Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “INTERFEROMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

A new radiographic procedure for obtaining correction factors of 3H-beta-self-absorption for quantitative tritium autoradiography.

A 3H-radiographic method based on the absorption of 3H-beta-particles by an overlying tissue section was established for obtaining correction factors of 3H-beta-absorption (c.f.s) on the cellular level for all kinds of sections in a simple and more precise way as possible with interferometry. Unlabelled paraffin or Araldite sections were mounted on a thin uniformly 3H-labelled section of resin, and autoradiographs were prepared. Grain densities of neuronal cell types and cell-free areas within and outside the paraffin or Araldite sections were evaluated in autoradiographs, where the exposure time or the thickness of the overlying histological section was varied. From these values c.f.s were calculated applying the Beer-Lambert law. It was shown that corresponding c.f.s determined with this new radiographic method correspond well with each other. However, they will only agree with those c.f.s obtained by interferometry, if relative c.f.s are compared. Since the c.f.s are quite sensitive to the section thickness, a new parameter phi was introduced, which helps to assess whether the microtome used works exactly. Generally, the method presented can be used on the cytological level as well as for whole areas in every other autoradiographic study.

Animals↗

Increased tear evaporation in a patient with ectrodactyly-ectodermal dysplasia-clefting syndrome.

PURPOSE: To describe the tear function and ocular surface disorders in a patient with ectrodactyly-ectodermal dysplasia-clefting (EEC) syndrome. METHODS: Routine ophthalmic examinations were performed, including slit-lamp biomicroscopy, anterior segment photography including transillumination photos of the lids, Schirmer tests I and II, tear film break-up time (BUT) assessment, corneal fluorescein staining, DR-1 tear film lipid layer interferometry, and tear evaporation rate measurements. RESULTS: Slit-lamp examination revealed conjunctival hyperemia, superficial punctate keratopathy, and corneal leucoma with neovascularization. Although the Schirmer test values were within normal limits, the BUT value was 0 s in both eyes. Transillumination of the lids showed the absence of meibomian glandular structures. DR-1 tear film lipid layer interferometry results were dry eye grade 5 with an irregular tear film, areas of corneal surface exposure, and several dry spots. The tear evaporation rate was elevated and was measured as 6.98 x 10(-7) g/cm2 per second (normal, 4.1 +/- 1.4 x 10(-7) g/cm2 per second). CONCLUSION: The ocular surface disorder and shortened BUT in EEC syndrome were attributed to the absence of meibomian glands, leading to lipid layer deficiency in the tear film with a concomitant increase in tear evaporation.

Adolescent↗

Epithelial internalization of superparamagnetic nanoparticles and response to external magnetic field.

Superparamagnetic magnetite nanoparticles (MNP) coated with silica were synthesized and chronically implanted into the middle ear epithelial tissues of a guinea pig model (n=16) for the generation of force by an external magnetic field. In vivo limitations of biocompatibility include particle morphology, size distribution, composition and mode of internalization. Synthesis of MNP was performed using a modified precipitation technique and they were characterized by transmission electron microscopy, X-ray diffractometry and energy dispersive spectroscopy, which verified size distribution, composition and silica encapsulation. The mechanism for internalizing 16+/-2.3 nm diameter MNP was likely endocytosis, enhanced by magnetically force. Using sterile technique, middle ear epithelia of tympanic membrane or ossicles was exposed and a suspension of particles with fluoroscein isothiocyanate (FITC) label applied to the surface. A rare earth, NdFeBo magnet (0.35 T) placed under the animal, was used to pull the MNP into the tissue. After 8 days, following euthanasia, tissues were harvested and confocal scanning laser interferometry was used to verify intracellular MNP. Displacements of the osscicular chain in response to an external sinusoidal electromagnetic field were also measured using laser Doppler interferometry. We showed for the first time a physiologically relevant, biomechanical function, produced by MNP responding to a magnetic field.

Animals↗

Determination of elastic, anelastic, and piezoelectric coefficients of piezoelectric materials from a single specimen by acoustic resonance spectroscopy.

