Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ear Protective Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

[Useful tools for prone position: ProneView and OPTI-GARD].

For prone position except for neurosurgery or cervical spinal surgery, head and neck are usually turned sideways on the pillow. This position has a risk of injuries to eyes, nose, lips, ears, or facial nerve and inducing neck pain after surgery. We introduce new tools to avoid these complications from prone position. The ProneView consists of a plastic helmet with a window for eyes, nose and mouth, a sponge to fit the face attached to the helmet, and a mirror to watch eyes, nose and lips. The OPTI-GARD is the glasses made by a sponge with a plastic windows to protect eyes. Using the ProneView and the OPTI-GARD together, patient's neck and head can be kept at neutral position with eyes, nose, lips, and ears being kept free from any pressure. In addition, we can check the position of the face easily by mirror. Therefore, the ProneView and the OPTI-GARD must be useful to decrease injuries to eyes, nose, lips, ears, and facial nerve, and neck pain in prone position.

Eye Protective Devices↗

Cochlear implantation of a Hungarian deaf and blind patient with discharging ears suffering from Behçet's disease.

A case is reported in which a Nucleus 22 channel intracochlear device was implanted a deaf/blind Hungarian adult with discharging ears suffering from Behçet's disease. Preconditioning surgery was employed three months prior to the implantation procedure to ensure a sterile, dry protected environment for the electrodes. One month after implantation, the patient exhibited excellent auditory discrimination capability at the time of the first switch on. We suggest that some deaf/blind individuals may serve as very good candidates for intracochlear implantation.

Adult↗

On the influence of the middle ear muscles upon changes in sound transmission.

The influence of artificially induced impedance changes on the frequency response of the middle ear has been investigated in three experienced listeners. The tensor-reflex has been simulated by application of positive and negative air-pressure to the outer ear canal. In this test-situation, the thresholdshift ("l) obtained is greatest in the surrounding of the first resonance of the middle ear ("l = 8 dB at 500 Hz). For bone-conduction, the effect is weaker by about 2 dB than for air-conduction. The change in sound transmission is constant for all SPL's and is mainly due to the impedance change of the middle ear. In contrast the influence of the stapedial reflex is strongly dependent on SPL. In the range between hearing-threshold and 70 dB (HL) the attenuation is only 2 dB below l kHz. At higher levels the attenuation may amount to 30 dB. Thus excitation of the cochlea remains nearly constant. We suppose that the intensity-dependent influence of the stapedius reflex on sound transmission is due to a change of the stapes motion. The regulating device works without considerable distortion but with an attack-time of about 100 ms. The phenomenon of conductive recruitment in otosclerosis is probably due to the lack of this regulating effect by the fixed stapes. One function of the stapedial reflex could be the protection of the ear from high amplitudes during phonation and shouting. Furthermore, because frequencies above l kHz are also attenuated, a protective function of the stapedial reflex in industrial noise exposure can be assumed.

Acoustic Impedance Tests↗

Substance distribution in a cochlea model using different pump rates for cochlear implant drug delivery electrode prototypes.

Several studies using animals have shown the protective effects of neurotrophic factors (NF) on spiral ganglion cells (SGC). This is of particular importance since the number of SGCs is considered to be among the factors defining the efficacy of cochlear implants. A device for local inner ear treatment is therefore of great interest. As described previously, we modified a Contour(TM) cochlear implant electrode, to examine the inbuilt canal to be used for fluid release [Paasche, G., Gibson, P., Averbeck, T., Becker, H., Lenarz, T., Stöver, T., 2003. Technical report: modification of a cochlear implant electrode for drug delivery to the inner ear. Otol. Neurotol. 24, 222-227]. In the present study, three different electrode prototypes with openings of the delivery channel at various locations along the electrode array were examined to determine distribution of dye in a cochlea model over time. We compared dye delivery with: (a) release of the dye at the tip, (b) release of the dye at the tip and the side of the electrode, and (c) release of the dye only at the side of the electrode (6 mm from the tip). A mechanical pump was used to drive the system at pump rates of 100, 10, and 1 microl/h. Dye concentration changes along the length of the whole cochlea were investigated. Mean values for all experimental conditions show that the distribution along the array is fastest with two outlets whereas the distribution via a single outlet at the side of the electrode array is not considered to be sufficient. The established experimental setup provides the possibility of investigating prototypes of a fluid based drug delivery system for the treatment of inner ear pathologies in combination with electrical stimulation.

