Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44Linked to original sources

High-performance liquid chromatographic method for the determination and pharmacokinetic study of wogonoside in rat serum after oral administration of traditional Chinese medicinal preparation Huang-Lian-Jie-Du decoction.

A high-performance liquid chromatographic method for the determination of wogonoside in plasma of rats administrated orally with the traditional Chinese medicinal preparation Huang-Lian-Jie-Du decoction was developed. Sample preparation was carried out by protein precipitation with a mixture of acetonitrile and methanol (1:1, v/v). The extracted sample was separated on a Hypersil C(18) (150 x 5 mm i.d., 5 microm) analytical column by linear gradient elution using 0.05% (v/v) phosphoric acid (containing 5 mm sodium dihydrogen phosphate) and acetonitrile as mobile phase at a flow rate of 1.5 mL/min. The eluate was detected using a UV detector at 276 nm. The assay was linear over the range 0.109-7.0 microg/mL (R(2) = 0.9999, n = 5). Mean recovery was determined as 98.39%. Intra- and inter-day precisions (RSD) were < or =7.59%. The limit of quantitation was 0.109 microg/mL. After validation, the HPLC method developed was applied to investigate the preliminary pharmacokinetics of wogonoside in rat after oral administration of Huang-Lian-Jie-Du decoction.

Administration, Oral↗

Refined tunable methodology for characterization of contaminant-particle relationships in surface water.

To understand contaminant transport in aquatic systems, it is essential to define the physical characteristics of the primary particulate carriers. The distribution of organic pollutants with particle-size class and particle morphology in a freshwater embayment (Hamilton Harbor, western Lake Ontario) was studied using a sequence of novel sample preparation and characterization techniques. Water samples (24 L) were fractionated according to particle-size distribution using differential cascade sedimentation and centrifugation methods. These size fractions were subsequently subjected to a physicochemical characterization using scanning transmission electron microscopy and energy-dispersive spectroscopy to identify flocs and individual colloidal particles in the size range of 1 nm to 1 mm in diameter. Analytical chemical analyses were performed to identify organic contaminants in extracts prepared from particle-size classes, including polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). The contaminant distribution trends were very similar for all compound classes studied; contaminants were primarily associated with fractions containing particles less than 2 mum in diameter. Morphological characterization of these fractions showed the majority of the particulates to be humic fractals. The results of this study show that contaminants in aquatic systems can be preferentially associated with specific types of particle carriers, the characteristics of which can be clearly defined in terms of size and morphology.

Colloids↗

[The quantitative determination of vitamin D3 and its metabolites in plasma].

A method is described which enables determination of vitamin D3 and its physiologically most important metabolites, i.e. 25-OHD3, 24,25-(OH)2D3, 25,26-(OH)2D3 and 1,25-(OH)2D3 in a plasma sample of about 2 to 4 ml. The whole procedure involves two preparative and one analytical steps: Extraction with methanol/methylene chloride (2:1), chromatographic separation on Lipidex 5000 using a stepwise gradient of n-hexane and chloroform and finally HPLC separation on Zorbax-Sil columns with n-hexane isopropanol mixtures and subsequently reversed phase separation on RP 18-columns and mixtures of methanol and water. Except for 1,25-(OH)2D3 all D compounds were quantified by UV-detection with 1.4 ng of substance being the lowest detectable amount. 1,25-(OH)2D3 was measured by radioimmunoassay. Prior to HPLC analysis the extract was separated into three fractions on Lipidex 5000 which contained 1) vitamin D3, 2) 25-OHD3 and 3) the dihydroxy metabolites. The three fractions were separated by HPLC using different mixtures of isopropanol/n-hexane and methanol/water, respectively. Retention times of the individual D-components longer than 10 min appeared to be essential to separate these compounds from accompanying material. Overall recoveries of the individual metabolites were for vitamin D3 48.9%, for 25-OHD3 54.2%, for 24,25-(OH)2D3 50.9% and for 1,25-(OH)2D3 52.5%. Application of the methods to plasma samples from pigs with pseudovitamin D deficiency rickets, typ I, revealed a reduced concentration of 1,25-(OH)2D3 and 24,25-(OH)2D3 and an elevated level of 25-OHD3 in these animals. The results obtained by this method contributed substantially to a better understanding of the aetiological factors associated with this disease.

