At least 793 records · Page 44Linked to original sources

Traumatic anterior dislocation of the hip associated with ipsilateral femoral shaft fracture in a child: a case report.

Traumatic anterior dislocation of the hip joint in children is rare, and only one case with ipsilateral femoral fracture has been reported in Japan. We report a case of such dislocation and a review of the literature. The patient was a 31-month-old girl who was injured in a car accident while asleep on a tilted front passenger seat. Radiographic examination showed dislocation of the right obturator foramen and transverse fracture of the ipsilateral femoral shaft. The dislocation of the right hip was easily reduced without anaesthesia during radiography. We applied Bryant traction after reduction for 4 weeks, followed by cast application for 3 weeks. Walking with support and full weightbearing were permitted 14 weeks and 16 weeks after the injury, respectively. Radiography at 4.5 years after the injury showed a mildly enlarged right femoral head and femur overgrowth of approximately 8 mm. Magnetic resonance imaging showed no evidence of suspected avascular necrosis of the femoral head. The patient has no subjective or objective symptoms, and is able to engage in all usual activities. The detailed mechanism of the injury is unknown. We assume that the lower leg was dislocated through abduction during flexion, or abducent, external flexion, considering that the child was sleeping at the time of the accident. Since she was hurled to the back seat, it was assumed that strong external force was vertically added to the femur, which caused the abducent force.

Accidents, Traffic↗

Seizures, lateral decubitus, aspiration, and shoulder dislocation: Time to change the guidelines?

The recommendation to position a patient having a seizure on a lateral decubitus is aimed at minimizing the risk of aspiration. The authors reviewed the database of the Epilepsy Foundation Clinic of South Florida for patients with epilepsy treated for pneumonia between May 1999 and May 2000 and patients admitted to two university telemetry units who had dislocation of the shoulder during an epileptic seizure. Over 2 months, 2 of 733 adults with intractable seizures had aspiration pneumonia after a generalized tonic clonic seizure (GTCS). Although no study has specifically addressed the problem of aspiration pneumonia in adults with GTCS, our findings suggest this problem is not common. From the two epilepsy centers, 5 of 806 patients dislocated a shoulder during a seizure. Video recordings showed that these patients were positioned in a lateral decubitus by staff while still having the convulsion. The dislocated shoulder in all cases was on the lower side. The risk of shoulder dislocation in a convulsing patient positioned in a lateral decubitus is less than 1%. Nevertheless, dislocations can result in disabling recurrences and are easily preventable. Because aspiration is more likely in the postictal rather than ictal phase of a GTCS, when oral secretions are not usually increased and there is cessation of respiratory movements, lateral decubitus should only be implemented after cessation of the convulsion, In inpatients (such as those on telemetry), secretions may be better managed by bedside aspiration of the oral cavity.

Epilepsy↗

Acute dislocation of the patella with osteochondral fracture: a review of eighteen cases.

Eighteen patients with acute dislocation of the patella had associated osteochondral fractures. This fracture complicates approximately 5% of all acute dislocations of the patella occurring in children. Three types of fracture patterns were noted. All patients who were treated by immediate arthrotomy and excision or replacement of the osteochondral fragment and repair of the acute dislocation of the patella made an uneventful recovery with no recurrence of the dislocation. In those patients in whom the osteochondral fragment was removed but with no repair the dislocation recurred.

Acute Disease↗

Experimental production of forward dislocation in the human cervical spine.

Entire human cadaveric cervical spines with the basiocciput were subjected to load in a compression apparatus to simulate the clinical situation of forward dislocation. The movements were recorded by lateral cineradiography. Vertical load was measured by a potentiometric transmitter synchronised with each frame of the cineradiograph. The lower part of the spine was flexed and fixed, and the upper extended and free to move forward. Vertical compression then produced bilateral dislocation of the facets without fracture. If lateral tilt or axial rotation occurred as well, a unilateral dislocation was produced. The maximum vertical load was only 145 kilograms, and coincided with the rupture of the posterior ligament and capsule and the stripping of the anterior longitudinal ligament, but this occurred before dislocation. The low vertical load indicates a peculiar vulnerabiity of the cervical spine in this position and correlates well with the minor trauma often seen in association with forward dislocation.

