Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

Detection uncertainty and the facilitation of chromatic detection by luminance contours.

A suprathreshold luminance flash (1 degree, 200 msec) on a large uniform yellow field facilitates detection of a coincident (1 degree, 200 msec) red or green equiluminant flash and approximately linearizes the psychometric function for detecting the chromatic flash. The facilitation is produced by the suprathreshold contour created by the luminance flash. We tested whether the contour facilitates detection by reducing spatiotemporal uncertainty in detecting the chromatic flash. Uncertainty increase false alarms, and this effect can be factored out by correcting yes-no psychometric functions for guessing. Uncertainty also alters the shape of the receiver operating characteristic. Measurements of yes-no psychometric functions and receiver operating characteristics do not support the uncertainty reduction hypothesis.

Color Perception↗

Uniform-scale chromaticity diagram with angular coordinates in zero-curvature space.

Dichromats have angular color discrimination in the usual chromaticity diagrams. Normal trichromatic vision is obtained by combining tritanopic and deuteranopic vision. In this paper, a new pair of angular variables is introduced from which, by a suitable transformation, a uniform-scale chromaticity diagram in zero-curvature space is obtained.

Color Perception↗

Effect of chromatic dispersion on nonlinear phase noise.

We consider the combined effects of amplified spontaneous emission noise, optical Kerr nonlinearity, and chromatic dispersion on phase noise in an optical communication system. The effect of amplified spontaneous emission noise and Kerr nonlinearity were considered previously by Gordon and Mollenauer [Opt. Lett. 15, 1351 (1990)], and the effect of nonlinearity was found to be severe. We investigate the effect of chromatic dispersion on phase noise and show that it can either enhance or suppress the nonlinear noise amplification. For large absolute values of dispersion the nonlinear effect is suppressed, and the phase noise is reduced to its linear value. For a range of negative values of dispersion, however, nonlinear phase noise is enhanced and exhibits a maximum related to the modulation instability found in amplitude fluctuations. Nonlinear phase noise is quenched by these effects even in dispersion-compensated systems; the degree of suppression is sensitively dependent on the dispersion map. We demonstrate these results analytically with a simple linearized model.

Journal Article↗

Chromatic confocal microscopy with a finite pinhole size.

Chromatic confocal microscopy has the advantage of short measurement times because of its parallel depth scan. As most white-light sources have limited optical output power, light-efficient setups are necessary. Using an extended detection pinhole is one way to improve light efficiency. We have calculated the effect of extended pinholes in chromatic confocal setups. We found that, for certain pinhole sizes, the FWHM of the confocal signal is nearly constant over a large wavelength interval.

Microscopy, Confocal↗

Chromatically dispersed interferometry with wavelet analysis.

A new white-light interferometry point sensor utilizing a chromatically dispersed depth detection field is addressed. Monitoring the interference in the optical frequency domain allows for microscopic height detection without the necessity of a mechanical axial scan. The problem of limited dynamic range in previously reported spectral interferometric schemes is solved by forming a high-contrast interference window due to the chromatically dispersed focusing of the detection field. In a proof-of-principle experiment, the position of a reflecting object could be retrieved with a focus of 0.8 NA over an axial range of 30 microm by analyzing the phase of the emerging interference wavelets.

Journal Article↗

[Chromatic sense: types of defects and clinical evaluation tests].

Evaluation of the chromatic sense has a great value in ophthalmic practice, both for diagnosis of the congenital defects (daltonism), as well as for diagnosis and follow-up of acquired defects. Many clinical tests are available to be used for this purpose. However it is necessary to know the details and sensitivity of each test, since there are many variations in the results, depending on the searched condition, if congenital or acquired pathologies. Our goal is to review the types of defects of the chromatic sense and provide information about the main current available tests and their best purpose. We further emphasize the importance of standard illumination procedure in the application of the tests.

Color Perception↗

Specific extraction of chromium as tetrabutylammonium-chromate and spectrophotometric determination by diphenylcarbazide: speciation of chromium in effluent streams.