Biotransformation↗

Use of multivariate curve resolution for determination of chromium in tanning samples using sequential injection analysis.

We report a method for determining total chromium in tanning samples using sequential injection analysis (SIA) with a diode-array spectrophotometric detector. With a suitable analytical sequence CrO4(2-) is converted to Cr2O7(2-) inside the tubes of the SIA system, after total oxidation of chromium(III). A data matrix is obtained and analysed by several chemometric techniques based on multivariate analysis: principal components analysis, simple-to-use interactive self-modelling mixture analysis, and multivariate curve resolution-alternating least-squares. We studied several samples from different stages of a tanning process. Two of these samples were easily oxidized but the others needed more extreme conditions. The analytical sequence prepared, which was based on obtaining a pH gradient and used H2SO4 as reagent, is valid and independent of the level of oxidation needed for the sample. We established a calibration model and evaluated the figures of merit. In some samples we found interferents. With this method the amounts of chromium in each sample were quantified and the results were statistically similar to those obtained by use of the reference method, atomic absorption spectrometry.

Journal Article↗

Liquid chromatographic method for the determination of uridine in human serum.

To evaluate uridine levels in humans we developed a very sensitive and specific high-performance liquid chromatographic method for the determination of uridine in serum. We use techniques which are available in a standard analytical laboratory. Chromatographic analysis was carried out on a Phenomenex Aqua C18 5 micro 125A column protected by a guard cartridge system. Potassium dihydrogen phosphate buffer-acetonitrile was used as an eluent and oxypurinol as the internal standard. All sample preparation steps were done at 4 degrees C and the autosampler was cooled down to 4 degrees C. The calibration curve was linear throughout the calibration range from 0.25 to 100 micromol/l. This method was primarily established to evaluate uridine serum levels in patients with HIV infection since patients on highly active antiretroviral therapy (HAART) might develop metabolic disturbances that could lead to severe and fatal lactic acidosis due to mitochondrial toxicity. It is suggested that a limited or inadequate uridine supply is at least in part responsible for the onset of such deterioration.

Calibration↗

Applications of solid-phase microextraction in food analysis.

Food analysis is important for the evaluation of the nutritional value and quality of fresh and processed products, and for monitoring food additives and other toxic contaminants. Sample preparation, such as extraction, concentration and isolation of analytes, greatly influences the reliable and accurate analysis of food. Solid-phase microextraction (SPME) is a new sample preparation technique using a fused-silica fiber that is coated on the outside with an appropriate stationary phase. Analyte in the sample is directly extracted to the fiber coating. The SPME technique can be used routinely in combination with gas chromatography (GC), GC-mass spectrometry (GC-MS), high-performance liquid chromatography (HPLC) or LC-MS. Furthermore, another SPME technique known as in-tube SPME has also been developed for combination with LC or LC-MS using an open tubular fused-silica capillary column as an SPME device instead of SPME fiber. These methods using SPME techniques save preparation time, solvent purchase and disposal costs, and can improve the detection limits. This review summarizes the SPME techniques for coupling with various analytical instruments and the applications of these techniques to food analysis.

Food Analysis↗

Determination of chlortetracycline in swine plasma by LC-ESI/MS/MS.

A rapid, selective and sensitive method has been developed for the determination of chlortetracycline in swine plasma by LC-ESI/MS/MS. The method consists of a protein precipitation extraction for sample preparation and liquid chromatography ionspray tandem mass spectrometry for analysis. The plasma samples were extracted with acetonitrile and the supernatants were analyzed using an LC-ESI/MS/MS instrument. Separation was achieved using a C(8) analytical column and an isocratic mobile phase composed of 70:30 acetonitrile:0.5% formic acid in water at a flow rate of 500 microL/min. A linear (weighted 1/concentration) relationship was used to perform the calibration over an analytical range 20--2000 ppb (ng/mL). The intra-batch precision and accuracy at LLOQ, medium and high concentrations were 9.0, 11.3 and 9.9% and 97.7, 100.3 and 98.4%, respectively, and the inter-batch precision and accuracy at LLOQ, medium and high concentrations were 9.1, 8.4 and 7.4% and 95.1, 102.1 and 97.1%, respectively. This LC-ESI/MS/MS method for the determination of chlortetracycline in swine plasma has been proven to be within generally accepted criteria used for bioanalytical assay.