Animals↗

Noise exposure during noninvasive ventilation with a helmet, a nasal mask, and a facial mask.

OBJECTIVE: To assess noise exposure during noninvasive ventilation (NIV) with different types of interface (helmet, nasal, and facial masks). SUBJECTS AND METHODS: Ten "naive" healthy volunteers underwent NIV at pressure support levels of 10 and 15 cmH2O with: (a) helmet, (b) helmet equipped with HME filters at the junctions between the helmet and the inspiratory and expiratory branches of the respiratory circuit, (c) nasal mask, and (d) facial mask. Noise intensity was assessed with a sound level meter by placing a microphone near the right ear. Noise intensity and degree of discomfort were also assessed subjectively with a visual analogue scale. RESULTS: Inside the helmet noise exceeded 100 dB. Noise intensity was poorly affected by pressure support level and unaffected by the presence of HME filters. During NIV with nasal or facial masks the noise did not exceed 70 dB (i.e., noise was not louder than the usual noise background in ICU). Subjective evaluation of noise intensity mirrored objective measurements; however, the presence of HME filters was associated with the feeling of less noise inside the helmet. The discomfort associated with the helmet did not significantly differ from that associated with the masks. CONCLUSIONS: NIV helmet is associated with significantly greater noise than nasal and facial masks, but is as comfortable as masks, at least in the short term. Medium- and long-term exposure to loud noise may potentially impair ear function and increase the patient's discomfort.

Adult↗

Simple new method of protecting the septum during oxygen delivery via a nasal canula.

Epistaxsis and crustation are common problems associated with long-term use of oxygen through nasal prongs in patients suffering from chronic obstructive pulmonary disease. The nasal prong can cause direct trauma to the septal mucosa. We describe a simple solution to this problem with use of the disposable ear tip used in tympanometry.

Catheterization↗

Analysis of posterior plagiocephaly: deformational versus synostotic.

Appropriate management of posterior plagiocephaly requires differentiation of occipitoparietal flattening caused by lambdoid synostosis from that caused by deformational forces. In a 2 1/2-year prospective study of 115 infants presenting with unilateral posterior cranial flattening, only one child had synostotic posterior plagiocephaly (lambdoid synostosis), whereas 114 infants had deformational posterior plagiocephaly. Deformational occipitoparietal flattening was more common on the right (61 percent) than on the left (30 percent), and minor contralateral frontal flattening was not unusual (52 percent). The ipsilateral ear was anteriorly displaced in virtually all infants (97 percent). Some infants had ipsilateral torticollis (19 percent); a few had contralateral torticollis (8 percent). Gender ratio was 3:1, male:female. A total of 114 infants with deformational posterior plagiocephaly were treated conservatively either by head positioning in the crib (n = 63) or with a molding helmet (n = 51). Outcome was assessed by pretreatment and posttreatment anthropometry on 53 of these infants, who were either positioned (n = 17) or helmeted (n = 36). Improvement occurred in 52 of 53 patients (mean follow-up 4.6 months), i.e., the difference in length between the long and short transcranial axis diminished in 52 infants (mean 1.2 to 0.7 cm), did not progress in any child, and was unchanged in one infant. At an average age of 10 months, posterior cranial symmetry was better in infants treated with a helmet (mean difference 0.6 cm) than in those managed by positioning (mean difference 1.0 cm) (p < 0.001). Age at initiation of helmet therapy (from 2 to 9 months) was unrelated to rate of improvement. In a 10-year retrospective study, the authors identified 12 infants who had an operation for posterior plagiocephaly. All but one had confirmed premature lambdoid fusion; thus, this condition accounted for 3.4 percent of all primary operations performed for craniosynostosis during this decade (n = 323). In retrospect, the physical findings of synostotic posterior plagiocephaly were not clearly different from those of deformational posterior plagiocephaly. Plain radiography was sometimes used to confirm the clinical diagnosis. Neither sutural narrowing, deep interdigitations, nor perisutural sclerosis indicated lambdoid synostosis. Computed tomography (CT) was necessary if the physical findings were suspicious for lambdoid synostosis or if plain films did not give a definitive diagnosis. Axial CT scans (n = 7) showed a symmetric forehead in all but one patient with lambdoid synostosis. CT studies also demonstrated that auricular position was indeterminate in synostotic posterior plagiocephaly, being anterior, posterior, or symmetric, whereas the ipsilateral ear was virtually always anterior in deformational posterior plagiocephaly.

