Can prolonged expiration manoeuvres improve the prediction of arterial PCO2 from end-tidal PCO2?

We have studied, in 16 patients undergoing thoracoabdominal oesophagectomy, if two prolonged expiration manoeuvres improve prediction of arterial PCO2 (PaCO2) from end-tidal PCO2 (PE' CO2). PE' CO2, PCO2 at the end of a simple prolonged expiration (PE1 CO2), and PCO2 at the end of a prolonged expiration preceded by sustained hyperinflation of the lungs (PE2 CO2), were measured during laparotomy, in the lateral thoracotomy position during two-lung ventilation, and after transition to one-lung ventilation. (PaCO2-PE' CO2) was 1.3 (SD 0.4) kPa during laparotomy and this remained stable throughout the study. Both manoeuvres decreased the mean arterial to peak expired PCO2 difference, particularly during one-lung ventilation. However, PE1 CO2 and PE2 CO2 did not agree more closely with PaCO2 than PE' CO2 at any stage of the study. We conclude that these manoeuvres did not improve estimation of PaCO2 from PE' CO2.

Aged↗

Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients.

We have compared four tests for assessing airway sealing pressure with the laryngeal mask airway (LMA) to test the hypothesis that airway sealing pressure and inter-observer reliability differ between tests. We studied 80 paralysed, anaesthetized adult patients. Four different airway sealing pressure tests were performed in random order on each patient by two observers blinded to each other's measurements: test 1 involved detection of an audible noise; test 2 was detection of end-tidal carbon dioxide in the oral cavity; test 3 was observation of the aneroid manometer dial as the pressure increased to note the airway pressure at which the dial reached stability; and test 4 was detection of an audible noise by neck auscultation. Mean airway sealing pressure ranged from 19.5 to 21.3 cm H2O and intra-class correlation coefficient was 0.95-0.99. Inter-observer reliability of all tests was classed as excellent. The manometric stability test had a higher mean airway sealing pressure (P < 0.0001) and better inter-observer reliability (P < 0.0001) compared with the three other tests. We conclude that for clinical purposes all four tests are excellent, but that the manometric stability test may be more appropriate for researchers comparing airway sealing pressures.

Adolescent↗

In vitro and in vivo assessment of the Ventrak 1550/Capnogard 1265 for single breath carbon dioxide analysis in neonates.

The Ventrak 1550/Capnogard 1265 (V&C) enables deadspace (VD) measurements to be made in neonates. The aim of our studies was to validate the V&C device for VD measurement in vitro (lung model) and in vivo (adult rabbits). Methods of measurement of VD using the V&C (automatic computation, interactive carbon dioxide-volume plot analysis, Bohr equation) were tested by comparing known added deadspace volumes (VDadd) with calculated VDadd. After producing a change in alveolar (VDalv) and physiological (VDphys) deadspace by in vivo broncho-alveolar lavage, VDalv and VDphys computed automatically were compared with values calculated by the Bohr-Enghoff equations. VDadd was slightly underestimated (absolute error in mean: automatically -0.61 ml; interactively -0.55 ml; Bohr -0.54 ml). The higher the VDadd, the lower the absolute errors and coefficients of variation (cv). The highest cv occurred for automatic analysis (approximately 11%) compared with < 6% for interactive analysis or the Bohr equation. Average differences between results calculated automatically and by the Bohr-Enghoff equation were -0.79 ml for VDalv (95% confidence interval -2.02 to 0.44 ml) and -0.23 ml for VDphys (-0.6 to 0.14 ml). We conclude that the V&C can be used in newborn infants undergoing mechanical ventilation, if changes in VD are < 5 ml, interactive analysis or the Bohr equation should be used.

Capnography↗

Intubating laryngeal mask for airway management in lateral decubitus state: comparative study of right and left lateral positions.

BACKGROUND: The intubating laryngeal mask has been used for the emergency management of the airway in patients placed in the lateral decubitus position. We have conducted this prospective study to compare the feasibility of placement of an intubating laryngeal mask and blind tracheal intubation guided by the intubating laryngeal mask in patients placed in the right and the left lateral positions. METHODS: A total of 82 adults of both sexes with normal airways, scheduled for cholecystectomy, were allocated randomly to be placed in either the right (n=41) or left (n=41) lateral position for the insertion of an intubating laryngeal mask and blind tracheal intubation guided by the intubating laryngeal mask under balanced general anaesthesia. A sequence of standard manoeuvres was performed after each failed attempt at intubating laryngeal mask placement and intubation. RESULTS: The intubating laryngeal mask was placed in all patients at the first attempt. Ventilation of the lungs through the intubating laryngeal mask was possible in 40 patients (97.5%) from each group after the first attempt at insertion (P=1). Following adjustments, adequate ventilation could be achieved in all patients. The first attempt success rates of blind tracheal intubation were 85.3% (35/41) and 87.8% (36/41) in the right and left lateral groups, respectively (P=1). The remaining patients from both groups (except for one patient in the left lateral group who had a failed intubation) were intubated at the second attempt. CONCLUSION: Insertion of the intubating laryngeal mask and blind tracheal intubation through it in the lateral position is feasible in patients with normal airways. These procedures have a high and comparable success rate when patients are placed in the right and left lateral positions.

Adult↗

Breath interval as a measure of dynamic opioid effect.