Adult↗

Dislocation following total hip replacement.

An analysis of 142 dislocations from a multicentre study of 6774 total hip replacements is reported. The incidence of dislocation was 2.1 per cent. Patients with neuromuscular disorder, those in a confused mental state, and those undergoing revision operations are at special risk. The commonest surgical error, present in nearly half the patients, was placing the acetabular cup too vertically or too anteverted. A less common fault was placing the femoral component too anteverted. Neither the original pathology nor the approach to the hip appeared to affect the likelihood of dislocation. The dislocations were divided into early and late, single and recurrent, and the success rate of treatment is described in these groups. One hundred and eleven patients (78.2 per cent) eventually obtained stability. Of those with a single dislocation, 62 per cent remained stable after a single manipulation. Thirty-four per cent of the patients required an open operation to achieve stability and it is suggested that, in many cases, open reduction alone is not enough; the mechanical fault needs to be corrected.

Acetabulum↗

Simultaneous dislocation of the elbow and the proximal radio-ulnar joint.

Simultaneous dislocation of the elbow and the proximal radio-ulnar joint is rare. Two children with this uncommon injury are reported. One child had a transverse divergent dislocation that was treated successfully by closed reduction. The other had a convergent dislocation (or translocation of the radius and ulna) which needed open reduction. Convergent dislocation is even rarer than transverse divergent dislocation, and this is believed to be the first time it has been reported.

Casts, Surgical↗

A repair operation for recurrent dislocation of peroneal tendons.

A lesion similar to that described by Bankart in recurrent dislocation of the shoulder was seen in seven patients with recurrent dislocation of the peroneal tendons. Detachment of the periosteum had resulted in the formation of a false pouch on the surface of the lower end of the fibula; into this pouch the peroneal tendons could easily dislocate. Reattachment of the periosteum to drill holes in the fibula prevented dislocation, and this anatomical method of repair is described. This lesion is one of the causes of recurrent dislocation of the peroneal tendons.

Adolescent↗

Treatment of chronic post-traumatic dislocation of the radial head in children.

Seven children with chronic post-traumatic dislocation of the radial head were treated by open reduction and ligament reconstruction by a triceps tendon slip. In the four patients with anterior dislocation, good results were achieved; in the two with anterolateral dislocations bowing of the ulna persisted and subluxation recurred. One patient with an anterior dislocation developed a radio-ulnar synostosis. For anterolateral dislocations, we advise the combining of open reduction and ligament reconstruction with osteotomy of the ulna.

Bone Wires↗

The prognosis and treatment of dislocated total hip arthroplasties with a 22 mm head.

We studied the risk of recurrent dislocation in 121 primary and 39 revision Charnley or Charnley hybrid total hip arthroplasties which had been treated for a primary dislocation between 1979 and 1995. Only 35% of these hips had no further dislocation or a revision for instability within one year. The rates of survival gradually declined with time or if a second, third or fourth dislocation occurred. The risk of recurrence was greater in men, but was not related to age, diagnosis, time of the first dislocation or whether the index operation had been a primary or a revision procedure. Operative treatment included 15 reoperations leaving intact components, 50 revisions, and permanent removal of the femoral stem in seven patients. The operation was successful in four patients with reoperations and in 36 who had an exchange procedure within two years. Treatment was successful in 35 of 49 hips in which it was possible to correct a technical error compared with 5 out of 16 hips in which malposition of the components was not seen (p = 0.007).

Aged↗

Anterior dislocation of the shoulder in elderly patients.

Of 545 consecutive patients with anterior shoulder dislocations, 108 (20%) were aged 60 years or more at the time of injury. We reviewed and radiographed 95 of these elderly patients after a mean follow-up of 7.1 years. Axillary nerve injuries were seen in 9.3% of the 108 patients, but all recovered completely in 3 to 12 months. There were single or multiple recurrences of dislocation in 21 patients (22.1%), but within this group age had no influence on the tendency to redislocate. Tears of the rotator-cuff were diagnosed by imaging studies or clinically in 58 patients (61%), including all who had redislocations. Sixteen patients required surgery. Eight with a single dislocation and a cuff tear had only repair of the torn cuff. Of the eight patients with multiple dislocations requiring operation, five also had a torn cuff and needed either a stabilising procedure and a cuff repair or repair of the cuff only. All patients who were operated on had a satisfactory result, with the exception of those with multiple redislocations and a cuff tear who had repair of the cuff only. Anterior shoulder dislocation in elderly subjects is more common than is generally believed; 20% suffer redislocation and 60% have a cuff tear. Operation may be needed to repair a torn cuff or to stabilise the shoulder. Patients with multiple redislocations will probably require both procedures.

