Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Finite Element Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Finite-element modeling of the synthetic intervertebral disc.

An ideal and realistic finite-element analysis should include several factors, such as geometry (shape and size), the relative volumes of the nucleus to the anulus fibrosus, the fiber volume fraction within the anulus, and material properties. In this study, a finite-element analysis model for the disc that included these factors was developed. In addition, synthetic disc prostheses with the same specifications of geometry and material properties were manufactured. The developed model was found to be reliable and accurate when finite-element analysis results were compared with experimental synthetic disc data. The model also matched the mechanical behavior of the natural disc. This finite-element analysis model provides a tool to study the mechanical behavior of discs with varying degrees and types of injury and degeneration.

Biomechanical Phenomena↗

Finite element analyses of two antirotational designs of implant fixtures.

The purpose of this study was to compare the effect of cyclic compressive forces on loosening of the abutment retaining screw of dental implant fixtures with two different antirotational designs using the finite element analysis. A three-dimensional model of externally hexed and trichannel dental implant fixtures with their corresponding abutments and retaining screws was developed. Comparison between the two designs was carried out using finite element analysis. The results revealed that the externally hexed design has significantly higher overall stress, contact stress, and deflection compared with the trichannel design. The trichannel antirotational design has the least potential for fracture of the implant/abutment assembly in addition to its capability for preventing rotation of the prosthesis and loosening of the screw.

Dental Abutments↗

Dynamic evaluation of the viscoelastic properties of a biomedical polymer (biomer).

This paper deals with the experimental determination of the dynamic constants, storage and loss moduli of a viscoelastic material currently used as membranes in the artificial heart or other types of cardiac bypass pumps. A brief discussion of the viscoelastic theory is given, starting with the relaxation and creep function leading to the determination of the stress-strain relationship in integral equation form. It is shown that when dealing with periodical strain histories, the integral equation form may be reduced to a complex form. The complex moduli are used to describe the stress-strain relationship. The "Hysteresis Loop" method was used in this investigation to experimentally determine the material constants. This method was found to be convenient and direct for the experimental evaluation of the constants. These dynamic constants may then be used in a computer analysis, i.e., finite elements analysis, to determine the stress distribution in the membrane when subjected to loads or deformations.

Acetamides↗

Finite element stress analysis of tooth-to-implant fixed partial denture designs.

PURPOSE: The purpose of this study was to conduct a three-dimensional finite element stress analysis to compare models representing a natural tooth and an integrated implant connected with rigid and nonrigid prostheses. MATERIALS AND METHODS: The mathematical models described an integrated implant connected to a second premolar tooth with a three-unit metal-ceramic fixed partial denture. In one model, the tooth and implant were rigidly connected, and in the other, a nonrigid connection was assumed. From a simulated vertical load the computer generated resultant stress contours and values (compressive and tensile) in horizontal and vertical dimensions. RESULTS: A comparison of the magnitude and pattern of stresses generated in the models shows minimal differences. Although the maximum stress values were slightly higher in some areas of the rigid prosthesis model, the differences were negligible. CONCLUSIONS: Based on the similarities in both the patterns of stress contours and the stress values generated in the two models, advocating a nonrigid connection because of a biomechanical advantage may be erroneous.

Alveolar Process↗

Biomechanical research on junction system of bone with biomaterials.

Regarding the junction of bioceramics with original bone, which have quite different material constants of Young's modulus and Poisson's ratio from each other, synostosis (ankylosis) cannot be obtained under severe loading conditions. Therefore, it is necessary to introduce a new junction system for the interface between the biomaterial mechanical organ and original bone. The jointing system of dental root to jawbone reflects on the function against mastication. The interface between different mechanical organs with different materials necessitates a specific juncture system under severe loading because of the disparity of material constants. The authors already reported the result of studies on the shape effect of artificial roots in functioning jawbone by means of finite element analysis. Studies on the functional effect of artificial roots in undulated shape were carried out biomechanically by means of finite element analysis using models to investigate an effective juncture system between bone and biomaterials. The results of finite element analysis were compared with the findings obtained from histological specimens. To observe the juncture state of bioceramics with tubular bone cortex, tubular apatite artificial bone was implanted in the femur of a dog. From these studies, the following results and conclusions were obtained: (a) The fibrous juncture system around bioceramics has an important role, after which the principal stress trajectories are converted; and (b) optimal undulated morphology compatible to the artificial bone's juncture system by means of fibrous ligament is essential for remodeling of the bone around the artificial skeletal bone.

