Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Elbow Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Mechanism of accumulation of 99mTc-sulesomab in inflammation.

UNLABELLED: 99mTc-Sulesomab, the Fab fragment of anti-NCA-90, is used as an in vivo granulocyte labeling agent for imaging inflammation. It is not clear to what extent it targets cells that have already migrated into the interstitial space of an inflammatory lesion as opposed to circulating cells. The contribution to signal of radioprotein diffusion in the setting of increased vascular permeability is also poorly documented. METHODS: We compared the local kinetics of (99m)Tc-sulesomab and (99m)Tc-labeled human serum albumin (HSA), which have similar molecular sizes, in 7 patients with orthopedic infection proven by clearly positive (111)In-leukocyte scintigraphy. (99m)Tc-Sulesomab and (99m)Tc-HSA were administered in sequence separated by an interval of 2-6 d. Images were obtained 1, 3, 4, and 6 h after injection, and multiple venous blood samples were obtained for blood clearance measurement. Patlak-Rutland (P-R) analysis was performed to measure lesion and control tissue protein clearance. Target-to-background tissue (T/Bkg) ratios were calculated for each radioprotein and compared with the T/Bkg ratio for (111)In-leukocytes. (99m)Tc-Sulesomab binding to granulocytes was measured in vitro and ex vivo and to primed and activated granulocytes in vitro. RESULTS: After intravenous injection, <5% of the circulating radioactivity was cell bound with both radioproteins so that the P-R curves could therefore be assumed to represent extravascular uptake of free protein. The blood clearance (mean +/- SD) of sulesomab was 23.4 +/- 11.7 mL/min, approximately 5 times greater than that of HSA, for which it was 4.8 +/- 3.1 mL/min. Likewise, clearance into the lesion of sulesomab was consistently higher than that of HSA, on average about 3 times as high. Nevertheless, the T/Bkg ratios for sulesomab and HSA were similar, except at 6 h when that of HSA (2.14 +/- 0.6) was higher than that of sulesomab (1.93 +/- 0.5; P approximately 0.01). Both values were considerably less than the T/Bkg ratio on the (111)In-leukocyte images, which, at 22 h, was 12.3 +/- 5.3. Moderate clearance of sulesomab, but not HSA, was seen in the control tissue. Granulocytes bound significantly more (99m)Tc-sulesomab in vitro when primed or activated. CONCLUSION: (a) Sulesomab does not localize in inflammation as a result of binding to circulating granulocytes; (b) sulesomab is cleared into inflammation nonspecifically via increased vascular permeability; nevertheless, it may be cleared after local binding to primed granulocytes or bind to activated, migrated extravascular granulocytes; and (c) HSA produces a similar or higher T/Bkg ratio than sulesomab because sulesomab is cleared into normal tissues and because image positivity in inflammation is significantly dependent on local blood-pool expansion.

Adult↗

The Reverse Shoulder Prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients.

BACKGROUND: Patients who have pain and dysfunction from glenohumeral arthritis associated with severe rotator cuff deficiency have few treatment options. The goal of this study was to retrospectively evaluate the short-term results of arthroplasty with use of the Reverse Shoulder Prosthesis in the management of this problem. METHODS: We report the results for sixty patients (sixty shoulders) with a rotator cuff deficiency and glenohumeral arthritis who were followed for a minimum of two years. Thirty-five patients had no previous shoulder surgery, whereas twenty-three had had either an open or arthroscopic rotator cuff repair, one had had a subacromial decompression, and one had had a biceps tendon repair. All patients were assessed preoperatively and postoperatively with the American Shoulder and Elbow Surgeons scoring system for pain and function and with visual analog scales for pain and function. They were also asked to rate their satisfaction with the outcome. The shoulder range of motion was measured preoperatively and postoperatively. RESULTS: The average age of the patients was seventy-one years. The average duration of follow-up was thirty-three months. All measures improved significantly (p < 0.0001). The mean total score on the American Shoulder and Elbow Surgeons system improved from 34.3 to 68.2; the mean function score, from 16.1 to 29.4; and the mean pain score, from 18.2 to 38.7. The score for function on the visual analog scale improved from 2.7 to 6.0, and the score for pain on the visual analog scale improved from 6.3 to 2.2. Forward flexion increased from 55.0 degrees to 105.1 degrees, and abduction increased from 41.4 degrees to 101.8 degrees. Forty-one of the sixty patients rated the outcome as good or excellent; sixteen were satisfied, and three were dissatisfied. There were a total of thirteen complications in ten patients (17%). Seven patients (12%) had eight failures, requiring revision surgery to another Reverse Shoulder Prosthesis in five patients (one shoulder had two revisions) and revision to a hemiarthroplasty in two patients because of deep infection. CONCLUSIONS: The data from this study suggest that arthroplasty with the Reverse Shoulder Prosthesis may be a viable treatment for patients with glenohumeral arthritis and a massive rotator cuff tear. However, future studies will be necessary to determine the longevity of the implant and whether it will provide continued improvement in function.

