Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “TESTES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Preclinical and clinical performance of the Efoora test, a rapid test for detection of human immunodeficiency virus-specific antibodies.

Barriers to effective diagnostic testing for human immunodeficiency virus type 1 (HIV-1) infection can be reduced with simple, reliable, and rapid detection methods. Our objective was to determine the accuracy, sensitivity, and specificity of a new rapid, lateral-flow immunochromatographic HIV-1 antibody detection device. Preclinical studies were performed using seroconversion, cross-reaction, and interference panels, archived clinical specimens, and fresh whole blood. In a multicenter, prospective clinical trial, a four-sample matrix of capillary (fingerstick) whole-blood specimens and venous whole blood, plasma, and serum was tested for HIV-1 antibodies with the Efoora HIV rapid test (Efoora Inc., Buffalo Grove, IL) and compared with an enzyme immunoassay (EIA) (Abbott Laboratories) licensed by the Food and Drug Administration. Western blot and nucleic acid test supplemental assays were employed to adjudicate discordant samples. Preclinical testing of seroconversion panels showed that antibodies were often detected earlier by the rapid test than by a reference EIA. No significant interference or cross-reactions were observed. Testing of 4,984 archived specimens yielded a sensitivity of 99.2% and a specificity of 99.7%. A prospective multicenter clinical study with 2,954 adult volunteers demonstrated sensitivity and specificity for the Efoora HIV rapid test of 99.8% (95% confidence interval [CI], 99.3 and 99.98%) and 99.0% (95% CI, 98.5 and 99.4%), respectively. Reactive rapid HIV-1 antibody detection was confirmed in 99.6% of those with a known HIV infection (n = 939), 5.2% of those in the high-risk group (n = 1,003), and 0.1% of those in the low-risk group (n = 1,012). For 21 (0.71%) patients, there was discordance between the results of the rapid test and the confirmatory EIA/Western blot tests. We conclude that the Efoora HIV rapid test is a simple, rapid assay for detection of HIV-1 antibodies, with high sensitivity and specificity compared to a standardized HIV-1 EIA.

HIV Antibodies↗

Is serological testing a reliable tool in laboratory diagnosis of syphilis? Meta-analysis of eight external quality control surveys performed by the german infection serology proficiency testing program.

The accuracy of diagnostic tests is critical for successful control of epidemic outbreaks of syphilis. The reliability of syphilis serology in the nonspecialist laboratory has always been questioned, but actual data dealing with this issue are sparse. Here, the results of eight proficiency testing sentinel surveys for diagnostic laboratories in Germany between 2000 and 2003 were analyzed. Screening tests such as Treponema pallidum hemagglutination assay (mean accuracy, 91.4% [qualitative], 75.4% [quantitative]), Treponema pallidum particle agglutination assay (mean accuracy, 98.1% [qualitative], 82.9% [quantitative]), and enzyme-linked immunosorbent assays (ELISAs) (mean qualitative accuracy, 95%) were more reliable than Venereal Disease Research Laboratory (VDRL) testing (mean accuracy, 89.6% [qualitative], 71.1% [quantitative]), the fluorescent treponemal antibody absorption test (FTA-ABS) (mean accuracy, 88% [qualitative], 65.8% [quantitative]), and immunoblot assays (mean qualitative accuracy, 87.3%). Clearly, immunoglobulin M (IgM) tests were more difficult to manage than IgG tests. False-negative results for samples that have been unambiguously determined to be IgM and anti-lipoid antibody positive accounted for 4.7% of results in the IgM ELISA, 6.9% in the VDRL test, 18.5% in the IgM FTA-ABS, and 23.0% in the IgM immunoblot assay. For negative samples, the mean percentage of false-positive results was 4.1% in the VDRL test, 5.4% in the IgM ELISA, 0.7% in the IgM FTA-ABS, and 1.4% in the IgM immunoblot assay. On average, 18.3% of participants misclassified samples from patients with active syphilis as past infection without indicating the need for further treatment. Moreover, 10.2% of laboratories wrongly reported serological evidence for active infection in samples from patients with past syphilis or in sera from seronegative blood donors. Consequently, the continuous participation of laboratories in proficiency testing and further standardization of tests is strongly recommended to achieve better quality of syphilis serology.

