Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RIGIDITY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Membrane Response to Diclofop Acid Is pH Dependent and Is Regulated by the Protonated Form of the Herbicide in Roots of Pea and Resistant and Susceptible Rigid Ryegrass.

Electrophysiological studies in roots of pea (Pisum sativum L.) and rigid ryegrass (Lolium rigidum Gaud.) seedlings were conducted to elucidate the mechanism involved in the membrane response to the herbicide diclofop. In pea, a dicotyledonous plant insensitive to diclofop, membrane depolarization at varying pH values and herbicide concentrations increased at higher concentrations of the protonated form of diclofop acid (pKa 3.57). In unbuffered nutrient solution (pH 5.7), diclofop acid (50 [mu]M) depolarized the membrane potential (Em) in roots of both resistant and susceptible biotypes of rigid ryegrass, whereas recovery of Em occurred only in the resistant biotype following removal of the herbicide. This differential response was correlated with an increase (450%) in the rate of acidification of the external solution by the susceptible biotype, and the Em differences between biotypes were eliminated in solutions buffered at pH 5.0 or 6.0. In addition, p-chloromercuribenzene-sulfonic acid did not prevent the depolarization of Em by 50 [mu]M diclofop acid. It is concluded that the differential membrane response to diclofop acid in herbicide-resistant and -susceptible biotypes of rigid ryegrass is due to pH differences at the cell wall/plasmalemma interface. Although the membrane response is probably not involved in the primary inhibitory effect of diclofop on plant growth, it could reduce the concentration of the permeant protonated form of the herbicide and possibly could contribute to increased tolerance to diclofop and other weak acid herbicides.

Journal Article↗

Freezing Characteristics of Rigid Plant Tissues (Development of Cell Tension during Extracellular Freezing).

The freezing characteristics and development of cell tension during extracellular freezing were examined in supercooling stem tissues of riverbank grapes (Vitis riparia) and cold-hardened leaves of live oak (Quercus virginiana) and mountain cranberry (Vaccinium vitis-idaea). Dormant stem xylem and pith tissues of river-bank grapes were resistant to freeze-induced dehydration above the homogeneous nucleation temperature, and they developed cell tension reaching a maximum of 27 MPa. Similarly, extracellular freezing induced cell tension in the leaves of live oak and mountain cranberry. Maximum cell tension in the leaves of live oak was 16.8 MPa and 8.3 MPa in the leaves of mountain cranberry. Following peak tensions in the leaves, a decline in the pressure was observed with progressive freezing. The results suggest that resistance to cell deformation during extracellular freezing due to cell-wall rigidity can lead to reduced cell dehydration and increased cell tension. A relationship to predict freezing behavior in plant tissues based on cell rigidity is presented. Based on cell-water relations and ice nucleation rates, cell-wall rigidity has been shown to effect the freezing characteristics of plant tissues, including freeze-induced dehydration, supercooling, and homogeneous nucleation temperatures.

Journal Article↗

Segmented anisotropic refinement of bovine ribonuclease A by the application of the rigid-body TLS model.

The anisotropic displacements of selected rigid groups in bovine ribonuclease A have been refined from X-ray diffraction data by the application of the rigid-body TLS model. The rigid groups chosen were the side chains of tyrosine, histidine and phenylalanine and the planar side chains of aspartic acid, glutamic acid, glutamine, asparagine and arginine. The method has also been applied to the co-crystallizing active-site sulfate anion. This has enabled the description of the motion of the above-mentioned side-chain atoms by anisotropic displacement ellipsoids from a 1.45 A refinement. The hydrophobic side groups in the protein core show mainly translational motion, with mean-square librations of 20 deg2 which are similar to those found in some close-packed crystals of small organic molecules. Librational displacements are much more significant in the hydrophilic side groups where their magnitudes can be correlated with solvent accessibility. Large librations of some solvent exposed side chains correspond with the breakdown of a simple TLS model and the existence of multiple orientations of the side groups. The TLS model has also been applied to the whole protein molecule and shows that the average motion is approximately isotropic with little librational character.

