Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Borate-nucleotide complex formation depends on charge and phosphorylation state.

Flow injection analysis with electrospray ionization mass spectrometry was used to investigate borate-nucleotide complex formation. Solutions containing 100 microM nucleotide and 500 microM boric acid in water-acetonitrile-triethylamine (50:50:0.2, v/v/v; pH 10.3) showed that borate complexation with nicotinamide nucleotides was significantly influenced by the charge on the nicotinamide group and the number of phosphate groups on the adenine ribose. Borate binding decreased in the order of NAD(+), NADH, NADP(+) and NADPH. To investigate the relationship between complex formation and phosphorylation, association constants (K(A)) of borate-adenine (AMP, ADP, ATP), -guanine (GMP, GDP, GTP), -cytidine (CMP, CDP, CTP) and -uridine (UMP, UDP, UTP) complexes were compared. The results showed that the number of nucleotide phosphate groups was inversely proportional to the relative abundance of the borate complexes, with the K(A) of borate-nucleotide complex decreasing in the order mono-, di- and tri-phosphates (AMP approximately GMP approximately CMP approximately UMP > ADP approximately GDP approximately CDP approximately UDP > GTP > ATP approximately CTP approximately UTP). At pH 7.4, using ammonium bicarbonate buffer, only borate-NAD(+) complex was observed. This indicates that the borate-NAD(+) complex may be the most physiologically relevant of those studied.

Borates↗

Monitoring arterio-venous differences of glucose and lactate in the anesthetized rat with or without brain damage with ultrafiltration and biosensor technology.

Continuous monitoring of arterio-venous glucose and lactate differences may serve as a diagnostic tool to assess normal brain function and brain pathology. We describe a method and some results obtained with arterio-venous measurements of glucose and lactate in the blood of the halothane-anesthetized rat and after brain injury. The method is based on low flow rate ultrafiltration for continuous collection of blood filtrate combined with flow injection analysis and biosensors for the detection of glucose and lactate. We measured the glucose and lactate concentration every minute in the jugular vein and the aorta at control conditions and during and after inflation of an embolectomy-balloon for 2 min. Net cerebral lactate efflux and glucose uptake was seen under control conditions and at low blood lactate levels. During brain injury both lactate release and glucose uptake were reduced and there was a net lactate influx at high arterial lactate levels. These results indicate that the flux of lactate in and out of the brain is not only dependent on the lactate concentration in the brain, but on blood levels as well, possibly because of bi-directional flux through the monocarboxylate transporter type 1.

Anesthetics↗

A severe peak tailing of phosphate compounds caused by interaction with stainless steel used for liquid chromatography and electrospray mass spectrometry.

A severe peak tailing was observed for adenosine 5'-monophosphate in flow injection analysis with stainless steel tubing and water/methanol mixture (1:1, v/v) as carrier. The cause of the peak tailing was investigated by focusing on the chemical structure of the analytes, the material used for the analytical systems and the composition of the carrier. We clarified that the peak tailing was caused by the interaction between phosphate residues in the analytes and stainless steel. The severe peak tailing did not occur with stainless steel tubing when the phosphate compounds were analyzed with carrier containing phosphoric acid or phosphate buffer. The findings indicate that such ill peak profiles are usually not considerable in conventional HPLC separation because phosphoric acid or phosphate buffer is quite commonly used in eluents. In LC-MS, however, the use of phosphoric acid and phosphate buffer is usually avoided because of their non-volatility; therefore this interaction between stainless steel and phosphate compound becomes predominant and results in severe peak tailings. We also found an effective method for avoiding the interaction. When stainless parts, such as LC tubing and ESI spray capillary, were treated with phosphoric acid prior to analysis, the peak profiles of the phosphate compounds were dramatically improved, even when non-phosphate buffer is used as carrier.

Chromatography, Liquid↗

Liquid chromatography-electron ionization mass spectrometry: fields of application and evaluation of the performance of a Direct-EI interface.

