Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

Capillary zone electrophoresis of amino acids on a hybrid poly(dimethylsiloxane)-glass chip.

Poly(dimethylsiloxane) (PDMS)-PDMS and hybrid PDMS-glass devices have been characterized and compared in terms of current-voltage linearity, contact angle, electroosmotic velocity, electroosmotic mobility, and electrokinetic potential in dependence on the surface treatment. The hybrid PDMS-glass microfluidic devices have further been tested as on-chip capillary electrophoresis systems for the separation of fluorescently labeled amino acids. It has been demonstrated that different methods of surface pretreatment of the PDMS-glass devices result in significantly different separation performance, with plate numbers varying from 650 to 57 000 in dependence on the surface state and the nature of the amino acids. Electrophoretic separations of amino acids have been achieved within tens of seconds with detection limits of less than 2 microM (approximately 2 x 10(-16) to 2.5 x 10(-16) mol quantities at injection volumes of 110-120 pL). The detected amounts of fluorescein isothiocyante (FITC)-amino acids are at least ten times lower, since the amino acid:FITC ratio is 10:1 mol. The results demonstrate the perspective of such hybrid PDMS-glass microfluidic systems and the methods to modify their surfaces for on-chip separation methods for biomolecules.

Amino Acids↗

Determination of biochemical species on electrophoresis chips with an external contactless conductivity detector.

Contactless conductivity measurements were found to be suitable for the direct detection, i.e., without needing any labels, of a range of biochemically relevant species, namely amino acids, peptides, proteins, immunoglobulin, and DNA. It was also possible to monitor the products of the enzymatic digestion of HSA with pepsin. Detection was carried out on bare electrophoresis chips made from poly(methyl methacrylate) by probing the conductivity in the channel with a pair of external electrodes, which are fixed on the chip holder. Separation efficiencies up to 15,000 plates could be obtained and LODs are in the low muM-range, except for immunoglobulin G (IgG) which could be determined down to 0.4 nM. Linear dynamic ranges of two to three orders of magnitude were obtained for the peptides as examples.

Amino Acids↗

Rapid on-chip postcolumn labeling and high-resolution separations of DNA.

When performing genetic analysis on microfluidic systems, labeling the sample DNA for detection is a critical preparation step. Labeling procedures often involve fluorescently tagged primers and PCRs, which lengthen experimental run times and introduce higher levels of complexity, increasing the overall cost per analysis. Alternatively, on-chip labeling techniques based on intercalating dyes permit rapid labeling of DNA fragments. However, as noted in the literature, the stochastic nature of dye-DNA complex formation hinders the native electrophoretic migration of DNA fragments, degrading the separation resolution. In this study, we present a novel method of controllably labeling DNA fragments at the end of the electrophoretic separation channel in a glass microfluidic chip. Permitting the DNA to separate and labeling just before detection, achieves the rapid labeling associated with intercalators while maintaining the high resolution of native DNA separations. Our analyses are completed in minutes, rather than the hours typical of sample prelabeling. We demonstrate an electrophoretic microchip-based intercalator labeling technique that achieves higher resolution performance than reported in the literature to date.

DNA↗

Parallel analysis of biomolecules on a microfabricated capillary array chip.

This paper focused on a self-developed microfluidic array system with microfabricated capillary array electrophoresis (mu-CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda-lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high-voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.

Amino Acids↗

On-chip chiral separation based on bovine serum albumin-conjugated carbon nanotubes as stationary phase in a microchannel.

A novel method of chiral separation based on protein-stationary phase immobilized in a poly(methyl methacrylate) microfluidic chip was developed. BSA conjugated with the shortened carboxylic single-walled carbon nanotubes (SWNTs) was employed as the chiral selector. Successful separation of tryptophan enantiomers was achieved in less than 70 s with a resolution factor of 1.35 utilizing a separation length of 32 mm. This is the first example of chiral separation based on SWNTs-BSA conjugates as stationary phase immobilized in microchip channel. The stability of the stationary phase in the channel was examined by microchip electrophoresis with laser-induced fluorescence detection. Factors that influenced the chiral separation resolution were examined. Under the optimized conditions, the proposed modified chip revealed adequate repeatability concerning run-to-run. These results show that the use of SWNTs-BSA conjugates within microfluidic channels hold great promise for a variety of analytical schemes.