Animals↗

A biomechanical study of the cortex-anchorage vertebral screw.

OBJECTIVE: To obtain a comprehensive understanding on the effect of the improvement of fixation strength and on the optimal design in various geometrical parameters of a new screw system through biomechanical analyses. DESIGN: A new screw with the cortex-anchorage was designed and manufactured to improve the fixation of the instrumentation for osteoporotic spine. There were four expandable wings distributed around the screw after insertion. BACKGROUND: Screw loosening or loss of correction caused by insufficient mechanical stability on the bone-screw interface is frequently found in osteoporotic subjects. Similarly, the removal and replacement of a screw in a revision procedure substantially decreases its mechanical fixation. Since cortex is the most rigid part in the vertebral body, emphasis on the cortex-anchorage may offer an optimal fixation of screws. METHODS: The biomechanical evaluation that consists of the pullout test and the finite element analysis was applied to identify the stabilizing effect and the optimal design for the new screw system. In the pullout experiment, the porcine vertebral body with a hollow block of cancellous bone was proposed to simulate an osteoporotic spine. This osteoporotic model was specially simulated the degeneration and destruction of the cancellous bone in vertebrae. In the finite element analysis, the reduction of elastic modulus was used in various levels of vertebral degeneration. RESULTS: Pulling screws out of vertebral bodies with a hollow block of cancellous bone, the mean pullout force was 729 (SD 159) N for the conventional screws, and 1072 (SD 179) N for the new screw system. The finite element analysis showed that the longer screw with bi-cortex fixation was the better option in reducing the bony stress and increased the stability. As the height of wings changed, the stress distributed on vertebral body indicated the lowest in fixation by a screw with the largest wings. Nevertheless, there existed a least displacement of vertebral body and moderately low stress on wings' lateral end when assembled with the middle size wings. CONCLUSION: The stabilization function of expansive wings of the new screw system was enhanced in the osteoporotic vertebra and better than that of a conventional screw. The finite element analysis showed a middle size wing could help the screw to reduce the risk of failure and to improve the vertebral stability. RELEVANCE: Screw loosening or loss of correction caused by insufficient mechanical stability on the bone-screw interface is frequently found in osteoporotic subjects. From the biomechanical point of view, this study had shown that a new design of screw could improve the fixation of the instrumentation for osteoporotic spine. With further investigations that includes the clinical proof and the development of a cortex-anchorage vertebral screw may provide a valuable alternative to the spinal instrumentation for the patients with osteoporosis.

Animals↗

[Three dimensional finite element stress analysis in the vertical fractured first premolar after bonding and replantation].

PURPOSE: To evaluate the change of stress distribution after bonding and replantation of vertical fractured first maxillary premolar. METHODS: The stress distribution in two types of loading and different treatments on the vertical fractured first maxillary premolar were analyzed by three dimensional finite element. The gap was respectively filled with Clearfil SE Bond and Super Bond C & B; and vertical and lateral stress force was calculated. RESULTS: The result of the FEM study of adhesive fracture tooth indicated that the stress distribution was similar to the normal tooth, Clearfil SE Bond was better than Super Bond C & B. CONCLUSION: The treatment of bonding and replantation for vertical fractured tooth is effective.

Bicuspid↗

Soft tissue changes in patients with Class II Division 1 malocclusions treated using Twin Block appliances: finite-element scaling analysis.

To determine changes in soft tissue profile in patients with Class II division 1 malocclusions treated with Twin Block appliances (TBA), 99 pairs of lateral cephalographs were traced and 25 soft tissue landmarks digitized. Procrustes superimposition was used to generate average soft tissue profiles scaled to an equivalent size. Statistical differences between prepubertal, pre- and post-treatment profiles were found using ANOVA (P < 0.001). Similarly, significant differences were found between adolescent, pre- and post-treatment profiles (P < 0.001). Using a colour-coded finite element scaling analysis (FESA) programme to localize size change, male prepubertal post-treatment configurations revealed local increases in size at the labiomental groove (approximately 25%) with negative allometry (size-related form change approximately 5%) in the labial and symphyseal regions. For the female prepubertal post-treatment configuration, local increases in size were conspicuous also at the labiomental groove (approximately 6%). Male adolescent post-treatment configurations revealed increases in size in the nasal, mental, and labiomental groove regions (approximately 18%) with negative allometries associated with the upper and lower lips (approximately 20%). For the female adolescent post-treatment configuration, the labial fissure showed an increase in size (approximately 17%), whereas the upper and lower lips and symphyseal region exhibited negative allometries (approximately 5-15%). For shape change, all soft tissue post-treatment configurations were highly isotropic (uniform shape change) over the entire facial nodal mesh except in the areas of the labiomental region and the labial fissure. Thus, in children and adolescents treated for Class II malocclusions a less pronounced labiomental groove is associated with using TBAs, which may provide a more effective anterior lip seal.