Antibodies, Bacterial↗

Polymerase chain reaction assay for the detection of Helicobacter pylori in gastric biopsy specimens: comparison with culture, rapid urease test, and histopathological tests.

Ulcer recurrence is probably related to residual Helicobacter pylori (H pylori). Histological examination and culture are considered to be the most specific tests. CLO test is a rapid but less specific test, which is usually used as an alternative test to culture. The aim of this study was to investigate the efficiency of a simplified polymerase chain reaction (PCR) assay as a procedure for the diagnosis of gastric H pylori infection of patients. Biopsy specimens were obtained from antral mucosa of 58 patients at endoscopy and submitted to four tests for detection of H pylori. The bacteria were found in 53%, 43%, 48%, and 50% of patients according to the results of PCR, CLO test, culture, and histological examination. Twenty three patients had both negative histology and negative culture and PCR was negative in all of these. Thirteen patients were not classified because only histology or culture was positive and 10 of these had a positive PCR test. When the diagnosis of H pylori was established by agreement with both histology and culture or three positive tests out of four, 29 patients were H pylori positive (28 having had three positive tests and one displaying positive histology and culture), and 26 were negative, and three undetermined. PCR proved the most sensitive and specific test. These results suggest the simplified PCR assay may be a valuable test for the detection of H pylori.

Adult↗

A COMPARISON OF THE ROSE-WAALER, LATEX FIXATION, "RA-TEST," AND BENTONITE FLOCCULATION TESTS.

The bentonite flocculation test of Bozicevich, Bunim, Freund, and Ward (1958), the latex fixation test of Singer and Plotz (1956), and the "RA-test" (a latex reagent for use as a slide test) of Hyland Laboratories have been compared with each other and with a modified Rose-Waaler test, the behaviour of which has been previously extensively investigated. In these tests sera from 2,250 patients were tested by two or more methods on 3,000 occasions. The findings of this trial are set out and the merits of the tests and reasons for disagreement among them are discussed. It is concluded that the most satisfactory means of testing rheumatoid sera is by the Rose-Waaler test and the "RA-test," or a satisfactory modification of it, in parallel.

Journal Article↗

Computerised pathology test order entry reduces laboratory turnaround times and influences tests ordered by hospital clinicians: a controlled before and after study.

OBJECTIVE: To assess the impact of a computerised pathology order entry system on laboratory turnaround times and test ordering within a teaching hospital. METHODS: A controlled before and after study compared test assays ordered from 11 wards two months before (n = 97 851) and after (n = 113 762) the implementation of a computerised pathology order entry system (Cerner Millennium Powerchart). Comparisons were made of laboratory turnaround times, frequency of tests ordered and specimens taken, proportions of patients having tests, average number per patient, and percentage of gentamicin and vancomycin specimens labelled as random. RESULTS: Intervention wards experienced an average decrease in turnaround of 15.5 minutes/test assay (range 73.8 to 58.3 minutes; p<0.001). Reductions were significant for prioritised and non-prioritised tests, and for those done within and outside business hours. There was no significant change in the average number of tests (p = 0.228), or specimens per patient (p = 0.324), and no change in turnaround time for the control ward (p = 0.218). Use of structured order screens enhanced data provided to laboratories. Removing three test assays from the liver function order set resulted in significantly fewer of these tests being done. CONCLUSIONS: Computerised order entry systems are an important element in achieving faster test results. These systems can influence test ordering patterns through structured order screens, manipulation of order sets, and analysis of real time data to assess the impact of such changes, not possible with paper based systems. The extent to which improvements translate into improved patient outcomes remains to be determined. A potentially limiting factor is clinicians' capacity to respond to, and make use of, faster test results.