A comprehensive evaluation and a thorough discussion of the fields of possible applications of the Direct-EI interface are described in this review. Direct-EI allows the direct introduction of the effluent from a capillary HPLC column into the electron ionization (EI) ion source of a mass spectrometer. Thanks to the reduced liquid intake and an in-source nebulizer, the interfacing process occurs smoothly and entirely into the ion source. No intermediate interfacing mechanisms of any sort are interposed between the column and the mass spectrometer, thus circumventing any undesired sample loss and minimizing the effort for instrument modification. Theoretically, any GC-MS system can be converted into an LC-MS for EI amenable compounds. Several parameters, crucial for a successful integration of liquid chromatography and mass spectrometry, have been considered in the evaluation of the functioning of such an interface: limit of detection, linearity of response, reproducibility, and chromatographic compatibility. Different mobile phases, also containing non-volatile buffers, were taken into account, demonstrating an outstanding separation flexibility. The entire set of experiments was carried out at different flow rates and temperatures of the ion source. The interface behavior was also tested in real world applications, with mixtures of pesticides, hormones, nitro-PAH, and endocrine-disrupting compounds, allowing picogram level detection and the possibility to record library-matchable, readily interpretable electron ionization mass spectra, for prompt compound characterization and confirmation.

Chromatography, High Pressure Liquid↗

A portable automated system for trace gas sampling in the field and stable isotope analysis in the laboratory.

A computer-controllable mobile system is presented which enables the automatic collection of 33 air samples in the field and the subsequent analysis for delta13C and delta18O stable isotope ratios of a carbon-containing trace gas in the laboratory, e.g. CO2, CO or CH4. The system includes a manifold gas source input for profile sampling and an infrared gas analyzer for in situ CO2 concentration measurements. Measurements of delta13C and delta18O of all 33 samples can run unattended and take less than six hours for CO2. Laboratory tests with three gases (compressed air with different pCO2 and stable isotope compositions) showed a measurement precision of 0.03 per thousand for delta13C and 0.02 per thousand for delta18O of CO2 (standard error (SE), n = 11). A field test of our system, in which 66 air samples were collected within a 24-hour period above grassland, showed a correlation of 0.99 (r2) between the inverse of pCO2 and delta13C of CO2. Storage of samples until analysis is possible for about 1 week; this can be an important factor for sampling in remote areas. A wider range of applications in the field is open with our system, since sampling and analysis of CO and CH4 for stable isotope composition is also possible. Samples of compressed air had a measurement precision (SE, n = 33) of 0.03 per thousand for delta13C and of 0.04 per thousand for delta18O on CO and of 0.07 per thousand for delta13C on CH4. Our system should therefore further facilitate research of trace gases in the context of the carbon cycle in the field, and opens many other possible applications with carbon- and possibly non-carbon-containing trace gases.

Carbon Dioxide↗

Improved precision and accuracy for high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometric exact mass measurement of small molecules from the simultaneous and controlled introduction of internal calibrants via a second electrospray nebuliser.

The use of a second electrospray nebuliser has proved to be highly successful for exact mass measurement during high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometry (HPLC/FTICRMS). Much improved accuracy and precision of mass measurement were afforded by the introduction of the internal calibration solution, thus overcoming space charge issues due to the lack of control over relative ion abundances of the species eluting from the HPLC column. Further, issues of suppression of ionisation, observed when using a T-piece method, are addressed and this simple system has significant benefits over other more elaborate approaches providing data that compares very favourably with these other approaches. The technique is robust, flexible and transferable and can be used in conjunction with HPLC, infusion or flow injection analysis (FIA) to provide constant internal calibration signals to allow routine, accurate and precise mass measurements to be recorded.

Calibration↗

Determination of proanthocyanidins in fresh grapes and grape products using liquid chromatography with mass spectrometric detection.

Fresh grapes and grape products, such as grape wine and grape juice, were analyzed for proanthocyanidins (PACs) using liquid chromatography with electrospray ionization mass spectrometric (MS) detection. PACs were successfully separated and analyzed on the basis of their protonated molecules, allowing the identification of PACs in different degrees of polymerization from monomers to oligomers (up to 7 units), and in various isomeric forms. Using reversed-phase high-performance liquid chromatography (HPLC) combined with MS detection, the PAC monomers, (+)-catechin (C), (-)-epicatechin (EC), (-)-catechin gallate (CG), and (-)-epicatechin gallate (ECG), were successfully quantified using selected ion monitoring (SIM) mode. Standard curves were fitted for each PAC ranging from 43.8 to 5600 ng/mL for C, from 42.2 to 5400 ng/mL for EC, from 36.7 to 4700 ng/mL for CG, and from 39.8 to 5100 ng/mL for ECG. Good linearity (r2>0.999) was achieved for each analyte. The accuracy and precision (RSD) were within 10% (n=8) at the limit of detection. This method allows direct quantification of monomeric PACs in fresh grapes and grape-derived products. Additionally, flow injection analysis (FIA) was applied to estimate the concentration levels of PAC oligomers by comparing their FIA-MS peak areas, which were well correlated (r2=0.936) to the total concentrations of PAC monomers.