We describe an advanced methodology to determine all the independent elastic-stiffness coefficients Cijkl, the associated internal frictions Qijkl(-1), and piezoelectric coefficients eijk of piezoelectric materials from a single monocrystal specimen using resonant-ultrasound spectroscopy with laser-Doppler interferometry. The mechanical-resonance frequencies of a piezoelectric solid depend on all of the elastic and piezoelectric coefficients, and their accurate measurement allows one to determine the elastic and piezoelectric coefficients simultaneously. Resonance-peak-width measurements yield the internal-friction tensor. Successful determination requires correct vibration-mode identification for the observed resonance frequencies. This is achieved unambiguously by measuring deformation distributions on the vibrating-specimen surface with laser-Doppler interferometry and comparing them with calculated displacement distributions. The methodology is applied to lithium niobate (LiNbO3) and langasite (La3Ga5SiO14) crystals.

Journal Article↗

Molecular dynamics simulations of a hydrated protein vectorially oriented on polar and nonpolar soft surfaces.

We present a collection of molecular dynamics computer simulation studies on a model protein-membrane system, namely a cytochrome c monolayer attached to an organic self-assembled monolayer (SAM). Modifications of the system are explored, including the polarity of the SAM endgroups, the amount of water present for hydration, and the coordination number of the heme iron atom. Various structural parameters are measured, e.g., the protein radius of gyration and eccentricity, the deviation of the protein backbone from the x-ray crystal structure, the orientation of the protein relative to the SAM surface, and the profile structures of the SAM, protein, and water. The polar SAM appears to interact more strongly with the protein than does the nonpolar SAM. Increased hydration of the system tends to reduce the effects of other parameters. The choice of iron coordination model has a significant effect on the protein structure and the heme orientation. The overall protein structure is largely conserved, except at each end of the sequence and in one loop region. The SAM structure is only perturbed in the region of its direct contact with the protein. Our calculations are in reasonably good agreement with experimental measurements (polarized optical absorption/emission spectroscopy, x-ray interferometry, and neutron interferometry).

Binding Sites↗

Alteration of the ocular surface with recurrence of granular/avellino corneal dystrophy after phototherapeutic keratectomy: report of five cases and literature review.

PURPOSE: To study the changes in ocular surface findings with recurrence after phototherapeutic keratectomy (PTK) in patients with Avellino and granular dystrophy. DESIGN: Observational case series. PARTICIPANTS: Five eyes of five patients with recurrent granular/Avellino corneal dystrophy after PTK seen at Kobe Kaisei Hospital were studied. INTERVENTION: The patients underwent routine ophthalmic examinations, corneal sensitivity measurements, tear film breakup time (BUT), Schirmer test, tear film lipid layer interferometry, and conjunctival impression cytology. MAIN OUTCOME MEASURES: The alterations of clinical features, tear function, and conjunctival impression cytology parameters with a recurrence after PTK were investigated. RESULTS: The average pre-PTK corneal sensitivity and tear film breakup time were low in all five patients. Tear film lipid layer interferometry grade and conjunctival squamous metaplasia displayed higher grades before PTK. All of these parameters improved gradually after PTK and were maintained until a recurrence, which was associated with further worsening of the corneal sensitivity, tear function, and impression cytology parameters. CONCLUSIONS: Although PTK improves the ocular surface health in granular/Avellino corneal dystrophies, recurrence of the initial dystrophy is associated with decline of the ocular surface health parameters. Our findings also suggest that corneal epithelium is most probably involved in the recurrence of the disease process in Avellino/granular corneal dystrophy.

Aged↗

Flattening of central corneal curvature with intrastromal corneal rings of increasing thickness: an eye-bank eye study.

Intrastromal Corneal Rings (ICRs) have been demonstrated to flatten human corneas when implanted into peripheral intrastromal corneal channels. To study the flattening effect, ICRs of increasing thickness, 0.26, 0.31, 0.36, 0.41, and 0.46 mm, were placed into oversized (approximately 70% depth) intrastromal channels in 38 eye-bank eyes. Each of 33 eyes received one ICR; the mean change in dioptric data was obtained for four meridians using an intraoperative photokeratoscope. Intrastromal corneal rings of increasing thickness resulted in corneal flattening of 3.8 +/- 1.1, 4.9 +/- 0.6, 5.2 +/- 1.1, 5.3 +/- 1.9, and 7.3 +/- 1.6 diopters, respectively, for keratoscope mire 2. One of each size ICR was placed into one of five additional eye-bank eyes; the degree of flattening measured by laser holographic interferometry was 1.8, 2.9, 5.5, 4.7, and 10.1 diopters, respectively, for the central 6 mm corneal zone. These results indicate that the ICR provides a fairly linear flattening relationship over the range of thicknesses tested. Additionally, laser holographic interferometry wave unit maps of preoperative and postoperative corneas demonstrated that the ICR tends to preserve positive corneal asphericity if present preoperatively.