Carbon↗

An integrated microfluidic chip for DNA/RNA amplification, electrophoresis separation and on-line optical detection.

This study presents an integrated microfluidic chip capable of performing DNA/RNA (deoxyribonucleic acid/ribonucleic acid) amplification, electrokinetic sample injection and separation, and on-line optical detection of nucleic acid products in an automatic mode. In the proposed device, DNA/RNA samples are first replicated using a micromachine-based PCR module or reverse transcription PCR (RT-PCR) module and then transported by a pneumatic micropump to a sample reservoir. The samples are subsequently driven electrokinetically into a microchannel, where they are separated electrophoretically and then detected optically by a buried optical fiber. The various modules of the integrated microfluidic chip are fabricated from cheap bio-compatible materials, such as PDMS, polymethylmethacrylate, and soda-lime glass. The functionality of the proposed device is demonstrated through its successful application to the DNA-based bacterial detection of Streptococcus pneumoniae and the RNA-based detection of Dengue-2 virus. It is shown that the low thermal inertia of the PCR/RT-PCR modules reduces the sample and reagent consumption and shortens the reaction time. With less human intervention, the subsequent DNA separation and detection could be performed in an automatic mode. The integrated microfluidic device proposed in this study represents a crucial contribution to the fields of molecular biology, genetic analysis, infectious disease detection, and other biomedical applications.

DNA↗

Chip fractures of the mandibular condyle.

Four patients suffered from trauma of the temporomandibular (TM) joints. They were examined by routine x-ray procedures. The x-ray films failed to demonstrate a chip fracture of the head of the mandibular condyle. A coronal computed tomographic (CT) view established the fracture shortly after the trauma in three patients. These patients improved clinically after physiotherapy. The fourth patient was retrospectively diagnosed as having a chip fracture of the mandibular head. She underwent CT scan 10 months posttrauma , and ankylosis of the TM joint was established. The mechanism and the clinical symptoms of this injury, which have not been previously described, are reported in this article.

Adolescent↗

Proliferation assay on a silicon chip applicable for tumors extirpated from mammalians.

We describe a novel anticancer drug sensitivity assay on a silicon chip applicable for tumors extirpated from in vivo mammalians. Human promyelocytic leukemia (HL-60) cells were subcutaneously (s.c.) inoculated in SCID mice, then removed 31 days after the inoculation. The cells were embedded in a small volume (18 nL) of a collagen-gel matrix on a pyramid-shaped silicon microstructure for further cultivation. The respiration activity of the cells on the chip was measured by scanning electrochemical microscopy (SECM). The proliferation behavior was continuously monitored for 6 days. It seemed that the proliferation rate of the cells removed from the mice was lower than that cultured in a flask and conformed to that in mice. The effects of cisplatin (CDDP) and etoposide (VP-16) on the HL-60 cultured in vivo were in good agreement with those obtained by a conventional colorimetric assay. Our results suggest that the SECM-based assay is appropriate for biopsy specimens in a relatively short-time evaluation.

Animals↗

Solving the Poisson-Boltzmann equation with the specialized computer chip MD-GRAPE-2.

The accurate description of solvation effects is highly desirable in numerous computational chemistry applications. One widely used methodology treats the solvent as a uniform continuum ("implicit solvation"), and describes its net interaction with the solute by solving the Poisson-Boltzmann (PB) equation using the Boundary Element Method (BEM). These calculations are very time consuming using conventional computers. A new, efficient way of solving the PB equation on the special-purpose hardware chip MDGRAPE-2 is presented. The MDGRAPE-2 chip was originally developed to speed up the calculation of pairwise van der Waals and electrostatic interactions. By recasting the BEM equations and applying an iterative solution procedure, a hardware-accelerated PB solver on MDGRAPE-2 could be implemented. The performance and reliability of the method is demonstrated on three examples ranging from small peptides to large proteins, whereby the obtained acceleration factors range from 15-fold to up to 40-fold with no loss of accuracy compared to the conventional approach.