Chi-Square Distribution↗

Evaluation and therapeutic regulation of erectile dysfunction with visual stimulation test. An objective approach by using sildenafil citrate test.

AIM: An objective evaluation of the psychogenic cause of erectile dysfunction by performing the visual stimulation tumescence and rigidity (VSTR) test and sildenafil citrate test, together with the effectiveness of sildenafil citrate medication on impotence caused by different etiologies. MATERIAL AND METHODS: Between 1998 and 2000, a total of 36 men (12 patients with diabetic etiology, 5 patients with vasculogenic risk factor) were enrolled in this study. The mean age of patients was 53 (27-67) years. Following standard questionnaires, including a detailed anamnesis from an andrologic viewpoint, VST was performed in an ambulatory setting and beginning with a test dose of 50 mg. At the end of 2 h, the data was evaluated with computer assistance (Rigiscan device) and if a satisfactory erection had not occurred, an additional second dose of sildenafil citrate (50 mg) was given until there was a satisfactory erection. Results obtained from VST: results were classified as group I (fully rigidity, >10 min erection, >70% of rigidity, possible vaginal penetration), group II (unstable erection, 5 min erection, >70% of rigidity, possible vaginal penetration) and group III (tumescence without rigidity, <5 min erection, <70% of rigidity, impossible vaginal penetration). The results obtained during the first 1 h of the VSTR test were regarded as the patient's own erectile condition and later data was accepted as the real effect of sildenafil citrate. The Fisher exact test was used for statistical evaluation including pre- and post-sildenafil effect on erectile rigidity and duration of erection. RESULTS: The erection status of patients was sufficient in 17 (47.2%) in group I, it was insufficient but sufficient enough with an increased dose of sildenafil citrate in 10 (27.7%) in group II, and insufficient without/with full dose of sildenafil citrate in 9 (25%) in group III. Considering rigidity and total erectile period, there was a statistical significant difference between the first two groups with respect to the early and late sildenafil citrate effects on the VSTR test (p < 0.05). Again, 10 patients with known risk factors (diabetes mellitus 5 and vasculogenic 5) in the second group seemed to give a good response to repeated dosage of sildenafil citrate which has been found to be very interesting. However, the rest of the diabetic patients (n = 7) in the third group showed no erection despite the increasing and repeated doses of sildenafil citrate. CONCLUSION: Sildenafil citrate with the VSTR test has effective and reliable results which was regarded as very important to diagnose and determine objectively the amount of therapeutic doses in impotence. In accordance with the literature data, our results also confirm the reliability and the practical nature of the VSTR test, which is less time-consuming and cheaper than the nocturnal penile tumescence and rigidity (NPTR) test. In the VSTR test, necessary doses of medication needed for satisfactory erection were easily regulated in patients with certain kinds of impotence. Additionally, self-criticism advantage of the patients on erection and an unnecessary need for regular sexual partners may make this test preferable in the near future. However, we believe that a large group of patients with other definite parameters are certainly needed in order to obtain more reliable data.

Adult↗

Comparative study between audiovisualsexual stimulation test and nocturnal penile tumescence test using RigiScan Plus in the evaluation of erectile dysfunction.

INTRODUCTION: Although the nocturnal penile tumescence (NPT) test is considered the gold standard for the differential diagnosis of psychogenic versus organic erectile dysfunction (ED), concerns have recently been raised regarding the financial and time expenditure it demands. We evaluated the diagnostic efficacy of the audiovisual sexual stimulation (AVSS) test as an alternative to the NPT test. PATIENTS AND METHODS: A total of 43 patients with ED were examined. Each patient filled in an International Index of Erectile Function (IIEF) questionnaire. The evaluation of each patient consisted of AVSS and NPT tests which were performed using the RigiScan Plus. The results obtained with the two tests were compared. The patients with normal NPT patterns were presumed to have a psychogenic etiology of their ED and those with abnormal NPT patterns to have an organic etiology. RESULTS: The overall IIEF score was 32.5 +/- (SD) 9.2, and the erectile domain score was 12.2 +/- 4.5. Twenty-three patients had normal responses to the AVSS test, while 20 had abnormal responses. Twenty-two of the former 23 patients and 9 of the latter 20 patients had normal NPT patterns. Therefore, the AVSS test discriminated psychogenic ED with 71% sensitivity and 92% specificity. The overall accuracy of the test in this study was 77%. CONCLUSIONS: The AVSS test is simple, practical, and inexpensive, and its diagnostic accuracy is comparable to that of the NPT test. We conclude that the AVSS test should be the examination of choice for the primary etiological diagnosis in ED.