Craniosynostoses↗

Predictive validity of a retrospective measure of noise exposure.

AIMS: To investigate the validity of measures of noise exposure derived retrospectively for a cohort of nuclear energy workers for the period 1950-98, by investigating their ability to predict hearing loss. METHODS: Subjects were men aged 45-65 chosen from a larger group of employees--assembled for a nested case-control study of noise and death from ischaemic heart disease--who had had at least one audiogram after at least five years' work. Average hearing loss, across both ears and the frequencies 0.5, 1, 2, and 4 kHz, was calculated from the last audiogram for each man. Previous noise exposure at work was assessed retrospectively by three hygienists using work histories, noise survey records from 1965-98, and judgement about use of hearing protection devices. Smoking and age at the time of the audiogram were extracted from records. Differences in hearing loss between men categorised by cumulative noise exposure were assessed after controlling for age, smoking, year of test, and previous test experience. RESULTS: There were 186 and 150 eligible subjects at sites A and B of the company respectively who were employed for an average of 20 years. Compared to men with less than one year's exposure to levels of 85dB(A) or greater, hearing loss was greater by 3.7 dB (90% CI -2.6 to 10.1), 3.8 dB (90% CI -2.6 to 10.3), 7.0 dB (90% CI 1.1 to 12.9) and 10.1 dB (90% CI 4.2 to 16.0) in the lowest to highest categories of cumulative noise exposure at site B. In contrast, at site A, the corresponding figures were -2.2 dB, -2.4 dB, -1.8 dB, and -4.4 dB, with no confidence interval excluding zero. CONCLUSIONS: Noise estimation at one site was shown to have predictive validity in terms of hearing loss, but not at the other site. Reasons for the differences between sites are discussed.

Age Factors↗

Protecting military convoys in Iraq: an examination of battle injuries sustained by a mechanized battalion during Operation Iraqi Freedom II.

Improvised explosive devices and mines pose a formidable threat to military convoys traveling in Iraq. This study evaluated battle injuries sustained by a mechanized battalion operating against this threat. The objective was to gain insight into injury profiles and prevention. In the period examined, 32 attacks injured 120 Marines, causing 188 injuries. Upper extremity and head injuries (70%) were common, whereas lower extremity injuries (11%) were rare (as expected, given the threat and the body areas exposed). Shoulder and axilla protectors may be beneficial, but lower arm and hand injuries remain difficult to combat. Ear injury was the most common single injury type (23%). Combat earplugs may reduce ear blast injuries. Eye injuries were uncommon (0.5%), likely because of ballistic eye protection. Injury to the torso (11%) was generally mild, because of body armor vests. The majority of wounds were minor, allowing > 80% of the injured Marines to return to duty.

Blast Injuries↗

Chemical countermeasures for the control of bacterial biofilms: effective compounds and promising targets.

The pathogenic nature of many infectious bacteria is enhanced by their ability to form surface-associated, protected communities known as "biofilms." Due to various factors, bacteria in biofilm communities display significantly greater resistance to traditional antimicrobial therapies than their planktonic brethren. This resistance complicates many common bacterial infections, resulting in recurrent ear infections, bacterial endocarditis, chronic lung infection in cystic fibrosis, infectious kidney stones, and surface infection of implanted medical devices. Owing to the serious nature of many biofilm-mediated infections and the near-complete dearth of effective strategies for treating them, efforts are underway to further understand the nature of bacterial infections involving biofilms and to discover and develop effective therapies to combat them. Particularly, several classes of chemical compounds have shown promise in combating biofilms when used in conjunction with traditional antimicrobials. The vast majority of these compounds exert their anti-biofilm properties through disruption of "quorum sensing," a common means of intercellular communication in bacterial communities that allows coordinated expression of virulence factors and facilitates formation of the oft-complex architecture of mature bacterial biofilms. Other new chemical entities are effective against biofilms without necessarily affecting quorum sensing. This review summarizes salient research in the development of effective chemical countermeasures for Gram-negative and Gram-positive bacterial infections involving biofilms.