Anthropometry↗

Remote sensing: searching for new islands in sea ice.

Tobias Island, discovered in 1993 by the German research vessel RV Polarstern, is a system of low-lying banks and shoals hidden in sea ice 70 km off the northeastern coast of Greenland. Here we use satellite radar interferometry and airborne laser scanning to show that this island is 2 km long and 35 m high --- much larger than was originally reported. We have also been able to pinpoint the exact location of a stable area where a new group of small islands may be hidden. This demonstrates that satellite radar interferometry is an effective tool for finding ice-covered islands as well as for mapping them.

Journal Article↗

A comparison between laser interferometric measurement of fundus pulsation and pneumotonometric measurement of pulsatile ocular blood flow. 2. Effects of changes in pCO2 and pO2 and of isoproterenol.

PURPOSE: We have shown in the companion paper that, under baseline conditions, there is a high degree of association between laser interferometrically measured fundus pulsation amplitude (FPA) and pneumotonometrically measured pulse amplitude (PA) and pulsatile ocular blood flow (POBF). The present study investigated the effect of high pCO2, of high pO2 and of isoproterenol on POBF as assessed with laser interferometry and pneumotonometry. METHODS: Pneumotonometry and laser interferometry were performed in young healthy subjects during breathing of 100% O2 (n = 10; hyperoxia) and of 5% CO2 + 95% air (n = 8; hypercapnia). In addition these parameters were studied during stepwise increasing doses of isoproterenol, a beta-receptor agonist (n = 8). RESULTS: Inhalation of 5% CO2 + 95% air increased FPA (24 +/- 12%, p < 0.001), PA (26 +/- 13%, p < 0.001) and POBF (15 +/- 8%, p = 0.002). Inhalation of 100% O2 decreased FPA (-5 +/- 7%, p = 0.027), but did not change PA or POBF. The effect of 100% O2 inhalation on FPA in the optic disc was more pronounced (-11% to -20%) than in the macula. Isoproterenol caused a dose-dependent increase in FPA, PA and POBF (p < 0.001). The association between the induced changes in FPA and PA or POBF was highly significant. CONCLUSIONS: The present study shows that FPA can be taken as a valid relative measure of pulsatile choroidal blood flow. Our results in the optic disc indicate that FPA at the neuroretinal rim and at the cup is influenced by retinal and choroidal circulation.

Adrenergic beta-Agonists↗

Radiation-pressure cooling and optomechanical instability of a micromirror.

Recent table-top optical interferometry experiments and advances in gravitational-wave detectors have demonstrated the capability of optical interferometry to detect displacements with high sensitivity. Operation at higher powers will be crucial for further sensitivity enhancement, but dynamical effects caused by radiation pressure on the interferometer mirrors must be taken into account, and the appearance of optomechanical instabilities may jeopardize the stable operation of the next generation of interferometers. These instabilities are the result of a nonlinear coupling between the motion of the mirrors and the optical field, which modifies the effective dynamics of the mirror. Such 'optical spring' effects have already been demonstrated for the mechanical damping of an electromagnetic waveguide with a moving wall, the resonance frequency of a specially designed flexure oscillator, and the optomechanical instability of a silica microtoroidal resonator. Here we present an experiment where a micromechanical resonator is used as a mirror in a very high-finesse optical cavity, and its displacements are monitored with unprecedented sensitivity. By detuning the laser frequency with respect to the cavity resonance, we have observed a drastic cooling of the microresonator by intracavity radiation pressure, down to an effective temperature of 10 kelvin. For opposite detuning, efficient heating is observed, as well as a radiation-pressure-induced instability of the resonator. Further experimental progress and cryogenic operation may lead to the experimental observation of the quantum ground state of a micromechanical resonator, either by passive or active cooling techniques.