Aged↗

Perfusion of the femoral head during surgical dislocation of the hip. Monitoring by laser Doppler flowmetry.

We used laser Doppler flowmetry (LDF) with a high energy (20 mW) laser to measure perfusion of the femoral head intraoperatively in 32 hips. The surgical procedure was joint debridement requiring dislocation or subluxation of the hip. The laser probe was placed within the anterosuperior quadrant of the femoral head. Blood flow was monitored in specific positions of the hip before and after dislocation or subluxation. With the femoral head reduced, external rotation, both in extension and flexion, caused a reduction of blood flow. During subluxation or dislocation, it was impaired when the posterosuperior femoral neck was allowed to rest on the posterior acetabular rim. A pulsatile signal returned when the hip was reduced, or was taken out of extreme positions when dislocated. After the final reduction, the signal amplitudes were first slightly lower (12%) compared with the initial value but tended to be restored to the initial levels within 30 minutes. Most of the changes in the signal can be explained by compromise of the extraosseous branches of the medial femoral circumflex artery and are reversible. Our study shows that LDF provides proof for the clinical observation that perfusion of the femoral head is maintained after dislocation if specific surgical precautions are followed.

Adult↗

Congenital dislocation of the hip.

Early diagnosis and treatment are the keys to a successful result in infants with congenital dislocation of the hip. In the neonatal period, a majority of infants with hips that would later be found to be dislocated can be detected and effectively treated. With the use of ultrasonography to supplement clinical suspicion, the number of children with congenital dislocation of the hip diagnosed in the newborn period should be expected to increase. Repeated examination, especially during the first 6 months of life, can be expected to detect those additional children with congenital dislocation of the hip who were not detected in the nursery. The Pavlik harness has been shown to obtain a successful result in most children younger than 6 months of age while holding the incidence of avascular necrosis to nearly zero. Even though these results are encouraging, the problem must be discovered early for the child with congenital dislocation of the hip to be treated optimally. Thus, it is of the utmost importance that the physician have an awareness of this problem. The primary physician must also continue to conscientiously examine the hips of patients on a regular basis even after the initial examination and, when necessary, use the added modalities available to him or her to accurately diagnose questionable hip conditions of patients.

Female↗

A novel cadaveric model for anterior-inferior shoulder dislocation using forcible apprehension positioning.

A novel cadaveric model for anterior-inferior shoulder dislocation using forcible apprehension positioning is presented. This model simulates an in vivo mechanism and yields capsulolabral lesions. The scapulae of 14 cadaveric entire upper limbs (82 +/- 9 years, mean +/- standard deviation) were each rigidly fixed to a custom shoulder-testing device. A pneumatic system was used with pulleys and cables to simulate the rotator cuff and the deltoid muscles (anterior and middle portions). The glenohumeral joint was then positioned in the apprehension position of abduction, external rotation, and horizontal abduction. A 6-degree-of-freedom load cell (Assurance Technologies, Garner, North Carolina) measured the joint reaction force that was then resolved into three orthogonal components of compression force, anteriorly directed force, and superiorly directed force. With the use of a thrust bearing, the humerus was moved along a rail with a servomotor-controlled system at 50 mm/s that resulted in horizontal abduction. Force that developed passively in the pectoralis major muscle was recorded with an independent uniaxial load cell. Each of the glenohumeral joints dislocated anterior-inferior, six with avulsion of the capsulolabrum from the anterior-inferior glenoid bone and eight with capsulolabral stretching. Pectoralis major muscle force as well as the joint reaction force increased with horizontal abduction until dislocation. At dislocation, the magnitude of the pectoralis major muscle force, 609.6 N +/- 65.2 N was similar to the compression force, 569.6 N +/- 37.8 N. A cadaveric model yielded an anterior dislocation with a mechanism of forcible apprehension positioning when the appropriate shoulder muscles were simulated and a passive pectoralis major muscle was included. Capsulolabral lesions resulted, similar to those observed in vivo.