Adult↗

The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. a minimum two-year follow-up study of sixty patients surgical technique.

BACKGROUND: Patients who have pain and dysfunction from glenohumeral arthritis associated with severe rotator cuff deficiency have few treatment options. The goal of this study was to retrospectively evaluate the short-term results of arthroplasty with use of the Reverse Shoulder Prosthesis in the management of this problem. METHODS: We report the results for sixty patients (sixty shoulders) with a rotator cuff deficiency and glenohumeral arthritis who were followed for a minimum of two years. Thirty-five patients had no previous shoulder surgery, whereas twenty-three had had either an open or arthroscopic rotator cuff repair, one had had a subacromial decompression, and one had had a biceps tendon repair. All patients were assessed preoperatively and postoperatively with the American Shoulder and Elbow Surgeons scoring system for pain and function and with visual analog scales for pain and function. They were also asked to rate their satisfaction with the outcome. The shoulder range of motion was measured preoperatively and postoperatively. RESULTS: The average age of the patients was seventy-one years. The average duration of follow-up was thirty-three months. All measures improved significantly (p < 0.0001). The mean total score on the American Shoulder and Elbow Surgeons system improved from 34.3 to 68.2; the mean function score, from 16.1 to 29.4; and the mean pain score, from 18.2 to 38.7. The score for function on the visual analog scale improved from 2.7 to 6.0, and the score for pain on the visual analog scale improved from 6.3 to 2.2. Forward flexion increased from 55.0 degrees to 105.1 degrees , and abduction increased from 41.4 degrees to 101.8 degrees . Forty-one of the sixty patients rated the outcome as good or excellent; sixteen were satisfied, and three were dissatisfied. There were a total of thirteen complications in ten patients (17%). Seven patients (12%) had eight failures, requiring revision surgery to another Reverse Shoulder Prosthesis in five patients (one shoulder had two revisions) and revision to a hemiarthroplasty in two patients because of deep infection. CONCLUSIONS: The data from this study suggest that arthroplasty with the Reverse Shoulder Prosthesis may be a viable treatment for patients with glenohumeral arthritis and a massive rotator cuff tear. However, future studies will be necessary to determine the longevity of the implant and whether it will provide continued improvement in function.

Adult↗

Surgical treatment of osteoarthritis.

Surgical treatment of OA is appropriate when conservative therapy fails or is inadequate. The veterinary orthopedist's goals in treatment should be to alleviate pain, maintain function, and prevent or remove the potential for further degeneration of the joint. Currently, in veterinary surgery, THR and femoral head and neck excision are the primary treatments for OA of the coxofemoral joint. Other joints are treated primarily by arthrodesis or excision arthroplasty. Arthroscopy is proving to be a valuable tool in the diagnosis and treatment of OA, and total stifle and elbow replacement and cartilage resurfacing through chondrocyte grafting are on the horizon as potential treatment options.

Animals↗

SMART stent for salvage of hemodialysis access grafts.

PURPOSE: To evaluate the SMART stent for treating angioplasty-resistant hemodialysis access venous stenoses. MATERIALS AND METHODS: A retrospective study of 64 patients with polytetrafluoroethylene grafts who were treated with the SMART stent at 69 locations in the venous outflow tract was undertaken. Stents were used for elastic recoil after percutaneous transluminal angioplasty, venous rupture, or recurrent stenosis less than 3 months after angioplasty. When angiographic follow-up was available, the degree of in-stent restenosis was measured. Primary patency was determined, and, when applicable, compared with that of previous angioplasty treatments of the same lesion. RESULTS: The SMART stent was placed in 15 central veins and 54 peripheral veins, with a 98% technical success rate and a 97% clinical success rate. The mean primary access patency times were 14.9 months and 8.9 months in patients who received central and peripheral stents, respectively. In 19 patients whose central or peripheral venous stenoses were previously treated with angioplasty, the mean primary access patency was increased from 2.5 months to 10.6 months after placement of the SMART stent (P = .0003). Angiography in 29 patients after an average of 348 days showed 55% mean in-stent stenosis. The only stent-related complication occurred in a patient who had venous dissection associated with the edge of a SMART stent placed at the elbow. CONCLUSION: The SMART stent is safe and effective for treating dialysis access venous stenoses that are resistant to standard angioplasty.