We measured breath interval to characterize the time course of opioid effect in anaesthetized patients breathing spontaneously during knee replacement surgery with concurrent regional nerve blockade. Breath interval was recorded before and after a single dose of fentanyl 0.75 microgram kg-1 i.v. Breath interval was measured between the start of successive inspirations, identified by a decrease in carbon dioxide concentration, sampled at the laryngeal mask connection. Nineteen patients were admitted to the study, of whom nine were withdrawn (there was a recording failure for one patient, five patients had inadequate block and three were excessively depressed by the fentanyl). Using MKMODEL software, the mean (SD) dynamic elimination half-life and dynamic mean brain residence time of fentanyl were 15.3 (7.8) and 24.1 (8.1) min, respectively. The times to detection of change from baseline, and peak effect of fentanyl on breath interval were 0.9 (0.6) and 5.2 (1.4) min, respectively. Breath interval increased from 2.9 (1.0) s to a maximum of 9.0 (5.7) s. There were no differences between the time course of changes in breath interval and end-tidal carbon dioxide concentrations. End-tidal carbon dioxide concentrations increased from a baseline of 6.6 (0.9)% to a peak of 8.2 (0.8)%. Breath interval was a useful and reproducible method of monitoring the duration of opioid effect in anaesthetized patients breathing spontaneously when surgical stimulation was not affecting the CNS. The data provide information on the duration of action of fentanyl and could guide dosage.

Adult↗

Noninvasive monitoring of carbon dioxide during respiratory failure in toddlers and infants: end-tidal versus transcutaneous carbon dioxide.

We prospectively compared the accuracy of two noninvasive monitors of arterial CO2 (end-tidal and transcutaneous) in mechanically ventilated infants and toddlers with respiratory failure. The study included infants and toddlers less than 48 mo of age who required tracheal intubation and mechanical ventilation for respiratory failure. In each patient, both ETCO2 and transcutaneous CO2 (TC-CO2) were simultaneously monitored and compared with PaCO2 when an arterial blood gas analysis was performed. The cohort for the study included 25 toddlers and infants ranging in age from 1 to 40 mo and in weight from 3.3 to 19.1 kg. A total of 100 sample sets (PaCO2, ETCO2, TC-CO2) was compared. The ETCO2 to PaCO2 difference was 6.8 +/- 5.1 mm Hg, while the TC-CO2 to PaCO2 difference was 2.3 +/- 1.3 mm Hg (P < 0.0001). The absolute difference of the TC-CO2 and PaCO2 was 4 mm Hg or less in 96 of the 100 values, while the ETCO2 to PaCO2 difference was 4 mm Hg or less in 38 of the 100 values (P < 0.0001). Bland-Altman analysis revealed a bias of -0.68 with a precision of +/-2.35 when comparing the TC-CO2 and the PaCO2 and a bias of -6.68 with a precision of +/-5.01 when comparing ETCO2 with PaCO2. In neonates and infants with respiratory failure, TC-CO2 monitoring provided a more accurate estimation of PaCO2 than ETCO2 monitoring.

Blood Gas Monitoring, Transcutaneous↗

Hypercapnia related to a faulty adult co-axial breathing circuit.

IMPLICATIONS: This report describes the appearance of CO2 on the capnograph during inspiration, which was linked to disconnection of the inner tube of a coaxial circuit extension piece. The increased use of coaxial breathing systems for adults makes inner tubes disconnections an important consideration when the CO2 appears during inspiration.

Anesthesia, Closed-Circuit↗

The influence of nicardipine-, nitroglycerin-, and prostaglandin E(1)-induced hypotension on cerebral pressure autoregulation in adult patients during propofol-fentanyl anesthesia.

UNLABELLED: We investigated the influence of drug-induced hypotension at a mean arterial pressure (MAP) of 60-70 mm Hg on cerebral pressure autoregulation in 45 adult patients during propofol-fentanyl anesthesia. Time-averaged mean blood flow velocity in the right middle cerebral artery (Vmca) was continuously measured at a PaCO(2) of 39-40 mm Hg by using transcranial Doppler ultrasonography. Hypotension was induced and maintained with a continuous infusion of nicardipine, nitroglycerin, or prostaglandin E(1). Cerebral autoregulation was tested by a slow continuous infusion of phenylephrine to induce an increase in MAP of 20-30 mm Hg. From the simultaneously recorded data of Vmca and MAP, cerebral vascular resistance (CVR) was calculated as MAP/Vmca. Furthermore, the index of autoregulation (IOR) was calculated as DeltaCVR/DeltaMAP, where DeltaCVR = change in CVR and DeltaMAP = change in MAP. The test was performed twice for each condition on each patient: baseline and hypotension. The IOR during baseline was similar among the groups. During nitroglycerin- and prostaglandin E(1)-induced hypotension, IOR was not different from baseline. In contrast, during nicardipine-induced hypotension, IOR significantly decreased compared with baseline (0.37 +/- 0.08 versus 0.83 +/- 0.07, P < 0.01). In conclusion, nicardipine, but not nitroglycerin or prostaglandin E(1), significantly attenuates cerebral pressure autoregulation during propofol-fentanyl anesthesia. IMPLICATIONS: Vasodilators may influence cerebral autoregulation by changing cerebral vascular tone. Nicardipine, but not nitroglycerin or prostaglandin E(1), attenuated cerebral pressure autoregulation in normal adult patients during propofol-fentanyl anesthesia.

Alprostadil↗