Anti-Bacterial Agents↗

Noise, impulse noise, and other physical factors: combined effects on hearing.

In most of the epidemiologic studies conducted during the last 20 years, impulse noise caused increased risk of hearing loss in comparison to continuous noise with the same acoustical energy. The interaction between noise exposure (broadband at 100 dB(A)) and hand-arm vibration (125 Hz at 2 ms-2 acceleration level) has been proven for people having vibration-induced white finger symptoms. This interaction is evidenced as a permanent hearing loss. However, why the interaction is seen only in people with VWF is not known. The mechanisms may be related to individual susceptibility, and hypotheses are given on the role of the autonomous nervous system regulating the peripheral vascular reaction. Whole-body vibration (2-10 Hz, at 10 ms-2 level) seems to increase the TTS when noise (broadband at 90 dB(A)) is present. This effect is more pronounced at higher temperatures. The hypothermia protects hearing against the effects of noise in animal studies. The interaction between noise and temperature decrease seems obvious in animal studies. Exercise has both increased and decreased the TTS during noise exposure. The effects have been successfully explained as the depression of the stapedius reflex. Thus, less protection against noise is provided for the inner ear in exercise conditions. The increase of the blood temperature also has been suggested to increase noise-induced TTS during exercise. Electromagnetic fields have been found to cause acoustical interactions in the inner ear. Animal studies and human studies have given contradictory results on the effects of magnetic coil devices on hearing. The MR imaging devices produce noise levels of 82-93 dB, which is not sufficient to produce the risk of permanent hearing loss when short exposure durations are taken into consideration. More systematic research is needed with accurately defined electromagnetic characteristics to reveal the potential interactions. The interactions seem to exist, but relatively high levels and durations of exposure are needed to produce an observable effect on hearing. More investigations are still needed on the permanent hearing loss in humans caused by simultaneous long-term exposures to interacting environmental factors.

Animals↗

Ototraumatic effects of hard rock music.

Temporary and permanent shifts in auditory thresholds were found in 43 hard rock musicians and temporary shifts were also observed in some listeners. The threshold shifts involved all of the conventional puretone test frequencies. Custom-fitted polyvinyl chloride ear protectors were found to be effective in prevention of these noise-induced hearing losses.

Adult↗

Pediatric cochlear implantation: strategies to accommodate for head growth.

Accommodation for head growth presents one of several challenges unique to pediatric cochlear implantation. Given contemporary cochlear implant device designs, an electrode cable implanted at the age of 2 years must extend 2 to 3 cm as the head grows during childhood. In an initial study we found that model lead wires with redundant loops extended effectively when they were maintained within air-containing spaces such as the mastoid cavity or middle ear space. However, when looped leads traversed soft tissues overlying the parietal bone, they became embedded in fibrous tissue and did not extend. The present study evaluated three different configurations of expansile devices that were enclosed in polytetrafluoroethylene (PTFE) envelopes to deter fibrous ingrowth. This simple strategy was designed to ensure effective cable extension over cable pathlengths by protecting the redundant leads from any mechanically significant connective tissue ingrowth. Twelve such devices were implanted across the calvaria of four newly weaned piglets. Skull growth and changes in electrode dimensions were documented by sequential computed tomographic scans. At 3 months of age, cranial circumferences had increased substantially. Animals were then killed, the model cable extension appliances examined physically, and their implantation sites examined histologically. For all experimental devices, extension of redundant lead wires was satisfactory, and there was no mechanically significant invasion of fibrous connective tissue into the PTFE envelope. This indicates that enclosure of excess lead wire within a PTFE envelope may be an effective means of inhibiting fibrous ingrowth. This strategy should prove useful for ensuring effective electrode cable extension in cochlear implants applied in young children.

Animals↗