A very specific, selective, simple, and inexpensive procedure was developed for the speciation of CrVI and CrIII. This method is based on the quantitative extraction of chromate and CrIII (previously oxidized to CrVI) as a tetrabutylammonium-chromate ion-pair in methyl isobutyl ketone (MIBK), and then back extraction and preconcentration with an acidic diphenylcarbazide (DPC) solution. Back extraction was applied to achieve further preconcentration by a final factor of 20. The CrVI-DPC complex was determined in back-extract by a spectrophotometer at 548 nm. Under these extraction conditions, most of the probable concomitant cations and anions remained in the first inorganic phase. The calibration curve was linear up to 0.14 microg L(-1) of CrVI with a detection limit of 2.22 ng L(-1). The developed procedure was found to be suitable for the determination of the CrVI and CrIII species in various natural water samples with a relative standard deviation of better than 1.6%. The method was successfully applied to the speciation of chromium in spiked natural water samples, and also samples of effluent from a leather treatment plant.

Journal Article↗

Arsenic availability from chromated copper arsenate (CCA)-treated wood.

Lumber used to construct raised garden beds is often treated with chromated copper arsenate (CCA). This project aimed to determine (i) how far As, Cu, and Cr had diffused away from CCA-treated wood surfaces in raised garden beds under realistic conditions, (ii) the uptake of these elements by crops, and (iii) the effect of CCA solution on soil bacteria. This study showed that As, Cu, and Cr diffuse into soil from CCA-treated wood used to construct raised garden beds. To determine crop uptake of these elements, contaminated soil 0 to 2 cm from the treated wood was obtained from two different beds (40-50 mg kg(-1) As); control soil was collected 1.5 m away from the treated wood (<3-10 mg kg(-1) As). Four replicates of carrot (Daucus carota var. sativus Hoffm. cv. Thumbelina), spinach (Spinacia oleracea L. cv. Indian Summer), bush bean (Phaseolus vulgaris L. cv. Provider), and buckwheat (Fagopyrum esculentum Moench cv. Common) were grown in pots containing these soils in a greenhouse. After harvest, plant materials were dried, ground, digested, and analyzed for As by inductively coupled plasma-hydride generation (ICP-HG). Concentrations of As in all crops grown in contaminated soils were higher than those from control soils. The levels of As in the crops remained well below the recommended limit for As set by the United States Public Health Service (2.6 mg kg(-1) fresh wt.). To determine if bacteria in soils 0 to 2 cm from the treated wood had higher resistance to Type C chromated copper arsenate (CCA-C) solution than those from reference soils, dilution plates were set up using quarter-strength tryptic soy agar (TSA) media and 0 to 22.94 g L(-1) (0-1.25% v/v) CCA-C working solution. The microorganisms from soils adjacent to treated wood had greater growth on the CCA-amended media than those from reference soils outside the bed.

Arsenates↗

[Chromatic studies of porcelain veneered crown. Influence of the dentin porcelain on the color of opaque porcelain fused on the metal substructure].

The metals for porcelain fusing used in this study were gold alloys and nickel-chromium alloys. Chromatic characteristics were compared between samples of 0.1, 0.2 and 0.3 mm thickness. The dentin porcelain was fused on the opaque surface. Chromatic analyses were then carried out at each stage of 0.1 mm-incremental reductions of the dentin thickness starting from 0.5 mm. In conclusion, the metallic color was not sufficiently hidden by opaque porcelain 0.1 mm thick for both the gold alloy and nickel-chromium alloy samples. The metallic color was sufficiently hidden by opaque porcelain of 0.2 mm thick for the gold alloy sample but was not sufficiently for the nickel-chromium alloy sample.

Chromium Alloys↗

Chromatic perception in relation to an hypothesized cerebral dominance.

On the basis of the cerebral dominance, we have hypothesized an asymmetry (for saturation or brightness) between the two eyes in perception of chromatic stimuli. 51 subjects were tested on chromatic perception (green, red, yellow, blue). For each subject also an ocular-dominance score was obtained. The results substantially confirmed the hypothesis of cerebral dominance in color perception. Subjects with high ocular-dominance scores (right- or left-dominant subjects) showed for the green stimulus asymmetric behavior, while subjects with low ocular-dominance scores showed a tendency toward symmetry in perception.