Adolescent↗

Evaluation of two post core systems using two different methods (fracture strength test and a finite elemental stress analysis).

The aim of this study was to compare a fiber composite laminate (FCL) post core and a conventional cast post core system by using two different methods. The first method was a conventional fracture strength test, and the second was a finite elemental stress-analysis method (FEM). For the conventional fracture strength test, 20 extracted, human upper, central incisors were used. The teeth were decoronated, treated endodontically, and restored with two post core systems. After embedding the samples in resin blocks, a loading force was applied to the teeth at a crosshead speed of 5 mm/ min at an angle of 45 degrees to the long axis of the tooth. The data were recorded, and the results were compared by using the Mann-Whitney U test. There was no statistically significant difference between the two post systems (p > 0.05). For FEM analysis, a pseudo three-dimensional model of a maxillary central incisor, theoretically restored with either a cast post or an FCL, was used. The analysis was performed by using the structural analysis program (SAP90). FEM analysis showed that stress was accumulated within the cast post core system, and transmission of stress to supportive structures and the tooth was low. This is an advantage for tooth and supporting tissues. When the FCL post core system was evaluated by FEM, the results indicated that this system transferred stress to supportive structures and the tooth while stress accumulation within the post system was low. This is an advantage for the restoration but disadvantage for the supporting tissues.

Computer Simulation↗

Technical note: A novel boundary condition using contact elements for finite element based deformable image registration.

Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are usually based on the surface matching of the organ in two images. Such a surface matching, however, is hard to obtain from medical images. In this study, we developed a new boundary condition to circumvent the traditional difficulties. Finite element contact-impact analysis was employed to simulate the interaction between the organ of interest and the surrounding body. The displacement loading is not necessarily specified. The algorithm automatically deforms the organ model into the minimum internal energy state. The analysis was performed on CT images of the lung at two different breathing phases (exhalation and full inhalation). The result gave the displacement vector map inside the lung. Validation of the result showed satisfactory agreement in most parts of the lung. This approach is simple, operator independent and may provide improved accuracy of the prediction of organ deformation.

Algorithms↗

The nonsteady state modeling of freeze drying: in-process product temperature and moisture content mapping and pharmaceutical product quality applications.

INTRODUCTION: Theoretical models of the freeze-drying process are potentially useful to guide the design of a freeze-drying process as well as to obtain information not readily accessible by direct experimentation, such as moisture distribution and glass transition temperature, Tg, within a vial during processing. Previous models were either restricted to the steady state and/or to one-dimensional problems. While such models are useful, the restrictions seriously limit applications of the theory. An earlier work from these laboratories presented a nonsteady state, two-dimensional model (which becomes a three-dimensional model with an axis of symmetry) of sublimation and desorption that is quite versatile and allows the user to investigate a wide variety of heat and mass transfer problems in both primary and secondary drying. The earlier treatment focused on the mathematical details of the finite element formulation of the problem and on validation of the calculations. The objective of the current study is to provide the physical rational for the choice of boundary conditions, to validate the model by comparison of calculated results with experimental data, and to discuss several representative pharmaceutical applications. To validate the model and evaluate its utility in studying distribution of moisture and glass transition temperature in a representative product, calculations for a sucrose-based formulation were performed, and selected results were compared with experimental data. THEORETICAL MODEL: The model is based on a set of coupled differential equations resulting from constraints imposed by conservation of energy and mass, where numerical results are obtained using finite element analysis. Use of the model proceeds via a "modular software package" supported by Technalysis Inc. (Passage/ Freeze Drying). This package allows the user to define the problem by inputing shelf temperature, chamber pressure, container properties, product properties, and numerical analysis parameters required for the finite element analysis. Most input data are either available in the literature or may be easily estimated. Product resistance to water vapor flow, mass transfer coefficients describing secondary drying, and container heat transfer coefficients must normally be measured. Each element (i.e., each small subsystem of the product) may be assigned different values of product resistance to accurately describe the nonlinear resistance behavior often shown by real products. During primary drying, the chamber pressure and shelf temperature may be varied in steps. During secondary drying, the change in gas composition from pure water to mostly inert gas is calculated by the model from the instantaneous water vapor flux and the input pumping capacity of the freeze dryer. RESULTS: Comparison of the theoretical results with the experiment data for a 3% sucrose formulation is generally satisfactory. Primary drying times agree within two hours, and the product temperature vs. time curves in primary drying agree within about +/-1 degrees C. The residual moisture vs. time curve is predicted by the theory within the likely experimental error, and the lack of large variation in moisture within the vial (i.e., top vs. side vs. bottom) is also correctly predicted by theory. The theoretical calculations also provide the time variation of "Tg-T" during both primary and secondary drying, where T is product temperature and Tg is the glass transition temperature of the product phase. The calculations demonstrate that with a secondary drying protocol using a rapid ramp of shelf temperature, the product temperature does rise above Tg during early secondary drying, perhaps being a factor in the phenomenon known as "cake shrinkage." CONCLUSION: The theoretical results of in-process product temperature, primary drying time, and moisture content mapping and history are consistent with the experimental results, suggesting the theoretical model should be useful in process development and "trouble-shooting" applications.