Adult↗

Development of an in vitro test battery for the estimation of acute human systemic toxicity: An outline of the EDIT project. Evaluation-guided Development of New In Vitro Test Batteries.

The aim of the Evaluation-guided Development of new In Vitro Test Batteries (EDIT) multicentre programme is to establish and validate in vitro tests relevant to toxicokinetics and for organ-specific toxicity, to be incorporated into optimal test batteries for the estimation of human acute systemic toxicity. The scientific basis of EDIT is the good prediction of human acute toxicity obtained with three human cell line tests (R(2) = 0.77), in the Multicentre Evaluation of In Vitro Cytotoxicity (MEIC) programme. However, the results from the MEIC study indicated that at least two other types of in vitro test ought to be added to the existing test battery to improve the prediction of human acute systemic toxicity - to determine key kinetic events (such as biotransformation and passage through biological barriers), and to predict crucial organ-specific mechanisms not covered by the tests in the MEIC battery. The EDIT programme will be a case-by-case project, but the establishment and validation of new tests will be carried through by a common, step-wise procedure. The Scientific Committee of the EDIT programme defines the need for a specific set of toxicity or toxicokinetic data. Laboratories are then invited to perform the defined tests in order to provide the "missing" data for the EDIT reference chemicals. The results obtained will be evaluated against the MEMO (the MEIC Monograph programme) database, i.e. against human acute systemic lethal and toxicity data. The aim of the round-table discussions at the 19th Scandinavian Society for Cell Toxicology (SSCT) workshop, held in Ringsted, Denmark on 6-9 September 2001, was to identify which tests are the most important for inclusion in the MEIC battery, i.e. which types of tests the EDIT programme should focus on. It was proposed that it is important to include in vitro methods for various kinetic events, such as biotransformation, absorption in the gut, passage across the blood-brain barrier, distribution volumes, protein binding, and renal clearance/accumulation. Models for target organ toxicity were also discussed. Because several of the outlier chemicals (paracetamol, digoxin, malathion, nicotine, paraquat, atropine and potassium cyanide) in the MEIC in vivo-in vitro evaluation have a neurotoxic potential, it was proposed that the development within the EDIT target organ programme should initially be focused on the nervous system.

Biotransformation↗

Maximum Shannon information content of diagnostic medical testing. Including application to multiple non-independent tests.

The increase in Shannon information available from a diagnostic test associated with grading of the test results into many outcomes, rather than simply positive or negative, was examined to determine its upper limit as the number of test outcomes is increased indefinitely. Numerical methods were employed to find the optimal locations of outcome boundaries when a single normally distributed test variable is classified into 2, 3, 4, 5, 6, 8, 14, or 20 outcome categories. In each case Shannon information was computed for values of prior probability between 0.01 and 0.99 and for distances between the means in diseased and nondiseased populations ranging from 0.5 to 5.0 standard deviations. There is an important improvement in Shannon information as the number of outcomes defined is increased, but the increment in information diminishes rapidly with each additional category. A 20%-30% increment in information may be achieved with three outcomes instead of two. A further important increase in information occurs with four to seven outcomes, but beyond this the increment in inforation is negligible. The findings were similar over a wide range of prior probabilities and distances between the means. The analysis was extended to the case of multiple nonindependent tests by demonstrating their application to a Fisher discriminant function incorporating such tests. It was concluded that for normally distributed test variables: grading of test results significantly improves the information content of both single and multiple tests; the value of information content for 8-20 outcomes represents very nearly the maximum information content of a test; there is little value in using more than five to seven test outcomes; multiple grading should not be neglected for discriminant functions.

