Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Models, Cardiovascular”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Power spectral density of unevenly sampled data by least-square analysis: performance and application to heart rate signals.

This work studies the frequency behavior of a least-square method to estimate the power spectral density of unevenly sampled signals. When the uneven sampling can be modeled as uniform sampling plus a stationary random deviation, this spectrum results in a periodic repetition of the original continuous time spectrum at the mean Nyquist frequency, with a low-pass effect affecting upper frequency bands that depends on the sampling dispersion. If the dispersion is small compared with the mean sampling period, the estimation at the base band is unbiased with practically no dispersion. When uneven sampling is modeled by a deterministic sinusoidal variation respect to the uniform sampling the obtained results are in agreement with those obtained for small random deviation. This approximation is usually well satisfied in signals like heart rate (HR) series. The theoretically predicted performance has been tested and corroborated with simulated and real HR signals. The Lomb method has been compared with the classical power spectral density (PSD) estimators that include resampling to get uniform sampling. We have found that the Lomb method avoids the major problem of classical methods: the low-pass effect of the resampling. Also only frequencies up to the mean Nyquist frequency should be considered (lower than 0.5 Hz if the HR is lower than 60 bpm). We conclude that for PSD estimation of unevenly sampled signals the Lomb method is more suitable than fast Fourier transform or autoregressive estimate with linear or cubic interpolation. In extreme situations (low-HR or high-frequency components) the Lomb estimate still introduces high-frequency contamination that suggest further studies of superior performance interpolators. In the case of HR signals we have also marked the convenience of selecting a stationary heart rate period to carry out a heart rate variability analysis.

Cardiac Pacing, Artificial↗

State transitions in physiologic systems: a complexity model for loss of consciousness.

Complex physiologic systems in which the emergent global (observable) behavior results from the interplay among local processes cannot be studied effectively by conventional mathematical models. In contrast to traditional computational methods which provide linear or nonlinear input-output data mapping without regard to the internal workings of the system, complexity theory offers scientifically and computationally tractable models which take into account microscopic mechanisms and interactions responsible for the overall input-output behavior. This article offers a brief introduction to some of the tenets of complexity theory and outlines the process involved in the development and testing of a model that duplicates the global dynamics of the induction of loss of consciousness (LOC) in humans due to cerebral ischemia. Under the broad definition of complexity, we view the brain of humans as a complex system. Successful development of a model for this complex system requires careful combination of basic knowledge of the physiological system both at the local (microscopic) and global (macroscopic) levels with experimental data and the appropriate mathematical tools. It represents an attempt to develop a model that can both replicate human data and provide insights about possible underlying mechanisms.

Acceleration↗

The effect of artifact rejection by signal-space projection on source localization accuracy in MEG measurements.

The consequences of artifact suppression by means of signal-space projection on dipole localization accuracy for magnetoencephalography measurements are studied. Approximate analytical formulas, equivalent to the Cramer-Rao bound, are presented and verified by Monte Carlo simulations which relate the increase of localization error for individual coordinates to the similarity of the artifact field and respective (contravariant) quadrupole fields obtained by differentiating the dipole field with respect to its origin. The expressions simplify significantly for dipoles placed below the center of the measuring system giving rise to highly symmetric field patterns. Formulas are presented both for single- and for multiple-artifact rejection. As illustrative examples artifact fields are constructed which a) lead to highly decreasing signal-to-noise ratio and goodness-of-fit (GOF), while the localization error is unaffected for all coordinates and b) lead to an increase of localization error while the SNR and the GOF stays constant. Finally, the rich structure of localization error increase is demonstrated for a class of artifact fields originating from artifact current dipoles.

Artifacts↗

New statistical method for detection and quantification of respiratory sinus arrhythmia.

A statistical method with the advantages of 1) enabling graphical representation of within-respiratory cycle heart rate variations, 2) detecting the presence of respiratory sinus arrhythmia (RSA) in a moving window, and 3) providing breath-by-breath RSA amplitude and phase obtained from the fitting of a sinusoid to the instantaneous relative heart rate is presented.

Adolescent↗

A fast and simple algorithm for the calculation of convective heat transfer by large vessels in three-dimensional inhomogeneous tissues.

A fast and simple algorithm has been presented for the calculation of time-dependent temperature distributions in inhomogeneous vascularized tissue. Three-dimensional anatomical data of tissues and vessel structures are decomposed into elementary cubic nodes by a special digitizing routine with vessels represented by connected strings of vessel nodes. Vessel cross sections may be irregular shaped and/or tapered. Conductive and convective heat transfer was calculated through use of the heat balance technique on each cubic node resulting in an explicit finite difference computational scheme. Employing a three time level scheme, the Fourier stability criterion is circumvented allowing arbitrary time steps to be defined in the algorithm. Time steps as large as 100 times the Fourier restricted one still result in stable and convergent calculations of the stationary temperature distribution. Vessels with different flows and diameters are incorporated by performing a vessel specific second discretization step in time. Using the new algorithm as a mathematical tool the thermal equilibration length of vessel segments have been established under a broad range of geometrical and flow conditions. Validation followed from comparing transient and stationary temperature distributions derived by the proposed algorithm to those from an accurate cylindrical numerical model. Predicted values for the thermal equilibration lengths are compared to an analytical expression and phantom experiments. The algorithm is incorporated in a thermal model being the main part of our hyperthermia treatment planning system.

