential to detect synthetic musk compounds in complex matrices, may provide accurate data useful in human health and environmental risk assessment, and may be useful in determining the efficacy of municipal sewage treatment plants for removing synthetic musk compounds.

Chemical Fractionation↗

The frequency of fragrance allergy in a patch-test population over a 17-year period.

Fragrances are widely encountered in our daily environment and are known to be a common cause of allergic contact dermatitis. We have reviewed our patch test data from 1980 to 1996 to establish whether the pattern of fragrance allergy has changed with time. During this period, 25,545 patients (10,450 male, 15,005 female) were patch tested with the European standard series. The mean annual frequency of positive reactions to the fragrance mix was 8.5% in females (range 6.1-10.9) and 6.7% in males (range 5.1-12.9). Females were 1.3 times more likely to be allergic to fragrance (P < 0.001, 95% confidence interval, CI 1.17-1.41). Males with fragrance allergy were older than females by 5.6 years (mean age 48.2 vs. 42.6 years; P < 0.001, 95% CI 3.9-7.3). The incidence of a concomitant positive patch test to balsam of Peru in fragrance-sensitive patients showed wide variation, suggesting that it is not a reliable marker of fragrance allergy. There was a positive correlation between the isomers isoeugenol and eugenol. Oak moss remained the most common overall allergen throughout the study, positive in 38.3% of females and 35.6% of males who were tested to the constituents of the fragrance mix. During the period of the study the incidence of positive tests to oak moss increased by 5% yearly (P = 0.001, 95% CI 2.2-8.7). The frequency of allergic reactions to eugenol and geraniol remained relatively constant. Isoeugenol and alpha-amyl cinnamic aldehyde sensitivity increased and hydroxycitronellal showed a slow decline. There was a striking reduction in the frequency of sensitivity to cinnamic aldehyde (by 18% yearly; P < 0.001, 95% CI 14.3-21.0) and cinnamic alcohol (by 9% yearly; P < 0.001, 95% CI 5.2-12.9); these are now uncommon fragrance allergens. These data show temporal trends which may reflect the frequency of population exposure to individual fragrances.

Acrolein↗

Changes in the pattern of sensitization to common contact allergens in denmark between 1985-86 and 1997-98, with a special view to the effect of preventive strategies.

The objective of the present study is to describe any changes in the prevalence of sensitization to common contact allergens in patch-tested patients over a 12-year period. Attention is given to possible effects of preventive strategies introduced in Denmark regarding nickel and chromate sensitization during that period, and particular areas of concern are identified. Members of the Danish Contact Dermatitis Group collected patch-test results from consecutive eczema patients as well as information about exposures and demographic variables over a 6-month period in 1985-86. The investigation was repeated in 1997-98 in the same clinics, at the same time of year, using identical methods and patch-test substances, including nickel sulphate 5%, potassium dichromate 0.5% and fragrance mix 8%. Nickel was the most common contact allergen in both study periods, followed by the fragrance mix. In children 0-18 years of age, the frequency of nickel allergy decreased from 24.8% in the first study period to 9.2% in the second study period (P < 0. 0008). Fragrance mix allergy doubled in frequency from 4.1% in 1985-86 to 9.9% in 1997-98, an increase that affected all age groups. Contact allergy to potassium dichromate decreased significantly from 3.0% in the first period to 1.2% in the second period (P = 0. 001). The decrease was seen in both sexes and was most pronounced among those of working age. No other significant changes were found in the frequency of sensitization to common allergens over the 12-year observation period.

Adolescent↗

Fragrance allergy.

Explore the source record for details and available documents.

Dermatitis, Allergic Contact↗

The significance of fragrance mix, balsam of Peru, colophony and propolis as screening tools in the detection of fragrance allergy.

BACKGROUND: Patch testing to fragrances is an important step in the diagnosis of fragrance allergy. OBJECTIVES: To determine the usefulness of adding propolis to the European standard series to test for fragrance allergy. PATIENTS AND METHODS: A total of 2660 consecutive patients were patch tested with a standard patch test series; 747 suspected of fragrance allergy were tested further with a special fragrance series. RESULTS: The positive results to the standard series in 2660 patients were: fragrance mix 243 (9.1%), Myroxylon Pereirae [balsam of Peru] 144 (5.4%), colophony 32 (1.2%); these fragrance mixtures are used as screening substances for fragrance allergy in the European standard series. Propolis, also known as bee's glue, was also an important allergen in this locally revised standard series (n = 35, 1.3%). Positive reactions to the aforementioned allergens were associated significantly among each other (P < 0.01, chi2-test) and did not differ between the sexes. The primary locations of dermatitis in patients with a positive test to one or more fragrance allergens (n = 162) among those suspected of fragrance allergy (n = 747) were: face 46.9%, hands 23.5%, neck 17.9%, axillae 12.3%; 92 of the 747 patients suspected of fragrance allergy had positive skin tests to the special fragrance series comprising the eight constituents of the fragrance mix (most frequent: isoeugenol 5.4%, oakmoss absolute 5.0%, eugenol 2.5%) and 14 other fragrance allergens (most frequent: clove oil 1.6%, lemon grass oil 0.8%, cedar wood oil 0.7%). The additional value of propolis as another screening substance for fragrance allergy in these patients was low. The likelihood of a reaction to one or more of the extra fragrance allergens increased with the number of reactions to fragrance screening allergens in the standard series. CONCLUSIONS: The number of positive reactions to fragrance screening allergens in a standard patch test series may be used as a rule of thumb for predicting a positive outcome of a more detailed testing to fragrances. Propolis is an important allergen in its own right but its value as a screening substance for fragrance allergy is limited.