Aged↗

Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component. A retrospective analysis of fifty-six cases.

Fifty-six constrained acetabular components were placed, between April 1988 and February 1993, in fifty-five patients who had had recurrent dislocations (average, six dislocations; range, two to twenty dislocations) of the femoral component after a previous total hip arthroplasty. All patients had additional factors contributing to the instability of the implant, including absence or disruption of the abductor mechanism, poor health, mental retardation, confusion, and Alzheimer disease. One patient was lost to follow-up. The remaining patients were followed clinically for a minimum of three years (average, sixty-four months; range, thirty-seven to ninety-seven months) or until the time of death. During the follow-up interval, only two (4 per cent) of the fifty-five patients had a subsequent dislocation. The use of this type of component should be considered for patients who have recurrent dislocation if other treatment modalities are unlikely to be effective.

Acetabulum↗

Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement.

BACKGROUND: The purpose of this study was to assess the results of the use of a jumbo femoral head to restore stability in hips that had sustained recurrent dislocations after total hip replacement. METHODS: Twelve hips in twelve patients who had had multiple hip operations and recurrent instability of the hip underwent a total hip replacement with use of a femoral head with an average diameter of 44 mm (range, 40 to 50 mm). The average age of the patients was fifty-nine years (range, twenty-nine to eighty-four years). The twelve patients had had an average of four previous operations (range, one to eight operations) and seven dislocations (range, two to twenty dislocations). A bipolar head was used in ten hips that had a femoral stem with a fixed (non-modular) head, and a modular head (unipolar) was used in two hips. (One hip was first treated with a bipolar head and then with a unipolar head.) RESULTS: One patient died of unrelated causes fourteen months postoperatively. The hip had remained stable until the time of death. After an average duration of follow-up of 6.5 years (range, 3.2 to 11.8 years), ten of the remaining eleven hips had had no additional episodes of instability. One hip dislocated within one week after the revision, necessitating revision surgery to reposition the acetabular component. This hip was found to be stable at the time of follow-up 7.6 years after the revision. There were four other reoperations: one was done because of a fracture of the polyethylene; one, because of entrapment of cement within the articulation; one, because of pain related to loosening of the femoral stem; and one, because of late hematogenous infection. The preoperative and postoperative University of California at Los Angeles hip scores for the series were, respectively, 7 and 9 points for pain, 5 and 7 points for walking, 4 and 6 points for function, and 3 and 5 points for activity. CONCLUSIONS: A jumbo-diameter femoral head provided stability and improved function without compromising range of motion in patients with recurrent dislocations following total hip arthroplasty.

Adult↗

Comparison of intra-articular lidocaine and intravenous sedation for reduction of shoulder dislocations: a randomized, prospective study.

BACKGROUND: Acute anterior glenohumeral dislocations have been commonly treated with closed reduction and the use of intravenous sedation. Recently, the use of intra-articular lidocaine has been advocated as an alternative to sedation, since intravenous access and patient monitoring are not required. The purpose of this study was to evaluate the value of local anesthesia compared with that of the commonly used intravenous sedation during the performance of a standardized reduction technique. METHODS: In a prospective, randomized study, skeletally mature patients with an isolated glenohumeral joint dislocation and no associated fracture were randomized to receive either intravenous sedation or intra-articular lidocaine to facilitate reduction of the dislocation. Reduction was performed with the modified Stimson method. The two groups were compared with regard to the rate of successful reduction, pain as rated on a visual analog scale, time required for the reduction, time from the reduction until discharge from the emergency department, and cost. RESULTS: Thirty patients were enrolled in the study. Five (two in the lidocaine group and three in the sedation group) required scapular manipulation in addition to the Stimson technique to reduce the dislocation. The lidocaine group spent significantly less time in the emergency department (average time, seventy-five minutes compared with 185 minutes in the sedation group, p < 0.01). There was no significant difference between the two groups with regard to pain (p = 0.37), success of the Stimson technique (p = 1.00), or time required to reduce the shoulder (p = 0.42). The cost of the intravenous sedation was $97.64 per patient compared with $0.52 for use of the intra-articular lidocaine. CONCLUSIONS: Use of intra-articular lidocaine to facilitate reduction with the Stimson technique is a safe and effective method for treating acute shoulder dislocations in an emergency room setting. Intra-articular lidocaine requires less money, time, and nursing resources than does intravenous sedation to facilitate reduction with the Stimson technique.