Animals↗

The segmented anisotropic refinement of monoclinic papain by the application of the rigid-body TLS model and comparison to bovine ribonuclease A.

The anisotropic displacements of selected rigid groups in monoclinic papain have been refined from X-ray diffraction data by application of the rigid-body TLS model. The rigid groups chosen were the aromatic side chains of tryptophan, tyrosine, histidine and phenylalanine, and the planar carboxylic and guanidinium side chains of aspartic acid, glutamic acid, glutamine, asparagine and arginine. The derived translation and libration tensors have been compared with those previously derived for bovine ribonuclease A and provide evidence for different modes and anisotropies of displacement over the two proteins.

Amino Acids↗

Mutual information-based rigid and nonrigid registration of ultrasound volumes.

We investigated the registration of ultrasound volumes based on the mutual information measure, a technique originally applied to multimodality registration of brain images. A prerequisite for successful registration is a smooth, quasi-convex mutual information surface with an unambiguous maximum. We discuss the necessary preprocessing to create such a surface for ultrasound volumes. Abdominal and thoracic organs imaged with ultrasound typically move relative to the exterior of the body and are deformable. Consequently, four specific instances of image registration involving progressively generalized transformations were studied: rigid-body, rigid-body + uniform scaling, rigid-body + nonuniform scaling, and affine. Registration was applied to clinically acquired volumetric images. The accuracy was comparable with the voxel dimension for all transformation modes, although it degraded as the transformation grew more complex. Likewise, the capture range became narrower with the complexity of transformation. As the use of real-time three-dimensional ultrasound becomes more prevalent, the method we present should work well for a variety of applications examining serial anatomic and physiologic changes. Developers of these clinical applications would match the deformation model of their problem to one of the four transformation models presented here.

Algorithms↗

A fast impulsive contact suite for rigid body simulation.

A suite of algorithms is presented for contact resolution in rigid body simulation under the Coulomb friction model: Given a set of rigid bodies with many contacts among them, resolve dynamic contacts (collisions) and static (persistent) contacts. The suite consists of four algorithms: 1) partial sequential collision resolution, 2) final resolution of collisions through the solution of a single convex QP (positive semidefinite quadratic program), 3) resolution of static contacts through the solution of a single convex QP, 4) freezing of "stationary" bodies. This suite can generate realistic-looking results for simple examples yet, for the first time, can also tractably resolve contacts for a simulation as large as 1,000 cubes in an "hourglass." Freezing speeds up this simulation by more than 25 times. Thanks to excellent commercial QP technology, the contact resolution suite is simple to implement and can be "plugged into" any simulation algorithm to provide fast and realistic-looking animations of rigid bodies.

Algorithms↗

Rigidity and retention of carbon fibre versus stainless steel root canal posts.

Two of the main requirements of a root canal post are that it is rigid so as to resist flexing under functional load, and that it is well retained in the root. This study compared these properties in two different 1-mm diameter root canal posts--smooth carbon fibre posts (Endopost) and serrated stainless steel posts (Parapost). Ten posts of each type were tested for rigidity in a three-point bend test. Ten posts of each type were cemented with resin cement into the roots of endodontically treated, extracted teeth. The tensile force required to remove the posts was recorded. The Paraposts proved to be significantly more rigid under load (P < 0.001) and significantly more strongly retained in the tooth roots (P < 0.005). The Parapost appears to be a mechanically superior post for the restoration of root-filled teeth with narrow diameter root canals.

Carbon↗

Design and solution structure of a partially rigid opioid antagonist lacking the basic center--models of antagonism.