Adult↗

Allergy to lichen acids in a fragrance.

A 48-year-old clerical officer with a recurrent facial eruption had positive patch test reactions to nickel, fragrance mix and lichen acid mix. On testing to individual ingredients of fragrance mix and lichen acid mix, she had 2+ reactions to oak moss, which is thought to be the main allergen in fragrance mix, and to usnic acid, which is one of a number of lichen acids comprising oak moss. Avoidance of fragrance use resulted in clearing of the eruption but, subsequently, an acute vesicular flare on her face and hands occurred after exposure to lichen on garden shrubs.

Allergens↗

Prevalence of delayed hypersensitivity to the European standard series in a self-selected population.

There are limited reports of the prevalence of positive reactions in healthy adults to patch tests with standard allergens; there are no recent comprehensive studies from Australia. Healthy adult volunteers (n = 219) from the Western Australian community were patch tested using the European standard series of allergens. Seventy-seven (35%) reacted to at least one allergen, positive patch tests being most prevalent to nickel sulfate (20%), potassium dichromate (9%), cobalt chloride (6%) and fragrance mix (4%). Prevalence of positive patch tests to nickel and chromate was higher than that reported for another healthy population, which may stem from self-selection of volunteers or geographical differences, including extent of exposure to allergens.

Adolescent↗

Dermatitis following systemic prednisolone: patch testing with prednisolone eye drops.

Although positive reactions to topical corticosteroids can occur in over 1% of a patch-test population, systemic reactions to oral corticosteroids are uncommon. A 45-year-old woman who gave a clear history of the generalization of a cutaneous eruption following oral prednisolone was positive on patch testing using prednisolone eye drops.

Administration, Oral↗

In this issue

Explore the source record for details and available documents.

Journal Article↗

Patch testing in children, adults, and the elderly: influence of age and sex on sensitization patterns.

Patch testing was done on 2776 consecutive patients (76.5% female) with a locally revised standard series of 34 contact allergens and the results analyzed for age- and gender-specific differences. At least one positive epicutaneous test reaction occurred in 48.9% of patients. Nickel (20.9%), ethylmercuric chloride (13.2%), thimerosal (11.8%), fragrance mix (9.3%), metallic mercury (8.9%), palladium (5.8%), balsam of Peru (3.8%), copper (3.7%), cobalt (3.3%), and chromium (2.3%) were the 10 most important sensitizers. The following tested allergens with sensitization rates of more than 1% were not part of the usual standard series: ethylmercuric chloride, metallic mercury, copper, propolis (1.3%), propylene glycol (1.0%). Reactions to nickel, cobalt, and palladium, but not to chromium, were significantly more abundant in females (p < 0.002, chi-squared test). The overall sensitization rate was highest in children less than 10 years old (62%) and decreased steadily, to be lowest among patients more than 70 years old (34.9%). The rate of positive reactions to nickel and thimerosal decreased with age, while fragrance mix and metallic mercury stayed at the same level through all age groups.

Adolescent↗

Tolerance profile of a sterile moisturizer and moisturizing cleanser in irritated and sensitive skin.

BACKGROUND: This study evaluates the tolerance of preservative free sterile cleanser and sterile moisturizer in irritated and sensitive face skin. MATERIALS AND METHODS: An exploratory, open-label study using the cleanser and the moisturizer in combination was performed with 98 patients with a documented history of allergic contact dermatitis. The 2 products could each be used once or twice daily for 28 days. The assessment parameters at baseline and end of treatment (day 28) included the intensity of erythema, dryness/scaling by the investigator and subjective signs (burning, pruritus and stinging), according to a defined 4-point scale (absent to severe). In addition, a global assessment of the change from baseline and the overall tolerance of the products were performed by the investigator at the end of treatment. RESULTS: Ninety-four patients were included for the efficacy analysis and 96 patients for the safety analysis. At baseline, a majority of patients expressed some degree of erythema (63%), and dryness/scaling (56%). Fewer patients experienced subjective signs at baseline (44%). At the end of treatment, the results showed a statistically significant improvement of all the objective signs of irritated skin (P = .0001, Mac Nemar test), as well as the subjective signs of sensitive skin (P < 0.02). This was confirmed by the overall investigator assessment, showing an excellent or good response in 90% of the patients. In the safety analysis, 1 patient developed contact allergy to 1 ingredient of the test products (carbomer), and 3 patients exacerbated their dermatitis. CONCLUSION: Taken together, these results suggest that adequately formulated cosmetics might reduce both irritated and sensitive skin, with clinical improvement of dryness, erythema and stinging.

Adult↗

Accuracy of questions related to allergic contact dermatitis.

BACKGROUND: The ability of a physician to select individuals likely to benefit from patch testing depends on his or her ability to interpret responses to enquiries related to contact allergy. The significance of such responses to questions of nickel, fragrance and colophon allergy is unclear. OBJECTIVE: The specificity, sensitivity and predictive value of questions relating to nickel, fragrance and colophony allergy were determined. METHOD: A total of 258 patients attending for routine patch testing were questioned about skin reactions to nickel, fragrances and Elastoplast (Smith and Nephew Healthcare, Hull, England). All subjects were then patch tested to nickel, fragrance mix, and colophony. Responses to questions were compared with patch test results. RESULTS: The sensitivity of questions relating to nickel, fragrance, and colophony was 82%, 49%, and 71%, respectively. The specificity of the same questions was 77%, 79%, and 90%; the positive predictive value was 54%, 46% and 29%, respectively. After adjustment to include clinical relevance, the sensitivity of nickel questions rose to 100%. CONCLUSION: These data permit greater understanding of the role of patient history in selection of patients for patch testing.

Allergens↗