Angiography, Digital Subtraction↗

Sports after total joint replacement.

Today's patients require additional guidance in their expectations after replacement surgery. Failure rates for shoulder, hip, and knee replacements across most studies are approximately 0.5% to 1% per year, including infection, loosening, and wear of the parts. Elbow and ankle replacements will likely require more restrictions and have slightly higher revision rates.

Arthroplasty, Replacement↗

Upper extremity total joint replacement.

Current techniques of total joint replacement surgically correct badly destroyed joints by the insertion of plastic and metal components, which are secured to the skeleton by methylmethacrylate cement. This approach began in England in 1962 and in the United States in 1967. Recent development in the field of upper extremity joint replacement allow implementation of refined total shoulder, elbow, and wrist prostheses. Although less experience has been gained with these prostheses than with total hip and knee replacements, preliminary results are encouraging.

Arm↗

[Repair of refractory bone nonunion in the distal humerus].

OBJECTIVE: To investigate the effect of microsurgical repair of refractory bone defects and nonunion in distal humerus. METHODS: Twelve cases of bone defects and nonunion in distal humerus were repaired with free vascularised fibular graft and fixed with the anatomical bone plate. Of the 12 cases, 8 had pseudarthrosis, and 4 had bone defects 3-5 cm. Fibular graft ranged from 5-15 cm, 8.5 cm in average. RESULTS: After a follow-up of 3-18 months, 8.5 months in average, all cases of free vascularised fibular graft healed within 3-8 months. The fibular graft thickened as time passed. Normal recessive osseous elbow joint, improvement in the inflection and extension of elbow joint, and normal revolving of forearm were attained. The short of limbs were corrected. Satisfactory functions of supporting and fine operation were attained. CONCLUSION: With the support of anatomical bone plate, the fibular graft can help the recovery of joint function and repair bone defects and nonunion as to avoid joint replacement with prosthesis.

Adolescent↗

Management of infected shoulder replacement.

BACKGROUND: The purpose of the present work is to present treatment options and our own results for patients with infected shoulder alloarthroplasties. METHODS: Twelve patients with an infected shoulder replacement were treated. Their age ranged from 56 to 82 years. Indications for surgical revision were clinical symptoms compatible with an infection or positive serologic tests, especially an elevated C-reactive protein. Aspirated intra-articular fluid with a white blood cell count above 30,000 or positive for bacterial growth was also an important diagnostic feature. Retrospective analysis differentiated three groups with three different treatment regimens. Group 1 with early infection but without soft-tissue involvement (n=1): this particular patient underwent arthroscopic synovectomy. Group 2 with early infection and soft-tissue involvement within 4 weeks after index surgery (n=1): this patient underwent open synovectomy. The largest group was group 3 with late infection (n=10): these patients were treated with two-stage revision and a temporary spacer. RESULTS: The time between explantation and reimplantation ranged between 4 weeks and 6 months. With the temporary spacer, an anatomically stable condition could be established for all patients, and reconstruction of the humeral length even in long implants was possible. All patients underwent physiotherapy with the temporary spacer in place. A positive intraoperative microbiologic specimen was only found in 4 patients. In both group 1 and 2 patients, the infection healed, and thus the original implant could be kept in situ. In 8 patients, the temporary spacer was removed and exchanged for a regular implant. The postoperative raw Constant score at the time of the last follow-up examination was 48, due mainly to a loss of motion and power. All shoulders were stable, and the elbow function was good. CONCLUSION: Use of an antibiotic-loaded spacer allows successful treatment of infected shoulder replacements.

Aged↗

Maintenance of stump length of both upper extremities after severe electrical burn injury.