To discriminate between two general models of antagonism (participation and allosteric), an opioid antagonist lacking the basic nitrogen of tyramine was designed and characterized. Cyclo-[Tyr(Me)2-Tic-], the diketopiperazine of 2,6-dimethyltyrosyl-1,2,3,4-tetrahydroisoquinoline-3-carboxylic acid, is a partially rigid opioid antagonist; its pA2 (5.8) is one smaller than that of N,N-bisallyl-enkephalin but it has a very high binding affinity (10 nM) and has a delta selectivity (66 with respect to the binding to mu receptors) higher than that of naltrindole. The conformational state of this diketopiperazine, studied under a variety of solvent and temperature conditions by NMR and molecular dynamics, can be described in terms of only three conformers whose relative populations vary widely with solvent. Only one of the three conformers, characterized by a 90 degree arrangement of the aromatic rings of Tyr(Me)2 and Tic similar to those of rigid agonists and of the bioactive conformation of the corresponding linear antagonist, is consistent with the antagonist activity. This finding favors the participation model among the general mechanisms proposed to explain antagonism. Due to the simple composition of the conformational mixture and to the rigidity of the molecule, it is possible to propose a quantitative explanation for the discrepancy between the very high binding affinity (10 nM) and the fairly small in mouse vas deferens value (1.5 microM).

Animals↗

A bitoric rigid contact lens with base down prism to eliminate binocular vertical diplopia.

Prism base down can be incorporated into a rigid gas permeable contact lens to align the diplopic images in a patient who has a significant vertical phoria. A rigid lens may also incorporate both vertical base down prism and a toroidal back surface - the vertical prism to correct the heterophoria and the toric back surface to improve the physical fit of the lens on a highly toric cornea. This paper presents a case where vertical diplopia due to a post-surgical left hyperphoria of about four prism dioptres was eliminated by the incorporation of the appropriate amount of base down vertical prism into a bitoric rigid gas permeable contact lens.

Contact Lenses↗

Rigid versus flexible cystoscopy. A controlled trial of patient tolerance.

The cost-efficiency and time-saving associated with out-patient flexible cystoscopy have propagated its use nationwide. However, only minimal attention has been paid to the feelings of patients exposed to this physically and emotionally invasive technique. We studied 53 consecutive patients attending for check cystoscopy at the time of their first flexible cystoscopy. Acting as their own historical controls, their feelings about rigid cystoscopy under general anaesthesia and subsequent flexible cystoscopy under local anaesthesia were assessed: 6/53 (11%) preferred rigid cystoscopy under general anaesthesia. The only significant association with their dislike of flexible cystoscopy, was their desire to stay in hospital overnight. It was concluded that with careful counselling and attention to individual needs, the preference for flexible cystoscopy over rigid cystoscopy under general anaesthesia can approach 100%.

Ambulatory Care↗

Nocturnal penile tumescence and rigidity evaluation in men with epilepsy.

PURPOSE: Men with epilepsy appear to have an approximately fivefold increase in risk of erectile dysfunction (ED). We attempted to determine whether ED in men with epilepsy was due to a physiological basis and whether erectile function could be adequately evaluated with an ambulatory nocturnal penile tumescence and rigidity monitor. METHODS: The physiologic integrity of the sexual response in men with epilepsy and ED was assessed with an ambulatory nocturnal penile tumescence and rigidity monitor (NPTR). Six men with localization-related epilepsy of temporal lobe origin (TLE) and ED, 2 men with TLE and normal sexual function, and 1 man with nonepileptic seizures (NES) and ED underwent evaluation of nocturnal erections for at least 2 nights. RESULTS: Five of 6 men with TLE and complaints of ED had abnormal ambulatory NPTR evaluations. All others had normal ambulatory NPTR. All abnormal evaluations showed reduced levels of rigidity, often with normal levels of tumescence. CONCLUSIONS: Previous studies have shown this abnormal ambulatory NPTR pattern to be associated with neurogenic rather than vasogenic ED. Therefore, epilepsy-related ED may have a substantial neurophysiologic component.

Adolescent↗

The accuracy of implant verification casts compared with casts produced from a rigid transfer coping technique.