Adult↗

Exposure to hexavalent chromium does not increase 8-hydroxydeoxyguanosine levels in Korean chromate pigment workers.

This study was performed to determine whether chromium exposure increased 8-hydroxydeoxyguanosine levels in respiratory epithelial and white blood cells of chromate pigment workers. The subjects of this study were 22 chromium pigment workers and 16 controls in a chromate pigments factory. To estimate the level of exposure, hexavalent chromium concentrations in the factory air were measured. Chrominum concentrations of venous blood and spot urine, and 8-hydroxydeoxyguanosine levels in DNA extracted from sputum and white blood cells were determined. Correlation coefficients were calculated between them and their statistical significance was tested. Hexavalent chromium concentration in the factory air ranged from below limit of detection to 0.5150 mg/m3. Chromium levels in blood and 8-hydroxydeoxyguanosine levels in DNA extracted from venous blood and sputum were not statistically different between the two groups. Urine chromium level was significantly higher among workers. Among the correlation coefficients between blood chromium concentration, urine chromium concentration, blood 8-OH-dG level, and sputum 8-OH-dG level, none was statistically significant for workers, controls, and total subjects. Duration of employment did not show any significant correlation with those four variables, either. These results suggest that neither the hydroxyl radical nor 8-hydroxydeoxyguanosine is formed by the reduction of hexavalent chromium, or that one or both of these is formed and then effectively removed by oxygen free radical scavengers or 8-hydroxydeoxyguanosine repair enzymes. Since increased exposure to hexavalent chromium did not result in increased 8-hydroxydeoxyguanosine levels, it is unlikely that hexavalent chromium induces lung cancer through 8-hydroxydeoxyguanosine formation.

8-Hydroxy-2'-Deoxyguanosine↗

Binocular summation of chromatic changes as measured by visual reaction time.

We determined visual reaction times to monocular and binocular changes in the luminance of isochromatic stimuli and to monocular and binocular changes in the color of isoluminant stimuli. Two isoluminant color changes were tested: chromatic variations along the red-green axis of Boynton's (1986) two-stage color vision model and chromatic variations along the yellow-blue axis of the same model. The results indicate a greater degree of binocular summation for luminance change than for color change. This result was largely independent of the motor component of reaction time.

Adult↗

Effects of monochromatic and chromatic oblique aberrations on visual performance during spectacle lens wear.

An optical system is described which allows overall visual performance to be studied when the wearer of a spectacle lens views objects through the lens periphery. Performance with lenses of any refractive power can be explored without any need for subjects to have the appropriate complementary refractive errors. In comparison with the effects of dioptric defocus, transverse chromatic aberration (TCA) is found to cause a relatively greater degradation in contrast sensitivity at high spatial frequencies when tangentially-oriented gratings are observed. The relative importance of TCA appears to have been underestimated in some previous studies. As vision is found to be affected by both TCA and defocus, a careful compromise between chromatic and monochromatic aberrations is required.

Adult↗

[Study of dental chromatic space].

Dental chromatic space has been the topic for many studies and most of all indicated that dental structures are very versatile from the colour point of view, therefore a proper shade selection is difficult to made. Our study made a comparison between the shades of dental structures of men and women of different ages, the measurements being done in three regions: incisal, middle and cervical. We used a spectrophotometer Spectra-Flash 600 and the PC programme Data-Master version 2.3 for both chromatic determinations and the statistical evaluations. The study proved that there are no major differences between the dental shades of men and women; meanwhile chrome increases with age and from incisal to cervical regions. Also, value increases from incisal to cervical region.

Adolescent↗

Correlation of chromatic, spatial, and temporal sensitivity in optic nerve disease.