A patient with electrical injury to both upper extremities which necessitated amputation above the elbow on both sides is presented. Further débridement on the stumps resulted in extensive exposure of bone with little coverage by skin and granulation tissue. Adequate coverage and maintenance of the length of both stumps was possible with bilateral myocutaneous latissimus dorsi flaps. This enabled the patient to carry out various activities and to wear a prosthesis.

Adult↗

Replacement of the proximal humerus with a ceramic prosthesis: a preliminary report.

Insertion of a multicomponent ceramic prosthesis with extracortical fixation to the conically reamed shaft of the humerus was performed in 7 patients after resection of 4 malignant and 3 benign tumors of the proximal humerus. The length of the replacement ranged from 9 to 18 cm. Fixation was secure in all but one patient, who sustained a fracture through the proximal humerus. Subluxation occurred in 3 patients but posed no difficulty, except in one patient who required revision for a dislocation. Functionally, little active motion is achieved, but the implant provides a spacer to permit efficient use of the hand and elbow. No patient has had local recurrence of the tumor. One patient died one year postoperatively from an unrelated second primary cancer. Although the preliminary results are encouraging, further investigations are necessary on the mechanical aspects of the cone fixation principle and of the techniques of shoulder muscle reconstruction to improve the function of the prosthetic joint.

Adult↗

Reduction and pinning of pediatric supracondylar humerus fractures in the prone position.

Supracondylar humerus fractures are common pediatric injuries; the preferred treatment for displaced fractures is closed reduction and percutaneous pin fixation. We present a technique for closed reduction and pinning using prone-patient positioning. Prone positioning facilitates fracture reduction and safe pin placement while avoiding elbow hyperflexion. We prefer this technique to the commonly described method of fracture reduction and pinning with the patient supine.

Bone Nails↗

What's new in shoulder surgery.

The purpose of this update on shoulder surgery is to discuss, in summary fashion, topics presented at selected orthopaedic meetings during the time-period of August 1999 to July 2000. Sources for this article were presentations and symposia at meetings of the American Orthopaedic Society for Sports Medicine (Specialty Day, Orlando, Florida, March 2000, and the Twenty-sixth Annual Meeting, Sun Valley, Idaho, June 2000), the Arthroscopy Association of North America (Specialty Day, Orlando, Florida, March 2000, and the Nineteenth Annual Meeting, Miami, Florida, April 2000), the American Academy of Orthopaedic Surgeons (Sixty-seventh Annual Meeting, Orlando, Florida, March 2000), the American Shoulder and Elbow Surgeons (Specialty Day, Orlando, Florida, March 2000, and the Sixteenth Annual Meeting, Philadelphia, Pennsylvania, October 1999), and the American Orthopaedic Association (113th Annual Meeting, Hot Springs, Virginia, June 2000).

Arthroscopy↗

Proximal humeral replacement for tumor. A preliminary report.

Five patients who underwent prosthetic proximal humeral replacement for tumor were evaluated postoperatively at an average of 52 months. Four patients were reasonably satisfied with their results: they were relieved of pain which existed preoperatively and had hand and elbow function. Shoulder rotation was recovered satisfactorily. However, elevation and abduction were significantly compromised. No radiographic evidence of prosthetic loosening was identified.

Adolescent↗

Treatment of displaced radial head fractures by internal fixation with absorbable pins.

OBJECTIVE: To study the effect of internal fixation with absorbable pins on treatment of displaced radial head fractures. METHODS: From May 1999 to May 2004, 16 patients with displaced radial head fractures (Mason types II and III) were treated with internal fixation by absorbable pins. The duration of follow-up averaged 22.6 months (12-58 months). The outcome was assessed on the basis of elbow motion, radiographic findings and the functional rating score delineated by Broberg and Morrey. RESULTS: All fractures healed within 10 months without avascular necrosis of radial head. The mean elbow flexion loss was 15 degrees (0 degrees-35 degrees), and pronation and supination decreased by 10 degrees (0 degrees-30 degrees) on average compared with those of the contralateral elbow. Five patients had an excellent result, 6 a good result, and 3 a fair result according to the criteria of Borberg and Morrey. CONCLUSIONS: Internal fixation with absorbable pins is an effective method in treating displaced radial head fractures. It can maintain the biomechanical stability of forearm, improve the elbow function and avoid second operation.

Adult↗