Animals↗

Investigation of matrix effects of urine on a molecularly imprinted solid-phase extraction.

This study investigates matrix effects on a molecularly imprinted solid-phase extraction (MISPE) method developed for the clean-up of diphenyl phosphate (a hydrolysis product of the commonly used flame retardant and plasticizer, triphenyl phosphate) in urine samples. The influence of potentially interfering compounds that naturally occur in urine was examined with respect to extraction recovery, repeatability and selectivity. The components tested were NaCl, urea, creatinine and hippuric acid. The imprinted polymer was prepared using 2-vinylpyridine as the functional monomer, ethylene glycol dimethacrylate as crosslinker and a structural analogue of the analyte as the template molecule. The recovery of diphenyl phosphate from water standards was over 90% using MISPE, compared to less than 25% using a non-imprinted SPE (NISPE) counterpart. The selectivity of MISPE compared to NISPE was achieved in a wash step with a basic modifier in methanol. The recovery and repeatability of the MISPE method were affected most by NaCl in the tested concentrations, while urea, creatinine and hippuric acid had no significant influence. NaCl most likely weakens the binding during the loading of the sample. This effect could be suppressed by diluting the sample with a citrate buffer at pH 4.0.

Creatinine↗

High-performance liquid chromatographic determination of the mucoregulatory drug CO/1408 in rat plasma and urine.

A sensitive and selective high-performance liquid chromatographic (HPLC) method was developed for the determination of the mucoregulatory drug CO/1408 in plasma and urine. Samples containing an internal standard were prepared for analysis using a simple clean-up procedure based on Extrelut solid-phase extraction and chromatographed using a reversed-phase analytical column. Isocratic elution with a mobile phase consisting of 25 mM phosphate buffer (pH 2.5)-acetonitrile-methanol [85:10:5 or 87:9:4 (v/v) for plasma or urine analysis, respectively] was effected at a flow-rate of 0.8 ml/min. The eluate was monitored with an ultraviolet-visible variable-wavelength detector at 200 nm. The limit of quantification for the assay of CO/1408 was 80 ng/ml for plasma and 1 per 0.1 ml for urine samples. In spite of the high solubility of CO/1408 in water, the recovery from plasma and urine was very good and reproducible. The method was found to be applicable to pharmacokinetic studies of the drug in the rat.

Animals↗

Nanoflow liquid chromatography coupled to matrix-assisted laser desorption/ionization mass spectrometry: sample preparation, data analysis, and application to the analysis of complex peptide mixtures.

We report the development of a robust interface for off-line coupling of nano liquid chromatography (LC) to matrix-assisted laser desorption/ionisation-mass spectrometry (MALDI-MS) and its application to the analysis of proteolytic digests of proteins, both isolated and in mixtures. The interface makes use of prestructured MALDI sample supports to concentrate the effluent to a small sample plate area and localize the MALDI sample to a predefined array, thereby enriching the analyte molecules and facilitating automated MALDI-MS analysis. Parameters that influence the preparation of MALDI samples from the LC effluent were evaluated with regard to detection sensitivity, spectra quality, and reproducibility of the method. A procedure for data processing is described. The presented nano LC MALDI-MS system allowed the detection of several peptides from a tryptic digest of bovine serum albumin, at analyzed amounts corresponding to one femtomole of the digested protein. For the identification of native proteins isolated from mouse brain by two-dimensional gel electrophoresis, nano LC MALDI-MS increased the number of detected peptides, thereby allowing identification of proteins that could not be identified by direct MALDI-MS analysis. The ability to identify proteins in complex mixtures was evaluated for the analysis of Escherichia coli 50S ribosomal subunit. Out of the 33 expected proteins, 30 were identified by MALDI tandem time of flight fragment ion fingerprinting.

Animals↗

SIMS microscopy: methodology, problems and perspectives in mapping drugs and nuclear medicine compounds.