Algorithms↗

Classification of electrocardiographic P-wave morphology.

The atrial activity of the human heart is normally visible in the electrocardiogram as a P-wave. In patients with intermittent atrial fibrillation, a different P-wave morphology can sometimes be seen, indicating atrial conduction defects. The purpose of this study was to develop a method to discriminate between such P-waves and normal ones. 20 recordings of each type were used in a classification which, based on impulse response analysis of the P-wave and linear discrimination between various parameters, produced a correct classification in 37 of the 40 recordings (sensitivity 95%, specificity 90%).

Atrial Fibrillation↗

Do existing measures of Poincaré plot geometry reflect nonlinear features of heart rate variability?

Heart rate variability (HRV) is concerned with the analysis of the intervals between heartbeats. An emerging analysis technique is the Poincaré plot, which takes a sequence of intervals and plots each interval against the following interval. The geometry of this plot has been shown to distinguish between healthy and unhealthy subjects in clinical settings. The Poincaré plot is a valuable HRV analysis technique due to its ability to display nonlinear aspects of the interval sequence. The problem is, how do we quantitatively characterize the plot to capture useful summary descriptors that are independent of existing HRV measures? Researchers have investigated a number of techniques: converting the two-dimensional plot into various one-dimensional views; the fitting of an ellipse to the plot shape; and measuring the correlation coefficient of the plot. We investigate each of these methods in detail and show that they are all measuring linear aspects of the intervals which existing HRV indexes already specify. The fact that these methods appear insensitive to the nonlinear characteristics of the intervals is an important finding because the Poincaré plot is primarily a nonlinear technique. Therefore, further work is needed to determine if better methods of characterizing Poincaré plot geometry can be found.

Analysis of Variance↗

A spline Laplacian ECG estimator in a realistic geometry volume conductor.

We have developed a spline-based Laplacian estimator over an arbitrarily shaped surface of a volume conductor and tested its applicability to Laplacian electrocardiogram (ECG) mapping. In the newly developed algorithm, estimation of the parameters associated with the spline Laplacian is formulated by seeking the general inverse of a transfer matrix. Only one spline-parameter needs to be determined through regularization in order to estimate the realistic geometry surface Laplacian from the body surface potentials. It has been demonstrated that the rich knowledge on regularization in the inverse problems can be directly applied to estimate the spline Laplacian ECG (LECG), such as the discrepancy principle. Computer simulations have been conducted to validate the new approach in a spherical volume conductor and test the feasibility of mapping cardiac electrical sources in a realistic geometry heart-torso model. The present results demonstrate that the realistic geometry spline LECG can be estimated conveniently from the body surface potentials, is more robust against measurement noise and has better performance than the conventional five-point local Laplacian estimator.

Algorithms↗

Error analysis of tissue resistivity measurement.

We identified the error sources in a system for measuring tissue resistivity at eight frequencies from 1 Hz to 1 MHz using the four-terminal method. We expressed the measured resistivity with an analytical formula containing all error terms. We conducted practical error measurements with in-vivo and bench-top experiments. We averaged errors at all frequencies for all measurements. The standard deviations of error of the quantization error of the 8-bit digital oscilloscope with voltage averaging, the nonideality of the circuit, the in-vivo motion artifact and electrical interference combined to yield an error of +/- 1.19%. The dimension error in measuring the syringe tube for measuring the reference saline resistivity added +/- 1.32% error. The estimation of the working probe constant by interpolating a set of probe constants measured in reference saline solutions added +/- 0.48% error. The difference in the current magnitudes used during the probe calibration and that during the tissue resistivity measurement caused +/- 0.14% error. Variation of the electrode spacing, alignment, and electrode surface property due to the insertion of electrodes into the tissue caused +/- 0.61% error. We combined the above errors to yield an overall standard deviation error of the measured tissue resistivity of +/- 1.96%.

Animals↗

A shape-space-based approach to tracking myocardial borders and quantifying regional left-ventricular function applied in echocardiography.

This paper presents a new semi-automatic method for quantifying regional heart function from two-dimensional echocardiography. In the approach, we first track the endocardial and epicardial boundaries using a new variant of the dynamic snake approach. The tracked borders are then decomposed into clinically meaningful regional parameters, using a novel interpretational shape-space motivated by the 16-segment model used in clinical practice for qualitative assessment of heart function. We show how a quantitative and automatic scoring scheme for the endocardial excursion and myocardial thickening can be derived from this. Results illustrating our approach on apical long-axis two-chamber-view data from a patient with a myocardial infarct in the apical anterior/inferior region of the heart are presented. In a case study (five patients, nine data sets) the performance of the tracking and interpretation techniques are compared with manual delineations of borders using a number of quantitative measures of regional comparison.

Algorithms↗