Spearman rank-order correlations (R) were made between the color-mixture threshold, spatial contrast sensitivity, and flicker sensitivity measurements of 38 patients with a variety of optic nerve disorders. Patients had to satisfy the following criteria: greater than 0.5 log unit loss of chromatic or achromatic sensitivity (compared to age-matched normals), central fixation, no congenital color defects, and no ocular media abnormalities. The results of the analysis show a significant correlation between selective losses of high spatial frequency sensitivity (relative to low) and selective losses of red/green and blue/yellow sensitivities [R = -0.680 (P less than 0.001) and R = -0.439 (P less than 0.01), respectively]. A mild correlation was found between selective spatial and selective temporal losses [r = -0.399 (P less than 0.05)] (ie, low temporal frequency losses correlate with high spatial frequency losses and vice versa). A stronger correlation was found between selective red/green and selective blue/yellow sensitivity losses [R = 0.657 (P less than 0.001)]. No correlation was found between selective temporal losses and selective chromatic losses. These findings can be explained in terms of differential losses of three types of fibers: (1) fibers that are particularly sensitive to red/green color, high spatial and low temporal frequencies; (2) fibers signalling blue/yellow color; and (3) fibers that are relatively sensitive to high temporal frequencies and low spatial frequencies.

Adolescent↗

Ocular chromatic aberration and age.

The amount of longitudinal chromatic aberration in groups of younger and older subjects is compared in three separate studies, using a laser speckle optometer, Badal optometers with monochromatic illumination, and monochromatic retinoscopy. No evidence is found for any systematic change in chromatic aberration with age.

Adult↗

Effect of illuminance on the directions of chromostereopsis and transverse chromatic aberration observed with natural pupils.

The direction of chromostereopsis observed with a natural pupil and the direction of the monocularly perceived disparity between coloured targets (F and C lines - 486 and 656 nm) have been measured in a sample of 30 subjects at 10 and 1000 lx. At both illumination levels approximately equal numbers of subjects perceived positive and negative chromostereopsis. When the ambient illumination was increased, a reversal in the direction of the chromostereopsis occurred for 16 subjects. For six of them a change from a positive to a negative chromostereopsis was observed, a pattern not reported in previous studies. In most cases at both high and low illuminance, there was an absence of perception of a monocular disparity (transverse chromatic aberration), although chromostereopsis was reported, indicating that binocular information can be obtained from sub-threshold monocular disparities. At low illuminance, the lack of correlation between the direction of chromostereopsis and transverse chromatic aberration (TCA) may indicate that there may be a supplementary binocular factor in chromostereopsis.

Adult↗

The organization of chromatic and spatial interactions in the primate striate cortex.

The cytochrome oxidase-rich patches or blobs of the monkey striate cortex have been shown to contain cells that have unoriented receptive fields, many of which are color selective. We studied the functional organization of color opponency in the blob regions of the parafoveal representation of the visual cortex. We also examined the patterns of connectivity among blob and nonblob cells by multiple electrode penetrations and cross-correlation analysis. Some of the color-selective cells in the blobs exhibited receptive fields that were similar to those found in the parvocellular layers of the lateral geniculate nucleus (LGN): one type exhibited center-surround spatial and chromatic opponency corresponding to the Type I cell found in the LGN; another had center-only chromatic opponency, corresponding to the Type II cell of the LGN. A blob color-selective cell with no LGN counterpart had center color opponency with a nonchromatically opponent surround antagonism. We termed this cell the "modified Type II" cell. Contrary to previous reports, few true double color-opponent cells were found. Some blob cells previously characterized as double opponent probably belong to our modified Type II category and, unlike true double opponent cells, do not respond well to isoluminant color boundaries. Occasional color-selective oriented cells were either intermixed or in close proximity to blob cells. Neighboring electrode penetrations within the same blob yielded cells of the same color opponency, either red versus green or blue versus yellow, suggesting that individual blobs are dedicated to processing one color opponency. Blobs dedicated to red/green color opponency were 3 times more numerous than blue/yellow blobs. Furthermore, the cells in layer 4C lying beneath blobs of a given color opponency had identical color opponency to the overlying cells in blobs. Cross-correlation analysis of pairs of nonblob, oriented cells in the superficial layers showed interactions between cells with matched orientation and eye preference, at varying horizontal separations. Such interactions are consistent with anatomically demonstrated clustered horizontal connections. Positive cross-correlograms were found between blob cells in the same and in adjacent blobs when the cells' receptive field type, color opponency, and ocular dominance matched. Correlograms also indicated monosynaptic connections from Type II to modified Type II cells of the same color opponency, suggesting that Type II cells may contribute to the construction of the modified Type II fields in the cortex.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