Algorithms↗

Multitrack electrospray chips.

Multitrack electrospray chips (MTEC) were fabricated by UV-photoablation of polyethylene terephthalate (PET) substrates. They are composed of an array of up to six microchannels that are successively used as electrospray ionization (ESI) emitters for mass spectrometry (MS). There is no requirement for alignment of the different spraying microchannels with the mass spectrometer orifice. The MTEC is thus fixed in front of the mass spectrometer and the successive MS analyses are performed without moving the chip. The sequential electrospraying by successive application of an identical high voltage in each off-axis microchannel was evaluated for the fast screening of peptides and proteins. The counting of cysteines in peptides through chemical modification and the relative quantification of a peptide in two samples are presented herein as two original strategies based on this new analytical tool.

Journal Article↗

Multi-dimensional HPLC/MS of the nucleolar proteome using HPLC-chip/MS.

The proteome of the human nucleolus was investigated in a single analysis using off-line strong cation exchange chromatography and microfraction collection combined with HPLC-chip/MS. The analysis was conducted either as a 1-D workflow with HPLC-chip alone or as a 2-D workflow. Two hundred and six unique proteins were identified in the International Protein Index human database corresponding to 2024 unique tryptic peptides identified in the 2-D analysis. In contrast, only 34 proteins and 151 corresponding tryptic peptides were found by applying a 1-D separation strategy. This clearly indicated that the complexity of the samples required the combination of more than one orthogonal separation technique. Stringent database search criteria, including reversal of sequences and therefore better exclusion of false-positive identifications, were applied for reliable protein identification.

Cell Nucleolus↗

Light directed massively parallel on-chip synthesis of peptide arrays with t-Boc chemistry.

Peptide and peptidomimetic molecule arrays are emerging powerful tools for parallel screening of binding in proteomics and pharmaceutical discovery research. Up to now the common method of preparing peptide arrays was based on spotting on glass using a library of presynthesized peptides. However, due to the large number of monomers (amino acids) it is not possible to have combinatorial libraries which include all combinations of natural and synthetic amino acids. We describe a very flexible on-chip oligopeptide synthesis method which uses the well developed t-Boc based solid state synthesis chemistry. A very high degree of flexibility is achieved by using light photo generated acids and maskless projection lithography for spatially directed deprotection. Use of microfluidic chips enables moderately high densities, short reaction times and off-the-shelf chemicals. Examples are given from synthesis of metal ion binding peptides and epitope binding assays.

Combinatorial Chemistry Techniques↗

Current status of protein chip development in terms of fabrication and application.

Sequencing of the human genome revealed that more than 30 000 genes encode proteins comprising the human proteome. "Proteomics" can be defined as a field of research studying proteins in terms of their function, expression, structure, modification and their interaction in physiological and in pathological states. The concentration, modification and interaction of proteins in cells, plasma, and in tissues are crucial in determining the phenotype of living organisms. Although fluctuation of protein concentration is essential to maintain homeostasis, protein expression levels are also pathognomonic features. Estimating protein concentration by analyzing the quantity of mRNA in cells through conventional technologies, such as DNA chips, does not provide precise values since the half-life and translation efficacy of mRNA is variable. In addition, polypeptides undergo post-translational modification. For these reasons, novel techniques are needed to analyze multiple proteins simultaneously using protein microarrays. In the near future, protein chips may allow construction of complete relational databases for metabolic and signal transduction pathways. This article reviews the current status of technologies for fabricating protein microarrays and their applications.

Biotin↗

Double chip protein arrays using recombinant single-chain Fv antibody fragments.

Protein arrays permit the parallel analysis of many different markers in a small sample volume. However, the problem of cross-reactivity limits the degree of multiplexing in parallel sandwich immunoassays (using monoclonal antibodies (mAbs)), meaning antibodies must be prescreened in order to reduce false positives. In contrast, we use a second chip surface for the local application of detection antibodies, thereby efficiently eliminating antibody cross-reactions. Here, we illustrate the potential advantages of using single-chain Fv fragments rather than mAbs as capture and detection molecules with this double chip technology.