Chromatography, Liquid↗

High-precision, automated stable isotope analysis of atmospheric methane and carbon dioxide using continuous-flow isotope-ratio mass spectrometry.

Small-scale developments have been made to an off-the-shelf continuous-flow gas chromatography/isotope-ratio mass spectrometry (CF-GC/IRMS) system to allow high-precision isotopic analysis of methane (CH(4)) and carbon dioxide (CO(2)) at ambient concentrations. The repeatability (1sigma) obtainable with this system is 0.05 per thousand for delta(13)C of CH(4), 0.03 per thousand for delta(13)C of CO(2), and 0.05 per thousand for delta(18)O of CO(2) for ten consecutive analyses of a standard tank. An automated inlet system, which allows diurnal studies of CO(2) and CH(4) isotopes, is also described. The improved precision for CH(4) analysis was achieved with the use of a palladium powder on quartz wool catalyst in the combustion furnace, which increased the efficiency of oxidation of CH(4) to CO(2). The automated inlet further improved the precision for both CH(4) and CO(2) analysis by keeping the routine constant. The method described provides a fast turn-around in samples, with accurate, reproducible results, and would allow a long-term continuous record of CH(4) or CO(2) isotopes at a site to be made, providing information about changing sources of the gases both seasonally and interannually.

Air Pollution↗

Ultra-low flow nanospray for the normalization of conventional liquid chromatography/mass spectrometry through equimolar response: standard-free quantitative estimation of metabolite levels in drug discovery.

Nanospray experiments were performed on an ensemble of drug molecules and their commonly known metabolites to compare performance with conventional electrospray ionization (ESI) and to evaluate equimolar response capabilities. Codeine, dextromethorphan, tolbutamide, phenobarbital, cocaine, and morphine were analyzed along with their well-known metabolites that were formed via hydroxylation, dealkylation, hydrolysis, and glucuronidation. Nanospray exhibited a distinct trend toward equimolar response when flow rate was reduced from 25 nL/min to less than 10 nL/min. A more uniform response between the parent drug and the corresponding metabolites was obtained at flow rates of 10 nL/min or lower. The largest discrepancy was within +/-50% for plasma samples. Nanospray was used as a calibrator for conventional ESI liquid chromatography/tandem mass spectrometry (LC/MS/MS) and normalization factors were applied to the quantitation of an acyl-glucuronide metabolite of a proprietary compound in rat plasma. A nanospray calibration method was developed with the standard curve of the parent drug to generate quantitative results for drug metabolites within +/-20% of that obtained with reference standards and conventional ESI. The nanospray method provides a practical solution for the quantitative estimation of drug metabolites in drug discovery when reference standards are not available.

Calibration↗

Continuous shipboard sampling system for determination of triple oxygen isotopes and O2/Ar ratio by dual-inlet mass spectrometry.

A continuous shipboard sampling system was developed for the determination of the isotopic composition of the triple oxygen isotopes and oxygen to argon (O(2)/Ar) ratios in dissolved air. In this system, dissolved air is separated by a hollow fiber membrane degassing module. This system collects dissolved air quantitatively and rapidly. The sample flow rate through the membrane is critical for the fractionation of the oxygen isotopes and the O(2)/Ar ratio and should be < 2 mL/min. Fractionation of oxygen between the liquid and gas phase of the air-saturated water was found to be similar to that of earlier reports. The advantages of this method over existing techniques include rapid collection of samples (30 min/sample), high efficiency in extraction of gases from the liquid phase, and the lack of a sample preparation step (e.g. degassing).

Argon↗

A rapid, automated approach to optimisation of multiple reaction monitoring conditions for quantitative bioanalytical mass spectrometry.