Secondary ion mass spectrometry (SIMS) microscopy, a mass spectrometry method designed in the 1960s, offers new analytical capabilities, high sensitivity (ppm to ppb region), high specificity and improved lateral resolution, thus facilitating insight into many physiological and biomedical questions. Apart from the sample preparation and the physical characteristics of the detection, the biological model must also be considered. SIMS analysis of diffusible ions and molecules requires strict cryogenic procedures which always begin by a flash-freeze fixation. Cellular integrity can be checked by mapping the major element distributions since intra and extracellular ions are redistributed only in damaged cells. Cryofixing may be followed either by a freeze-fracture methodology or by cryoembedding and dry-cutting. Chemical sample preparation is only used for ions or molecules bound to fixed cell structures. The use of scanning procedures ameliorates the lateral resolution and chromosome imaging has been reported with probe size of below 50 nm. Absolute quantification can be derived for embedded specimen by using internal references included in tissue equivalent resins. The sensitivity is limited by the ionization yield of the tag element and may be further impaired when working at high mass resolution (> or = 5000) to eliminate interfering cluster ions. SIMS drug mapping is usually performed after in vitro administration of a molecule to cell culture systems. Drug detection is accomplished indirectly by detecting a tag isotope naturally present or introduced by labelling, mainly with halogens, 15N and 14C. Molecular imaging with TOF-SIMS is an appealing alternative especially for heavier compounds. We stress some biological problems through a critical review of published SIMS drug studies. SIMS proved useful in assessing the targeting specificity of nuclear medicine pharmaceutics, even after in vivo administration. The first microscopic evidence of a thionamide induced follicular blockade of the iodine organification process is presented in a human sample.

Animals↗

Determination of carbendazim, thiabendazole, and o-phenylphenol residues in lemons by HPLC following sample clean-up by ion-pairing.

An efficient analytical method is presented involving effective sample clean-up with solid-phase extraction and HPLC-UV analysis for the simultaneous determination of carbendazim, thiabendazole, and o-phenylphenol residues in lemons. Sample preparation involves extraction with acetonitrile acidified with trifluoroacetic acid and an ethyl acetate/petroleum ether mixture. Purification of the crude extract was carried out with liquid-liquid partitioning after addition of an aqueous ammonia solution. Final clean-up was performed on polymeric reversed-phase cartridges pretreated with sodium dodecyl sulfate. Chromatographic analysis was performed on a reversed-phase HPLC column isocratically eluted with an acetonitrile/water/ammonia mixture and UV detection at 254 nm. The chromatographic method is repeatable, reproducible, and sensitive. Fungicide recoveries from lemon samples fortified at levels of 5 and 1 mg kg(-1) were 81-85% for carbendazim, 96-98% for thiabendazole, and 81-106% for o-phenylphenol with coefficients of variation of 2.5-7.4%. Detection limits for carbendazim, thiabendazole, and o-phenylphenol in lemons were 0.21, 0.27, and 0.51 mg kg(-1), respectively.

Journal Article↗

Application of a chemometric method for simultaneous determination of acetaminophen and diclofenac in content-uniformity and drug-dissolution studies.

A new, repeatable, and rapid method has been developed for resolution of binary mixtures of acetaminophen and diclofenac with minimum sample pretreatment and without separation of the analytes. The method, based on the PLS1 processing of absorbance data in the UV region, was successfully used for quantification of the drug content of three tablet preparations. The results obtained were in good agreement with HPLC recovery data. The method also enabled determination of drug-dissolution profiles of these commercial tablets, by simultaneous determination of both analytes during the dissolution test.

Acetaminophen↗

Sensitive and selective determination of picogram amounts of ciprofloxacin and its metabolites in biological samples using high-performance liquid chromatography and photothermal post-column derivatization.

An analytical method for the detection and quantification of ciprofloxacin and its known metabolites M1, M2, M3 and M4 in urine, serum/plasma, bile, faeces and tissue is described. For the liquid matrices the only sample preparation that is required is dilution. The assay consists of reversed-phase high-performance liquid chromatography and fluorescence detection. For the metabolites M2, M3 and M4 an additional post-column derivatization by successive thermolysis and photolysis is needed. A suitable simple post-column reactor has been constructed. Detection limits for all compounds are between 0.2 and 2.2 ng/ml (absolute detection limits 2-22 pg). Compared with fluorescence detection alone, the derivatization increases the selectivity of detection significantly. The linearity, precision and accuracy of the method were determined.