Adolescent↗

Reduction of a dislocation of the hip due to developmental dysplasia. Implications for the need for future surgery.

BACKGROUND: Recent reports on the treatment of a dislocation of the hip due to developmental dysplasia have documented conflicting data on the importance of the ossific nucleus in the development of postreduction ischemic necrosis. Delaying reduction until the ossific nucleus is present bypasses the time-period of maximal osseous remodeling of the hip, thereby possibly increasing the need for future operations. We hypothesized that hips with an ossific nucleus are more likely to have subsequent reconstructive procedures. METHODS: A retrospective review of the medical records at two tertiary-care children's hospitals was completed to identify all patients who had had reduction of a dislocation of the hip due to developmental dysplasia, performed between 1979 and 1993, when they were less than two years old. Patients were excluded if the medical records or radiographs were inadequate, the duration of follow-up was less than three years after the final reduction, a previous reduction had been performed at an outside facility, or the patient had a neuromuscular disease or a teratologic dislocation. We identified 124 patients (153 hips) who satisfied the criteria for inclusion. The average age at the time of the reduction was eleven months, and the average duration of follow-up was 7.2 years. RESULTS: Overall, fourteen of the sixty-three hips without an ossific nucleus had a reconstructive procedure: thirteen had a varus rotational osteotomy of the proximal part of the femur and one had a combined pelvic and varus rotational femoral osteotomy. Forty of the ninety hips with an ossific nucleus had a reconstructive procedure: twenty-seven had a varus rotational osteotomy, eight had a pelvic osteotomy, and five had a combined pelvic and varus rotational osteotomy (p < 0.05). In addition, secondary reconstructive procedures were performed in 17% (ten) of the fifty-nine patients who were less than six months old and in 35% (thirty-three) of the ninety-four patients who were at least six months old, which was a greater than twofold increase. The effect of age was further emphasized at the other age cutoff points. CONCLUSION: Delaying the reduction of a dislocated hip until the appearance of the ossific nucleus more than doubles the need for future surgery to make the hip as anatomically normal as possible. Despite finding a slight increase in the rate of ischemic necrosis after reduction of the hips without an ossific nucleus, we advocate early reduction of a dislocation of a hip due to developmental dysplasia to optimize the development of the hip with the minimum number of operations

Adolescent↗

Dislocation of rotating hinge total knee prostheses. A biomechanical analysis.

BACKGROUND: Symptomatic instability and implant dislocation are occasionally encountered in patients with a rotating hinge total knee prosthesis. A biomechanical study of rotating hinge total knee implants was performed to determine the association between the design (length and taper) of the central rotational stem and the stability of the implant. METHODS: The stem lengths and tapers of knee implants made by seven manufacturers were measured. The tilting laxity of each design was tested by measuring the degree of tilting of the central rotational stem within the tibial housing that occurred with increasing amounts of distraction. The maximum amount of distraction that was possible before the stem dislocated was determined for each design. RESULTS: Implant designs with a short and/or markedly tapered central rotational stem had the greatest tilting, laxity, and instability of that stem. The Howmedica, Techmedica, Intermedics/Sulzer Medica, and Wright Medical Technology/ Dow Corning Wright designs required > or = 39 mm of distraction before they dislocated. The Biomet knee implant required 33 or 44 mm of distraction to dislocate, depending on the thickness of the polyethylene tray that was utilized. The S-ROM knee required only 26 mm of distraction before dislocation occurred. CONCLUSIONS: The measurements confirmed that the shorter the stem and the greater its taper, the greater the instability and laxity at any given amount of joint distraction.