Biotinylation↗

A thin chip microsprayer system coupled to Fourier transform ion cyclotron resonance mass spectrometry for glycopeptide screening.

A thin polymer microchip was coupled with a Fourier transform ion cyclotron resonance (FTICR) 9.4 T mass spectrometer and the method was optimized in negative ion mode for glycopeptide screening. The interface between the polymer microchip and FTICR mass spectrometer consists of an in-laboratory conceived and designed mounting system that exhibits robust and controllable alignment of the chip toward the inlet of the mass spectrometer. The particular attribute of the polymer chip coupled to the FTICR mass spectrometer, to achieve an increase in ionization efficiency and sensitivity under the premise of high mass accuracy of detection, is highlighted by the large number of major and minor glycopeptide structures detected and identified in highly heterogeneous mixtures obtained from urine matrices. Glycoforms expressing various saccharide chain lengths ranging from tri- to dodecasaccharide, bearing up to three sialic acid moieties, could be detected and assigned based on the accuracy of the mass measurement (average mass deviation below 6 ppm) of their molecular ions. -Thin chipESI-FTICRMS is a potent novel system for glycomic screening of complex mixtures, as demonstrated for identification of singly sialylated O-glycosylated amino acids and peptides from urine matrices, and could be considered for general applicability in the glycoanalytical field.

Amino Acid Sequence↗

Uniformity of ionization response of structurally diverse analytes using a chip-based nanoelectrospray ionization source.

The major drawback of liquid chromatography/mass spectrometry (LC/MS) for the analysis of mixtures is the non-quantitative nature of these studies. The ionization efficiency of the various components in the mixture (e.g., a compound and its metabolites) can vary greatly and, therefore, relative intensities of signals cannot be related to relative abundance. A chip-based nanoelectrospray ionization source was used to compare the ionization efficiencies of compounds with different physical-chemical characteristics. The data indicate that the ionization efficiencies vary much less with the chip-based device than by LC/MS. This was ascribed to the generation of a much higher electric field around the nozzles, which supplies a large excess of protons to the small droplets and reduces/eliminates the differences in the ionization efficiency for the analytes.

Animals↗

Usefulness of an integrated microfluidic device (HPLC-Chip-MS) to enhance confidence in protein identification by proteomics.

Nanoflow liquid chromatography/mass spectrometry (nanoLC/MS) has become a current tool in proteomics applications increasingly used in the search for new biomarkers. A new integrated microfluidic device (HPLC-Chip), coupled to ion trap mass spectrometry (ITMS), appears as an innovative and robust tool for improving the identifications commonly performed by nanoLC/MS/MS. We tested this device for the identification of proteins obtained from two-dimensional gel electrophoresis or chromatography. The chip allows the measurement of reproducible retention times that, in association with m/z ratios, was found useful for identifying peptide sequences without ambiguity. A sensitivity increase of a factor of at least 5-fold is obtained compared to the results obtained previously in our laboratory by conventional nanoLC/MS/MS on the same ion trap. We conclude that this recently available microfluidic device can be a valuable tool during biomarker discovery programs, particularly identifying low-abundance proteins.

Chromatography, High Pressure Liquid↗

Polypyrrole DNA chip on a silicon device: example of hepatitis C virus genotyping.

We describe in this article an oligonucleotide array constructed on a silicon device bearing a matrix of addressable 50-microns microelectrodes. Each electrode was covered by a conducting polymer (polypyrrole) grafted by an oligonucleotide (ODN). The DNA chip was prepared by successive electrochemically addressed copolymerizations of 5' pyrrole-labeled ODN and pyrrole. Following hybridization of the biotinylated amplified sample on the chip bearing a series of probes, detection was carried out by fluorescence microscopy through an R-phycoerythrin label. This technology was successfully applied to the genotyping of hepatitis C virus in blood samples. Results show good sensitivity and a high degree of dimensional resolution.

Biotechnology↗