Bile↗

Ultrasensitive assay of azithromycin in medicine and bio-fluids based on its enhanced luminol-H(2)O(2) chemiluminescence reaction using flow injection technique.

A simple flow injection chemiluminescence method with synergistic enhancement has been investigated for the rapid and sensitive determination of azithromycin. The synergistic action was significant in the chemiluminescence system of luminol-hydrogen peroxide with azithromycin as an enhancer. The enhanced chemiluminescence intensity was linear with the concentration of azithromycin over the range from 0.1 pg x mL(-1) to 1.0 ng x mL(-1) (r(2=)0.9988) with a detection limit (3sigma) of 0.04 pg x mL(-1). At a flow rate of 2.0 mL x min(-1), a complete analytical process could be performed within 0.5 min, including sampling and washing, with a relative standard deviation of less than 3.0%. The proposed method was applied successfully in the assay of azithromycin in pharmaceutical preparations, human urine and serum without any pre-treatment procedure.

Anti-Bacterial Agents↗

Dynamic hollow fiber-supported headspace liquid-phase microextraction.

With the increasing concern over deteriorating environmental quality, the analysis of organic pollutants in air, water, and soil has become critically important. The development of simple, efficient, and inexpensive analytical sample pretreatment is crucial for monitoring and evaluating the environment. In this work, a dynamic hollow-fiber supported headspace liquid-phase microextraction (DHF-HS-LPME) approach was developed. In dynamic LPME, the extracting solvent is held within a hollow fiber, affixed to a syringe needle and immersed in the sample solution, and is moved to-and-fro by using a programmable syringe pump. The movement facilitates mass transfer from the sample to the solvent. Here, a similar approach was adopted, except that extraction was from the headspace rather than by direct immersion. Analysis of the extract was carried out by gas chromatography-mass spectrometry. The effect of sampling temperature, water, salt, dwelling time were investigated. Results indicated that this novel headspace microextraction method gave good analyte-enrichment factors, linear range, limits of detection and repeatability, all of which were evaluated by extracting PAHs from soil samples. This technique represents an inexpensive, convenient, fast and simple sample preparation of this class of semi-volatile organic compounds.

Chromatography, Liquid↗

Automated sample preparation for the determination of budesonide in plasma samples by liquid chromatography and tandem mass spectrometry.

An automated bioanalytical method for the determination of the glucocorticosteroid drug budesonide in plasma samples at pM levels was investigated. The method was built using three separate automated analytical steps with manual transfer of samples between them. In the first step, a Tecan RSP150 (Genesis) pipetting robot was used to transfer 1 ml of centrifuged plasma samples and deuterated budesonide internal standard solutions into tubes and to homogenise the resulting admixture. In the second step, a solid-phase extraction was performed using an ASPEC Xli (Gilson) with 100 mg Isolute C18 columns. In order to avoid conventional time-consuming evaporation and reconstitution steps, the solid-phase extraction was coupled on-line to a trace enrichment system for further purification and concentration of the sample extracts. The concentrated samples were eluted in 300 microliters ethanol into injection vials, which were capped and transferred to the autosampler in the detection system. In the third step, the pre-treated samples were chromatographed in a gradient LC system and detected using a tandem MS system (Finnigan TSQ 7000), with an atmospheric pressure chemical ionisation interface. The described Analytical System consisting of one Tecan robot, two ASPEC systems and one LC-MS-MS system may analyse up to about 800 samples a week with less routine work for the analyst. The concentration range studied was 15 to 2500 pM in 1 ml spiked plasma samples and the limit of quantitation for the described method was determined as 15 pM, as defined by accuracy and precision better than 20%.

Administration, Topical↗

Sensitive high-performance liquid chromatographic determination of nifedipine in dog plasma using an automated sample preparation system with laboratory robot.

Nifedipine, a calcium-channel blocking drug was analysed in dog plasma after oral dosing with two different formulations. Sample preparation was automated with a laboratory robot. Quantitative determination of the drug was performed on a reversed-phase HPLC system with electrochemical detection (ED) using an internal standard. Validation of the analytical method showed that the system is well suited for pharmacokinetic studies on dogs. The assay was linear in the range 1-50 ng/ml. Inter-day and intra-day variability were between 6.43-18.15% C.V. and 1.57-5.53% C.V., respectively.

Animals↗