PURPOSE: Prosthodontic techniques for implant-supported prostheses continue to evolve in an effort to facilitate treatment and minimize costs. Because research has shown no impression transfer technique to be without error, some clinicians have attempted to control the fit of prosthetic frameworks by reorienting sections of patterns or frameworks intraorally, fabricating a verification cast, and completing the prosthesis to fit such a cast. One manufacturer has attempted to meet both impression-making and verification-cast objectives by providing metallic impression copings (MICS) with extensions that allow contact between the copings for rigid fixation with acrylic resin before impression making. The purpose of this study was to determine the accuracy of casts produced from the MICS transfer process compared with casts produced from sectioned frameworks, where both techniques used a low-polymerization-shrinkage acrylic resin polymer to rigidly join the sections. MATERIALS AND METHODS: Using stainless steel measurement spheres as a reference point on each implant analog, the distances between analogs on the experimental casts were compared with the distances measured on the master cast. Seven casts were produced for each group and measured with a machinist's microscope at a 4-micron level of precision. RESULTS: The results revealed that the MICS transfer exhibited a mean error of 41 microns, which was significantly less than the verification-cast group mean error of 57 microns (p < .01, Student's t test). CONCLUSIONS: Given these results, clinicians can consider the rigid transfer technique as provided in the MICS transfer to be more accurate than the verification technique as outlined in this study.

Analysis of Variance↗

Modification of reserpine induced rigidity by dopaminergic and alpha-adrenergic drugs.

Previous studies have reported that a variety of drugs are effective in preventing reserpine-induced hypertonus, including dopamine agonists and alpha-adrenergic antagonists. The purpose of this study was to use a quantitative measure of hindlimb muscle tone to evaluate the relative efficacy of various drugs with known pharmacologic actions on dopaminergic and adrenergic receptors. The results show that adrenergic antagonists (yohimbine, thymoxamine, phentolamine, RS 21361) were the most effective in protecting against the effect of reserpine. Along with the dopamine precursor, 1-DOPA, these drugs were not only effective but also they produced no muscle relaxation in non-reserpinized rats. Although dopamine agonists (apomorphine, lisuride, bromocriptine) also protected against reserpine-induced rigidity, these drugs also produced muscle relaxation in non-reserpinized rats. A variety of drugs with alpha adrenergic agonist, beta adrenergic antagonist, dopamine antagonist and antihistamine activity did not alter the reserpine-induced rigidity despite generalized muscle relaxant effects with some of these. The results show that alpha adrenergic antagonists are the most selective agents in preventing reserpine-induced rigidity and suggest that alpha-2 receptors primarily mediate this effect.

Adrenergic alpha-Antagonists↗

Intracellular recording from spinal motoneurones in cats with post-asphyxial rigidity.

1. Intracellular recordings were obtained from lumbar spinal motoneurones in cats with post-asphyxial rigidity of the hind limbs.2. Membrane potentials, latencies and (or) appearance of excitatory post-synaptic potentials, initial segment responses and soma-dendritic spikes were not materially different from those observed in cells of normal cords.3. Dorsal root stimulation activated all the motoneurones examined through monosynaptic pathways in contrast to cells in normal cords in which such a stimulus sometimes elicits only a post-synaptic potential. In a number of cells subsequent polysynaptic activation caused a spike about 10 msec after the monosynaptic response, notwithstanding the serious interneuronal destruction which characterized these preparations.4. In a few preparations the effects of acute asphyxiation could be examined. The soma depolarized at a rate of 3-4 mV/min. Synaptic activation was more resistant to O(2) lack than antidromic and direct excitation, in contrast to the experience with normal cells. Survival times of 8.5, 11 and 16 min were found. At certain levels of depolarization ;spontaneous' spikes were observed, which, since they were preceded by post-synaptic potentials, could be considered as the result of synaptic activation.5. To account for the enhanced reflex activity of rigid preparations, it was postulated that the substantial loss of interneurones in the cord had caused denervation supersensitivity of the motoneurones to the transmitter compound without materially changing their electrical excitability.6. It was postulated that the early presynaptic failure during asphyxiation in normal preparations was dependent on a mechanism resembling presynaptic inhibition. The prolonged asphyxial survival of reflex activity in rigid preparations may be due to the destruction of interneurones involved in this form of inhibition.

Animals↗

Hemodynamic aspects of obliterative processes in peripheral blood vessel--rigid and soft narrowing.