An improvement to the procedure for the rapid optimisation of mass spectrometry (PROMS), for the development of multiple reaction methods (MRM) for quantitative bioanalytical liquid chromatography/tandem mass spectrometry (LC/MS/MS), is presented. PROMS is an automated protocol that uses flow-injection analysis (FIA) and AppleScripts to create methods and acquire the data for optimisation. The protocol determines the optimum orifice potential, the MRM conditions for each compound, and finally creates the MRM methods needed for sample analysis. The sensitivities of the MRM methods created by PROMS approach those created manually. MRM method development using PROMS currently takes less than three minutes per compound compared to at least fifteen minutes manually. To further enhance throughput, approaches to MRM optimisation using one injection per compound, two injections per pool of five compounds and one injection per pool of five compounds have been investigated. No significant difference in the optimised instrumental parameters for MRM methods were found between the original PROMS approach and these new methods, which are up to ten times faster. The time taken for an AppleScript to determine the optimum conditions and build the MRM methods is the same with all approaches.

Albuterol↗

Investigation of cytolysin variants by peptide mapping: enhanced protein characterization using complementary ionization and mass spectrometric techniques.

Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) have been used in conjunction with time-of-flight (TOF) and quadrupole ion trap (IT) mass spectrometry, respectively, to analyze various cytolysin proteins isolated from the sea anemone Stichodactyla helianthus and digested by the protease trypsin. By employing different ionization methods, the subsequent changes in ionization selectivity for the peptides in the digested protein samples resulted in ion abundance variation reflected in the mass spectra. Upon investigation of this variation generated by the two ionization processes, it has been shown in this study that enhanced protein coverage (e.g., >95% for cytolysin III) can be achieved. Additionally, capillary and microbore reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with ESI mass spectrometry (MS) as well as flow injection analysis by nanoflow ESI-MS afforded the necessary limit of detection (LOD) for detailed structural information of the cytolysin proteins by tandem mass spectrometry (MS/MS) methods. It can be concluded that cytolysins II and III correspond to sticholysins I and II, that "cytolysin I" is a mixture of modified forms of cytolysins II and III, and that "cytolysin IV" is an incompletely processed precursor of cytolysin III.

Amino Acid Sequence↗

Identification and quantification of in vitro adduct formation between protein reactive xenobiotics and a lysine-containing model peptide.

Formation of in vitro adducts between different classes of xenobiotics and the lysine-containing peptide Lys-Tyr was monitored by high-performance liquid chromatography and electrospray ionization mass spectrometry. The molecular structures of the main resulting products could be sensitively analyzed by mass spectrometry (flow injection analysis), enabling the detection of characteristic binding formations. Aldehydes such as formaldehyde, acetaldehyde, and benzaldehyde were shown to form stable linkages to lysine amino groups via Schiff bases. Other electrophilic substances (e.g., toluene-2,4-diisocyanate, 2,4-dinitro-1-fluorobenzene, 2,4,6-trinitrobenzene sulfonic acid, dansyl chloride, and phthalic acid anhydride) also formed covalent adducts with lysine residues. The reactivity of the compounds was quantified by measuring the amount of peptide that remained unchanged after incubation for a certain period with the xenobiotic. Although reactivity levels within this group of aldehydes varied only to a small extent, as would be expected, extreme differences were seen among the structurally heterogeneous group of nonaldehyde xenobiotics. These results support the hypothesis that simple chemical reactions may lead to the adduction of nucleophilic macromolecules such as peptides or proteins. Such reactions, in particular, Schiff base formation of aldehydes, have previously been shown to be capable of specifically interfering with costimulatory signaling on T cells. Our results suggest that electrophilic xenobiotics of other classes may also inherit the capacity to exert similar effects. Forming covalent linkage to peptides may represent a possible molecular mechanism of electrophilic xenobiotics in vivo, yielding immunotoxic effects. The model utilized in this study is appropriate for monitoring the adduction of xenobiotics to basic peptides and for analyzing the resulting molecular structures.

Aldehydes↗

Studies on the rate and control of antibody oxidation by periodate.

The oxidation of antibody carbohydrate residues by periodate is a common approach for the site-specific immobilization or modification of antibodies for use in various bioanalytical methods. This study examined the time dependence of this oxidation process under a variety of pH, temperature, and concentration conditions. Polyclonal rabbit immunoglobulin G (IgG)was used as the model system for these studies. Flow-injection analysis and a hydrazide label (Lucifer yellow CH) were used to monitor the progress of the oxidation reaction. It was found that the number of oxidized sites that were available for labeling could be varied between one and eight groups per antibody by adjusting the time, pH, periodate concentration, or reaction temperature. In each case, most of these groups were produced during the first 30-60 min of the reaction. A comparison was made between these results and those of previous studies that have examined the effects of periodate treatment on amino acid residues and antibody activity. From this work, general guidelines were developed for the control and optimization of antibody oxidation for use with assays that require either high or low levels of antibody modification.