Chemistry, Pharmaceutical↗

Dynamic analysis of the aortic valve using a finite element model.

BACKGROUND: The major aim of this study was to examine the leaflet/aortic root interaction during the cardiac cycle, including the stresses developed during the interaction. METHODS: Dynamic finite element analysis was used along with a geometrically accurate model of the aortic valve and the sinuses. Shell elements along with proper contact conditions were also used in the model. Pressure patterns during the cardiac cycle were given as an input, and a linear elastic model was assumed for the material. RESULTS: We found that aortic root dilation starts before the opening of the leaflet and is substantial by the time leaflet opens. Dilation of the root alone helps in opening the leaflet to about 20%. The equivalent stress pattern shows an instantaneous increase in stress at the coaptation surface during closure. Stresses increase as the point of attachment is approached from the free surface. CONCLUSIONS: The complex interplay of the geometry of the valve system can be effectively analyzed using a sophisticated dynamic finite element model. Results not previously brought out by the earlier static analysis shed new light on the root/valve interaction.

Aorta↗

Craniofacial growth in apert syndrome as measured by finite-element scaling analysis.

A new tool for the study of biological form change is applied in a comparison of craniofacial growth in normal children and those affected with Apert syndrome. Using finite-element scaling analysis, the magnitude of size change during postnatal growth in the Apert sample was determined to be generally less than normal, and the magnitude of shape change was generally greater than normal. No consistent, statistically significant, alteration from normal growth was defined in the Apert sample, however. There appears to be no consistent effect on general cell and tissue proliferation in Apert syndrome. Rather, specific subpopulations of cells and tissues may be affected differentially over time.

Acrocephalosyndactylia↗

Applications of finite-element scaling analysis in primatology.

The study of biological shape in three dimensions using landmark data can now be accomplished using several alternative methods. This report focuses on the use of finite-element scaling analysis in primate craniofacial morphology. The method is particularly useful in its ability to localize the differences between forms, thereby indicating those loci that differ most between specimens. Several examples of this feature are provided from primatological research. Particulars of the methods are also discussed in an attempt to provide the reader with cautionary knowledge for prudent application of the method in future research.

Animals↗

[Tooth movement by biomechanical technique in orthodontic treatment].

The purpose of this study was to analyze tooth movement by measuring the electric impedance of the wire and by using the nonlinear finite element analysis. In this study, the HP4338A Milliohmmeter was used and the model consisted of a metal tooth, silicone bath, bracket, and orthodontic wire. Then, the two-dimensional finite elements were used and the model consisted of tooth, periodontal ligament, alveolar bone, bracket, and orthodontic wire. There were two analyses. The first was the contact nonlinear finite element analysis of elastic deformation in the displaced tooth at the slide points between the bracket and wire where two gap element areas existed, and the second was the material nonlinear finite element analysis of the stress relaxation in bone at the fixing points between the bracket and wire where two rigid element areas, differing from the gap element areas, existed. The results were as follows: 1. The linear proportion between the electric impedance and the orthodontic wire was found. Therefore very minute tooth movements became measurable with changes of the wire electric impedance. 2. During tooth movement, the stick between the bracket and the wire altered with the slip ones repeatedly. 3. The movement of the displaced tooth at the center of rotation was counterclockwise. 4. The movement of the displaced tooth at the bracket position was clockwise.