Hemodynamic aspects of obliterative processes in peripheral blood vessels were studied on a mechanical model built of distensible tubing, with a fixed peripheral resistance, through which citrated blood was circulated by pulsatile flow. Hemodynamics of progressive focal stenosis, elongated soft stenosis, and elongated rigid stenosis were assessed. By the use of a hydrodynamic model and a series of in vitro experiments, we have measured the pressure and flow characteristics, and calculated the pressure and energy losses for the various stenotic sites. The critical stricture was found to be larger for a rigid stenosis than a soft stenosis. The length of the stenosis was also an important factor. Increasing the length of a rigid stenosis, for example, by 50 percent resulted in an increase of 25 percent in the flow through the stenosis. The energy dissipation was determined as a preferred indication for several parameters such as: pressure drop, pulsed flow, pulse rate, and the geometry and mechanical properties of the stenosis.

Arterial Occlusive Diseases↗

One-dimensional computer analysis of oscillatory flow in rigid tubes.

The dynamic characteristics of catheter-transducer systems using rigid tubes with compliance lumped in the transducer and oscillatory flow of fluid in rigid tubes were analyzed. A digital computer model based on one dimensional laminar oscillatory flow was developed and verified by exact solution of the Navier-Stokes Equation. Experimental results indicated that the damping ratio and resistance is much higher at higher frequencies of oscillation than predicted by the one dimensional model. An empirical correction factor was developed and incorporated into the computer model to correct the model to the experimental data. Amplitude of oscillation was found to have no effect on damping ratio so it was concluded that the increased damping ratio and resistance at higher frequencies was not due to turbulence but to two dimensional flow effects. Graphs and equations were developed to calculate damping ratio and undamped natural frequency of a catheter-transducer system from system parameters. Graphs and equations were also developed to calculate resistance and inertance for oscillatory flow in rigid tubes from system parameters and frequency of oscillation.

Blood Flow Velocity↗

An experimental study of pressure losses in pulsatile flows through rigid and pulsating stenosis.

The time-dependent pressure curves of a pulsatile flow across rigid and pulsating stenoses were investigated experimentally in a laboratory simulator of the outflow tract of the heart right ventricle. The experiments were performed within the range of physiological conditions of frequency and flow rate. The experimental setup consisted of a closed flow system which was operated by a pulsatile pump, and a test chamber which enabled checking different modes of stenosis. Rigid constrictions were simulated by means of axisymmetric blunt-ended annular plugs with moderate-to-severe area reductions. The pulsating stenosis consisted of a short starling resistor device operated by a pulsating external pressure which was synchronized by the pulsatile flow. It was found that the shape of the time-dependent pressure curve upstream of the stenosis was different in the case of rigid stenosis than in the pulsating one. Potential clinical applications of the work may relate to diagnosis of the type of stenosis in the congenital heart disease known as Tetralogy of Fallot.

Biomechanical Phenomena↗

Measurement of the extensional and flexural rigidities of a subcellular structure: marginal bands isolated from erythrocytes of the newt.

The elastic properties of marginal band, a microtubular structure isolated from the newt (notophthalmus viridescens) have been measured. Bands were isolated using Triton X-100 and pepsin at pH 6.8 according to the method of Cohen (1978). Isolated bands were manipulated with a glass microhook in a buffer-filled chamber under the microscope. Single bands were stretched between the hook and a thin glass fiber. The fiber was calibrated so that the force on the band could be calculated from the displacement of the fiber. The data pairs of force versus band deflection were analyzed according to the theoretical work of Libai and Simmonds (1983) to obtain the flexural and extensional rigidities of the band. Band dimensions calculated from the data were consistent with microscopically determined values. The average flexural rigidity of the bands (EI) was 5.3 X 10(-13) dyn X cm2 and the average extensional rigidity (EA) was 0.017 dyn. Compared to the cell membrane, the marginal band is nearly inextensible and has a much greater resistance to bending, indicating that the band makes an important contribution to the deformability of the circulating cell.

Animals↗