Bayes Theorem↗

Predictors of home radon testing and implications for testing promotion programs.

Four data sets (total N = 3,329) are examined to identify the predictors of home radon testing. The data, interpreted in terms of a stage model of radon testing behavior, reveal that the variables predicting transitions between stages change as people move from one stage to the next. Thinking about radon testing (vs. never having even considered testing) is best predicted by general radon knowledge and by knowing other people who are concerned or have tested. Once contemplating testing, the decision to test is most closely related to the perceived likelihood of a home radon problem. Finally, there are few differences between people who say they have decided to test and those who have already tested. Instead situational factors--including difficulties in locating and choosing among test kits--appear to constitute the final barrier to testing. The ways in which these findings might assist the design of radon outreach programs are discussed, and specific outreach recommendations are advanced.

Cost-Benefit Analysis↗

A note on the asymptotic distribution of likelihood ratio tests to test variance components.

When using maximum likelihood methods to estimate genetic and environmental components of (co)variance, it is common to test hypotheses using likelihood ratio tests, since such tests have desirable asymptotic properties. In particular, the standard likelihood ratio test statistic is assumed asymptotically to follow a chi2 distribution with degrees of freedom equal to the number of parameters tested. Using the relationship between least squares and maximum likelihood estimators for balanced designs, it is shown why the asymptotic distribution of the likelihood ratio test for variance components does not follow a chi2 distribution with degrees of freedom equal to the number of parameters tested when the null hypothesis is true. Instead, the distribution of the likelihood ratio test is a mixture of chi2 distributions with different degrees of freedom. Implications for testing variance components in twin designs and for quantitative trait loci mapping are discussed. The appropriate distribution of the likelihood ratio test statistic should be used in hypothesis testing and model selection.

Chromosome Mapping↗

Improved laboratory test selection and enhanced perception of test results as tools for cost-effective medicine.

Inconsistencies in the way physicians perceive and handle identical laboratory results have untoward effects on morbidity, mortality and cost of medical care. In this context, the selection of suitable tests to answer definite clinical questions, and the manner in which laboratory results are presented have great impact on the action taken by the clinician. This review addresses preferred methods to improve laboratory test selection, and examines methods that more effectively convey laboratory results to clinicians. It is anticipated that refined selection of tests, and presentation of the test results in a configuration that is easily perceived by the clinician, will facilitate interpretation of laboratory reports. Furthermore, any measures that promote the application of laboratory information in medical practice improve economics at the laboratory-clinical interface. The presently described methods to optimize test selection and interpretation are: likelihood ratios to provide estimates of the ability of a test to identify a clinical condition; consensus- and discriminant function-analysis to estimate the performance of tests in diagnosing a particular disease or condition; receiver operating characteristic (ROC) curves to assess discrimination capabilities. The methods which improve test result perception are expression of results as multiples of the upper normal limit, utilizing signal strength to provide prognostic probabilities, and presentation of results in graphic forms that display mutually interrelated functions, with a specific cluster of results being highly suggestive of a given condition. In addition, we discuss application of expert systems to provide rules based on knowledge and experience to analyze results of tests and suggest diagnosis and action, including additional tests when required. It is anticipated that judicious utilization of laboratory services by application of the reviewed methodologies will help to achieve medically justified responses at a lower cost and help to achieve a proper balance between cost of tests and their clinical usefulness.

Clinical Laboratory Techniques↗

Discrepant results in the diagnosis of GH deficiency with the insulin-tolerance test and the GHRH plus arginine test in patients with traumatic brain injury.