Journal Article↗

Characterization of angiotensin-II effects on cerebral and ocular circulation by noninvasive methods.

AIMS: The role of the renin-angiotensin-system (RAS) in the cerebral and ocular circulation is still a matter of controversy. In vitro and animal data lead to partially contradicting results. However, direct investigation of locally generated angiotensin II (Ang II) in humans is not possible in vivo. Hence, we hypothesised that it might be possible to characterize local effects of Ang II by comparing systemic and local haemodynamic parameters during exogenous Ang II infusion. METHODS: In a placebo-controlled, double-blind, two-way cross over study blood flow velocities in the middle cerebral and the ophthalmic artery and ocular fundus pulsations were measured during stepwise increasing doses of Ang II in 10 healthy subjects. Blood flow velocities were assessed by Doppler sonography, fundus pulsation amplitudes (FPA), which estimate local pulsatile ocular blood flow were measured by laser interferometry. Additionally, systemic blood pressure and pulse rate were measured. RESULTS: Ang II dose-dependently decreased resistive index (RI) and increased mean flow velocities (MFV) in both arteries. Fundus pulsation amplitude was dose-dependently decreased by Ang II, whereas mean arterial pressure (MAP) was significantly increased. Pulse pressure amplitude (PPA) was not affected by Ang II administration. There was a high degree of correlation between changes in RIs and the analogously calculated PPA/systolic blood pressure during Ang II infusion, which indicates that the changes in RI after Ang II administration can be attributed to changes in systemic haemodynamics. Calculation of total local ocular blood flow from fundus pulsation amplitudes and changes in flow pulsatility in the ophthalmic artery further argue against significant blood flow changes after Ang II administration. CONCLUSIONS: Interpretation of data from Doppler sonography and laser interferometry must be done very carefully when concomitant changes in systemic haemodynamics occur. RI cannot necessarily be taken as an index of distal vascular resistance in these cases and changes in MFV can be caused by changes in vessel diameter or in blood flow. Moreover, FPA cannot be taken as a measure of ocular blood flow if no additional data on flow pulsatility are available. The combination of our systemic and local haemodynamic data indicates that cerebral and ocular circulation are comparably insensitive to changes in local Ang II concentrations. Fundus pulsation and blood flow velocity measurements indicate that neither choroidal nor optic nerve head blood flow are significantly affected by administration of Ang II.

Adult↗

Primary tissue failure of bioprostheses: new evidence from in vitro tests.

BACKGROUND: Primary tissue failure, which is mainly caused by calcification, is still the limiting factor in the long-term outcome of heart valve bioprostheses. Even though the precise nature of this process is not fully understood, in vitro tests have been developed to reproduce and predict calcification for individual bioprostheses. METHODS: In vitro calcification testing was performed by using an accelerated pulsatile valve tester which was adapted for testing stented as well as stentless bioprostheses with physiological fluid dynamics. A total of 84 bioprostheses (porcine, pericardial and stentless porcine of different manufacturers) were cyclically loaded at a test rate of 300/min at 37 degrees C within a rapid calcification fluid with CaxP = 130(mg/dl)2 at pH 7.4. Calcification was assessed by microradiography after 12 x 10(6) cycles. In a previous step, holographic interferometry was performed to identify irregularities of valve leaflets in order to predict later calcification. Selected specimens of calcified bioprostheses underwent histology, transmission (TEM) and scanning (SEM) electron microscopy. Tissue mineralization was investigated by coupling SEM, electron microprobe analysis (EMPA) and X-ray powder diffraction (XRPD) methods. RESULTS: For all tested bioprostheses, a significant calcification was achieved within 4 to 6 weeks of ongoing testing, and the degree of calcification increased with time. A significant correlation between calcification and leaflet irregularities (detected by holographic interferometry) was found (r = 0.80, p = 0.001). Calcification varied between individual bioprostheses, and significant differences were detected for different groups (calculated as percentage of total leaflet area, mean +/- SD): porcine stented (37.3 +/- 12.0%), bovine stented (23.0 +/- 8.9%), porcine stentless (16.2 +/- 7.6%). Histological and ultrastructural investigation showed intrinsic calcification involving both the spongiosa and fibrosa with collagen fibrils, interfibrillar spaces and cells as early sites of calcification. There was clear evidence of apatite crystallization, and observations made with in vitro calcification were quite similar to those occurring with in vivo implanted bioprostheses. CONCLUSION: In vitro tests can reproduce intrinsic calcification of bioprostheses even in the absence of viable biologic host factors. Moreover, degree and sites of calcification have become predictable. This enables the development and evaluation of bioprostheses with reduction of animal experiments. From our results obtained with a broad range of available bioprostheses, stented bovine and stentless porcine valves seem to be superior to conventional stented porcine bioprostheses with regard to leaflet calcification.