Biomechanical Phenomena↗

Finite-element stress analysis of a multicomponent model of sheared and focally-adhered endothelial cells.

Hemodynamic forces applied at the apical surface of vascular endothelial cells may be redistributed to and amplified at remote intracellular organelles and protein complexes where they are transduced to biochemical signals. In this study we sought to quantify the effects of cellular material inhomogeneities and discrete attachment points on intracellular stresses resulting from physiological fluid flow. Steady-state shear- and magnetic bead-induced stress, strain, and displacement distributions were determined from finite-element stress analysis of a cell-specific, multicomponent elastic continuum model developed from multimodal fluorescence images of confluent endothelial cell (EC) monolayers and their nuclei. Focal adhesion locations and areas were determined from quantitative total internal reflection fluorescence microscopy and verified using green fluorescence protein-focal adhesion kinase (GFP-FAK). The model predicts that shear stress induces small heterogeneous deformations of the endothelial cell cytoplasm on the order of <100 nm. However, strain and stress were amplified 10-100-fold over apical values in and around the high-modulus nucleus and near focal adhesions (FAs) and stress distributions depended on flow direction. The presence of a 0.4 microm glycocalyx was predicted to increase intracellular stresses by approximately 2-fold. The model of magnetic bead twisting rheometry also predicted heterogeneous stress, strain, and displacement fields resulting from material heterogeneities and FAs. Thus, large differences in moduli between the nucleus and cytoplasm and the juxtaposition of constrained regions (e.g. FAs) and unattached regions provide two mechanisms of stress amplification in sheared endothelial cells. Such phenomena may play a role in subcellular localization of early mechanotransduction events.

Animals↗

[Two-dimensional finite element stress analysis of simulating restored teeth with wedge-shaped defects under loads].

OBJECTIVE: To study the concentration of stresses at the cervix with simulating restoration of tooth defects. METHODS: A two-dimensional finite element model of a mandible first premolar with defect from longitudinal section was developed. The model was simulatedly restored, respectively by composite resin and glass ionomer cement, and then investigated stress variation in the cervical area. RESULTS: In the restored models, both of materials improved the concentration of stresses at the cervical area. The composite resin and the glass ionomer cement restorations made the maximum principal stresses declined respectively to 36.2 MPa and 42.5 MPa, which were close to the value of normal tooth in the deepest area of defects. CONCLUSION: The concentration of stresses are improved in the cervical area with teeth defects restored.

Composite Resins↗

Design of monolimb using finite element modelling and statistics-based Taguchi method.

BACKGROUND: Monolimb is a transtibial prosthesis having the socket and shank molded into one piece of thermoplastic material. If properly designed, the shank of a monolimb can have a controlled deflection during walking which simulates the ankle joint motions to some extent. However, there is no clear guidance for the design of monolimb considering the dilemma between shank flexibility and structural integrity. METHODS: Finite element analysis was used to simulate structural tests based on ISO10328 on monolimbs of different configurations. Statistics-based Taguchi method was employed to identify the significance of each design factor in controlling the deformation and stress within monolimbs. The design factors considered were the thickness of the thermoplastics, anteroposterior and medialateral dimensions of the elliptical shank, and depth of the posterior seam line. By progressively fine-tuning the design factors, the monolimb configuration was optimized giving offering appropriate flexibilities of the shank and would not structurally fail in normal uses. Experimental structural test was used to validate the finite element model. FINDINGS: Anteroposterior dimension of the shank was shown to be the most important design factor determining the peak von Mises stress values, deformation and dorsiflexion angles of monolimbs. Depth of seam line appears much less important than the other three factors. A monolimb fulfilling the design requirements was suggested. Experimental test results reasonably matched with the finite element results. INTERPRETATION: Finite element analysis and Taguchi method was shown to be an effective method in optimizing the structural design of prostheses. Further prosthetic design can be facilitated based on the degree of importance of the design factors on the structural behavior of the prosthesis. Gait analysis of amputees using the suggested monolimb design is needed in the future.

Algorithms↗