OBJECTIVE: Patients with traumatic brain injury (TBI) are at moderate risk of GH deficiency (GHD), requiring a diagnostic test with high specificity. The GHRH + arginine (GHRH + ARG) test has been recommended as a reliable alternative to the insulin-tolerance test (ITT) as a standard test with a cutoff level of 9 ng/ml. However, it has recently been questioned for its low specificity in obese subjects, and now BMI-dependent cut-off levels are available. In this study, we compared the ITT and GHRH + ARG test in patients with TBI. DESIGN: A cross-sectional study METHODS: We performed an ITT and a GHRH + ARG test in 21 patients with TBI (6 women, 15 men; mean age 40.2 +/- 12.1 years; BMI 30.7 +/- 6.2). The number of patients classified discordantly as GH deficient by the ITT and the GHRH + ARG test with both classical and BMI-dependent cut-off levels was assessed. RESULTS: Using the GHRH + ARG test with the classical cut-off ( 3 ng/ml), and one patient as GH sufficient who had a blunted GH response to ITT (discordance rate 61.9%). All patients discordantly classified as GH deficient by the GHRH + ARG test had a BMI of >or= 28. With the BMI-dependent cut-offs (4.2, 8.0, and 11.5 ng/ml in obese, overweight, and lean subjects respectively), only 3 of the 21 patients were discordantly classified (discordance rate 14.3%). CONCLUSIONS: Our results discourage the use of a cut-off level of 9 ng/ml for the GHRH + ARG test in obese subjects. The diagnostic reliability of this test is improved with the BMI-dependent cut-offs.

Adult↗

Increasing voluntary HIV testing by offering oral tests in incarcerated populations.

OBJECTIVES: This study reports responses of incarcerated persons to voluntary blood and oral HIV testing. METHODS: Males and females in local detention and juvenile justice facilities in Maryland (n = 1314) chose oral or blood testing and reported reactions to the oral HIV test. The relationship of demographics and HIV risk factors to test choice was examined. RESULTS: Reactions to oral testing were very favorable; some participants reported that they would not otherwise have been tested. Participants who chose oral testing were more likely to be male and African American, but they did not differ from those who chose blood testing in most risk factors or in seroprevalence. CONCLUSIONS: Oral HIV testing in correctional settings may promote voluntary testing among persons who otherwise would refuse or avoid testing, especially among groups (males and African Americans) disproportionately affected by HIV.

AIDS Serodiagnosis↗

Evaluation of a bladder tumor antigen test as a screening test for transitional cell carcinoma of the lower urinary tract in dogs.

OBJECTIVE: To evaluate the veterinary version of the bladder tumor antigen (V-BTA) test as a screening test for transitional cell carcinoma (TCC) of the lower urinary tract of dogs. ANIMALS: 229 client-owned dogs. PROCEDURE: Urine samples from dogs were shipped overnight to a single laboratory to facilitate testing within 48 hours of collection by use of the V-BTA rapid latex agglutination urine dipstick test. Groups of dogs included the following: 1) dogs with TCC of the lower urinary tract, 2) healthy control dogs, 3) unhealthy control dogs with non-TCC urinary tract disease, and 4) unhealthy control dogs without urinary tract disease. Test sensitivity and specificity were calculated by use of standard methods. Logistic models were developed to assess the effect of disease status, test conditions, urine composition, and signalment on the performance of the V-BTA test. RESULTS: A total of 229 urine samples were analyzed, including 48 from dogs with suspected (n = 3) or confirmed (45) TCC. Test sensitivities were 88, 87, and 85% for all dogs with (suspected and confirmed) TCC, dogs with confirmed TCC at any site, and dogs with confirmed TCC of the urinary bladder, respectively. Test specificities were 84, 41, and 86% for healthy control dogs, unhealthy control dogs with non-TCC urinary tract disease, and unhealthy control dogs without urinary tract disease, respectively. The test performed slightly better on centrifuged urine samples than on uncentrifuged urine samples. CONCLUSIONS AND CLINICAL RELEVANCE: Our results indicate that the V-BTA test is useful in screening for urinary tract TCC in dogs.

Animals↗

Guidelines for clinical use of the antinuclear antibody test and tests for specific autoantibodies to nuclear antigens. American College of Pathologists.