Animals↗

Determination of galactose and galactocerebroside using a galactose oxidase column and electrochemical detector.

A method has been developed to measure galactose and galactocerebroside using galactose oxidase immobilized on a solid resin. Galactose oxidase converts galactose and galactocerebroside to their corresponding aldehydes and hydrogen peroxide, the latter being electroactive and measurable by electrochemical detection using DC amperometric detection. The minimal detection limits of galactose and galactocerebroside were 1 and 2 microM, respectively. The linear response to galactose and galactocerebroside was to at least 300 microM. About 100 samples can be measured per hour using flow injection analysis. The activity of sulfatidase (cerebroside-3-sulfate-3-sulfohydrolase), which converts sulfatide (sulfogalactocerebroside) to galactocerebroside, was measured, and its inhibition by O-phospho-L-tyrosine was determined.

Biosensing Techniques↗

Electrochemical behavior and electrocatalytic study of the methylene green coated on modified silica gel.

The electrochemical behavior of methylene green (MG) adsorbed on a silica surface modified with niobium oxide (SN) was investigated, using modified carbon paste electrodes. It was also used in an electrocatalytic study of NADH oxidation. The electrode showed a high stability attributed to the presence of SN, which avoids the leaching of the mediator from the electrode surface. The formal potential (E(0')) of the adsorbed MG was -35 mV vs SCE, showing a shift of 30 mV toward more positive potential values, compared to the MG dissolved in aqueous solution. This shift was assigned to the interaction between the basic nitrogen of MG and the acid sites of SN. The variation of the solution pH between 4 and 8 did not affect the stability nor the formal potential. However, for solution pH lower than 4 the formal potential was affected by the acidity of the medium. The electrocatalytic oxidation of NADH at the electrode was investigated. In the solution pH between 5 and 8 the electrocatalytic activity remained almost constant, giving a response signal of 13.3 nA L micromol(-1) cm(-2) and a K(Mapp) of 1.4 x 10(-5) mol L(-1). The electrode gave a linear response range between 5.0 x 10(-4) and 4.0 x 10(-3) mol L(-1) NADH concentration at pH 7.0 at an applied potential of 50 mV vs SCE. Applying a flow injection analysis system, the electrode showed a better analytical performance for NADH detection, presenting a linear response range between 6.0 x 10(-5) and 1.0 x 10(-3) mol L(-1), with an analytical frequency of 30 determinations/h, a detection limit of 8.2 x 10(-6) mol L(-1), and a precision for 25 replicates of 1% expressed as a relative standard deviation.

Catalysis↗

Reevaluation of the Griess method for determining NO/NO2- in aqueous and protein-containing samples.

Nitric oxide (NO) is an important intracellular and extracellular signal substance. Nitrite is one product of the oxidative metabolism of NO. The purpose of this study was to establish a simple method of determining nitrite (NO2-) to provide a means of estimating the endogenous formation of NO or NO2-. A flow injection analysis (FIA) based on the Griess reaction was developed for this purpose. Using a standard additive method, it is possible to eliminate matrix effects such as those that can occur in samples containing protein. This measuring method is suitable for measurements in effluates or protein-rich cellular supernatants. The sensitivity of the method is 2 nmol/L for samples in aqueous phases and 8 nmol/L for protein-containing phases. The two-point discrimination is 2 nmol/L. A linear correlation between nitrite and signal level can be demonstrated over a range of 0.002-5 micromol/L. Reproducibility, including sample preparation and analysis, can be specified with a coefficient of variation (C.V.) of 6.7%. Day-to-day variability for identical samples 0.8% (C.V.). This study presents examples of the application of this method (measurements in blood samples and in isolated perfused hearts) and compares them to established methods of measuring NO and NO2. We found the FIA method to be equally sensitive as NO measurement by means of oxyhemoglobin assay. The FIA method is seven times more sensitive than HPLC methods, and its design is significantly simpler. Compared to the traditional Griess method, its sensitivity is higher by a factor of 500. With its high sensitivity, high reproducibility, and its unsurpassed low susceptibility to interference, this method of analysis provides a means of reliably determining nitrite concentration as a marker of NO formation in various matrices. Therefore, it can be a valuable instrument in experimental and clinical studies to determine the physiologic and pathophysiologic relevance of NO.

Chromatography, High Pressure Liquid↗