Animals↗

Morphology of high-luminosity compact radio sources.

High-dynamic range imaging and monitoring with very-long-baseline interferometry reveal a rich morphology of luminous flat-spectrum radio sources. One-sided core-jet structures abound, and superluminal motion is frequently measured. In a few cases, both distinct moving features and diffuse underlying jet emission can be detected. Superluminal motion seen in such sources is typically complex, on curved trajectories or ridge lines, and with variable component velocities, including stationary features. The curved trajectories seen can be modeled by helical motion within the underlying jet flow. The very-long-baseline interferometry properties of the superluminal features in the jet of 3C 345 and other similar sources can be explained by models invoking the emission from shocks, at least within the vicinity of the compact core. Inverse-Compton calculations, constrained by x-ray observations, yield realistic estimates for the physical conditions in the parsec-scale jet. There is evidence for a transition region in this source beyond which other factors (e.g., plasma interactions and nonsynchrotron radiation processes) may become prominent. Multifrequency and polarization imaging (especially at high frequencies) are emerging as critical tools in testing model predictions.

Journal Article↗

Influence of diffuse luminance flicker on choroidal and optic nerve head blood flow.

PURPOSE: In the retina there is general agreement that blood flow adapts in response to different conditions of light and darkness including diffuse luminance flicker. By contrast, regulation of choroidal blood flow in response to different light conditions is still a matter of controversy. Thus, we investigated the effect of diffuse luminance flicker on choroidal and optic nerve head blood flow. METHODS: In a group of 14 healthy volunteers, choroidal blood flow and ocular fundus pulsation amplitude were assessed with laser Doppler flowmetry and laser interferometry, respectively. Measurements were done before, during and after stimulation with diffuse luminance flicker. Furthermore, the response of optic nerve head blood flow (ONHBF) to flicker stimulation was measured. Flicker stimuli were generated by a Grass PS2 photostimulator, stimulating at a frequency of 8 Hz. Flicker light consisted of light flashes at a wavelength below 550 nm and produced a retinal irradiance of 140 microW/cm( 2). Blood pressure and pulse rate were measured non-invasively. Paired t-test was used for statistical analysis. RESULTS: ONHBF increased immediately after onset of flicker stimulation. The maximum increase in ONHBF was 30% +/- 10% (mean +/- SEM, p < 0.008). Both choroidal perfusion parameters were only slightly increased during flicker stimulation, by 2 +/- 2% (laser Doppler flowmetry, p < 0.5) and by 4 +/- 1% (laser interferometry, p < 0.12). After the end of stimulation all values returned to baseline levels. CONCLUSION: Our study clearly demonstrates that diffuse luminance flicker increases optic nerve head blood flow. In contrast, increased neural activity in the retina has no effect on choroidal blood flow. Thus, choroidal blood flow appears to be largely independent of alterations in retinal metabolism.

Choroid↗

Initial tooth displacement in vivo as a predictor of long-term displacement.

In the past, the dry skull has been used as a hypothetical model to test initial orthodontic and orthopaedic force systems. However, the question as to whether this hypothetical model can be used as a predictor of long-term displacements in vivo remains unanswered. In this study, an attempt was made to compare initial tooth displacement with the long-term effect after application of the force system for a longer period of time, in six adult dogs. Tooth displacement was obtained by applying a force by means of a coil spring (push) system. Following application of a force of 50 g in the first series (n = 3) and 80 g in the second series (n = 3), initial displacements were registered by means of speckle interferometry. The long-term displacement was registered by means of standardized cephalometry in the same dog by leaving the force system in place for 5 weeks. The mean values of the displacement vectors of the second premolars in the six dogs were compared. A paired t-test revealed no significant differences between the initial and long-term displacements in any of the dogs. The results show that both groups of measurements belong statistically to the same sample and that initial tooth displacement measured by means of speckle interferometry is a valuable predictor for forecasting long-term displacement in vivo after 5 weeks.