The following guideline presents a series of recommendations based on published medical literature for use of the antinuclear antibody (ANA) test and tests for specific autoantibodies to nuclear antigens in the diagnostic evaluation, prognostic assessment, and monitoring of patients with systemic rheumatic diseases. The guideline emphasizes the need for clinical evaluation to improve the usefulness of test results in patient management. Consideration is given to appropriate use of the generic ANA test in the initial evaluation of patients with signs and symptoms of a systemic rheumatic disease, the evaluation of patients suspected of having lupus erythematosus, use in clinical situations in which the ANA test is required to establish a disease diagnosis, and identification of clinical situations in which the ANA test has little value. Sections are also devoted to recommendations aimed at improving the analytic methods used to detect and measure ANA and specific autoantibodies to nuclear antigens and to the appropriate use of tests for specific autoantibodies in several disease situations that commonly occur in patients with suspected or documented systemic rheumatic diseases. Emphasis is placed on the use of these tests only in situations in which the test results can be expected to provide information necessary for clinical decision making. Those tests of limited medical usefulness and situations in which test results are likely to be misleading are also identified.

Antibodies, Antinuclear↗

Identification of nonanalytic issues in HIV-1 antibody testing using blind proficiency testing.

Blind proficiency testing was used to examine nonanalytic performance indicators for human immunodeficiency virus type 1 (HIV-1) antibody testing. Physician offices, clinics, and hospitals located throughout Southern California submitted simulated patient specimens to laboratories as routine test requests. A total of 32 laboratories were involved during five blind proficiency testing surveys. Turnaround time for a reactive specimen ranged from three to 17 days. Laboratory charges for evaluating a reactive specimen varied depending on the volume of testing, prevalence of reactive specimens, and whether screening and confirmatory tests were billed separately or as a package price. Charges for an enzyme immunoassay screening test plus supplemental tests ranged from $11.75 to $114.50, with a median of $31.00 for 24 laboratories that participated in one of the five surveys. Evaluation of laboratory report content revealed that 37% of the 16 screening reports and 71% of the 14 supplemental reports contained information that was unrelated to the patient results. Evaluation of the testing system documents the need to monitor multiple outcomes of the total laboratory testing process, not just the analytic testing phase.

AIDS Serodiagnosis↗

Reactivity of blood pressure to mental arithmetic stress test, stress-test recovery time, and ambulatory blood pressure in hypertensive and normotensive subjects.

BACKGROUND: Laboratory mental stress testing and 24 h ambulatory blood pressure monitoring may analyse reactivity of blood pressure during provoked stress and stressful situations in daily-life, respectively. OBJECTIVE: To evaluate whether the responses to a mental stress test and during the stress-test recovery time were associated with ambulatory blood pressure parameters. METHODS: Fifty-two untreated male subjects (22 normotensives and 30 hypertensives) were subjected both to mental arithmetic stress testing and ambulatory blood pressure monitoring. RESULTS: We found a positive correlation between baseline and peak-test blood pressures during the stress test and 24 h blood pressures. Maximal values of systolic and diastolic blood pressures measured during the 24 h were also correlated to the maximal systolic and diastolic blood pressures reached during the stress test ( P < 0.001). We observed no relationship between reactivity during the stress test and 24 h parameters. On the contrary, changes in diastolic blood pressure during the time of recovery from the stress test (expressed as percentage-change scores) were correlated to the 24 h diastolic blood pressure parameters, the diastolic load being the most closely associated variable. CONCLUSION: The absence of relationships between variations in blood pressure during the provoked stress and ambulatory monitoring parameters indicates that reactivity of blood pressure to an acute stress does not predict the 24 h profile. However, the correlation between the maximal blood pressure measured by ambulatory monitoring and that observed during stress testing indicates that the maximal 24 h values may show the extreme blood pressure response (like the one provoked acutely by a laboratory stress test) of an individual subject. The correlation between the percentage-change score during the recovery time of diastolic blood pressure and the 24 h diastolic load could account forr a lower than normal capacity for recovery of subjects with persistently high blood pressures.

Journal Article↗