Animals↗

Optical system for double-biprism electron holography.

A novel system of electron interferometry and holography using two electron biprisms has been developed. The first biprism is installed in the image plane of the objective lens and the second one is set behind the first magnifying lens, inside the shadow area of the first biprism. The system can independently control two important parameters for interferograms and holograms, the fringe spacing and interference width. Thus, it gives us more flexibility on performing electron interferometry and holography. The good performance of the system was demonstrated using a 1MV field-emission electron microscope. We introduce a variety of optical set-ups for the system and explain the advantages of each set-up in detail, with experimental results.

Journal Article↗

Displacement pattern of the normal pars flaccida in the gerbil.

OBJECTIVE: The aim of the current study was to assess the mechanical stiffness properties of the normal pars flaccida and to compare the results with those obtained in earlier studies on the pars tensa. BACKGROUND: Postinflammatory changes such as retraction pockets and cholesteatoma develop in the pars flaccida as well as in the pars tensa of the tympanic membrane. In these authors' previous experimental studies, stiffness changes are shown to develop early in the pars tensa in response to purulent otitis media and otitis media with effusion. These changes are suggested to be precursors to a later development of retraction pockets and cholesteatoma. In the clinical situation, retraction pockets are often found in the pars flaccida only. This study will establish the stiffness properties of the normal pars flaccida and form a base for forthcoming studies of the pars flaccida in response to otitis media with effusion and purulent otitis media, as well as retraction pocket formation and cholesteatoma. METHODS: A measure for the mechanical stiffness properties of the normal pars flaccida in the gerbil was assessed as its displacement for a given transtympanic pressure. The method used was moiré interferometry, which is a noncontacting optical technique to measure the shape of the surface of an object. RESULTS: The displacement of the pars flaccida was a nonlinear and asymmetric function of pressure. The displacement per pressure unit rose steeply at low middle ear pressures to level out and reach a steady state at higher pressures. The displacement versus pressure characteristics for the pars flaccida strongly differed from those of the pars tensa. The pars tensa seemed more elastic. CONCLUSION: Reference values for displacement versus pressure characteristics of the normal gerbil pars flaccida were obtained using a moiré interferometry method. The mechanical stiffness properties of the normal pars flaccida were strongly different from those of the pars tensa.

Animals↗

Phase recovery and lensless imaging by iterative methods in optical, X-ray and electron diffraction.

Thomas Young's quantitative analysis of interference effects provided the confidence needed to revive the wave theory of light, and firmly established the concept of phase in optics. Phase plays a similarly fundamental role in matter-wave interferometry, for which the field-emission electron microscope provides ideal instrumentation. The wave-particle duality is vividly demonstrated by experimental 'Young's fringes' using coherent electron beams under conditions in which the flight time is less than the time between particle emission. A brief historical review is given of electron interferometry and holography, including the Aharonov-Bohm effect and the electron Sagnac interferometer. The simultaneous development of phase-contrast imaging at subnanometre spatial resolution has greatly deepened our understanding of atomic processes in biology, materials science and condensed-matter physics, while electron holography has become a routine tool for the mapping of electrostatic and magnetic fields in materials on a nanometre scale. The encoding of phase information in scattered farfield intensities is discussed, and non-interferometric, non-crystallographic methods for phase retrieval are reviewed in relationship to electron holography. Examples of phase measurement and diffraction-limited imaging using the hybrid input-output iterative algorithm are given, including simulations for soft X-ray imaging, and new experimental results for coherent electron and visible-light scattering. Image reconstruction is demonstrated from experimental electron and visible-light Fraunhofer diffraction patterns. The prospects this provides for lensless imaging using particles for which no lenses exist (such as neutrons, condensates, coherent atom beams and X-rays) are discussed. These new interactions can be expected to provide new information, perhaps, for example, in biology, with the advantage of less damage to samples.

Algorithms↗